Housing Urban and Rular Development Government Departments Closing in 5 days TDR #56435347

Tender For General-Comprehensive Electrical Maintenance Work At Revenue Tower Adoor -Comprehensive Electrical Maintenance Work At Revenue Tower Adoor-General Electrical Work

Issued by Government Departments · Pathanamthitta, Kerala
Tender Value
21.15 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
5 days left
EMD
50000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathanamthitta → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for General-Comprehensive Electrical Maintenance Work At Revenue Tower Adoor -Comprehensive Electrical Maintenance Work At Revenue Tower Adoor-General Electrical Work

BOQ

Name of Work:- GENERAL-COMPREHENSIVE ELECTRICAL MAINTENANCE WORK AT REVENUE TOWER ADOOR -COMPREHENSIVE ELECTRICAL MAINTENANCE WORK AT REVENUE TOWER ADOOR-General Electrical Work
Sl. No. Item Description
1WIRING
21.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
31.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B
41.15.1:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group A
51.15.2:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group B
61.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
71.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
81.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
91.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
101.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
111.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
121.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
131.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
141.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
151.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
161.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
171.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
181.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
191.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
20SWITCH
212.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
222.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
232.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
242.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
252.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
262.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
272.13.3:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
282.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
292.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps
302.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
312.5.2:Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 Way(4+24), Double door
32OD423248/2025-2026:Supplying and fixing following rating ,four pole 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
33OD423245/2025-2026:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
34OD423247/2025-2026: Supplying and fixing following rating, kit kat porcelain fuse unit 415 volt 500 Amp suitable for 500 KVA out door Transformer
352.1.4:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N
362.1.5:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.160 Amp TP&N
372.1.6:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.200 Amp TP&N
38CABLE
399.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
409.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
419.2.28:Supplying and making outdoor end termination with cast resin compound including aluminiumlugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 400 sq. mm
4290.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
4390.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
4490.12.7.43:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp
4590.12.7.44:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 50 sq mm
4690.12.7.45:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 70 sq mm
47FITTING
4890.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
49OD423240/2025-2026:Supply, conveyance, installation, testing and commissioning the following sizes of Exhaust fan in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS -225 mm ( 9?) minimum, Rated speed 1300rpm with air delivery 3 nos of MS powder-coated blade and frame
50OD423242/2025-2026:Supply, conveyance, installation, testing and commissioning the following sizes of Exhaust fan in the existing opening, fixing necessary bolt and nuts, making good the damages, etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper Conductor flex wire conforming to relevant ISS - heavy duty 450 mm ( 18 ?) minimum Rated speed 1300rpm withwith aire delivery- 5500m3/hr 4 nos of MS powder coated blade bolted to aluminium die cast spider balanced rated rpm frame is made from deep drawn steel the four arm fitted with rubber mounting for silent operation
51OD423241/2025-2026: Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
52OD423243/2025-2026:Supply conveyance, installation, testing and commissioning the light fittings of following types made with White powder-coated/pre-coated finish, CRCA channel for single for 1200 mm 18W/20W LED tube having IP20, 6000 K, 20W - 2000 lumens, Aluminum housing with PC diffuser, THD<20%, Surge - 2kV, CRI-80, 50000 burning hours, single-sided connection,. Multistage Isolated Constant Current Operated driver with range 110-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. all accessories and lamps directly on the wall and giving connections with 16/0.20 mm 3-core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required, 1200 mm 1X(18/20W) Aluminium housing with PC diffuser LED Tube ( LTT ) with box type fixture
53MODULAR ACCESSORY
541.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
551.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
561.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
571.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
581.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
591.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
601.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
611.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
621.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
631.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
641.49:Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
651.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
66PAINTING
6713.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
68OD423244/2025-2026:Removing existing paint from the metal surface by scraping/wire brushing and cleaning thoroughly to remove rust, dust, and loose particles; applying one coat of approved metal primer to the cleaned surface, including carrying out necessary minor patch repairs wherever required, and completing the work with proper surface preparation as per specifications
69PANEL
70OD1496/2026-2027:Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated Main Switch Board (MSB) panel fabricated out of 16 SWG CRCA sheet steel with 9 tank anti-corrosive treatment and powder coated finish, suitable for 415V, 3 Phase, 4 wire, 50Hz AC supply, fully compartmentalised, complete with hinged and earthed front doors, lockable handles, engraved name plates, danger notice boards, neoprene rubber gaskets, removable gland plates of 3mm thick sheet steel, lifting hooks, base channels, cable alley, internal partitions and all necessary accessories as required. The panel shall be free-standing type with adequate mechanical strength to withstand short-circuit forces, fully shrouded and compartmentalised, with sealable doors and ventilation louvers with wire mesh. The panel shall be provided with high conductivity aluminium busbars of suitable rating supported on SMC insulators with heat shrinkable sleeves, colour coded for phases, with separate neutral and earth busbars throughout the panel. Incoming shall consist of 800A, 50kA, 4 Pole Motorised Drawout Air Circuit Breaker (ACB) with microprocessor based protection for overload, short circuit and earth fault, complete with shunt trip, auxiliary contacts, ON/OFF and trip indication, motorised spring charging mechanism, drawout arrangement, safety shutters, mechanical interlocking and all accessories, along with 800/5A current transformers for metering and protection. Digital multifunction meter (Class-1 accuracy) shall be provided for measurement of voltage, current, frequency, power factor, kW, kVA, kWh, kVAh etc., complete with necessary CTs and accessories. RYB phase indicating LED lamps with control MCB and earth fault relay with CBCT and interlocking with incoming breaker shall also be provided. Outgoing feeders shall consist of 200A TPN Switch Disconnector Fuse units with HRC fuses – 3 Nos, 160A TPN Switch Disconnector Fuse unit with HRC fuses – 1 No, and 100A TPN Switch Disconnector Fuse units with HRC fuses – 4 Nos including 2 Nos spare feeders, complete with ON/OFF indication, door interlocking and cable termination. 800A Aluminium TPN busbar system with SMC supports, heat shrinkable sleeves and colour coding shall be provided complete. Panel shall have top cable entry with cable alley suitable for 3 runs of 3.5C x 400 sq.mm incoming cables. Panel shall be provided with earth busbar throughout, two earthing studs and door earthing using flexible copper links. Internal wiring shall be carried out using FRLS copper control wires, ferruled and terminated through PVC ducts. Panel shall be complete with engraved name plates, danger boards, phase indication, gland plates, cable alley, locking and interlocking arrangement, earthing studs, terminal blocks and provision for KSEB metering with visible glass and locking facility. Panel shall be factory tested for insulation resistance, high voltage, functional and relay testing and test certificates shall be submitted, complete as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56435347
AUTHORITY Government Departments
TENDER VALUE 21.15 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Kerala State Housing Board
Work Description Tender for General-Comprehensive Electrical Maintenance Work At Revenue Tower Adoor -Comprehensive Electrical Maintenance Work At Revenue Tower Adoor-General Electrical Work
Basic Detail
Tender No KSHB/PTA/T7/2026-27
Bidding Type Tender
Location
City Pathanamthitta
State Kerala
Key Dates
Publish Date 13 Jul 2026
Submission Date 20 Jul 2026
Open Date 22 Jul 2026
Finance
Tender Value 21.15 Lakhs
Tender Fee 2950
EMD 50000
Exemption Available
Document List
ad326221-5211-4c09-a389-e85cf55ea045.html
affidavit.pdf
BOQ_1454562.xls
EPayment.pdf
ipact.pdf
makelistele.pdf
PreliminaryAgreement.pdf
SBDELERTA.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

ad326221-5211-4c09-a389-e85cf55ea045.html

pdf

affidavit.pdf

xls

BOQ_1454562.xls

pdf

EPayment.pdf

pdf

ipact.pdf

pdf

makelistele.pdf

pdf

PreliminaryAgreement.pdf

pdf

SBDELERTA.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders