Housing Urban and Rular Development Government Departments Closing in 14 days TDR #56431018

Tender For Work Of Installation Of Air Conditioning Plants In All The Court Rooms And Rest Rooms Of The District Judge And All The Additional District Judges (Except The 42 Court Rooms And Rest Rooms Already Established) In The District Court, Lucknow.

Issued by Government Departments · Lucknow, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Jul 2026
14 days left
EMD
8 Lakhs
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Work Of Installation Of Air Conditioning Plants In All The Court Rooms And Rest Rooms Of The District Judge And All The Additional District Judges (Except The 42 Court Rooms And Rest Rooms Already Established) In The District Court, Lucknow.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 14-Jul-2026 BOQ Corrigendum Letter Other 30-Jul-2026

BOQ

Name of Work:- tuin U;k;ky;] y[kuÅ esa tuin U;k;k/khk egksn; ,oa leLr vij tuin U;k;k/khkksa ds leLr U;k;ky; d{kksa ,oa foJke d{kksa ¼iwoZ esa LFkkfir 42 U;k;ky;ksa d{kksa ,oa foJke d{kksa dks NksM+dj½ esa okrkuqdwyu la;=ksa dh LFkkiuk dk dk;ZA
Sl. No. Item Description
1PART-ASupplying, Installation, Testing and Commissioning of 2 ton capacity Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface/concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) , i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll/rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply: Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 °C (out door ambient temperature).
2Supplying, Installation, Testing and Commissioning of 1.5 ton capacity Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface/concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) , i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll/rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply: Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 °C (out door ambient temperature).
3SITC of suction/discharge pipe line in split A.C unit upto 2.0 ton capacity including brazing,nitrile,rubber insulation 6 mm thick class\\"O\\" etc.complete 3/8\\"(9.50 mm) and 5/8\\" (15.90mm)
4SITC of suction/discharge pipe line in split A.C unit upto 1.5 ton capacity including brazing,nitrile,rubber insulation 6 mm thick class\\"O\\" etc.complete 1/2\\"(12.70 mm) and 1/4\\" (6.40mm)
5Supply of wall mounted copper wounded Voltage stablizer 5 KVA Capacity
6Supply of wall mounted copper wounded Voltage stablizer 4 KVA Capacity
7Supply and laying of heavy duty PVC plastic braided 32mm OD flexible pipe for condensed water with dipping accessories complete
8S/F of Inter connecting Electrical cable for A.C (2.5 Sq. mm 3 core) for Indoor to Stablizer connection
9S/F of Inter connecting Electrical cable for A.C (2.5 Sq. mm 4 core) for Indoor to outdoor connection
10Fabrication of M.S stand for Outer unit of A.C withfixing on wall with all material & labour complete in all respect
11Supply & Fixing of Outdoor Cage for 1 ton/1.5/2 Ton A/C
12Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required for A.C.
13Modular type MCB protected socket with sheet steel enclosure for A.C. unit
14Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
154 way (4 + 12), Double door
16Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
174 way (4 + 12), Double door
18Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
19Single Pole
20Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2163 Amp. 4 Pole MCB
22100 Amp. 4 Pole MCCB
2363 Amp. TPMCB
24Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
252 X 6 sq. mm + 1 x 4 sq. mm earth wire
264 X 10 sq. mm + 2 x 6 sq. mm earth wire
274 X 16 sq. mm + 2 x 6 sq. mm earth wire
28Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
2970 sq. mm 3-1/2 core
30400 sq. mm 3-1/2 core
31Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3270 sq. mm 3-1/2 core
33400 sq. mm 3-1/2 core
34Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. Incoming 400 Amp. MCCB-1 Nos.Outgoing 100 Amp. MCCB-3 Nos, 63 Amp MCCB-2 Nos. (1 No. for Raushandaulla Court and 1 No. for Family Court)
35Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
36Supply and fixing 25 mmX 5 mm GI strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with GI nut, bolt, spring, washer etc as required.
37Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.
38Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge.
39Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work.
40TOTAL RS.
41Less 5% As Per Deducted By P.F.A.D. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56431018
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 30-07-2026
Authority
Authority Name Public Works Department
Work Description Tender For Work Of Installation Of Air Conditioning Plants In All The Court Rooms And Rest Rooms Of The District Judge And All The Additional District Judges (Except The 42 Court Rooms And Rest Rooms Already Established) In The District Court, Lucknow.
Basic Detail
Tender No 1563/7(i)CBW-17E/M/2026-27 Dated 01-07-2026
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 14 Jul 2026
Submission Date 30 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 2354
EMD 8 Lakhs
Exemption Not Available
Document List
8be4c53d-6229-4451-a8d6-dce94215d9a4.html
BOQ_2191781.xls
T2.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 30, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 14 days
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

8be4c53d-6229-4451-a8d6-dce94215d9a4.html

xls

BOQ_2191781.xls

pdf

T2.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders