Tender For Providing Of Swimming Pool At Fazilka On Epc Mode
Tender Value
13.69 Crore
Estimated cost
Bid Submission
07 Aug 2026
24 days left
EMD
10.99 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Fazilka → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Providing Of Swimming Pool At Fazilka On Epc Mode
BOQ
| Sl. No. | Item Description |
| 1 | Lump sum price worked out by the tenderer for “BUILDING WORK\\" as listed in Schedule ‘A’ Part - I |
| 2 | Subtotal |
| 3 | Lump sum price worked out by the tenderer for “SITE CLEARANCE & DEVELOPMENT, EXCAVATION AND EARTHWORK WORKS\\" as listed in Schedule ‘A’ Part -II |
| 4 | Subtotal |
| 5 | Lump sum price worked out by the tenderer for “ROAD , PATH & CULVERTS WORKS\\" as listed in Schedule ‘A’ Part - III |
| 6 | Subtotal |
| 7 | Lump sum price worked out by the tenderer for “AREA DRAINAGE WORKS\\" as listed in Schedule ‘A’ Part -IV |
| 8 | Subtotal |
| 9 | Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS\\" as listed in Schedule ‘A’ Part V |
| 10 | Subtotal |
| 11 | Lump sum price worked out by the tenderer for “COMPOUND WALL, SECURITY WALL & GATE WORKS\\" as listed in Schedule ‘A’ Part -VI |
| 12 | Subtotal |
| 13 | Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part -VII |
| 14 | Subtotal |
| 15 | Lump sum price worked out by the tenderer for “SUMMER APPLIANCES WORKS\\" as listed in Schedule ‘A’ Part -VIII |
| 16 | Subtotal |
| 17 | Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIC SUPPLY WORKS\\" as listed in Schedule ‘A’ Part -IX |
| 18 | Subtotal |
| 19 | Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORK\\" as listed in Schedule ‘A’ Part - X |
| 20 | Subtotal |
| 21 | Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS\\" as listed in Schedule ‘A’ Part - XI |
| 22 | Subtotal |
| 23 | Lump sum price worked out by the tenderer for “MISCELLANEOUS WORKS\\" as listed in Schedule ‘A’ Part -XII |
| 24 | M&L for Grassing with “Selection No. 1” grass including enough watering and maintenance of the lawn till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed including supplying and spreading of Neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. |
| 25 | Material and labour for digging holes of 60cm dia and 90cm depth in any type of soil and refilling the same with the earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water filling with earth if necessary and finally fine dressing, levelling etc including removal of surplus earth if any and declared unserviceable earth to a distance not exceeding 100 m and depositing where directed by spreading and levelling at a level not exceeding 1 metre above the starting point including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 3 to 4 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying in suitable size of poly bag, stacking and planting of following trees/plant including maintenance of the plants for 6 Months or more till the plants fit for mowing complete all as specified and directed by engr in charge. Note: (a) Cost for the excavation, earthworks, manure (well decomposed cow dung/meegni manure), sludge, anti-termite treatment, pesticide, watering etc. during contract period and during maintenance period shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (b) Excavated earth if not found suitable for growth of grass and good earth for mixing if required as per direction of Engineer-in-charge same (supplying of good earth from outside MD land) shall also deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 26 | Araucaria Cookie Plant (Araucaria Cookii leaf on tree, also known as Cook Pine or Coral Reef Araucaria) of height not less than 5 feet |
| 27 | Ashoka Potala Regional plant of height not less than 5 feet |
| 28 | Cassia golden shower (fistula/biflora) flower tree of height not less than 5 feet |
| 29 | Gulmohar of height not less than 5 feet |
| 30 | Jamun of height not less than 5 feet |
| 31 | Kinoo (Kennow) Tree of height not less than 5 feet |
| 32 | Mahogany tree of height not less than 5 feet |
| 33 | Neem Tree of height not less than 5 feet |
| 34 | Pakad Tree (Ficus virens, also known as the Pilkhan tree) of height not less than 5 feet |
| 35 | Palm Tree of height not less than 5 feet |
| 36 | Peepal Tree of height not less than 5 feet |
| 37 | Sheesham Tree of height not less than 5 feet |
| 38 | Tamarind (Tamarindus indica) Tree of height not less than 5 feet |
| 39 | Fruit bearing trees (any type as directed by GE) of height not less than 5 feet |
| 40 | Phoenix canariensis (Canary Island date palm) tree of height not less than 12 feet |
| 41 | Material and labour for digging holes of 45cm dia and 60cm depth in any type of soil and refilling the same with the earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water filling with earth if necessary and finally fine dressing, levelling etc including removal of surplus earth if any and declared unserviceable earth to a distance not exceeding 100 m and depositing where directed by spreading and levelling at a level not exceeding 1 metre above the starting point including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 3 to 4 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying in suitable size of poly bag, stacking and planting of following trees/plant including maintenance of the plants for 6 Months or more till the plants fit for mowing complete all as specified and directed by engr in charge. Note: (a) Cost for the excavation, earthworks, manure (well decomposed cow dung/meegni manure), sludge, anti-termite treatment, pesticide, watering etc. during contract period and during maintenance period shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (b) Excavated earth if not found suitable for growth of grass and good earth for mixing if required as per direction of Engineer-in-charge same (supplying of good earth from outside MD land) shall also deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 42 | Anarmi plant (Creeper Plant) of height not less than 1 feet |
| 43 | Harsingar plant (also known as Night-flowering Jasmine or Parijat) of height not less than 1 feet |
| 44 | Rangoon Creeper Plant (Madhumalati Vine) commonly known as many names like Burma Creeper, Honeysuckle Plant etc shrub flowering Plants of height not less than 1 feet |
| 45 | Plumeria (frangipani) flowering Plant of height not less than 2 feet |
| 46 | Flowering Plant (any colour) of height not less than 2 feet, like ticoma / rose / motia / chandni / Ixora / marigold / vinca etc as directed by GE |
| 47 | Supply and planting of hedge shrubbery (Inermi Hedge boundary plantation trees, Distance between two hedge plant shall not be more than 15 cm, minimum 6 plants per RM), height of plant 2 to 3 feet, including creation of beds by excavating 45 cm deep and 60 cm wide trenching excavated base, refilling the excavation earth after breaking of clods and mixing with manure of sludge on the ratio 1:8 ( 8 parts of stacked volume of earth after reducing 20 % with one part of stacked volume of sludge or manure after reduction by 8%) flooding with water filling with earth if necessary and finally fine dressing, levelling etc including removal of surplus earth if any and declared unserviceable earth to a distance not exceeding 100 m and depositing where directed by spreading and levelling at a level not exceeding 1 metre above the starting point including anti-termite treatment by digging 30 cm deep and 4 cm dia, 1 holes near trunk using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including maintenance of the hedge for 6 Months or more till the hedge fit for mowing complete all as specified and directed by engineer-in-charge. Note: (a) Cost for the excavation, earthworks, manure (well decomposed cow dung/meegni manure), sludge, anti-termite treatment, pesticide, etc. during contract period and during maintenance period shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (b) Excavated earth if not found suitable for growth of plants and good earth for mixing if required as per direction of Engineer-in-charge same (supplying of good earth from outside MD land) shall also deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 48 | M&L for maintenance of the plants/hedge/grass by weeding, hosing,saucer making once in every month for plants/hedge,once in every 15 days for carpet grass/country grass/doob grass, bermuda grass,pruning dried ranches once in every week, depositing the material at place as directed y Engr-in-charge and planting the new plants in place of dead plants of same species and height turning with dods wherever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. |
| 49 | S&F precast RCC 1:1.5:3 type A-1, lawn bench and back support of size 1.50x0.60 m of maximum three person seating capacity supporting precast RCC type A-1 for back & base with including assemble the precast member with suitable nut & bolt and placing and anchoring with hold fast 350 mm-16mm dia MS bar on concrete base (size 1.20x0.60 m for each support) with 100 mm thick PCC 1:2:4 Type B-1 over 150 mm thick sub base 1:4:8 type D2 complete all as specified and as directed by Engineer in Charge. |
| 50 | All as shown on drawing. Overall size shall be 460mm long, 600mm deep and 760mm high. Legs shall be of 20mm dia mild steel conduit of wall thickness 1.6mm standing 70mm horizontally for a vertical height of 355mm at front up to seat level. The horizontal distance between legs at seat level shall be 450mm and between bottom of legs shall be 600mm. The rear legs shall slant 80mm horizontally for 300mm height at the back of seat level to bottom of rear legs. The seat frame shall be welded to the frame of legs. The seat frame with back seat shall be of continuous 20mm dia mild steel conduct of wall thickness 1.6mm two 20mm dia mild steel tube conduct shall be welded at the back rest and the rear of seat in such a way that the New PVC seat 3 mm thick PPCP 3 mm thick not less than 0.39 Kgs seat Make - AMCO, Cello, Comfo & Equitant shall be used. All fittings & fixture shall be done accordance with standard wk manship. Rest all as per drg. FD/Map-ll/06 |
| 51 | The bench shall be manufactured using stainless steel using 304/316 grade matt finished as per design. Stainless steel plate shall be of 16 gauge, Overall length will be 1750 mm width should be of 450mm clear height of bench with back rest should be 890 mm all surfaces of bench should be unifrom smooth mirror finish welding joints shall be finished ensuring that no welding marks are visible. Paint over a coat of primer with spray machine after prepration of stainless suface. Rest all as directed by Engineer-in-Charge. TP |
| 52 | All as shown on drawing. Overall size shall be 450mm, 300mm wide and 380 high. Legs shall be of teak wood of section 30X50mm. The legs shall be 362mm high. 5mm X5mm in section groove shall be provided on the top of legs which shall be visible when placed in position. Two numbers top rails of section 20mmX40mm of teak wood shail be provided connecting legs. The length of top rails shall be 380mm. Two numbers bottom rails of section 20X40mm of teak wood shall be provided connecting legs in short sides. Bottom rails shall be fixed at 100mm from the bottom of legs. Top shall be of 18mm particle board commercial with 1.5mm thick plastic laminated sheet fixed over it. 4mm thick teak wood edging shall be provided all around the top edge of table. All wood surfaces exposed to view when placed in position shall be French polished with high gloss finish. FD/Map/11 |
| 53 | Supply of vertical fibre glass filter of 2.00M dia made of polyester shell with a liner employing special version with polypropylene arm collector, and PVC distribution network with a net filtering area of 3.14Sq.m capable of filtering @123000Ltr / hr / at 40000Ltrs / Sq.mt/ hr of filter bed area with inlet & outlet opening of 160mm dia flange. as per standard design for the efficient working of the system complete with first charge of the filter media. ( out let size cannot be lesser than 125mm dia) Model : AS2000C |
| 54 | Supply of Grade 1 sand Media 50kg in bags |
| 55 | FILTER MEDIA Supply of Valve batteries made in Zinc plated steel, consisting of 5 Nos, 160mm dia PVC butterfly Valve, suitable mounting supports, pressure gauge with required size inlet. outlet, flanges & 2 support brackets with suitable clamps & fixing screws. ( valve size cannot be lesser than 125mm dia & respeCtive piping) |
| 56 | Supply of Centrifugal self-priming pump with high hydraulic efficiency, chemical resistant and ultra-quiet operation. Integrated along with IP-55 protection- class F continuous rating high efficiency IE3 motors. Pump shall be of two-piece body made in polypropylene 30%+ GF, integrated polypropylene 30% + GF pre-filter with strainer basket, fast opening translucent transparent polycarbonate lid, easy opening metal knob lid system, 316 SS Shaft and mechanical seal. Bronze impeller, flanged end connections 125mm suction & 100mm return union connections, Horse power: 10 HP,7.5 Kw, Phase: III phase 400V, FLOW CONDITIONS =125m³/hr @ 13 m water head. with 5 year warranty ( MAXIMUM POWER CANNOT BE MORE THAN 10HP & IT MUST BE IE3 MOTORS) |
| 57 | Supplying of manual chlorine dosing system 20LPH @ 5 BAR with pH controller and necessary pumps, along with 500 LTR mixing tanks and 900MM manual agitators |
| 58 | Supply of Commercial VGE UV system Model VGE pro 600-219 is designed to work at Medium pressure capable to dose UV at a rate of 400J/m2. The unit shall be made of SS316L body with U shape irradiation reactor chamber with 6 BAR maximum pressure rating. The unit shall be capable to work around 140 cumtr/ hr flow with a 125mm connection. The unit shall used AOP , Advanced oxidation processes . The UV comes with control panel and monitor with sensors to check UV & temperature. The units UV Lamp shall be placed to perpendicular to the direction of flow. The Lamp base shall be equipped with SMART PIN TECHNOLOGY where the lamp shall be removed when the system is pressurised. The UV lamp expected life time shall be 16000 hrs. The end connections shall be of 125mm dia SS flanges. .( Multiple qty of residential not allowed) |
| 59 | Supply of UPVC 10 kg/sqcm Piping including necessary fitting such as Elbows, Bends, Sockets, Tees, Collars, Nipples, Reducers, Stub Ends, diminishing pieces, Solvent Cement, etc. for Swimming Pool Inlet & Drain & Suction piping, Swimming Pool filtration plant piping, drain pipe along the pipe periphery including all fittings, fixtures and Ceiling/ Wall Support System suitable for following uPVC pipe as specified and directed. |
| 60 | a) 315mm dia - 10Kg pipe |
| 61 | b) 250mm dia - 10Kg pipe |
| 62 | d) 200mm dia - 10Kg pipe |
| 63 | d) 160mm dia - 10Kg pipe |
| 64 | e) 63 mm dia - 10Kg pipe |
| 65 | Valves :Supply of butterfly valves with standard lever. Confirming to BS, Standards with necessary flanges, nuts and bolts etc., |
| 66 | a) 315mm dia Butterfly Valve With Flange adaptors |
| 67 | b) 250 mm dia Butterfly Valve With Flange adaptors |
| 68 | c) 160mm dia Butterfly Valve With Flange adaptors |
| 69 | Supply of U-PVC Non return valve confirming to BS Standards with necessary flanges, nuts and bolts etc complete |
| 70 | a) 315mm dia Flap check Valve with flange adaptors |
| 71 | b) 160mm dia Flap check valve with flange adaptors |
| 72 | Supply only evaporative air coolers (desert coolers) as per IS 3315:2019 sump tank capacity not less than 80 liters, single phase having air flow capacity 4000 cum per hrs, cooling efficiency not less than 65 %, maximum power consumption 300 watts, plastic body, noise level not more than 65dBA at 1 m distance, honeycomb pads complete all as specified and directed. |
| 73 | Supply, install, commissioning of refrigerator electric driven single phase capacity up to 330 litres direct cool, single door, BEE 5 star rated with AI auto defrost rapid freeze technology, stablizer free operation, inverter compressor, on door digital control panel, copper condenser and evaporator latest technology complete all as specified and directed by Engineer-in-Charge. Make: Lloyd, LG, Godrej. |
| 74 | Supply of Air cooled Heat Pump delivering actual capacity as per the following parameters. Heat pump shall be rated at Nominal Input Power -2000 Watt with Output Heating capacity - 6 KW,Electrical Backup - 2.2 KW having Inbuilt Tank capacity - 450 litres having glass lining. Water Temp in efficiency mode using compressor should be 65 degree C. Heat pump should have all the safety protections like high/low voltage , high temperature, refrigeratnt leak, compressor overheting protection with operational noise level not more than 60 dbA. Heat pump should have a user freindly control panel to set the desired temperature showcasing the actual temp |
| 75 | Supply install test and commisioning of Pool under water integral LED model 14.4 Watt, wall mounted type working on 12 V DC, IP68 complete with built-in driver, including push in connector in 4 pole, flexible conduit and all fixing arrangement in swimming pool wall including and flexible conduit accommodate pool light . |
| 76 | Supply install test and commisioning ofJunction box of suitable size round/square type with water proof covering made of ABS plastic material. |
| 77 | Supply, and lay in conduit, under floor, on wall, of 2 core 2.5 sq.mm. PVC insulated FRLSH copper conductor 1100 Grade unarmoured cable Wiring from under water lights to distribution panel all as directed and specified by Engineer-in-Charge. |
| 78 | Supply, installation, testing and commissioning of heavy duty PVC conduit 20 mm PVC, ISI marked conduits complete with accessories such as bends, junction boxes, pull boxes etc. |
| 79 | Supply, installation, testing and commissioning of water proof Distribution box for under water lights drivers and MCB all as directed and specified by Engineer-in-Charge. |
| 80 | Supply and fix galvanised stay strand wire 7/4mm suitable for staying of poles including Stay assembly complete withaccessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete etc are including in this items ) complete all as specified and directed . |
| 81 | Supply and laying double wall corrugated pipe (DWCP), Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating, conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable complete all as specified and directed by Engr - in charge |
| 82 | DWC Pipe dia 77/63 |
| 83 | DWC Pipe dia 120/103 |
| 84 | Supply, installation, testing and commissioning outdoor type Compact Sub – Station (CSS) comprising 11KV, 630 Amp VCB, 100KVA Copper Wound Oil Cooled Off Circuit Transformer & LT Panel with base and trenches for cable with cover by use suitable material PCC, plaster and bricks Complete all as specified and as directed including the following:-(a) HT Section:- (i) 11 kV, 630 Amp, Indoor Type, VCB Horizontal Draw out Horizontal isolation floor mounting motorized panel with 230v motor mechanism & 24v DC Shunt/Close coil with CT, PT, IDMT Relay, 8 Window Enunciator Model No. SI-801, Battery Power Pack with 7AH Battery & in built charger for 24V Circuit and other fittings & accessories. Nos 01.(ii) Potential Transformer – 3 Phase cast resin of ratio 11kV/110V, Class-0.5, 100VA with HT Primary Fuses. (Nos 03).(iii) Current Transformer –Cast resin Ratio: 60-30/5+5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10, 15VA (Nos 01)(iv) Protection :- Numerical 2OC + 1EF Relay and Auxiliary Relay. (Set one)(v) Micro Processed based Non-Directional IDMT. (Nos 01)(vi) Indication Lamps:- VCB off / on / auto trip/ Trip circuit healthy/spring charge indication (set one)(vii) Metering:- Digital Ammeter & Digital Volt Meter (Set one)(b) Transformer Section:- Transformer 100 KVA, 11/0.433 KV, 3 Phase, 50HZ, ONAN Cooled Oil immersed Copper Wound Step Down “BIS Marked” Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI & Marshalling Box. Transformer as per IS-1180:2014 EEL- 2 with amendment no.- 1,2,3 & 4 Formerly EEL- 3 (till 30.3.2022) Losses @50% Load - 955W Losses @100% Load - 2750W (c) LT Section:- LT Panel comprising of LV Side Incomer – 01 no. -300 Amp 4 Pole 415V 25 KA MCCB with thermal magnetic based release with O/L & S/C protection. - RYB Indication |
| 85 | (d) Enclosure Section(i) Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control(ii) MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel.(iii) Provision for receiving Incoming cables thro Bottom entry and out going(iv) through Bus bar to Trf panel, Excluding Termination Kit & Glands(v) Provision for receiving Incoming through bus duct by bus bar and Outgoing thro cable box bottom entry Excluding Termination Kit & Glands(vi) Bus Bar – Aluminum(vii) Earth Bus – Aluminum(viii) Paint shade: Siemens Grey ( RAL 7032)(ix) provn of platform for mounting CSS as per given size rate to be deemed in BOQ rate of this item. |
| 86 | Supply and install galvanized steel High Mast of 16Mtrs height lighting system in two section, 3 mm section thickness, top dia not less than 150mm & bottom dia not less than 340mm with its accessories including foundation bolts manufactured from special steel and Hopt Dip galvanised along with nuts, washers, anchor plates and templates, feeder pillar panel control and raising 7lowering mechanism for integralpower tool, Twin aviation lamp etc. mast shaft shall be in two sections, hot dip galvanized and suitable for wind velocity as per IS 875 part 3 minimum 18 per hour. It shall also include accessories for high mast including mast including head frame, steel wir rope (7/19 construction) double frum is operated by motor gear mechanism with inbuilt starter, timer and feeder piller panel, galvanized lantern carriage arrangement suitable for 08 Nos, liminaires Symmertrically & its control gear boxes and with 03 point suspension system. the mast shall have an integral power tool installed inside the base compartment for its operation. (material construction of high mast sheet will be BESEN 10025/ IS 5986 or eqivalent) with wiring cable for luminaire connection including suitable size of foundation for 16.0 mtr high mast considering the soil bearing capacity 10 T/sq mtr at 2 meter depth and using RCC M-25 grade (design mix) concrete with reinforcement, from work, earthwork complete all as per manufacturers instructions and as directed by Eng-in-charge.Note:(a) making of civil foundation for erection of high mast and feeder pillar panel as per manufacturer recommendation demeed to be including in the unit rate. (b) Cable of required size and lenght from top to bottom for connection og LED flood light an related switchgears including quoated rate. |
| 87 | Supply, Install, testing & commissioning factory made Out door type dust and vermin proof Feeder pillar LT panel board cubical double door hinged type compartmentalized of suitable size 415 volts, AC 50 Hz fabricated of CRCA sheet 3 mm thick machine pressed and angle iron frame 50mm x 50mmx 6mm grouted in PCC 1:2:4 type B1 (20mm grade stone aggregated) powder coated inside and outside complete including 4 poles aluminium bus bar of suitable size mouned on porcelain insulators and enclosed in chamber made out od 2mm thick CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles / lugs cable gland with open able shutters on both side and comprising of the following :- |
| 88 | (i) in comming MCCB 200 Amp, 50 KA, 4 Pole 415 Volt - 01 Nos |
| 89 | (ii) Out going MCCB 120 Amp, 36 KA 4 Pole 415 Volt, - 01 Nos |
| 90 | (iii) Out going MCCB 63 Amp, 36 KA 4 Pole 415 Volt, - 01 Nos |
| 91 | (iv) out going MCCB 32 Amp 4 pole 415 volt 10 KA - 03 Nos |
| 92 | (v) Timer |
| 93 | (vi) Aluminium bus bar for 3 Ph & Neutral 300 Amp- 01 Set |
| 94 | (vii) Volt meter 0-500V |
| 95 | (viii) Ammeter with CTs 50 A rang and selector switch |
| 96 | (ix) Phase indicator lamps for 3 Ph -01 Set |
| 97 | Supplying, fixing,testing,& commissioning intergal decorative Water proof 9 Watt LED bollard light with opal acrylic with IP-65 protection with inbuilt driver, colour temperature of 5700 K of graphite grey powder coated finish type including PCC base with specified size complete all as specified and directed by Engr-in-Charge. |
| 98 | S&F Post top lantern Light of not less than 20 Watt capacity made of housing epoxy powder coated pressure die cast aluminium spigot and lid cover with graphite grey finish and clear acrylic cover, IP65 protction, including suitable mounting GI pipe to be fitted into the column / piller with all fitting and wiring and PCC grouting complete all as specified and directed |
| 99 | M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 100 | M&L for making coonection from existing water pipe line 200 mm bore and inserting of flanged Tee 200x200x150 mm with flanged socket 200 mm and jointing with rubber gasket, nut bolt etc. and making leak proof joint complete and making new connection with 200 mm HDPE water pipe line.Note:- Rate encludes the cost of cuttings of pipe, jointing of pipe and jointing material i.e. rubber gaskets, nut bolts, washer etc, and HDPE special fittings as required complete. |
| 101 | M&L for Construction of brick masonry valve pit of internal size 120cm x 120cm x 120 cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock, complete all as specified and directed by Engineer - in - Charge Note :-(i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds.(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B-1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Two coats of white wash to internal surfaces of valve pit.(vi) Depth of wall pit shall be reckoned from the top of PCC in foundation. |
| 102 | Subtotal Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 24 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer