Tender For Providing Electrical Works For Shifting Of Dgm Office In T.E Bldg. Township, Oa Mathura.
Tender Value
2.76 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
0 days left
EMD
5532
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mathura → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Electrical Works For Shifting Of Dgm Office In T.E Bldg. Township, Oa Mathura.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group A |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 4 | c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 5 | d) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 6 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 2 x 1.5 sq. mm |
| 7 | b) 4 x 1.5 sq. mm |
| 8 | c) 2 x 2.5 sq. mm |
| 9 | d) 2 x 4.0 sq. mm |
| 10 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm |
| 11 | b) 25 mm |
| 12 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. a) 5/6 amps switch |
| 13 | b) 3 pin 5/6 A socket outlet |
| 14 | c) 15/16 A switch |
| 15 | d) 6 pin 15/16 A socket outlet |
| 16 | e) 3 pin, 5 A ceiling Rose |
| 17 | f) Fan Regulator |
| 18 | Supplying and fixing metal box of 200 mm x 250 mm x 60 mm on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 19 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 20 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required. |
| 21 | Supplying and fixing extra down rod of 60 cm length G.I. pipe, 15 mm dia, heavy gauge, 2 x 60 cm length wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 22 | Providing ready made ceiling fan hook high quality with fastners i/c drilling , fixing in existing ceiling etc complete as required |
| 23 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection,testing, commissioning etc. as required. (a) Upto 450 mm sweep |
| 24 | Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all size |
| 25 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 26 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. A) Upto 35 sq. mm (Clamped with 1mm thick saddle) |
| 27 | b) Above 35 sq. mm and upto 95 sq. mm (Clamped with 25x3mm MS flat clamp) |
| 28 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5 X 35 sq. mm (32 mm) |
| 29 | b) 3.5 X 50 sq. mm (35 mm) |
| 30 | Rewinding of following existing electrical motors suitable for single / three phase, 240/415 volt 50 Hz AC supply i/c dismantling of faulty motor and re-installation after rewinding, testing, servicing, etc. complete as required. (Note: Dismantled copper wire shall be property of contractor, quote the rates accordingly) a) 1200/1400 mm ceiling fan single phase, 240 Volt |
| 31 | b) Exhaust fan single phase, 300 mm, 240 Volt |
| 32 | c) Exhaust fan single phase, 450 mm, 240 Volt |
| 33 | Supplying & fixing of following LED lights suitable for single phase, 230 Volts AC supply connection etc. complete as required. a) 30 Watt 1200 mm LED tube light fitting (Philips/Bajaj/Crompton Make) |
| 34 | b) 40/36 W. Flou. Tube (Philips/Bajaj/Crompton Make) |
| 35 | c) 40 W. Electronic Ballast (Philips/Bajaj/Crompton Make) |
| 36 | d) Starter for existing Fittings |
| 37 | e) Brass batten holder |
| 38 | f) 12 Watt LED Bulb |
| 39 | f) 3 mm Phenolic Laminated Sheet |
| 40 | Supplying & fixing of energy efficient 45 watt LED Street Light luminaire delivering>100 lumen/watt with PDC housing complete with all accessories on the existing pole i/c connection with 1.5 Sq. mm copper conductor single core cable etc. complete as reqd. (Make- Philips SmartBright Essential /Havells / Crompton make) |
| 41 | Providing ready made wall bracket for street light fitting for suitable size i/c fixing clamps, nut and bolts etc. as required. |
| 42 | Supplying and Laying of 2 x 1.5 sq. mm. copper conductor armoured cable PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade on surface / recess / ground etc as required |
| 43 | Supplying and fixing of following rating MCBs / Isolators in the existing MCB DBs Complete with connections, testing and commissioning etc. complete as required. (a) 6-32 Amp SP MCB (M/s Legrand make or SS make) |
| 44 | b) 32 Amp Double Pole MCB |
| 45 | c) 63 Amp Four Pole MCB |
| 46 | Supplying & Fixing of 100 Amp 4 Pole MCCB, 10 KA breaking capacity with spreader terminals in the existing LT Panel i/c connection from busbar and operating handle etc complete as reqd. [M/s L&T DY125U make] |
| 47 | Supplying & fixing of following way steel enclouser dust protected ,duly powder painted on surface or in recess complete with connection, testing and commissioning etc complete as required (M/s Legrand /Havells /HPL / L&T Make) (a) 4 way steel enclouser |
| 48 | Supplying & Fixing of Powder coated Free Cooling unit made out of 18 gauge M.S Sheet box with locking door in front & Jali in back side i/c Supplying & Fixing 300 mm sweep Heavy Duty Exhaust Fan 1400 rpm suitable for 230V 50 HZ AC supply i/c making opening in brick wall / window for fixing of unit, connection, testing etc. complete as reqd. (Exhaust fan Make - Crompton / Havells / Bajaj or SS make) (a) Out door unit (For Exhaust of Hot Air) |
| 49 | Supplying & Fixing of Timer unit constituting of 01 No. Digital type thermostat / Temp Controller with LED display & sensor with lead and 01 No. Analog Time Switch / Electronic timer (1 second to 10 hrs.) in suitable size MS box with hinged door, connection etc. as required. (Timer make BCH/L&T/GIC-J648B1 & Analog Time Switch make- SELEC-TC513/TC533BX or Similar superior make) Note: Time will run Exhaust fan for 2 hrs and keep in off position for 15 minutes. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender