Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #56434909

Tender For Repair Replacement Of Poles Busbar Chambers Ug Cables Fittings And Connected Misc Wks At Army Area Under Ge Avadi

Issued by Statutory Bodies & Commissions/Committees · Thiruvallur, Tamil Nadu
Tender Value
45 Lakhs
Estimated cost
Bid Submission
29 Jul 2026
12 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Replacement Of Poles Busbar Chambers Ug Cables Fittings And Connected Misc Wks At Army Area Under Ge Avadi

BOQ

Name of Work:- REPAIR REPLACEMENT OF POLES BUSBAR CHAMBERS UG CABLES FITTINGS AND CONNECTED MISC WKS AT ARMY AREA UNDER GE AVADI
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out any type of soil for laying cables / pipes / erection of poles etc complete all as specified and as directed.
2Excavation in trenches in soft/ loose soil not exceeding 1.50 m wide and exceeding 1.50 m in depth but not exc 3 mtr in depth for foundation of poles, stay, cable, pipes etc and getting out complete all as specified.
3Supply and laying of common burnt clay building bricks, sub class B size for cable protection complete all as specified and as directed.
4Laying in trenches fine sieved excavated dry soil including spreading/leveling, cushioning for underground cables complete all as specified and as directed.
5M&L for PCC (1:4:8) type D2,( using 40 mm graded aggregate) as in foundations, filling and mass concrete Complete all as specified and directed.
6M&L for PCC ( 1:2:4) type B1 using 20 mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface complete all as specified and as directed.
7Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each complete all as specified and as directed.
8Removing excavated material(soil)not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
9Material and labour for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, 3.5/4 in replacement of the following sizes cross-sectionl area including taking down of old unserviceable cable/OH line ACSR conductor of any type complete all as specified and as directed:- (Note: Earth work and connected items will be measured and paid separately under respective items of schedule)(a) 10 sq mm 2 core
10(b) 16 sq mm 4 core
11(c ) 25 sq mm 4 core
12(d) 35 sq mm 3.5 Core
13(e) 50 sq mm 3.5 Core
14(f) 70 sq mm 3.5 Core
15(g) 95 sq mm 3.5 Core
16(h) 120 sq mm 3.5 Core
17(j) 185 sq mm 3.5 Core
18Taking out from trenches/poles/wall etc LT XLPE UG Cable /PVC Sheathed aluminium conductor armoured and relaying / rerouting after fault rectification duly tested in trenches/Poles/Wall of following sizes : (Note: Earth work and connected items will be measured and paid separately under respective items of schedule)(a) LT UG Cable 4 core 16 Sqmm
19(b) LT UG Cable 3.5/ 4 core 25 Sqmm to 3.5 core 50 Sqmm
20(c) LT UG Cable 3.5 core 70 Sqmm to 3.5 core 120 Sqmm
21(d ) LT UG Cable 3.5 core 150 Sqmm to 3.5 core 185 Sqmm
22Supply and Fixing of Straight through joints heat shrink type for underground cable suitable for LT XLPE/ PVC sheathed/ armoured heavy duty cables with aluminium conductor all as specified and as directed of following sizes:-(a) 3.5/ 4 core, 16 sqmm to 50 sqmm
23(b) 3.5/ 4 core, 70 sqmm to 120 sqmm
24(c) 3.5/ 4 core, 150 sqmm to 185 sqmm
25Material and labour for GI tubing light grade for cable protection laid in trenches in road crossing or fixed to wall/Pole of following sizes including taking down old unserviceable one complete all as specified and as directed. (a) Bore of tube 40mm
26(b) Bore of tube 50mm
27(c) Bore of tube 80mm
28M&L for replacement of old unsv Bus bar chamber and Supply ,Fabricate, install, connect, test and commissioning Busbar chamber, powder coated, outdoor weather proof type, compartmentalised fabricated with 3 mm thick CRCA steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit , chamber for aluminium busbars, separate compartment for switch gear, louvers and air vent for natural air flow, holes drilled for connection including suitable angle iron/flat iron frame work/ supports, excavation, earth work, PCC foundation etc., as required with and including following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including taking down the old busbar chamber and demolition of old plain cement concrete complete all as specified and comprising of the followings:- (i) 4 Nos busbar of equal size of Aluminium conductor with PVC coloured heat shrinkable type sleeves continuous rating of 400 Amps mounted on fibre reinforced insulator.(1set), with LED indication lamps-03 Nos for RYB phases on incoming side. (ii) MCCB fixed thermal magnetic release type of capacity 200 amps, 4 pole, 36 kA.- 1 Nos.
29M&L for replacement of olf unsv bur bar chamber and Supply ,Fabricate, install, connect, test and commissioning Busbar chamber, powder coated, outdoor weather proof type, compartmentalised fabricated with 3 mm thick CRCA steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit , chamber for aluminium busbars, separate compartment for switch gear, louvers and air vent for natural air flow, holes drilled for connection including suitable angle iron/flat iron frame work/ supports, excavation, earth work, PCC foundation etc., as required with and including following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including taking down the old busbar chamber and demolition of old plain cement concrete complete all as specified and comprising of the followings:- (i) 4 Nos busbar of equal size of Aluminium conductor with PVC coloured heat shrinkable type sleeves continuous rating of 400 Amps mounted on fibre reinforced insulator.(1set), with LED indication lamps-03 Nos for RYB phases on incoming side. (ii) MCCB fixed thermal magnetic release type of capacity 200 amps, 4 pole, 36 kA.- 1 Nos. (iii) On load change over siwtch 200 Amps ,4 pole 415 volts ,3 phase ,50 Hz AC - 01 NoNote : MCCB shall be front handle operated.
30M&L for fixing in replacement of Aluminum Bus Bar having current rating 400 Amp duly insulated with colour coding RYB and Black all as specified and as directed including making holes on the bus bar for making necessary connections complete all as specified and as directed.
31M&L for fixing in replacement of Aluminum Bus Bar having current rating 600 Amp duly insulated with colour coding RYB and Black all as specified and as directed including making holes on the bus bar for making necessary connections complete all as specified and as directed.
32Supply & fixing in replacement Ammeter meter 100x100mm 0- 200 amps of CT ratio 100/5, Digital type volts includind all electrical connection ccomplete all as specified and as directed.
33Supply & fixing in replacement Ammeter meter 100x100mm 0-4000 amps of CT ratio 100/5, Digital type volts includind all electrical connection ccomplete all as specified and as directed.
34Supply & fixing in replacement Voltmeter meter 100x100mm 0-500 Volts, DIgital type volts in cludind all electrical connection complete all as specified and as directed.
35Repair to the existing LT panel board/Bus bar chambers/Pole loop boxes for disconnecting faulty/burnt portion of cable and preparing fresh terminals with suitable size of new aluminium lugs,bolt, nuts and washers suitable for size of cable from 4/3.5 core x 10 Sqmm to 50 Sqmm by taking down the old burnt/rusted lugs, bolts , nuts and washers in necessary quantity as per site requirment including cleaning the busbars, provision of insulation sleeves to busbars where ever required complete restore electrical connection complete all as specified and as directed.
36All as per above item but size of cable 3.5 core x 70 sqmm to 240 sqmm complete all as specified and as directed.
37Cutting/clearing and removing the vegetation/bush/creepers growth any nature/type around/on the electric panel/feeder pillar box/busbar chamber so as to keep clean the area for easy access to carry out repair/maintenance works in electric panel/feeder pillar box/busbar chamber etc, removing from site and throwing out at a place where directed at distance not exceeding 250 mtr away complete all as specified and as directed.
38Removal of UNSV PCC/Steel pole and M&L for steel tubular swaged poles complete with cast iron base plate final taper plug bolts, nuts & screw all as specified and directed Type 410 SP 31 (9 Mtr long) with two coat of aluminium paint over a coat of red oxide primer in full length of the pole with black and yellow strip up to 1.5 mtr over PCC coping alternatively including numbering the pole and necessary excavation incl dismantling the unserviceable pole etc complete all as specified and directed.(Note: Excavation, demolition of concrete, PCC for foundation, coping and connected items shall be measured and paid separately under relevant items) Please Enable Macros to View BoQ information
39Removal of UNSV PCC/Steel pole and M&L for steel tubular swaged poles complete with cast iron base plate final taper plug bolts, nuts & screw all as specified and directed Type 410 SP 31 (9 Mtr long) with two coat of aluminium paint over a coat of red oxide primer in full length of the pole with black and yellow strip up to 1.5 mtr over PCC coping alternatively including numbering the pole and necessary excavation incl dismantling the unserviceable pole etc complete all as specified and directed.(Note: Excavation, demolition of concrete, PCC for foundation, coping and connected items shall be measured and paid separately under relevant items) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56434909
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 29-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair Replacement Of Poles Busbar Chambers Ug Cables Fittings And Connected Misc Wks At Army Area Under Ge Avadi
Basic Detail
Tender No 8446/E8
Bidding Type Tender
Location
City Thiruvallur
State Tamil Nadu
Key Dates
Publish Date 13 Jul 2026
Submission Date 29 Jul 2026
Open Date 31 Jul 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
8446NIT.pdf
a5159fc5-264e-40fb-9914-c6d98961870d.html
BOQ_871471.xls
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Jul 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

8446NIT.pdf

html

a5159fc5-264e-40fb-9914-c6d98961870d.html

xls

BOQ_871471.xls

pdf

Tendernotice_1 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders