Tender For Provision Of Digital Axle Counter In Parallel To Dc Track Circuit In The Yard Of Ggc For Providing Dual Detection On Kota Division As Per Attached Boq.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Jul 2026
4 days left
EMD
2.12 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Digital Axle Counter In Parallel To Dc Track Circuit In The Yard Of Ggc For Providing Dual Detection On Kota Division As Per Attached Boq.
BOQ
| Sl. No. | Item Description |
| 1 | Supply of powder coated Relay Rack Assembly of Complete With Scaffolding, Fixtures and accessories including MS Bars for fixing of relay plug board, string rods fuse strips with bracket,11 Way Bus Bars with cover and mounting brackets, runway for cable/wires frame base assembly with IDF pillar etc. Siemens type & as per extant practice on W.C.Rly. Typical part list as per Annexure attached and Rack arrangement as per Sketch No SK -727 and Rack plan as approved by Engineer incharge. |
| 2 | Supply of powder coated Main Cable Termination rack of 1 Way complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal / WAGO - make terminal blocks, ladders, string rods, frame, base assembly, insulators, J bolt, nut/bolts & fasteners (Bakelite strips) etc. Siemens type or equivalent & as per extant practice on W.C. Rly. Typical part list as per Annexure-I and rack arrangement shall be as per sketch SK-727. Rack should be made of first class steel powder coated painting and rack manufacturer's certificate should be submitted. All runway for cables / wires shall be provied with PVC sleeve of proper size. |
| 3 | Supply of Fault analysis equipment along with necessary software required in connection with MSDAC system as per specification : HP Laptop or similar . 12th gen Core i7, 12 GB RAM, 1 TB HDD Window 11 Professional 64. or Latest |
| 4 | Supply and Installation of OFC joint enclosure and splicing of Optic fiber cable (48 fibres) and testing |
| 5 | Supply of Thermo shrink Jointing Kit for jointing underground 0.9 mm dia. cond. 4/6 quad cables as per specn No. IRS: TC-77/2012 (Rev.3.0) with Amend. 1, 2 & 3 or latest. |
| 6 | (i) Supply of 4 conductor disconnect terminal block with test & measurement facility, with screw less, spring cage clamp connections suitable for 0.08 to 2.5 Sq.mm conductor with current capacity of 16 Amps as per RDSO Spcn. No. RDSO/SPN/189/2004 Ver. 3.0 or latest. |
| 7 | (ii) Supply of End plate compatible to above screwless terminals. The end plates shall be of different colour than that of disconnect terminal blocks. |
| 8 | (iii) Supply of Din rail of dimension 35mm x 7.5mm, 1 mm thickness, 1Mtr length, slotted compatible to above terminals . |
| 9 | iv) Supply of End Stop 10mm for above Din 35 Rail . |
| 10 | Supply of Resettable fuse, type Polymeric Positive Temperature Coefficient (PPTC) Fuse of make Littlefuse/Fuzetec,/Tyco/ Bourn/Raychem. Rating of fuse will be provided by consignee as per site requirement. |
| 11 | Supply of Earth Electrode assembly as per Drg. No. S&T/CON/KOTA/EARTHING/01 ALT - 01. All nut, Bolts & Lugs to be of stainless steel. The earth electrode pipe shall be 'B' Class/ Medium Grade as per Specification No. IS: 1239 Pt. 1/ 2004 or latest. |
| 12 | Supply of Hylem sheet resin bonded 10mm thick, grade P3 in standard size of 1.22X1.22 Mtr as per Spec. No. IS 2036 of 1974. (Material inspected by Consignee) |
| 13 | Supply of Tag Blocks 200 way with cover as per IRS: S- 77/2006 (Rev. 1) with latest amendment and Drg No. SA-24751. (Material inspected by RDSO) |
| 14 | \\"Supply of Hand held true RMS Digital Multimeter Make: Fluke/Rishabh/Stanlay. Model: Rishabh 616 or superior which can measure voltage in m Volts.\\" |
| 15 | Supply of HDPE duct 40/33 MM as per TEC GR/CDS/08-02 NOV- 04 along with following accessories (to be procured from RCIL approved sources) |
| 16 | Supply of HDPE duct 40/33 MM as per TEC GR/CDS/08-02 NOV- 04 along with following accessories (to be procured from RCIL approved sources) End plug |
| 17 | Supply of HDPE duct 40/33 MM as per TEC GR/CDS/08-02 NOV- 04 along with following accessories (to be procured from RCIL approved sources) Cable sealing plug |
| 18 | Supply of HDPE duct 40/33 MM as per TEC GR/CDS/08-02 NOV- 04 along with following accessories (to be procured from RCIL approved sources) Plastic coupler |
| 19 | Supply of Double Walled Corrugated (DWC) pipe made up of High Density Poly Ethylene (HDPE) of size 103/103.5 mm inner dia and 120 mm outer dia in 6 Mtr straight length as per Britsh Standard No. BSEN 50086-1 and BSEN 50086-2-4 and BIS draft Specification Doc No. ETD 14(5071) and ETD 14(5072) along with one coupler per every 6 meters. |
| 20 | \\"Supply of DC-DC converter of various ratings like 24- 40V/10A, 24-32V/5A, 60- 66V/5A, 60-100V/1A for integrated power supply system (IPSS) as perSpecification no:RDSO/SPN/165/2023 VERSION 4.0 with Amend 1 with Amend 1 Prior approval of engineer incharge shall be taken before supply of material for the make & quantity break-up of DC-DC converters to be supplied as per site requirement. \\" |
| 21 | AC/DC Clamp Meter Model 3540 (KOICO Make) |
| 22 | Supply of Digital earth clamp tester for measurement of earth resistance. Make - Motwane Model DECT-3/ FLUKE Model-1630/ MECO Model- 4680 BLC/ KY KYORIT ORITSU Model-4200.SU Generalized Specilication for Portable Digital Earth Clamp Meter is as under:- SN. Parameters Characteristics l.Resistance measurement range--O.Ol Ohm to l2OO Ohm.2.Current Measurement Range--0 to 2O A, 3.Display--4 digrts 9999 count LCD, 4.Resolution Range-- O.OO1 Ohm to 30 Ohm,5.Accuracy- +/-( I percent+ 0.01 Ohm to +/-(25 percent+30 Ohml,6.Conductor size -- 23mm approx / 35mm approx, 7.Jaw size --65mm x 32mm, 8.Instruction manual-To be provided, 9.Computer interface - RS 232,US8, 10.Environmental- Working temperature: 0 deg to 50 deg, Humidity less than 85 percent RH. 11.Memory Storage Facility-99 records 9(i) loop resistance with no inductive, external magnetic field-- < 50 A /m 9(ii) External electric field - <1 V/m,10.Power Source-6 v DC (4x1.5 V AA alkaline batteryl, 12.Single measurement / Sampling time- 0.5 second, 13.Sound and light enunciator- Beep sound, Flashing Symbol, AL Key to turn on - off and setting the sound and light alarm, 14.Overload Indicator- -\\"OL\\" on display, l5.Overload Protection - 100A [Continuous],200A[5 sec], 16.Low battery indication- Display Symbol, 1 7. Range Selection- -Auto, 18,Single Measurement time-0.5 sec. (Inspection by Consignee) |
| 23 | Installation of High frequency Digital Axle Counter Multi Section type complete system including central evaluator(s), final track clearance relay for each track section, Reset boxes, LV boxes, detection points, mushroom housing for track side electronics, and all other accessories fully wired to the ultimate capacity and fully equipped to the configuration specified as per RDSO's specification No. RDSO / SPN / 176 / 2013 (ver. 3) or latest and OEM specification. NOTE: Spares of 10% shall also be supplied as per RDSO specifications.This 10% spares are shall not be merged with ITEM No. 24 Sypply schedule. This also includes Installation of track device (double rail contact) including digging of trench, fixing of deflector plates, track crossing, laying of ant rodent, anti-oxidant & non -flame propagating type double walled corrugated (DWC) pipe made up of high density polyethylene of required dia, as per IS-14930 part-I OR II or latest and all other accessories as per site requirement for laying of transmitter and receiver cable, installation of EJB/track side electronics including foundation & installation of earthing (if any) as per OEM's guidelines, technical requirement & specification. The item unit will be per DP |
| 24 | Preparation of Cable Route Plan, Cable Coreage Plan, Location & CT Rack/ Relay Rack Particulars, Cable Meggering Report, Earth resistance particulars, Track Circuit jumper/ bonding Diagram, Traction Bonding diagram, Block cicuit wiring diagram and any other drawing on Auto- CAD in A2/A3/A4, etc. size (as per instruction of engineer incharge) in Pen Drive with Soft Copy of Coordinates in Google Earth File (KMZ) along with permission(if required) to alter this file to railway representative for future variations . The basic rough sheets shall be prepared by Site Engineer of contractor in consultation with Railway Supervisor for preparation of above mentioned plans/reports. Thereafter the contractor shall prepare the same in Auto- CAD in A2/A3/A4, etc. size (as per instruction of engineer incharge). Initially contractor shall supply 2 sets of documents complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/ corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects along with its soft copies and 4 sets of final completion drawings properly bound in steel clip jaw with cushion cover in poly thin Bags (02 Sheets in each bag) to railways. |
| 25 | Preparation and supply of Detailed Signalling Circuits including wiring diagrams ( as per existing Interlocking), Fuse & Negative Tag Analysis, Contact Analysis, Selection and Locking Tables, Relay Rack Arrangement, Signal interlocking plan, Route section plan & control panel/VDU diagram, SWR & SWRD as per size specified in IRSEM, Completion circuit shall be plotted in Auto cad. The contractor shall initially supply 2 Set of Hard Copy of circuits duly signed by the contractor having substantial experience on design side for making such circuits complete for approval of Railways. Railway will return circuit to the contractor duly approved with alterations/ corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the original tracings & Pen drives without any deviation and submit original tracing of the modified circuits & final Pen drive complete in all respects along with 6 sets of final approved circuits along with auto c a d copy (out of which tracing shall be supplied in transparent polythene bags in Ring binder folder. Only two sheets of circuits shall be placed in one polythene bag/cover each) shall be submitted to the railways in case there are no further alteration suggested by Railways. (1 unit = 1 station\\"The item unit will be Per stn |
| 26 | Installation of Relay Rack Assembly including IDF pillar if any complete with wall supports, scaffolding insulated ladders, runway for cables, Relay/Relay group base plates, fixing of Tag block etc. The work shall be done as per approved plan, extant practice on W. C. Railway & the instructions of Rly. engineer at site with contractor's own materials as per typical rack arrangement Drg. No. Sr. DSTE (W)/ S&T/PI/14. |
| 27 | Installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminal/Wago terminal & other necessary accessories etc. The work shall be done as per approved plan, extant practice on W. C. Railways & the instruction of Rly. engineer at site. (Proper writting of all indoor gears) |
| 28 | Supply, Installation, fixing, wiring, testing & commissioning of MSDAC Indication/Alarm panel system. It shall consist of 200 LEDs of 10mm size fabricated in a box of 15mm waterproof ply.The item unit will be Per Cabin |
| 29 | Fixing of Q series relay base plate/ Metal to Metal relay mini group and major group base plates, laying, lacing, dressing & packeting of 60/40/24 core PVC indoor cable and termination of 60/40/24 core cable on tag block & base plates & its soldering. Wiring of circuits to be done as per the approved diagram based on relay interlocking system using metal to metal/metal to carbon type relays and soldering after testing. This also includes fuse wiring, function wiring (Including inter connection between relay rack, & CT rack), power supply wiring (power wiring from power supply distribution board / rack to relay racks and cable termination racks with provision of wiring of ring connection with the help of contractors own single core flexible multistrand copper wire of 16 sq mm and 10 sq mm as per RDSO specification no. IRS-S 76/89 with latest amendment. 16 sq mm wire for All 110V DC, 110V AC & 60V DC internal supply and 10 sq mm wire for balance supply is to be used) Materials required like jumper wire of 0.6 mm, 1.0 mm, 16/0.02 multistrand flexible etc, resin core, solder wire, lacing thread, adhesive tapes resistance, condensers, diodes, lugs etc of various ratings and capacity as per site requirement to arranged by the contractor free of cost and used after approval of Rly engineer at site. The jumper wire of 0.6mm, 1mm , flexible wire of 16/0.02, power wire of 16 & 10 sqmm equired for carrying out the indoor work shall be supplied by contractor as per RDSO specification no. IRS-S 76/89 with latest amendment after RDSO inspection. The quantity of jumper wire should be assessed jointly with the engineer in charge in beginning itself.). The work shall be done as per approved plan extant practice on W. C. Rly & the instruction of Rly engineer at site. Required quantity of 60/40/24 core PVC indoor cables will be supplied by Railway. Inspection will be done by RDSO/RIETSThe item unit will be Rack |
| 30 | Alteration,Augmentaion & upgradation in data logger wiring, testing & commssioning of Data logger complete along with accessories with contractors own material. This include programming of data logger for fault diagostic in suitable structured language in consultation with RailwayThe item unit will Per Station |
| 31 | Supply of Cabinet with wiring arrangement of DC-DC converter for 08 No. suitable for make of existing IPS. Material to be inspected by Consignee |
| 32 | Excavation and Casting of Apparatus Case Foundation with mixture of Cement:Sand:Stone aggregate/Chip in 1:3:6 ratio and plastering with mixture of Cement:Sand in 1:4 ratio, with contractors own Metal Sheet ferma of the size mentioned in the drawing, cement, anchor bolts, with nuts & washers and other materials. The items also include additional earth work if required as per instruction of Rly. Engineer at site. All nuts, bolts and washers etc. should be galvanised iron. Single Case as per Drg. No. Dy.CSTE/C/Kota/2. |
| 33 | Erection of Apparatus cases. This includes filling of Location Foundations with the seived sand being used for making the foundation of location boxes and plastering on top of the sand. All nuts, bolts and washers etc. should be galvanised iron. Single case. |
| 34 | Supply, fabrication and fixing of Phenolic Laminated Sheet Board in Location Box by providing all fixtures, double ended insulators (06 Nos.), PVC coated string rods at the back side for cable support with contractor's own material. The work shall be done as per Drg. No. SK783-1/2 with latest alterations & as per instructions of Railway Engineer at site. The Phenolic Laminated Sheets should be of 10mm thick, grade P3 as per specification No. IS: 2036 of 1995 or latest. The size of the Phenolic Laminated Sheet for Full Case terminal board should be 800mm x 950mm and for half case it should be 800mm x 450mm. In case board size is in variation with the size mentioned as per location details, then proportionate payment on area basis shall be made. This also include, the work to be done in existing Location Boxes (if required) as per instructions of Railway Site Engineer. Single case. |
| 35 | Supply, fabrication and fixing of Phenolic Laminated Sheet for Shelf of equipments/batteries with contractor's own fixing material, angle frames, additional in-between supporting angle for the Shelf, etc. The work shall be done as per Drg. No. SK 783-1/2 with latest alterations & as per instructions of Railway Engineer at site. The Phenolic Laminated Sheets should be 10mm thick, grade P3 as per specification No. IS: 2036 of 1995 or latest. The size of Shelf for Single Case Apparatus/Location Box shall be 500mm x 950mm and for Half Case Location Box it shall be 500mm x 450mm. In case board size is in variation with the size mentioned as per Location details, then proportionate payment on area basis shall be made. Galvanised nut & bolts to be used for fixing of Phenolic Laminated Sheets. Single caase. |
| 36 | \\"Installation of Equipments (Relays, Resistance, chargers, Choke, batteries, LV box, KLCR, PPTC fuses & track feed charger alarm unit, etc. as applicable) with contractor's own wiring material, MS frame, copper lugs etc. & wiring of the same in Apparatus Cases as per Location Diagrams, paralleling of spare contacts of Metal to Carbon Relays and wiring of potential free contact of track feed charger and testing of track circuits as per instruction of Railway's Site Incharge and standard practice. This also includes supply of Multi-strand Flexible Single Core Copper Wire 2.5 sq.mm (50/0.25) except for relay wiring which will be done with 16/0.2 mm flexible multi-strand wire conforming to IS: 694:1990 with suitable lugs. All wires to be duly manufactured by RDSO approved firms (16/0.2 mm flexible multi-strand wire inspected by RDSO). Note: PPTC fuses shall be provided as per fixing arrangement of PPTC as advised by HQ's policy guideline issued vide letter no. WCR/N-HQ/110/Signal Policy/Sig-32 Pt-VII, dtd. 07.11.2013 i.e. PPTC fuse are to be connected with crimped ring type lugs and crimped area is also to be filled with solder. PPTC lead to be provided with ferrules for volt & current rating of PPTC. Single case.\\" |
| 37 | Fixing of ARA/cage type disconnect terminals and fuse blocks with provision of holes on Phenolic Laminated Sheets and fixing with galvanised nuts & bolts in Location Boxes and elsewhere. This includes provision of additional holes on the Phenolic Laminated Board on either side for cable conductor entry. The work shall be done as per the instructions of Railway Engineer at site. |
| 38 | Termination of cable cores on ARA Terminals/cage type disconnect terminals, fuse blocks, 8-way terminals blocks, telecom terminals in new/existing apparatus cases, existing MCTB/existing telecom cable termination racks. This includes all associated works of pulling out the cable from underground, dressing of cable, making wiring tree with contractor lacing & threading material etc. Both ends of a cable core shall be counted as per conductor. This includes soldering of armour tree/ring of cables and connecting to copper plate through GI wire bus bar in location boxes. The work shall be done as per instructions of Railway Engineer at site. |
| 39 | Supply & Fixing of lamp holders (two pin) with switches (ISI mark) of reputed make for location boxes. This also includes supply of bulb of reputed make. |
| 40 | Installation of earth electrode assembly as per Drg. No. S&T/CON/Kota/Earthing/01 ALT-1 and connecting through stainless steel wire 8 SWG supported on MS flat of size 5mm x 40mm to earth electrode as per Drg. No. T/2014/1 for signals and T 2014/5 for Location Boxes/Apparatus Cases. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Railway Supervisors. It should be documented and painted on earth enclosure made of concrete. Only earth electrode will be supplied by Railway. All other material required for provision of earthing will be brought by the contractor. This earth can be provided for DPs, block instruments & ELD etc. also, so as to achieve the desired earth resistance value. Earth enclosure to be manufactured & supplied by contractors own material of ratio 1:3:6, without cover. Additional connection of Earth pipe including parallel connection with other earth pipes with the function shall be done using left over pieces of signalling cable. Laying of cable pieces shall be covered in laying of cable item and cable shall be supplied by Railways. |
| 41 | Excavation of trench 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, including clearing of bushes, trees etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. The work also includes excavation of trenches in the beds of culverts. Whenever the dimensions of cable Trenches as mentioned in the Tender Schedule are not easily achievable due to terrain conditions, then payments will be made on a pro-rata basis, for the dimensions achieved.The specific approval of the Engineer in charge of the work (not below the rank of Sr. Scale officer), will be required for such dispensation. |
| 42 | Excavation of cable trench 300mm wide at the bottom and 1.2 meter deep in hard soil mixed with bolders / hard murum soil including clearing of trees, bushes and refilling of cable trench by excavated soil, murum, bolders etc. Care should be taken while refilling the cable trench such that the murum / bolders etc. does not damage the cable. Ramming after laying of cable (a) 6- quad (b) jelly filled & power cables etc. Whenever the dimensions of cable Trenches as mentioned in the Tender Schedule are not easily achievable due to terrain conditions, then payments will be made on a pro-rata basis, for the dimensions achieved.The specific approval of the Engineer in charge of the work (not below the rank of Sr. Scale officer), will be required for such dispensation. |
| 43 | Excavation of cable trench 1.0m deep from the rail flange and 300mm wide across the track, for track crossing and refilling after laying of RCC/ GI/ DWC pipes and restoring the track to its original condition. Generally there shall be no proportionate payment for cable at depth lesser than that specified in the tender schedule. If it is not possible to reach the required depth at any location, then the contractor shall obtain approval of Railway Site Engineer, who shall get the dispensation, from JAG vide Rly. Board's letter No. 2013/Sig/SEM Pt.-II/Misc., dated 12.06.2014 before commencement of cable laying process and only then shall the proportionate payment be made to the contractor. The work shall be done as per extant practice on W.C. Railway & instruction of Railway Engineer at site. Cable trench as per Drg.No. TS/Cable laying/12/03/03 Alt.-1. For achieving 1.0 Mtr depth for the bottom most cable, the contractor shall dig the trenches to a depth, slightly more than 1.0m to take care of practical problems. Laying of RCC/GI/DWC pipe and cables is covered in separate item. |
| 44 | All work pertaining to Horizontal Dirctional Drilling (HDD)/Boring and trenchless cabling. It includes supply, transportation and insertion of self lubricated HDPE Pipe and laying of cables in boring under the track/road/platform/circulating area by using different sizes of pipes depending on total number of cables will be crossed. The depth of horizontal boring should be minimum 1 mtr upto 3 mtr, from rail flange/ road level/ground level as per site requirement and as per instructions of Railway Engineer incharge. This item will be used for track crossing of running lines, road crossing & circulating area. By using self lubricated HDPE Pipe of 120mm outer dia and 103.5mm inner dia in the bore and laying of cables in the bore under the track/road/circulating area. |
| 45 | Preparation of cable duct 150mm x 300mm deep for laying of cables in rocky area and refilling the duct (after cable laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with contractors own cement and other materials. Cable trench shall be as per Drg. No. Dy.CSTE/C/Kota/07/A. Laying of cables is covered in separate item. |
| 46 | Supply & laying of well burnt bricks of size 200mm x 90mm x 65mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable & covering of cables laid in trenches by loose excavated soil for a layer of 50mm thickness approximately, in station area from Outermost to Outermost signal or at any other location as per instruction of Site Engineer. Note:- Size of bricks to be got approved by Railway Site Engineer. In case brick size is in variance with the size given in the tender schedule then proportionate payment on volumetric basis shall be paid to contractor subject to a maximum limit of schedule rate. |
| 47 | Laying of All types of Signal/ Telecom/ Power Cable of various cores/ sizes in excavated trenches. The work shall be done as per extant practice followed on W.C. Railway and as per the instructions of Railway Engineer at site. |
| 48 | Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site. |
| 49 | Modification/Shifting of existing track device: Installation of track device(double rail contact of digital axle counter) includes digging of trench, track crossing, laying of Double walled antirodent corrugated pipe from trackdevice to location box and making its terminations.Fixing of deflector plates. (Double walled antirodentcorrugated pipe made up of High Density Polyethylene of required dia and all other accessories as per site requirement to be supplied by thefirm) this also includes supply of HDPE pipes for laying of transmitterand receiver cables for rail contactsto location box. Casting of foundation for track side housing & erection oftrack side housing if required.Installation & wiring of EJB / Trackside Electronics inside the track sidehousing (this housing will be suppliedand installed on foundation by thecontractor with his own material)including supply of wires and other accessories. This also includes releasing of existing track device & EJB from site, painting and writing on detection points and track side housing covers. This also includes OEM pre-commissioning check list. |
| 50 | Circuit wiring/ jumpering as per diagram in the relay rack/IDF rack/tag block. This include preparation of jumper sheet duly checked by firm's site supervisor & wire to wire testing as per wiring diagram.Any wrong jumper done by wire man will be consider & payment for wrong jumper will not be done by the railway. Jumper wire will be supplied by railway & other material like solder wire will be supplied by contractor. Unit- per jumper |
| 51 | Supply, fixing, painting and installation of RCC cable route markers as per drawing No. DRM/KOTA/MISC-87. Placing and securing of cable route markers in trenches at the specified interval and diversions, joints etc along the cable route. The work shall be done as per extant practice on W. C. Rly & the instructions of Rly engineer at site. Sample to be approved by engineer in-charge of the Railways before supply, after the testing prescribed in drawing.This includes supply of Paints of different colours as per drawing. The paint shall be either from Asian or Shalimar / Apcolite / Berger having ISI mark. |
| 52 | \\"Painting two coats of Enamel Paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints with ISI mark is to be supplied by the Contractor. The work shall be done as per instructions of Railway Engineer at site and extant practice on W.C. Railway. Note: Second coat shall be made after completely drying up of first coat of paint, to give good somooth & lasting finish. Apparatus case full size.\\" |
| 53 | Lettering, numbering of point machine, track lead junction boxes, block joint, glued joints, , batteries, apparatus cases etc. (outside) (each item to be taken as one unit ) |
| 54 | Lettering & numbering of termination particulars, equipments names etc. legibly and neatly inside Location Boxes as per standard practice of W.C. Railway & instructions of Railway Engineer at Site. Single case. |
| 55 | Cement concrete 1:3:6 in foundations with upto 25mm graded stone aggregate as per instructions of Railway Engineer at Site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender