Public Administrative Department Government Departments Closing in 2 days TDR #56430082

Tender For Construction Of Roads-T06- T06 - Tuilaphai To Tuikot Block: Henglep District: Churachandpur State: Manipur

Issued by Government Departments · Imphal West, Manipur
Tender Value
8.29 Crore
Estimated cost
Bid Submission
31 Jul 2026
2 days left
EMD
16.58 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Imphal West → Manipur
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Construction Of Roads-T06- T06 - Tuilaphai To Tuikot Block: Henglep District: Churachandpur State: Manipur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 16-Jul-2026 Corrigendum 1 Fee 25-Jul-2026
2 22-Jul-2026 Corrigendum 5 Date 31-Jul-2026
3 21-Jul-2026 Corrigendum No. 3 and 4 Technical Bid 31-Jul-2026
4 18-Jul-2026 Corrigendum 2 Fee 31-Jul-2026
5 16-Jul-2026 Corrigendum 1 Fee 31-Jul-2026

BOQ

Name of Work:- T06- T06 - Tuilaphai to Tuikot Block: Henglep District: Churachandpur State: Manipur
Sl. No. Item Description
1A. PAVEMENT WORKS
2Clearing and Grubbing Road Land.Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.(I) By Manual Means(B) In area of thorny jungle
3Construction of Embankment with Material Obtained from Borrow PitsConstruction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5Private Land
4Earthwork in Hill RoadExcavation in Hilly Areas in Soil by mechanical means. Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1
5Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3
6Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical MeansScarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
7Construction of Subgrade and Earthen ShouldersConstruction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.(i) Private Land
8Considering 75% for Re-use of Existing Materials
925% for fresh Materials
10Cement Treated Granular BaseProviding laying and spreading granulated material on a prepared sub-grade pulverising adding the designed quantitity of cement,to the spread granulated material mixing in place with rotavator grading with the mortar grader and compacting with smooth wheel roller 80-100 kN at OMC to achieve the desired unconfined compressive strength and to form a layer of sub- base/base as per Technical Specifications Clauses 404.3 and 410.4.2.
11Prime Coat :Low porosityProviding and applying primer coat with bitumen emulsion (CSS-1) on prepared surface of granular base/WBM/WMM including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
12Mix Seal SurfacingProviding, laying and rolling of close-graded premix surfacing material of 25mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509By Mechanical Means, Type A, Bitumen (S-90)
13Tack CoatProviding and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
14B.ROAD FURNITURE WORKS
15Providing and Fixing 'Logo' of PMGSY ProjectProviding and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
16Providing and Fixing Title information Board of PMGSY Project (RCC)Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing including painting and lettering and fixing in ground 600mm x 600mm x 750mm CC including painting two course and lettering.Providing & Fixing Up-gradation Board
17Providing and Fixing Title information Board of PMGSY Project (RCC)Providing and fixing of typical PMGSY Maintenance information sign board as per MORD specifications and drawing including painting and lettering and fixing in ground 600mm x 600mm x 750mm CC including painting two course and lettering.
18Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703
19(i) 5th Kilometre Stone (precast)
20(ii) Ordinary Kilometer stone (precast)
21(iii) 200m Stone (precast)
22Construction of Job pillars as per Fig. 1600.1 (d) and Technical Specification Clause 1602.4
23Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New WorkPainting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702
24Traffic SignsProviding and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflectivesheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm belowground level as per drawings and Technical Specification Clause 801
25(ii) 600mm equilateral triangle
26(iii) 600mm circular
27Rumble StripsProvision of 15 nos.rumble strips covered with premix bituminous carpet,15.2 mm high at centre,250mm wide placed at 1m centre to centre at approved location to control speed, marked with white strips of road marking paint.The rate per sqm of premix carpet and road marking may be adopted from Chapters 5&10 respectively for the quantities calculated from approved drawings.
28C. DRAINAGE WORKS
29Construction of unlined surface drain of average cross-sectional area 0.4 sqm in ordinary rock to specified lines, grades, levels and dimensions as per approved design and Technical Specification Clause 307. Excavated material to be used in embankment at site.(B) Mechanical Means, Excavation for Structures
30Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth Excavation for Structures
31Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203P.C.C grade M 10Nominal mix 1:3:6
32Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204PCC Grade M 20Nominial mix (1:2:4)
33Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
34Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
35D. CD WORKS
36Cross drainage srtructures (24 no's 1000 Dia Pipe culvert)
37Excavation for StructuresEarthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
38Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
39Bedding for PipeType B (First Class) BeddingLaying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105
40Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single RowProviding and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding (B) 1000 mm dia
41Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203P.C.C. grade M 20Nominal mix (1:2:4)
42Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204P.C.C. grade M 20Nominal mix (1:2:4)
43Cross drainage srtructures (3 no's 1.5m slab culvert)
44Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
45Ordinary soil upto 3 m depth
46Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6
47Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203PCC Grade M 20Nominial mix (1:2:4) (Hand mixed)
48Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204PCC Grade M 20Nominial mix (1:2:4)
49Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
50Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5RCC Grade M 20(i) Nominal Mix 1 : 2 : 4
51Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
52Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
53Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
54Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
55Providing and laying curtain walls complete as per drawing and technical specification Clause 1304Cement concrete grade M 10
56Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
57Filler JointProviding and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans, covered with sealant complete as per drawing and technical specifications
58Cross drainage srtructures ( 4 no's 2m slab culvert)t)
59Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
60Ordinary soil upto 3 m depth
61Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6
62Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203PCC Grade M 20Nominial mix (1:2:4) (Hand mixed)
63Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204PCC Grade M 20Nominial mix (1:2:4)
64Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment,wing wall, return wall with 100 mm dia AC pipe extending through the full width of thestructures with slope of 1(V):20(H) towards drawing face complete as per drawing andtechnical specification Clauses 614, 709, 1204.3.7
65Providing and laying reinforced cement concrete in superstructure as per drawing andtechnical specifications Clauses 800, 1205.4 and 1205.5RCC Grade M 20(i) Nominal Mix 1 : 2 : 4
66Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
67Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
68Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
69Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
70Providing and laying curtain walls complete as per drawing and technical specification Clause 1304Cement concrete grade M 10
71Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
72Filler JointProviding and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans, covered with sealant complete as per drawing and technical specifications
73Cross drainage srtructures ( 2no's 3m slab culvert )t)t)
74Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
75Ordinary soil upto 3 m depth
76Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6
77Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203PCC Grade M 20Nominial mix (1:2:4) (Hand mixed)
78Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204PCC Grade M 20Nominial mix (1:2:4)
79Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment,wing wall, return wall with 100 mm dia AC pipe extending through the full width of thestructures with slope of 1(V):20(H) towards drawing face complete as per drawing andtechnical specification Clauses 614, 709, 1204.3.7
80Providing and laying reinforced cement concrete in superstructure as per drawing andtechnical specifications Clauses 800, 1205.4 and 1205.5RCC Grade M 20(i) Nominal Mix 1 : 2 : 4
81Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
82Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
83Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
84Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
85Providing and laying curtain walls complete as per drawing and technical specification Clause 1304Cement concrete grade M 10
86Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
87Filler JointProviding and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans, covered with sealant complete as per drawing and technical specifications
88Cross drainage srtructures (1 no 4m slab culvert)
89Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
90Ordinary soil upto 3 m depth
91Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6 [Hand Mixing]
92Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203PCC Grade M 20Nominial mix (1:2:4)
93Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204PCC Grade M 20Nominial mix (1:2:4)
94Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
95Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. R.C.C grade M 20 For design mix RCC M 20
96Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
97Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
98Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
99Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
100Providing and laying curtain walls complete as per drawing and technical specification Clause 1304Cement concrete grade M 10
101Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
102Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans, covered with sealant complete as per drawing and technical specifications
103Routine Maintenance Component for 5 (Five) years after Construction (Not To Be Quoted Yearwise)
1041st Year in INR - ₹ 882000
1052nd Year in INR - ₹ 1322000
1063rd Year in INR - ₹ 1763000
1074th Year in INR - ₹ 2204000
1085th Year in INR - ₹ 2644000 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56430082
AUTHORITY Government Departments
TENDER VALUE 8.29 Crore
LAST DATE 31-07-2026
Authority
Authority Name Rural Engineering Department
Work Description Tender For Construction Of Roads-T06- T06 - Tuilaphai To Tuikot Block: Henglep District: Churachandpur State: Manipur
Basic Detail
Tender No MSRRDA/E-TENDER/PMGSY-III, B-I, 2023-24/RT-3/NIT-6
Bidding Type Tender
Location
City Imphal West
State Manipur
Key Dates
Publish Date 22 Jul 2026
Submission Date 31 Jul 2026
Open Date 31 Jul 2026
Finance
Tender Value 8.29 Crore
Tender Fee 20000
EMD 16.58 Lakhs
Exemption Not Available
Document List
BOQ_233405.xls
c2a15a13-ade3-4ec3-86e3-4c0ef3f59a60.html
Tendernotice_1 (6).pdf
Tendernotice_2 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 25, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 31, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Jul 31, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Jul 31, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Jul 31, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_233405.xls

html

c2a15a13-ade3-4ec3-86e3-4c0ef3f59a60.html

pdf

Tendernotice_1 (6).pdf

pdf

Tendernotice_2 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders