Tender For Improvement Of Water Distribution Network At Goreswar Block Id 1237 Ac Under 15Th Fc Tied Grant For The Year 2024-25 During 2025-26.
Tender Value
1 Crore
Estimated cost
Bid Submission
03 Aug 2026
16 days left
EMD
2 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baksa → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Improvement Of Water Distribution Network At Goreswar Block Id 1237 Ac Under 15Th Fc Tied Grant For The Year 2024-25 During 2025-26.
BOQ
| Sl. No. | Item Description |
| 1 | Rotary Drill/Reverse Rotary Drill : Providing installation and commissioning of 150 mm dia deep tube well by Rotary Rig within the jurisdiction of different PHE Divisions including preparation of site for placing of drilling rig, transportation of rig and ancillary equipments and drilling the DTW including extraction of drill pipes etc, lowering fitting fixing 150mm diameter UPVC pipe assembly comprising of strainer, pipes and cone in potable water bearing strata, washing the bore well etc. , supplying necessary jointing materials, developing the DTW with air compressor Make- Kirloskar / Cumins for a period of 24 hours and supplying and packing pea gravel of size 1/8\\" to 3/8\\" around the periphery of casing including screening washing etc. all complete to the satisfaction of the deptt. i) Sarania Major Suba PWSS, Harizora Village. ii) Madoikata (New) PWSS, Madoikata Village |
| 2 | Supplying, installation, testing and commissioning of Raw water submerssible pump set of different capacity at various PWSS under different divisions of the state. Supplying, installation, testing and commissioning of water lubricated Submersible Pump Set 3-Phase (for 5HP/ 7.5HP) / Single phase (for 1 HP / 2HP / 3 HP) pump with bronze impeller of suitable diameter all complete. The pump set should be coupled with wet type submersible electric motor drive of adequate power suitable for operation at 230V/ 415 V, 50 Hz input power including supply of steel cable rope, G.I. column pipe, suction strainer, Sluice Valve, Non-Return valve, sockets, bends, elbows etc. & GI delivery piping above ground up to sluice valve above ground level, electrical cable of adequate cross section, clips electrical switch gear (starter) etc., Electric Control Panel Board made of MS Sheet duly painted with Anti-corrosive paints complete fitted with all electrical accessories i.e. Off On Switch, Voltmeter, Ameter, Indicator light etc., bright Annealed Electrolytic Bar Copper Conducted PVC insulated sheathed round flexible 3-core Cable of the Motor Manufactured conforming to IS:694/1990 all complete as specified and directed by the Department with One year warranty from the date of commissioning and satisfactory testing against any manufacturing defect. [If any such defect is found during the year from the date of installation and satisfactory testing, supplier will have to rectify the defect at their cost and risk & if necessary replace the pump set. Discharge of the pump - 22.7 LPM Design Head - 56 M Recommended make:- Crompton Greaves/ Aquatic/ CRI/ GEC/ ALSTHOM/ V- Guard or equivalent i) Sarania Major Suba PWSS, Harizora Village (3HP) |
| 3 | Madoikata (New) PWSS, Madoikata Village (3HP) |
| 4 | Supplying, laying , fitting & fixing GI (Medium Class) Pipe conforming to IS-1239 (pt-I) 2004 (Ammended 2010) including GI specials and jointing material, cutting of pipe materials and necessary earthwork in trenching and refilling of earth and restore to its original condition including dressing, dewatering incuding bailing out water where necessary all complete and also necessary testings and commissioning as per direction of the department. i)Sarania Major Suba PWSS, Harizora Village (50mm dia) (RWPM) |
| 5 | Madoikata (New) PWSS, Madoikata Village (65mm dia pipe) (RWPM) |
| 6 | Supplying, laying , fitting & fixing GI (Medium Class) Pipe conforming to IS-1239 (pt-I) 2004 (Ammended 2010) including GI specials and jointing material, cutting of pipe materials and necessary earthwork in trenching and refilling of earth and restore to its original condition including dressing, dewatering incuding bailing out water where necessary all complete and also necessary testings and commissioning as per direction of the department. i) Sarania Major Suba PWSS, Harizora Village (80mm dia) (CWPM) |
| 7 | Madoikata (New) PWSS, Madoikata Village (65mm dia pipe) (CWPM) |
| 8 | Construction of ESR of different capacities for different SBC of soil with RCC Staging(M25 Grade of concrete) of 16 m height and RCC water tank(M30 grade of concrete) as per approved drawings and specification including earthwork in excavation for foundation trenches of walls, footing including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth,construction of RCC foundation(Shallow foundation or pile foundation), 15mm plastering in proportion 1:4 in RCC support pillars with water container, painting , fitting and fixing of thredded GI inlet, outlet, overflow pipes,wash pipes,vent pipe,sluice valve, aviation lamp, RCC ladder, all formworks, shuttering & Scaffolding, including materials and labour all complete in the jurisdiction of different division of PHE, Assam for the following capacities of water tank as per approved design & drawings.(Drawings will be supplied bythe Department). i) Madoikata (New) PWSS, Madoikata Village (30,000Litres Capacity ESR 8ton/Sq.m) |
| 9 | Collection from the field and testing in the laboratory of undisturbed soil samples for sub- soil investigation (as per relevant I.S code) by open drive sampler (100mm dia boring) through clayey soil layer/ sandy soil layer/ sandy clay/ sandy silt layer/ clayey silt layer, conduction standard penetration test (SPT) and collection of SPT sampler, observation of ground water table, spot level survey to the bore location and carrying out R.L. from nearest B.M., laboratory test (particle size analysis, hydrometer test, determination of liquid limit, plastic limit, bulk density, moisture content, specific gravity,conducting triaxal test, direct shear test, unconfined compression test, consolidation test including preparation of sub- soil investigation report complete with necessary printing and binding (minimum 5 copies) ii) Madoikata (New) PWSS, Madoikata Village |
| 10 | Supplying, installation, testing and commissioning of Centrifugal pump set of different capacity at various PWSS under different divisions of the state Supplying, installation, fitting & fixing, testing and commissioning of Electric driven 3-phase (for 5HP/ 7.5HP/10HP/12.5HP) / Single phase (for 1 HP / 2HP/ 3 HP pump) Centrifugal pump set of approved make with bronze impeller of suitable diameter with G.I. suction pipe, suction strainer, non-return valve, delivery piping up to sluice valve all complete. The pump set should be coupled with electric motor drive of adequate power suitable for operation at 230V / 415 V, 50 Hz input power with DOL Starter /Star delta Starter including Electric Control panel board enclosure made of MS Sheet duly painted with Anti- corrosive paints complete, fitted with all electrical accessories. i.e. Off-On Switch, Voltmeter, Ammeter, Indicator light etc., Complete wiring from Panel Board to Main Line including supply of Aluminium Armoured Cable of adequate cross section, Earthing wire and all necessary materials for the same, including cost of CC pump foundation with base plate complete and other accessories and labour charge for installation of the pump etc. all complete as specified and directed by the Department with One year warranty from the date of commissioning and satisfactory testing against any manufacturing defect. [If any such defect is found during the year from the date of installation and satisfactory testing, supplier will have to rectify the defect at their cost and risk & if necessary replace the pump set.] Test Certificate of Pump, Motor, Starter, Panel Board, etc. from the manufacturer shall have to be submitted:Clear Water Pump. Discharge of the pump - 22.7 LPM. Design Head - 17 M, Recommended make:- Crompton Greaves/ Aquatic/ CRI/ GEC/ ALSTHOM/ V- Guard or equivalent. HP of pump (to be provided) Single Phase / 3-Phase. i) Sarania Major Suba PWSS, Harizora Village (5HP). |
| 11 | Madoikata (New) PWSS, Madoikata Village (3HP). |
| 12 | Supply, installation, testing and comissioning of electrically operated chemical dosing pump of 6 L capacity and 6 kg/cm2 complete with PVC solution mixing container and electrical wiring with panel board fitting and fixing at site with suction and discharge tubings.Standard Materials for construction1. Housing :- Fiber reinforced plastic2. Spacer & Head :- Poly propylene/UPVC3. Diapharm :- Tefflon Faced Hupalon4. Ball :- PTFE5. Suction & discharge ball cartidge :- Poly propylene/UPV6. Suction & Discharge Tubings :- HDPE/LDPE7. MS Fabricated stand for mixing container i) Sarania Major Suba PWSS, Harizora Village |
| 13 | Supplying, laying , fitting & fixing HDPE pipes ( High Density poly ethylene pipes pE 100 ) conforming to IS 4984/2016 (with up to date amendament) with necessary jointing material like mechanical connector of jointing pipes by heating the ends of pipes with help of teflon coated electric mirror / heater to the required temperature and then pressing the ends together against each other to form a monolitic and leak proof joint by thermosetting process. it may be required to be done with jack/ hydraulic jacks/butt fusion machine . (50mm & above fusion jointed & below 50mm mechanical jointed). the HDPE fitting should be ISI marked conforming to relevant BIS code. 63mm Dia Pipe, i) Sarania Major Suba PWSS, Harizora Village. |
| 14 | Madoikata (New) PWSS, Madoikata Village |
| 15 | 75mm dia. Sarania Major Suba PWSS, Harizora Village |
| 16 | Madoikata (New) PWSS, Madoikata Village |
| 17 | 90mm dia. Sarania Major Suba PWSS, Harizora Village |
| 18 | Madoikata (New) PWSS, Madoikata Village |
| 19 | 110mm dia. Sarania Major Suba PWSS, Harizora Village |
| 20 | Madoikata (New) PWSS, Madoikata Village |
| 21 | 140mm dia. Madoikata (New) PWSS, Madoikata Village. |
| 22 | Constructing of Brick masonry Sluice Valve Chamber 750mm(L) x 750mm(B) x 1250mm(H) inside, in 230mm brick work in cement mortar 1:5 (1 cement : 5 coarse sand) and precast R.C.C cover slab in prop. 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire including necessary earthwork (excavation and return filling), 75mm PCC in prop. 1:4:8 (1 cement:4 coarse sand : 8 coarse agg.) over brick flat soling and 15 mm thick inside plastering and outside plastering (upto 150mm from top) with cement mortar 1:5 (1 cement : 5 coarse sand) , complete as per standard design, including Supplying, carrying, placing in position, fitting and fixing 80mm diameter CID/F sluice valve all complete as directed. Approved good for construction drawing will be issued by the deptt. A) For 80mm dia Sluice valve against 90mm/ 75mm dia Distribution pipe line - 1 no. 80mm dia CID/F sluice valve with cap/ wheel as per IS 14846-2000 PN 1.0 with ISI marking, 2 nos. 80mm dia GI Nipple (225mm long), 4 Nos. 80mm dia GI Threaded Flange, 2 Nos. 90mm dia UPVC Flange, 26 Nos. Bolts & nuts and 6 nos. 3mm thick rubber insertion sheet for 100mm dia pipe. i) Sarania Major Suba PWSS, Harizora Village (80mm dia Sluice Valve). |
| 23 | Madoikata (New) PWSS, Madoikata Village (80mm dia Sluice Valve) |
| 24 | Constructing of Brick masonry Sluice Valve Chamber 900mm(L) x 900mm(B) x 1250mm(H) inside, in 230mm brick work in cement mortar 1:5 (1 cement : 5 coarse sand) and precast R.C.C cover slab in prop. 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire including necessary earthwork (excavation and return filling), 75mm PCC in prop. 1:4:8 (1 cement:4 coarse sand : 8 coarse agg.) over brick flat soling and 15 mm thick inside plastering and outside plastering (upto 150mm from top) with cement mortar 1:5 (1 cement : 5 coarse sand) , complete as per standard design, including Supplying, carrying, placing in position, fitting and fixing 100mm/ 125mm/ 150mm diameter CID/F sluice valve all complete as directed. Approved good for construction drawing will be issued by the deptt. A) For 100mm dia Sluice valve against 110mm dia Distribution pipe line - 1 no. 100mm dia CID/F sluice valve with cap/ wheel as per IS 14846-2000 PN 1.0 with ISI marking, 2 nos. 100mm dia GI Nipple (225mm long), 4 Nos. 100mm dia GI Threaded Flange, 2 Nos. 110mm dia UPVC Flange, 28 Nos. Bolts & nuts and 6 nos. 3mm thick rubber insertion sheet for 100mm dia pipe. i) Sarania Major Suba PWSS, Harizora Village (100mm dia Sluice Valve) |
| 25 | Madoikata (New) PWSS, Madoikata Village (100mm dia Sluice Valve) |
| 26 | Construction of Functional Household Tap Connection including earthwork in excavation for pipe line (both for connection in distribution line and service connection) and refilling, dressing etc., providing PVC Saddle Piece of average size 110 mm x 15 mm (i.e. ranging from 63mm to 140mm) and make Supreme or equivalent, making holes in the distribution pipe, providing 15 mm dia bronze ferrule cock (PN-16) conforming to IS:2692 (1989) as ammended and make Zoloto or equivalent, connecting it to the saddle piece, providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP- R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 of length 10m from saddle piece to the tap point ( pipes of make SFMC/ FUSION/Wetflow, Kisan brand or other brand of equivalent quality and PN-16 Pipe,20 mm OD,SDR-7.4) including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages, including all taxes and duties as applicable and including the cost of all required labour and materials as directed and specified. The item also includes construction and installation of R.C.C Hydrant Pillar of size 100mm x 100 mm , height 1200 mm with 6 mm dia bar embeded to RCC Post in proportion 1:1.5:3 with 4 nos 10 mm dia main and 6 mm dia stirrup @ 150 C/c and fixing 15 mm dia PPR pipe to the hydrant, with 6 mm rings embedded in concrete for anchoring inclusive of cost of transportation to site and also supplying fitting and fixing PVC Bib cock all complete as directed and specified. Approved good for construction drawing will be issued by the deptt. i) Sarania Major Suba PWSS, Harizora Village ii) Madoikata (New) PWSS, Madoikata Village |
| 27 | External & Internal Electrification to Raw & Clear water pump house including wiring for light/fan/call bell point with 2x1.5 sq mm PVC insulated single core unshearthed industrial cable FB confiriming to Is-694 : 1990 with flexible bright annelead eletrolytic copper conducter for voltage grade up to 1100 volts(finolex/RR kabel/ Nicco/ Anchor or Equivalent make as approved by deptt) providing and fixin ICSP and N link main switch of 240 volts grade including drilling boards/ iron frames and fixing with bolts and nuts and connection as approved by the dept. complete as required , providing and fixing LC distribution fuse boards with rewire able fuses 250 volt grade, supplying fixing of 18/20 - 5/9 watt CFL lamp in the existing batten holder/angle holder/decorative /bulk head fitting / pendent holder etc as specified and directed by the deptt. i)Sarania Major Suba PWSS, Harizora Village. ii) Madoikata (New) PWSS, Madoikata Village. |
| 28 | Construction of gravity type Rapid Sand Filter of Size 4m2/6m2 including the following item of works:(i) Earthwork for excavation(ii) 150 mm thick PCC (prop. 1:3:6)(iii) Brick soling(iv) Formwork of ordinary timber planking including centering, shuttering, propping, etc.(v) PCC/RCC works (M25 grade in foundation & superstructure)(v) 250 mm brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. (vi) 15 mm thick Cement plaster in single coat on rough and fair side (prop. 1:4)(vii) Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make (two coats)(viii) Supplying, fitting and fixing including labour charge of under drainage with 150 mm dia PVC manifold and 63 mm dia PVC laterals and interconnection of the filter unit including necessary GI fittings.(ix) supplying and charging of filter media considering all materials for the filter bed constructed as per the specification provided by the deptt. The specification of the sand and gravel is as below:(a) Sand should be hard, resistant quartz, free from clay, fine particles, soft grains, organic matter and dirt. Effective size of sand (d10) has to be within the range from 0.45 mm to 0.7 mm and uniformity coefficient (d60/d10) within 1.3 to 1.7. The effective depth of sand bed has to be 0.60 m.(b) Gravel has to be hard preferably rounded stone and not crushed stone, with average specific gravity not less than 2.5 and shall be free from clay, loam and organic impuritues. Size range has to be from 2mm to 65mm properly graded as directed by the deptt. The effective depth of gravel bed has to be 0.50 m. |
| 29 | Supplying, fitting, fixing of internal connection between TP & UGR including labour charge and materials which includes the following jobs:a. Earth work in excavation in foundation trenches (of size 1 x 1 x 18.00 m x 0.60m x 0.90m=9.72 Cu.M) including refilling the quantity as necessary after completion of works of pipe line dressing, ramming, watering etc as directed by the Deptt.b. Supplying of UPVC perforated laterals of 50mm dia and 60 cm long by making hole of 5mm dia at a spacing of 8 cm centre to centre in two lines at 60 degree with the centre of the pipe and threading at both ends and supplying, fitting and fixing 40mm dia U.P.V.C. threaded End Plug at one end, the other end to be fitted with a UPVC threaded nipple of 75 mm long properly embedded in RCC cover slab all complete. Providing precast R.C.C slab over drain,septic tank etc. in prop. 1:3/2:3 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete i) Madoikata (New) PWSS, Madoikata Village (4 Sq.m Filter bed) |
| 30 | Construction of RCC Under Ground Reservoir of various capacities by excavating necessary earthwork, including dewatering, stabilising side earth, preparation of sub soil etc. with 100 mm thick PCC (in prop. 1:3:6), using M25 grade of concrete including dewatering if necessary, and curing; application of air entraining and water reducing plasticiser (masterplast PAE ) conforming to IS 9103-1999 @ 0.15 Lit per bag of cement (or equivalent); and 15mm thick plastering and painting, along with inlet channel, vent pipe and other pipe connections, form work, shuttering and shoring etc. for storage of treated drinking water as per approved drawings and specification, along with 450 mm inlet channel with hydraulic jump for mixing of fluid and fitting and fixing of 100mm dia GI outlet, vent pipes as per approved drawings and specification as per approved good for construction drawing issued by the deptt. (UGR to be tested for leak proof). i) Madoikata (New) PWSS, Madoikata Village (30,000 Litres 8ton/Sq.m). |
| 31 | Construction of Pump House of following size including necessary earthwork, 100 mm thick PCC (in prop. 1:3:6) over flat brick soling for foundation, 12 mm dia main reinforcement for columns, providing, fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. circular hollow section, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats, providing PPGL sheets and accessories (Ridges / Valley / Gutter / Flashing) including fitting and fixing sheets for ceiling. Providing and laying plain/reinforced CC work including dewatering and curing including 1st class brick work of 112 mm thickness and providing wood work in frame (Chowkat) of door, window and other similar works as directed with 1st Class timber along with fitting and fixing battend ledged and braced door including painting and priming 2 coats on the wooden surface. Providind and laying 65mm thick Cement Concrete flooring underlayer of 50mm (1:3:6 prop.) and 15mm thick cement plastering in cement mortar 1:4 all complete as per approved good for construction drawing issued by the deptt. i) Madoikata (New) PWSS, Madoikata Village. |
| 32 | Supplying, fitting and fixing chain link fencing of 10 S.W.G, G.I. Wire 50mm x50mm mesh fitted to M.S angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I wire 10 S.W.G at top,middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following.a) Corner and end posts with M.S angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts.b) Intermediate post with M.S angle of size 40mmx40mmx5mm and length not less than 1800mm only duly slotted and bottom torqued and splayed.c) Stay post with M.S angle of size 35 mmx35mmx5mm and length not less than 1800mm duly slotted and bottom torqued and splayed. AllM.S angle iron posts are to be fitted to P.C.C base embedded not less than 600mmd) Intermediate post with M.S angle of size 40mmx40mmx5mm and length not less than 1800mm only duly slotted and bottom torqued and splayed.e) Stay post with M.S angle of size 35 mmx35mmx5mm and length not less than 1800mm duly slotted and bottom torqued and splayed. AllM.S angle iron posts are to be fitted to P.C.C base embedded not less than 600mm. i) Madoikata (New) PWSS, Madoikata Village. |
| 33 | ii) Sarania Major Suba PWSS, Harizora Village |
| 34 | Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts). i) Madoikata (New) PWSS, Madoikata Village. |
| 35 | Labour charge for making bore hole horizontally across road or embankment for crossing distribution pipe line including fitting fixing of GI cassing pipe of required dia including the cost of pipe all complete as directed by the deptt. i) 80 mm boring for 65 mm dia pipe at Madoikata (New) PWSS, Madoikata Village |
| 36 | ii) 100 mm boring for 80 mm dia pipe at Madoikata (New) PWSS, Madoikata Village. |
| 37 | Making sign board of size 3 m (W) x 1.2 m (H) with 50 mm MS square pipe supporting postin a frame of 32 mm MS square boundary pipes with 3 nos 25mm MS square strut pipe welded with a 3 mm thick MS plain sheet (3 m x 1.2 m) including foundation work , all complete and as directed by the Engineer-in-charge. i) Sarania Major Suba PWSS, Harizora Village. ii) Madoikata (New) PWSS, Madoikata Village |
| 38 | Supplying fitting & fixing of Bulk Flow Meter conforming to ISO: 4064/1Providing, installation, testing and commissioning of Bulk Flow Meter with removable mechanism class \\"B\\" confirming to ISO: 4064/1 including all materials (excluding CI/DI fittings) and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipe line etc complete in all respect as per technical specification and as perdirection of Engineer. i) Sarania Major Suba PWSS, Harizora Village |
| 39 | Repairing of Underground Reservoir i) Sarania Major Suba PWSS, Harizora Village. |
| 40 | Repairing of Treatment Plant i) Sarania Major Suba PWSS, Harizora Village |
| 41 | Repairing of Pump House i) Sarania Major Suba PWSS, Harizora Village. |
| 42 | Cost of External Electrification to Piped water Supply Scheme. i) Sarania Major Suba PWSS, Harizora Village. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender