Tender For Repair/Replacement Of Complete Re-Wiring Of Bldg No P-190, P-195, P-198, P-298, P-199, T-135 & T-136, Tr-117 & T-137Bc At 15 Corps Zonel Wksp Oaf Under Ge 970 Ews
Tender Value
43.68 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
18 days left
EMD
87500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Complete Re-Wiring Of Bldg No P-190, P-195, P-198, P-298, P-199, T-135 & T-136, Tr-117 & T-137Bc At 15 Corps Zonel Wksp Oaf Under Ge 970 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring from wooden battan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc. |
| 2 | Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed. |
| 3 | Taking down old MCCB,TPN DBs , SPN DBs alongwith SP/SPN MCB & Main Switch/enclosure box of any make and type from the site and making good surface complete all as specified and directed. |
| 4 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor drawn through new PVC conduit 20 mm dia medium grade ISI marked and all conduit accessories concealed in walls/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLSH as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular cover plate for housing of mudular switches , socket out let and fan regulators etc, complete all as specified and as directed for the followings:- |
| 5 | (a) One light/fan point controlled by one way switch. |
| 6 | (b) One bell point controlled by one way switch. |
| 7 | (c) One 3 pin socket outlet 5 Amp independent. |
| 8 | One 3 Pin socket outlet on the same board. |
| 9 | Ditto as above item No-4 with 3 pin socket outlet, 15 A, independent, with PVC copper conductor 4 Sqmm Size. |
| 10 | Material & Labour for point wiring complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box with 1.8 mm wall thickness, of suitable size for flush type switch with cover plate, cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. |
| 11 | (a) One light/fan point controlled by one way switch. |
| 12 | (b) One bell point controlled by one way switch. |
| 13 | (c) One 3 pin socket outlet 5 Amp independent. |
| 14 | (e ) One 3 Pin socket outlet on the same board. |
| 15 | (f) Ditto as above item No-4 with 3 pin socket outlet, 15 A, independent, with PVC copper conductor 4 Sqmm Size. |
| 16 | M & L Submain wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 volts grade in concealed New PVC conduit 25mm dia ISI marked alongwith one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. |
| 17 | S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLSH cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid in concealed New PVC conduit and conduit accessories complete all as specified and directed. |
| 18 | Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 19 | M&L in replacement Modular switch, 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 20 | M&L in replacement Modular Bell push, 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. |
| 21 | M&L in replacement Modular switch, 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge. |
| 22 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 23 | M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 24 | Suppy & fixing DB for MCB Protected Socket 15 Amps , PVC Plastic Base (white) with Plug top 25 Amps & MCB SP 32 amps complete all as specified and directed. |
| 25 | M&L ceiling rose 3 phase PVC polycorbonate,isolated body. |
| 26 | M&L bell ding dong AC,230 volts,single pole all as specified and directed by Engr in Charge. |
| 27 | Supply and fix LED batten luminaire surface mounted ,4 feet system wattage of not less than 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 4000 to 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 Lumens/watt, filcker free (Ripple less than 5%) and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed with 2 years of replacement warranty on fittings complete all as specified and directed. |
| 28 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of not less than 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 4000 to 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, Class - 1, SDCM <5 short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥120 Lumens/watt, filcker free (Ripple less than 5%) and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed with 2 years of replacement warranty on fittings complete all as specified and directed. |
| 29 | Supply and fix not less than 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 25,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. |
| 30 | S&F 35 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of sutable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 31 | S&F LED 2 X 2 ft backlite surface mounted fitting 36 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 25000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed. |
| 32 | Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. omplete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fix in repair MCCB 125 Amps, FP 415 volts 25 16KA, 4 pole 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge. |
| 34 | Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623. |
| 35 | S & F Electric water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank should be glass line coated complete all as specified of capacity 25 ltr having heating element up to 2 KW and not less than 5 star rating. Against def |
| 36 | Supply and fixing Exhaust fan 300 mm sweep(steel Body) , 900 RPM, steel body including metalic blade , single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. |
| 37 | Supply and fixing Ventilating Fan 250 mm sweep, 900 RPM, non metallic resin body, single phase 230 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. |
| 38 | M&L for breaking old existing wall and making a provn for fixing of 300 mm sweep exhaust fan/250 mm fresh air fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed. |
| 39 | Taking down carefully the existing ceiling fan of 1200mm from its position after disconnecting electric connection and checking its for its serviceability and deposite to MES store and as directed by Engineer-in- charge. |
| 40 | Hanging only ceiling fan any size (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan. |
| 41 | Taking down carefully the existing Geyser of 25/50 ltr from its position after disconnecting electric connection and checking its for its serviceability and re-fixing with connection pipe hot/cold as specified and directed by Engineer-in- charge. |
| 42 | M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. |
| 43 | S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection single door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete |
| 44 | S&F MCB ISOLATOR SPN 40 Amp, 'C' curve, 16 KA, 50 HZ, 240 volts |
| 45 | S&F MCB SP 6-32 Amps 240 volts 'C' curve series 10 KA 50 HZ complete all as specified and directed. |
| 46 | Taking down old unservicable cable of any size or type from any description (trenches, walls, ceilings., etc) from various locations, including any short length, all as specified & directed. |
| 47 | Supply and Laying jointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 70 Sqmm 3.5 core complete fixed to floor/walls/ceiling with suitable size of clamp/saddles complete all as specified and directed. |
| 48 | Supply and Laying jointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 50 Sqmm 3.5 core complete fixed to floor/walls/ceiling with suitable size of clamp/saddles complete all as specified and directed. |
| 49 | Supply and Laying jointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 95 Sqmm 3.5 core complete fixed to floor/walls/ceiling with suitable size of clamp/saddles complete all as specified and directed. |
| 50 | Excavation in trenches in soft/loose soil n. exc 1.5 Mtr wide and not exc. 1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed. |
| 51 | Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick complete all as specified and directed. |
| 52 | Removal of excavated material to a distance not exc 50 Meter and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed. |
| 53 | Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected |
| 54 | Supplying, laying sub class 'B' bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed. |
| 55 | Supply & Fixing in replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed |
| 56 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender