Tender For Tender For Balance Civil , Plumbing , Electrical, Hvac & Ict Works Except Structural Glazing At Various Location For Construction Of Auditorium & Convention Hall Building At Rourkelaone Project At Abd Area In Rourkela
Tender Overview
Project Description
Tender for Tender For Balance Civil , Plumbing , Electrical, Hvac & Ict Works Except Structural Glazing At Various Location For Construction Of Auditorium & Convention Hall Building At Rourkelaone Project At Abd Area In Rourkela
BOQ
| Sl. No. | Item Description |
| 1 | Tender for Balance Civil , Plumbing , Electrical, HVAC & ICT works except Structural Glazing at various location for construction of Auditorium & Convention hall Building at RourkelaOne Project at ABD Area in Rourkela Tender for Balance Civil , Plumbing , Electrical, HVAC & ICT works except Structural Glazing at various location for construction of Auditorium & Convention hall Building at RourkelaOne Project at ABD Area in Rourkela NIT No: EPI/PCO/BBSR/806/259 dated 11.07.2026 Sl. No. Description of Works Amount in Rs. |
| 2 | Civil Work |
| 3 | Sanitary and Plumbing Works |
| 4 | Electrical WORKS |
| 5 | Firefighting Work |
| 6 | PA System |
| 7 | CCTV, LAN & Telephone |
| 8 | UPS Total 134473848.07 Say 134473848.0 Rupees: Thirteen Crore Forty Four Lakh Seventy Three Thousand Eight Hundred & Forty Eight Only Tender for Balance Civil , Plumbing , Electrical, HVAC & ICT works except Structural Glazing at various location for construction of Auditorium & Convention hall Building at RourkelaOne Project at ABD Area in Rourkela NIT No: EPI/PCO/BBSR/806/806 dated 11.07.2026 Sl.No. Ref. No. Description of Items Unit Quantity Rate (in Rs) Amount CIVIL WORK |
| 9 | 6.45.1 |
| 10 | 6.32.2 |
| 11 | 13.4.1 |
| 12 | 13.6.1 |
| 13 | 4.1.2 |
| 14 | 5.9.5 |
| 15 | 5.9.6 |
| 16 | 5.22A.6 |
| 17 | 5.33.1.2 |
| 18 | 12.47.2 |
| 19 | 8.2.2.1 |
| 20 | 11.56.1 |
| 21 | Analyse rate from 11.56.1 |
| 22 | 12.45 |
| 23 | 12.45.4 |
| 24 | 12.53 |
| 25 | 12.54.1 |
| 26 | 22.25.1 |
| 27 | 13.41(DSR-2021) |
| 28 | 13.46.1 |
| 29 | 21.18+ 30% for all fittings |
| 30 | 26.86.6 |
| 31 | 26.87.1 |
| 32 | 9.20.1 |
| 33 | 10.6.2 |
| 34 | Item No. 8778+20% for fixing |
| 35 | 16.71 |
| 36 | 19.4.2.1 |
| 37 | 14.23 |
| 38 | MR 16 mm dia Bar in vertical retaining wall / Raft /Columns /slab Nos 6.0 792.0 4752.0 20 mm dia Bar in vertical retaining wall / Raft /Columns /slab Nos 10.0 880.0 8800.0 25 mm dia Bar in vertical retaining wall / Raft /Columns /slab Nos 10.0 968.0 9680.0 TOTAL 50098764.04 SANITARY & PLUMBING WORK |
| 39 | MR 3912408.76 ELECTRICAL WORK A WIRING |
| 40 | (i) DSR_2025_1.17.3 3 x 1.5 sq. mm Mtr 11500.0 88.13 1013495.0 (ii) DSR_2025_1.17.12 3 x 2.5 sq. mm Mtr 8500.0 125.42 1066070.0 (iii) DSR_2025_1.17.21 3 x 4 sq. mm Mtr 2500.0 188.13 470325.0 (iv) DSR_2025_1.17.31 4 X 6 sq. mm Mtr 200.0 365.25 73050.0 (v) NDSR 4 X 10 sq. mm Mtr 100.0 956.2 95620.0 (vi) NDSR 4X 16 sq. mm Mtr 80.0 1486.46 118916.8 |
| 41 | (i) DSR_2025_1.21.1 20 mm Mtr 800.0 127.96 102368.0 (ii) DSR_2025_1.21.2 25 mm Mtr 500.0 129.46 64730.0 (iii) DSR_2025_1.21.3 32 mm Mtr 250.0 164.28 41070.0 |
| 42 | (i) DSR_2025_1.20.1 20 mm Mtr 100.0 215.25 21525.0 (ii) DSR_2025_1.20.2 25 mm Mtr 50.0 244.91 12245.5 |
| 43 | DSR_2025_1.33 |
| 44 | (i) NDSR 100 x 50 mm Mtr 40.0 1028.0 41120.0 |
| 45 | (i) DSR_2025_ 1.24.1 5/6 A switch Nos 1348.0 102.54 138223.92 (ii) DSR_2025_1.24.3 15/16 A switch Nos 420.0 149.15 62643.0 (iii) DSR_2025_1.24.4 3 pin 5/6 A socket outlet Nos 695.0 115.25 80098.75 (iv) DSR_2025_1.24.5 6 pin 15/16 A socket outlet Nos 420.0 185.59 77947.8 |
| 46 | (i) DSR_2025_1.28.1 1 or 2 Module Nos 456.0 132.2 60283.2 (ii) DSR_2025_1.28.2 3 Module Nos 412.0 148.3 61099.6 (iii) DSR_2025_1.28.3 4 Module Nos 47.0 154.23 7248.81 (iv) DSR_2025_1.28.4 6 Module Nos 312.0 175.42 54731.04 (v) DSR_2025_1.28.5 8 Module Nos 156.0 201.69 31463.64 (vi) DSR_2025_1.28.7 TV antenna socket outlet Nos 15.0 142.37 2135.55 (vii) DSR_2025_1.26 Modular blanking plate Nos 100.0 39.83 3983.0 3713613.11 B DB, MCBS, RCCBs Etc. |
| 47 | (i) DSR_2025_2.10.1 Single pole Nos 850.0 241.52 205292.0 (ii) DSR_2025_2.10.5 Triple pole and neutral Nos 12.0 1102.54 13230.48 Supplying and fixing following rating, four pole, 415 V,isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (i) DSR_2025_2.13.1 40 A Nos 8.0 888.98 7111.84 (ii) DSR_2025_2.13.2 63 A Nos 8.0 944.91 7559.28 (iii) DSR_2025_2.13.3 100 A Nos 1.0 1116.1 1116.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (v) DSR_2025_2.14.1 25 A Nos 1.0 1814.4 1814.4 (vi) DSR_2025_2.14.2 40 A Nos 21.0 2128.81 44705.01 (vii) DSR_2025_2.14.3 63 A Nos 21.0 2428.81 51005.01 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (viii) DSR_2025_2.15.1 25 A rating, 4 pole RCCB, 30 mA Nos 12.0 2658.47 31901.64 363735.76 C CABLE TRAY,CABLING AND END TERMINATION etc. |
| 48 | (i) DSR_2025_4.6.1 100 mm width X 60 mm depth X1.6 mm thickness Mtr 50.0 638.98 31949.0 (ii) DSR_2025_4.6.2 150 mm width X 50 mm depth X 1.6 mm thickness Mtr 80.0 680.51 54440.8 (iii) DSR_2025_4.6.3 225 mm width X 50 mm depth X 1.6 mm thickness Mtr 100.0 839.83 83983.0 (iv) DSR_2025_4.6.4 300 mm width X 60 mm depth X 1.6 mm thickness Mtr 150.0 900.0 135000.0 |
| 49 | (i) NDSR 300 mm width X 75 mm depth X 1.6 mm thickness Mtr 30.0 739.06 22171.8 (ii) NDSR 600 mm width X 75 mm depth X 2 mm thickness Mtr 30.0 942.06 28261.8 (iii) NDSR 750 mm width X 75 mm depth X 2 mm thickness Mtr 40.0 1126.63 45065.3333333333 |
| 50 | (i) NDSR 4C x 10 Sqmm. Mtr 925.0 293.99 271940.75 (ii) NDSR 4C x 16 Sqmm. Mtr 250.0 318.68 79670.0 (iii) NDSR 3.5C x 25 Sqmm. Mtr 200.0 351.22 70244.0 (iv) NDSR 3.5C x 35 Sqmm. Mtr 150.0 453.89 68083.5 (v) NDSR 3.5C x 50 Sqmm. Mtr 235.0 604.82 142132.7 (vi) NDSR 3.5C x 95 Sqmm. Mtr 150.0 1043.56 156534.0 (vii) NDSR 3.5C x 240 Sqmm. Mtr 315.0 2460.79 775148.85 |
| 51 | (i) DSR_2025_10.8.1 Upto 35 sq.mm Mtr 1375.0 44.91 61751.25 (ii) DSR_2025_10.8.2 Above 35 sq.mm and upto 95 sq. mm Mtr 535.0 92.37 49417.95 (iii) DSR_2025_10.8.3 Above 185 sq.mm and upto 400 sq. mm Mtr 315.0 116.95 36839.25 |
| 52 | (i) NDSR 4C x 10 Sqmm. Nos 26.0 236.0 6136.0 (ii) NDSR 4C x 16 Sqmm. Nos 10.0 271.0 2710.0 (iii) NDSR 3.5C x 25 Sqmm. Nos 4.0 850.0 3400.0 (iv) NDSR 3.5C x 35 Sqmm. Nos 10.0 850.0 8500.0 (v) NDSR 3.5C x 50 Sqmm. Nos 12.0 950.0 11400.0 (vi) NDSR 3.5C x 240 Sqmm. Nos 46.0 1750.0 80500.0 |
| 53 | (i) NDSR 2C x 2.5 Sqmm Mtr 50.0 191.88 9594.0 (ii) NDSR 4C x 2.5 Sqmm Mtr 50.0 328.22 16411.0 (iii) NDSR 6C x 2.5 Sqmm (Shielded Cable) Mtr 40.0 476.9 19076.0 (iv) NDSR 24C x 2.5 Sqmm (Shielded Cable) Mtr 40.0 1766.2 70648.0 2341008.98 D EARTHING INSTALLATION |
| 54 | DSR_2025_5.15 |
| 55 | DSR_2025_5.9 |
| 56 | DSR_2025_5.8 |
| 57 | DSR_2025_5.14 |
| 58 | DSR_2025_5.6 |
| 59 | DSR_2025_5.4 |
| 60 | DSR_2025_5.2 532670.76 E LIGHT FITTING FIXTURES |
| 61 | NDSR NDSR Supplying,Fixing, Testing and commissioning of wipro make , CAT No. WCS-IS-DA32 (Dimming controls for Auditorium) as per direction of Engg.-in-Charge. including connection etc. as required. Nos 8.0 28794.0 230352.0 |
| 62 | NDSR 4563963.0 |
| 63 | DSR_2025_7.1 124470.0 F 33kV Ring Main Unit & 800kVA Compact Substation. |
| 64 | (i) Supply, Erection, Testing and Commissioning of 1600 Amps Straight Length Busudct, 50kA for 1 Sec (IP-55, Indoor) with necessary support arrengements. Mtr. 12.0 35097.0 421164.0 (ii) Supply, Erection, Testing and Commissioning of 1600 Amps Straight Length Busudct, 50kA for 1 Sec (IP-65, Outdoor) with canopy including outdoor structure, foundation etc as required to complete the job. Mtr. 20.0 37453.0 749060.0 (iii) 1600 Amps Horizontal/Vertical Elbow (Fabrication cost Only) (Indoor/Outdoor) Nos. 12.0 17050.0 204600.0 (iv) 1600 Amps Flange End with Adopter Box (Fabrication Cost Only) Nos. 6.0 34870.0 209220.0 (v) Supply, Erection, Testing and Commissioning of 1600 Amps Copper Flexible. Set 6.0 49111.0 294666.0 (vi) 1600 Amps Phase Transposition Unit (Fabrication cost Only) Nos. 2.0 25630.0 51260.0 17095645.0 1010kVA DG Set. |
| 65 | (i) NDSR 250 mm (NB) dia Exhaust Pipe Rm 10.0 4651.0 46510.0 (ii) NDSR 350 mm (NB) dia Exhaust Pipe Rm 18.0 7069.0 127242.0 |
| 66 | (i) NDSR 250 mm (NB) dia Exhaust Pipe Rm 10.0 2175.0 21750.0 (ii) NDSR 350 mm (NB) dia Exhaust Pipe Rm 18.0 3045.0 54810.0 |
| 67 | NDSR NDSR Supply and installation of SS Flexible Bellows, 10\\" dia. (250 mm NB), complete with counter flanges, heat resitant gaskets, nuts-bolts-washers etc., complete as required. Nos 2.0 18400.0 36800.0 |
| 68 | (i) NDSR 2C x 2.5 Sqmm Mtr 100.0 191.88 19188.0 (ii) NDSR 4C x 2.5 Sqmm Mtr 100.0 328.22 32822.0 (iii) NDSR 6C x 2.5 Sqmm (Shielded Cable) Mtr 50.0 476.9 23845.0 (iv) NDSR 24C x 2.5 Sqmm (Shielded Cable) Mtr 50.0 1766.2 88310.0 10141814.0 |
| 69 | NDSR 501816.6 G LT Panels Supply, delivery, installation, testing & commissioning of L.T. indoor floor mounted type panels compartment 4B,3B, IP-42/IP-54 made out of 2mm thick CRCA sheet, gland plate-3 mm metal cubicle fixed on m.s. channel base ISMC75, painting with NINE TANK process i.e degreasing, Water Rinsing-I, Derusting-I, Derusting-II, Water Rinsing-II, Activation, Phosphating, Water Rinsing-III and Passivation. Panel shall be with Texture finish electro static paint (Powder Coating) paint thickness more than 80 micron(RAL-7035) having hinged door and compartmental arrangement for each equipment & Busbar shall be of electrolytic grade AL and supported on NON-hygroscopic , Non carbonising, corrosion resistance SMC/DMC insulators. having provision for Top/Bottom cable/ conduit entry, SPD,MPCB in all incomer, MFM,CT, PT, control wiring with 2.5sqmm earthing studs as per TTA guideline/specification mentioned conforming to the relevant IS and as per special conditions, as per approved SLD/drawing/technical specification complete as direction of Engineer-in-charge.Make- L&T In the panel All ACB & MCCB(above 250A) OF Microprocesser based should be available with Communication with All accessories required for communications.MCCBs from 250A and above shall be of Microprocesser based double break having LSING Protections with Communication accessoriesSystem and below 250A havingThermal Magnetic Release with adjustable O/L(0.8-1In) & S/C Protection(6-10In) (Icu=Ics=100%Icw) with axulary for BMS.(D-shine) |
| 70 | NDSR In commer-1 01 number of 4P 2000/1600A EDO ACB Icu=Ics=Icw=50kA for 1 Sec having power metering & LCD display communication port, Microprocesser Based, O/S, S/C & E/F release with necessary accessories,MFM,Ammeter,Voltmeter,CT,PT,Relays,CT for APFC, Communication System & Auto Electrical locking for normal & DG power supply as per the approved drawing and technical specification. Provision for 1600A sandwich bus duct connection to be provided. In commer-2 01 number of 4P 2000/1600A EDO ACB Icu=Ics=Icw=50kA for 1 Sec having power metering & LCD display communication port, Microprocesser Based, O/S, S/C & E/F release with necessary accessories,MFM,Ammeter,Voltmeter,CT,PT,Relays,Communication System, battery charger for DG & Auto Electrical locking for normal & DG power supply as per the approved drawing and technical specification.Provision for 1600A sandwich bus duct connection to be provided. In commer-3 01 number of 4P 400A MCCB Icu=Ics=Icw=50kA for 1 Sec having provision for fixing of Direct Type Meter, Microprocesser Based, O/S, S/C & E/F release with necessary accessoriesMPCB, SPD, Ammeter, Voltmeter, CT,PT,Communication System, etc suitable for solar power incomer as per the approved drawing and technical specification. Busbar-1&2- 04 numbers of 2x100x10 Aluminium busbar with 1x50x06 AL Earth bus color coated PVC sleeve & supported by suitable size SMC/DMC insulator. Out going- (i) 02 numbers of 1250A TP+N MDO Type ACB , 01 numbers of 800A TP+N MDP Type ACB 50kA Microprocesser Based having O/S, S/C & E/F release with all accessories. MPCB, CT, MFM etc as per approved drawing, as per requirment. Out going- (ii) 02 numbers of 250A , 03 numbers of 200A, 02 numbers of 160A, 01 numbers 100A, 01 number 80A, 05 numbers 63A, 01 number 40A 4P MCCB Ics=100%Icu 50kA Thermal Magnetic Based having O/S, S/C release (Double Break) with all accessories. As per approved drawing.(D-shine) Instrument- Digital ammeter, voltmeter, UV relay, OV relay, surge suppresser, CT, PT, PLC, MCB, SPD, MPCB,Themister, Space heater etc as per approved drawing. |
| 71 | NDSR In commer-1 - 01 number of 200A 4P MCCB Ics=50%Icu 25kA, Double Break, Thermal magnetic relesse based having o/c & s/c release with all accessories as per approved drawing. Busbar-1- 04 numbers of 1x38x6 Al busbar duly sleeved by color coated PVC sleeve with 01 number of 1x38x6 AL for earthing & supported by suitable size DMC insulator. Out going- (I) 8 numbers of 63 A TP+N 25kA MCCB and 9x40A FP MCB. Instrument- Digital MFM, Ammeter, MPCB, Voltmeter, CT, Indication LED, TVSS,Thermister, Space heater etc as per approved drawing. |
| 72 | NDSR In commer-1 - 01 number of 160A 4P MCCB Ics=50%Icu 25kA, Double Break, Thermal magnetic relesse based having o/c & s/c release with all accessories as per approved drawing. Busbar-1- 04 numbers of 1x38x6 Al busbar duly sleeved by color coated PVC sleeve with 01 number of 1x38x6 AL for earthing & supported by suitable size DMC insulator. Out going- (I) 6 numbers of 63 A TP+N 25kA MCCB and 7x40A FP MCB. Instrument- Digital MFM, Ammeter, MPCB, Voltmeter, CT, Indication LED, TVSS,Thermister, Space heater etc as per approved drawing. |
| 73 | NDSR In commer-1 - 01 number of 100A 4P MCCB Ics=50%Icu 25kA, Double Break, Thermal magnetic relesse based having o/c & s/c release with all accessories as per approved drawing. Busbar-1- 04 numbers of 1x38x6 Al busbar duly sleeved by color coated PVC sleeve with 01 number of 1x38x6 AL for earthing & supported by suitable size DMC insulator. Out going- (I) 6 numbers 40A FP MCB. Instrument- Digital MFM, Ammeter, MPCB, Voltmeter, CT, Indication LED, TVSS,Thermister, Space heater etc as per approved drawing. |
| 74 | NDSR In commer-1 - 01 number of 80A 4P MCCB Ics=50%Icu 25kA, Double Break, Thermal magnetic relesse based having o/c & s/c release with all accessories as per approved drawing. Busbar-1- 04 numbers of 1x38x6 Al busbar duly sleeved by color coated PVC sleeve with 01 number of 1x38x6 AL for earthing & supported by suitable size DMC insulator. Out going- (I) 4 numbers of 63 A TP+N 25kA MCCB.Double Break. Instrument- Digital MFM, Ammeter, MPCB, Voltmeter, CT, Indication LED, TVSS,Thermister, Space heater etc as per approved drawing. |
| 75 | NDSR In commer-1 1 No 800A ,FP EDO ACB Icu=Ics=Icw=50kA for 1 Sec having power metering & LCD display communication port, Microprocesser Based, O/S, S/C & E/F release with necessary accessories,MFM,MPCB, Ammeter,Voltmeter,CT,PT,Relays,Communication System as per the approved drawing and technical specification. 1 No.12 stage 1110V AC A.P.F.C.Relay (digital, microprocesser based) Digital MFM with RS-485 for BMS compatible, ASS, VSS, 2 no 100 kVAR capacitoe bank, 2 no 50 kVAR capacitoe bank, 2 no 25 kVAR, 1 no 10kVAR, 2 no 5 kVAR with 7% detuned reactor.(MPP Type) with necessary contactor as per approved drawing. 2 No.200A TP MCCB, 2 No.100A TP MCCB, 2No.63A TP MCCB,1 No.32A TP MCCB,1 No.25A TP MCCB(35 KA) Thermal magnetic based (Double break) MFM, Ammeter, Voltmeter, MCB, CT, PTm MPCB, necessary contacts etc as per approved drawing. |
| 76 | NDSR In commer-1 1 No 1250A ,FP EDO ACB Icu=Ics=Icw=50kA for 1 Sec having power metering & LCD display communication port, Microprocesser Based, O/S, S/C & E/F release with necessary accessories,MFM,MPCB, Ammeter,Voltmeter,CT,PT,Relays,Communication System as per the approved drawing and technical specification. Busbar-1&2- 04 numbers of 1x100x10 Aluminium busbar with 1x50x06 AL for earth bus color coated PVC sleeve & supported by suitable size SMC/DMC insulator. Out going- (i) 25 numbers of 63A , 31 numbers of 40A, TP+N MCCB 25kA Thermal Magnetic Based having O/S, S/C release with all accessories. As per approved drawing. Instrument- MPCB, Digital ammeter, voltmeter, surge suppresser, CT, PT, PLC, MCB, SPD, Themister, Space heater etc rating and class as per approved drawing. 8559066.0 H Lightning Protection System |
| 77 | NDSR 1249994.5 I Lift |
| 78 | NDSR NB:- The material/spare parts of johnson make are to be used after necessary rectification,reconditioning etc as required to complete the job without any extra cost. Three years of defect liability has to be attend without any extra cost. 1558248.0 J UPS |
| 79 | NDSR 865867.0 K SAFETY AND FIRE PROTECTION EQUIPMENTS |
| 80 | NDSR 489157.14 TOTAL 52101069.85 OUTDOOR UNIT |
| 81 | i) DSR_2025_7.1.2 12 HP Nos 1.0 204233.9 204233.9 ii) DSR_2025_7.1.2 14 HP Nos 6.0 226740.68 1360444.08 iii) DSR_2025_7.1.3 16 HP Nos 7.0 259132.2 1813925.4 iv) DSR_2025_7.1.3 20 HP Nos 6.0 323915.25 1943491.5 v) DSR_2025_7.1.3 22 HP Nos 10.0 356306.78 3563067.8 8885162.68 Air Handling Units |
| 82 | NB:- Some parts of AHU (Make- CrystalAir) are available at site, which will be issue to the party and must be utilize during execution. The available material cost will be deducted from the total payble amount under this item as per prevailing market rate. i) NDSR 7000 CFM Nos 2.0 505346.0 1010692.0 ii) NDSR 10000 CFM Nos 1.0 583250.0 583250.0 iii) NDSR 13000 CFM Nos 1.0 695006.0 695006.0 iv) NDSR 13500 CFM Nos 2.0 724551.0 1449102.0 v) NDSR 15500 CFM Nos 1.0 826758.0 826758.0 vi) NDSR 4000 CFM CHUS Nos 1.0 183829.0 183829.0 4748637.0 |
| 83 | NB:- Materials are available at site, party has to install the same and payment will be made against Instatllation, testing & commissiong. i) NDSR 0.8 TR Nos 1.0 727.0 727.0 ii) NDSR 1.0 TR Nos 3.0 909.0 2727.0 iii) NDSR 1.6 TR Nos 6.0 1286.0 7716.0 iv) NDSR 2.0 TR Nos 6.0 1295.0 7770.0 v) NDSR 2.6 TR Nos 5.0 1330.0 6650.0 vi) NDSR 3.0 TR Nos 2.0 1330.0 2660.0 vii) NDSR 3.6 TR Nos 32.0 1443.0 46176.0 viii) NDSR 4.0 TR Nos 17.0 1492.0 25364.0 99790.0 |
| 84 | NB:- Materials are available at site, party has to install the same and payment will be made against Instatllation, testing & commissiong. i) NDSR 2000 CFM Nos 2.0 3333.0 6666.0 ii) NDSR 15000 CFM Nos 4.0 6111.0 24444.0 iii) NDSR 25000 CFM Nos 2.0 8889.0 17778.0 (iv) NDSR 33500 CFM Nos 11.0 11111.0 122221.0 (v) NDSR 42000 CFM Nos 4.0 14444.0 57776.0 |
| 85 | NB:- Materials are available at site, party has to install the same and payment will be made against Instatllation, testing & commissiong. (i) NDSR 1000 CFM Nos 3.0 2047.0 6141.0 (ii) NDSR 1200 CFM Nos 1.0 2047.0 2047.0 (iii) NDSR 2000 CFM Nos 3.0 3002.0 9006.0 (iv) NDSR 2200 CFM Nos 1.0 3002.0 3002.0 (v) NDSR 2800 CFM Nos 2.0 6141.0 12282.0 (vi) NDSR 3000 CFM Nos 2.0 6141.0 12282.0 |
| 86 | NB:- Materials are available at site, party has to install the same and payment will be made against Instatllation, testing & commissiong. (i) NDSR 200 CFM Nos 2.0 1638.0 3276.0 |
| 87 | NB:- Materials are available at site, party has to install the same and payment will be made against Instatllation, testing & commissiong. i) NDSR 150 CFM Nos 8.0 1092.0 8736.0 ii) NDSR 200 CFM Nos 1.0 1092.0 1092.0 |
| 88 | NB:- Materials are available at site, party has to install the same and payment will be made against Instatllation, testing & commissiong. (i) NDSR 400 CFM Nos 2.0 1092.0 2184.0 (ii) NDSR 450 CFM Nos 4.0 1092.0 4368.0 (iii) NDSR 650 CFM Nos 2.0 1092.0 2184.0 (iv) NDSR 700 CFM Nos 1.0 1092.0 1092.0 (v) NDSR 800 CFM Nos 3.0 1365.0 4095.0 300672.0 |
| 89 | i) DSR_2025_7.14.1 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Mtr 154.0 216.95 33410.3 ii) DSR_2025_7.14.2 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Mtr 295.0 293.22 86499.9 iii) DSR_2025_7.14.3 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Mtr 285.0 412.71 117622.35 iv) DSR_2025_7.14.4 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Mtr 189.0 521.19 98504.91 v) DSR_2025_7.14.5 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Mtr 195.0 626.27 122122.65 vi) DSR_2025_7.14.6 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Mtr 80.0 766.1 61288.0 vii) DSR_2025_7.14.7 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Mtr 65.0 905.08 58830.2 viii) DSR_2025_7.14.8 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Mtr 91.0 980.51 89226.41 ix) DSR_2025_7.14.9 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm Mtr 121.0 1035.59 125306.39 x) DSR_2025_7.14.10 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm Mtr 98.0 1089.83 106803.34 xi) DSR_2025_7.14.11 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm Mtr 115.0 1120.34 128839.1 xii) DSR_2025_7.14.12 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm Mtr 71.0 1159.32 82311.72 1110765.27 |
| 90 | i) NDSR 40 mm NB Mtr 20.0 428.0 8560.0 ii) NDSR 32 mm NB Mtr 80.0 325.0 26000.0 iii) NDSR 25 mm NB Mtr 126.0 245.0 30870.0 |
| 91 | i) NDSR 2 core x 1 Sqmm Mtr 600.0 271.0 162600.0 |
| 92 | i) NDSR 2 core x 1 Sqmm Mtr 700.0 61.0 42700.0 |
| 93 | i) DSR_2025_7.13.1 Indoor Units Nos 1.0 3843.22 3843.22 ii) DSR_2025_7.13.2 Outdoor Multi Joint Nos 1.0 6862.71 6862.71 858743.93 |
| 94 | (i) DSR_2025_30.12.2.4 Thickness 1.25 mm sheet Sqmtr 65.0 1748.31 113640.15 (i) DSR_2025_30.12.2.3 Thickness 1.00 mm sheet Sqmtr 165.0 1568.64 258825.6 (ii) DSR_2025_30.12.2.2 Thickness 0.80 mm sheet Sqmtr 350.0 1199.15 419702.5 (iii) DSR_2025_30.12.2.1 Thickness 0.63 mm sheet Sqmtr 490.0 1027.97 503705.3 |
| 95 | (i) NDSR 10 mm thick open cell nitrile rubber. Sqmtr 200.0 817.0 163400.0 |
| 96 | (i) DSR_2025_30.23.1 19 mm Thick Al faced Sqmtr 900.0 686.44 617796.0 2077069.55 |
| 97 | DSR_2025_30.15 |
| 98 | DSR_2025_30.16 |
| 99 | DSR_2025_30.17 |
| 100 | DSR_2025_30.18 |
| 101 | DSR_2025_30.13 |
| 102 | (i) DSR_2025_30.14.1 Damper Sqmtr 8.0 15573.73 124589.84 (ii) DSR_2025_30.14.2 Actuator Each 8.0 8299.15 66393.2 1709674.56 |
| 103 | i) NDSR 18.5 KW , 3-phase, Star Delta Starter Nos 4.0 24500.0 98000.0 ii) NDSR 15 KW , 3-phase, Star Delta Starter Nos 11.0 24500.0 269500.0 iii) NDSR 11 KW , 3-phase, Star Delta Starter Nos 2.0 24500.0 49000.0 iv) NDSR 7.5 KW , 3-phase, Star Delta Starter Nos 8.0 24500.0 196000.0 v) NDSR 5.5 KW , 3-phase, Star Delta Starter Nos 1.0 24500.0 24500.0 vi) NDSR 3.7 KW , 3-phase, Direct On Line (DOL) Starter Nos 2.0 17500.0 35000.0 vii) NDSR 2.2 KW , 3-phase, Direct On Line (DOL) Starter Nos 1.0 17500.0 17500.0 viii) NDSR 0.75 KW , 3-phase, Direct On Line (DOL) Starter Nos 2.0 17500.0 35000.0 |
| 104 | i) NDSR 4 core 16 sqmm copper armoured cable Mtr 50.0 1698.0 84900.0 ii) NDSR 4 core 10 sqmm copper armoured cable Mtr 50.0 1161.0 58050.0 iii) NDSR 4 core 6 sqmm copper armoured cable Mtr 50.0 721.0 36050.0 |
| 105 | i) NDSR 3.5 core 25 sqmm copper armoured cable Mtr 400.0 382.0 152800.0 ii) NDSR 4 core 16 sqmm copper armoured cable Mtr 350.0 349.0 122150.0 iii) NDSR 4 core 10 sqmm copper armoured cable Mtr 230.0 324.0 74520.0 1313170.0 TOTAL 21103684.99 A FIRE DETECTION AND ALARM SYSTEM |
| 106 | DSR_2025_28.2.10 |
| 107 | DSR_2025_28.2.13 |
| 108 | DSR_2025_28.2.15 |
| 109 | DSR_2025_28.2.14 |
| 110 | DSR_2025_28.2.5 |
| 111 | DSR_2025_28.2.12 |
| 112 | DSR_2025_28.5.2 |
| 113 | DSR_2025_28.2.17 |
| 114 | DSR_2025_28.2.19 3849737.66 B PUBLIC ADDRESS SYSTEMS |
| 115 | DSR_2025_28.3.9 |
| 116 | DSR_2025_28.3.2 |
| 117 | DSR_2025_28.5.2 998958.25 C CCTV & DATA SYSTEMS |
| 118 | DSR_2025_39.1.1 |
| 119 | DSR_2025_39.3.1 |
| 120 | DSR_2025_39.11 |
| 121 | DSR_2025_39.12.1 |
| 122 | DSR_2025_39.14 |
| 123 | (i) DSR_2025_39.17.1 1 Run of cable Mtr 500.0 62.71 31355.0 (ii) DSR_2025_39.17.2 2 Run of cable Mtr 700.0 105.08 73556.0 (iii) DSR_2025_39.17.3 3 Run of cable Mtr 2000.0 147.46 294920.0 (iv) DSR_2025_39.17.4 4 Run of cable Mtr 2000.0 189.83 379660.0 |
| 124 | (i) DSR_2025_39.21.1 6 Port LIU Each 5.0 4636.44 23182.2 (ii) DSR_2025_39.21.2 12 Port LIU Each 5.0 5966.1 29830.5 (iii) DSR_2025_39.21.3 24 Port LIU Each 1.0 8516.1 8516.1 |
| 125 | (i) DSR_2025_39.23.1 6U Rack Each 3.0 5880.51 17641.53 (ii) DSR_2025_39.23.2 9U Rack Each 3.0 7593.22 22779.66 (iii) DSR_2025_39.23.3 15U Rack Each 4.0 11296.61 45186.44 |
| 126 | DSR_2025_39.24 |
| 127 | (i) DSR_2025_39.19.1 Single Mode 6 Core Optical fiber cable RM 500.0 54.24 27120.0 |
| 128 | (i) DSR_2025_1.18.1 1 Pair Mtr 100.0 27.97 2797.0 (ii) DSR_2025_1.18.2 2 Pair Mtr 150.0 33.05 4957.5 (iii) DSR_2025_1.18.3 4 Pair Mtr 200.0 44.92 8984.0 1333830.32 |
| 129 | DSR_2025_39.7 578110.2 Total 1911940.52 |
| 130 | NDSR 497284.0 7257920.43 Gross Total (A+B+C+D+E) 134473848.07 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender