Tender For Supply, Erection, Testing, Commissioning Of 1X100kva And 1X63kva, 11/0.415Kv Distribution Substations Along With Ht/Lt Line For Electric Vehicle Charging Station (Evcs) On Turnkey Basis Under The Jurisdiction Of Executive Engineer Ed-Ii Jp
Tender Overview
Project Description
Tender for Supply, Erection, Testing, Commissioning Of 1X100kva And 1X63kva, 11/0.415Kv Distribution Substations Along With Ht/Lt Line For Electric Vehicle Charging Station (Evcs) On Turnkey Basis Under The Jurisdiction Of Executive Engineer Ed-Ii Jpdcl, Jammu At Following Locations:1. 1X63kva Along With Ht Line On 50Mmsq Xlpe Cable At M/S Prakash Oil Company, Industrial Area Gangyal, Jammu2. 1X100kva Along With Ht/Lt Line On 95Mmsq Xlpe Cable At Hemkund Gas Station, Railway Road, Jammu
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer Electric Division-II JPDCL Jammu Name of Work: \\"Supply, Erection, Testing, Commissioning of 1x100KVA and 1x63KVA, 11/0.415KV distribution substations along with HT/LT line for Electric Vehicle Charging Station (EVCS) on Turnkey Basis under the jurisdiction of Executive Engineer ED-II JPDCL, Jammu at following locations:1. 1x63KVA along with HT line on 50mmsq XLPE Cable at M/S Prakash Oil Company, Industrial Area Gangyal, Jammu2. 1x100KVA along with HT/LT line on 95mmsq XLPE Cable at Hemkund Gas Station, Railway Road, Jammu” Contract No: e-Nit No 22 of 2026-27 Dated: 11-07-2026 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # |
| 2 | Item Description |
| 3 | Supply, Erection, Testing & commissioning for creation of 11/0.415KV, 63KVA, 3-phase Distribution Substation for EV Charging Station at M/S Prakash Oil Company, Industrial Area Gangyal, Jammu |
| 4 | Supply, Erection, Testing & commissioning of 11/0.415kV, 63 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) with LV Cable Box having detachable Aluminium Gland plate. (As per Latest Ammendment upto date) |
| 5 | Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface. |
| 6 | Supply, Transportation, Fabrication & Fixing of G.I Channel Iron, Cross arms, Angle Iron Braces, Clamps etc. duly fabricated including all necessary G.I Nut & Bolts & Washers etc. |
| 7 | Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 8 | Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 9 | Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA, LA with polymer housing, Stn. Type |
| 10 | Providing & fixing of PVC Cable 120 mm² along with 12 Nos Al. Thimble of 120 mm² |
| 11 | Providing & Fixing of LT Distribution Box for 63 kVA DTR with 100A MCCB for incomer & SFU’s for Outgoing Circuits including Busbar arrangements for Phases & Neutral of EC Grade Aluminium, PVC Insulated Sleeved Busbar of required load handling capacity with colour code for Phases and Neutral differentiation, including Aluminium thimbles of required sizes for proper termination etc. |
| 12 | Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 Mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 13 | Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 14 | Providing & fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 15 | Providing & fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 16 | Wedge Connectors / PG Clamps |
| 17 | Providing & Fixing of Anti Climbing device with Clamps |
| 18 | Providing & Fixing of Danger Plates with Clamps |
| 19 | Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete |
| 20 | Supply, Erection, Testing & commissioning for laying of 11KV line on 50mmsq XLPE Cable on 8 Mtr ST poles for EV Charging Station at M/S Prakash Oil Company, Industrial Area Gangyal, Jammu |
| 21 | Supply, Erection, Testing & Commissioning of 8 Mtr Long ST Poles including Transportation to erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 22 | Supply, Transportation, Fabrication & Fixing of GI Channel Iron, GI Clamps etc duly fabricated including all necessary GI Nut & Bolts & Washers etc. |
| 23 | Supply, Laying & Stringing of 50mmsq HT XLPE Cable through Suspension/Tension Clamps and Straight through Cable joint Kits |
| 24 | Suspension/Tension Clamps |
| 25 | Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 26 | Providing & Fixing of Danger Plates with Clamps |
| 27 | Providing & Fixing of Anti-Climbing Device with Clamps |
| 28 | Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 29 | Providing & Fixing of Stone Pad (300 mm x 300 mm x 75 mm) |
| 30 | Red Oxide |
| 31 | Al. Paint |
| 32 | Providing & installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete |
| 33 | Supply, Erection, Testing & commissioning for Installation of Prodigy Meter for EV Charging Station at M/S Prakash Oil Company, Industrial Area Gangyal, Jammu |
| 34 | Prodigy Meter along with cables and accessories |
| 35 | Supply, Erection, Testing & commissioning for creation of 11/0.415KV, 100KVA, 3-phase Distribution Substation for EV Charging Station at Hemkund Gas Station, Railway Road JDA-04 feeder, Jammu |
| 36 | Supply, Installation & commissioning of 11/0.433kV, 100KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2,2, \\"BIS Marked\\" (Aluminium Wound) (Aluminium wound) with LV Cable Box having detachable Aluminium Gland plate.(As per latest Amendments and IS) |
| 37 | Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface. |
| 38 | Supply, Transportation, Fabrication & Fixing of G.I Channel Iron, Cross arms, Angle Iron Braces, Clamps etc. duly fabricated including all necessary G.I Nut & Bolts & Washers etc. |
| 39 | Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 40 | Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 41 | Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA, LA with polymer housing, Stn. Type |
| 42 | Providing & fixing of PVC Cable 185 mm² along with 12 Nos Al. Thimble of 185 mm² |
| 43 | Providing & Fixing of LT Distribution Box for 100kVA DTR with 160A MCCB for incomer & SFU’s for Outgoing Circuits including Busbar arrangements for Phases & Neutral of EC Grade Aluminium, PVC Insulated Sleeved Busbar of required load handling capacity with colour code for Phases and Neutral differentiation, including Aluminium thimbles of required sizes for proper termination etc. |
| 44 | Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 Mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 45 | Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 46 | Providing & fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 47 | Providing & fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 48 | Wedge Connectors / PG Clamps |
| 49 | Providing & Fixing of Anti Climbing device with Clamps |
| 50 | Providing & Fixing of Danger Plates with Clamps |
| 51 | Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete |
| 52 | Supply, Erection, Testing & commissioning for laying of 11KV line on 95mmsq XLPE Cable on 8 Mtr ST poles for EV Charging Station at Hemkund Gas Station, Railway Road JDA-04 feeder, Jammu |
| 53 | Supply, Erection, Testing & Commissioning of 8 Mtr Long ST Poles including Transportation to erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 54 | Supply, Transportation, Fabrication & Fixing of GI Channel Iron, GI Clamps etc duly fabricated including all necessary GI Nut & Bolts & Washers etc. |
| 55 | Supply, Laying & Stringing of 95mmsq HT XLPE Cable through Suspension/Tension Clamps and Straight through Cable joint Kits |
| 56 | Suspension/Tension Clamps |
| 57 | Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 58 | Providing & Fixing of Danger Plates with Clamps |
| 59 | Providing & Fixing of Anti-Climbing Device with Clamps |
| 60 | Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 61 | Providing & Fixing of Stone Pad (300 mm x 300 mm x 75 mm) |
| 62 | Red Oxide |
| 63 | Al. Paint |
| 64 | Providing & installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete |
| 65 | Supply Erection, Testing and Commissioning for laying of LT line on 95mmsq XLPE cable on 8 Mtr Long PCC Pole (WL-250Kg) for EV Charging Station at Hemkund Gas Station, Railway Road JDA-04 feeder, Jammu |
| 66 | Supply Erection ,Testing and Commissioning of 8 Mtr Long PCC Pole (WL-250Kg) including Transportation to erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 67 | Supply, Laying & Stringing of 95mmsq LT XLPE Cable through Suspension/Tension Clamps and Straight through Cable joint Kits |
| 68 | Supply and Fixing of Galvanized Nuts and Bolts |
| 69 | Providing & Fixing of Danger Plates with Clamps |
| 70 | Providing & Fixing of Anti Climbing device with Clamps |
| 71 | Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 72 | Supply, Transportation, Fabrication & Fixing of GI Channel Iron, GI Clamps etc duly fabricated including all necessary GI Nut & Bolts & Washers etc. |
| 73 | Supply, Erection, Testing & Commissioning for Erection of isolation Point for Electric Vehicle charging station at for EV Charging Station at Hemkund Gas Station, Railway Road JDA-04 feeder, Jammu |
| 74 | ST Pole 9 mtr. Long |
| 75 | GI V Cross-arm with Top Bracket including Clamps |
| 76 | G.I Channel X-arm including Clamps and Braces |
| 77 | 11 KV GO Set |
| 78 | 50 mm Sq. ACSR Conductor |
| 79 | PG Clamps for 50 mm sq. ACSR Conductor |
| 80 | 11 KV Pin Insulators with Pins |
| 81 | 11 KV Disc Insulators with fittings |
| 82 | Galvanised Nuts & Bolts |
| 83 | Danger Plates with clamps |
| 84 | Anti Climbing Device with clamps |
| 85 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr. Long through GI Strip |
| 86 | Cement bottoming of poles |
| 87 | Red Oxide paint |
| 88 | Al. Paint |
| 89 | Guy Rod Complete |
| 90 | Supply, Erection, Testing & commissioning for Installation of Prodigy Meter for EV Charging Station at Hemkund Gas Station, Railway Road JDA-04 feeder, Jammu |
| 91 | Prodigy Meter along with cables and accessories Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 No Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender