Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #56428674

Tender For Repair/Maint & Replacement Of Lt Ug Cables, Switch Gears, Oh Lines And Allied E/M Works At Af Stn Suratgarh

Issued by Statutory Bodies & Commissions/Committees · Ganganagar, Rajasthan
Tender Value
49 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
21 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint & Replacement Of Lt Ug Cables, Switch Gears, Oh Lines And Allied E/M Works At Af Stn Suratgarh

BOQ

Name of Work:- REPAIR/MAINT & REPLACEMENT OF LT UG CABLES, SWITCH GEARS, OH LINES AND ALLIED E/M WORKS AT AF STN SURATGARH
Sl. No. Item Description
1BOQ (REPAIR/MAINT & REPLACEMENT OF LT UG CABLES, SWITCH GEARS, OH LINES AND ALLIED E/M WORKS AT AF STN SURATGARH)
2Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables, erection of poles,struts, stays etc and getting out all as specified and as directed by Engr-In-Charge.
3All as per item Srl No 1 here-in-before but in PCC/floor/road
4All as per item Srl No 1 here-in-before but depth exceeding 1.5 metre and not exceeding 3 metre
5Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested, poles,stays,struts have been erected and tested complete all as specified.
6Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
7S&F for laying in replacement GI Tubing light grade 100 mm nominal bore for cable potection in road/floor all as specified and directed
8S&F for laying in replacement GI Pipe light grade 80mm nominal bore for cable protection in floor/road crossing/along pole complete all as specified and as directed.
9S&F for laying in replacement GI Pipe light grade 50mm bore for earth strip protection in floor/road crossing/along pole complete all as specified and as directed.
10S&F for laying in replacement HDPE Double Wall Corrugated pipe of size 63mm outer dia confirming to IS:16205 Part-24 including necessary pipe fittings such as couplers, end caps, bend etc. including fixed to wall/roof /pole/trench as required with suitable clamps for cable protection complete all as specified and directed.
11Supplying and laying of nominal size 90 mm dia (OD-90 mm) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205, Part 24 complete with fitting and cutting, jointing etc. direct in ground, complete as required.
12All as per Sr item 10 here in before but nominal size 40mm.
13Taking out from trenches/floors/road/wall/pipe/pole LT cable of any size/description and removing & reuse from site incl making good the disturbed surfaces to match with existing surface all as directed.
14Relaying/Labour only for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board at existing places or carrying to other location, upto 1100 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 35 sqmm 4 core cable obtained from item no-13 here-in-before shall be resued with required aluminium cable lugs.
15All as per item No. 13 here-in-before but 50 sqmm 3.5 core to 120 sqmm, 3.5 core complete all as specified and directed
16All as per item No. 13 here-in-before but 150 sqmm 3.5 core to 400 sqmm, 3.5 core complete all as specified and directed
17Supply & laying of LT UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 240 Sqmm 3.5 core as per IS 7098 (Part-I) laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. (Note: (i) Cable joint and excavation / earth work shall be measured and paid separately.)
18All as per item No. 16 here-in-before but 185 sqmm 3.5 core complete all as specified
19All as per item No. 16 above but of cross sectional area 150 Sqmm, 3.5 core.
20All as per item No. 16 above but of cross sectional area 120 Sqmm, 3.5 core.
21All as per item No. 16 above but of cross sectional area 95 Sqmm, 3.5 core.
22All as peritem No. 16 here-in-before but 70 sqmm 3.5 core complete all as specified
23All as per item No. 16 above but of cross sectional area 50 Sqmm, 3.5 core.
24All as peritem No. 16 above but of cross sectional area 35 Sqmm, 3.5 core.
25All as per item No. 16 above but of cross sectional area 25 Sqmm, 4 core.
26All as per item No. 16 above but of cross sectional area 16 Sqmm, 4 core.
27All as per item No. 16 here-in-before but 10 sqmm 4 core complete all as specified
28All as per item No. 16 here-in-before but 10sqmm 2 core complete all as specified
29All as per item No. 16 here-in-before but 16sqmm 2 core complete all as specified
30All as per sr item No. 16 here in before but 50 Sqmm 3 Core complete all as specified
31All as per sr item No. 16 here in before but 35 Sqmm 3 Core complete all as specified
32All as per sr item No. 16 here in before but 25 Sqmm 3 Core complete all as specified
33Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 10-16 sqmm, 4 core complete all as specified by Engr-in-Charge ,
34Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 25-50 sqmm, 4 core complete all as specified by Engr-in-Charge .
35Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 70-120 sqmm, 4 core complete all as specified by Engr-in-Charge ,
36Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 150 sqmm, 4 core complete all as specified by Engr-in-Charge .
37Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 240-300 sqmm, 4 core complete all as specified by Engr-in-Charge .
38Supply and fix Heat shrink straight through joint LT 1100 volts grade 10-16 sqmm, 4 core complete all as specified by Engr-in-Charge.
39Supply and fix Heat shrink straight through joint LT 1100 volts grade 25-50 sqmm, 4 core complete all as specified by Engr-in-Charge,
40Supply and fix Heat shrink straight through joint LT 1100 volts grade 70-120 sqmm, 4 core complete all as specified by Engr-in-Charge.
41Supply and fix Heat shrink straight through joint LT 1100 volts grade 150-185 sqmm, 4 core complete all as specified by Engr-in-Charge.
42Supply and fix Heat shrink straight through joint LT 1100 volts grade 240-300 sqmm, 4 core complete all as specified by Engr-in-Charge.Note for Srl item 32 to 41 :- Excavation & earth work shall be measured and paid separately.
43S&F as in replacement Cable route indicator showing \\"LT Cable\\" and route of cable with arrow made of CI in suitable eliptical/round shape and fixed on angle iron 40x40x6mm, 800mm long painted in Blue Colour with two coats of synthetic enamel paint cover a coat of red oxide primer duly embedded in PCC block (0.40x0.40x0.40)mtr below in ground and 0.15mtr above ground lable complete all as directed and specified.
44Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for working pressure 11000 Volts grade of HT line including taking down existing cracked/unserviceable pin type insulator complete all as specified and directed.
45Supply and fixing disc type insulators, porcelain vitreous white brown or green, 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamps for conductor having working pressure 11000 Volts including taking down existing cracked/unserviceable disc type insulator complete all as specified and directed.
46Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100mm height, 65mm dia for working pressure 1100 Volts grade of LT line including taking down existing cracked/unserviceable pin type insulator complete all as specified and directed.
47Supply and fixing Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator bolts, washers and nuts, as under 100mm height, 115 mm dia for working pressure 1100 Volts grade of LT line including taking down existing cracked/unserviceable pin type insulator complete all as specified and directed.
48S & F in replacement Loop type insulator, vitreous porcelain, white, brown or green: size with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed.
49M&L for earthing complete with GI earth plate 600x600x6mm thick electrode and 32x6 mm GI strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to GI strip earth lead by means of bolts, nuts, check , nuts and washers of galvanised iron or steel all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.(Note: GI strip beyond 7.5Mtr length from earth electrode shall be measured and paid separately).
50All as per item No 48 above but with 4 mm dia GI wire as earthing lead and GI protection pipe 20mm dia medium grade.
51M&L for earthing complete with copper earth plate 600x600x3.15mm thick electrode and 20x3 mm copper strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to copper strip earth lead by means of bolts, nuts, check , nuts and washers of copper all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.(Note : Copper strip & GI pipe 40mm dia beyond 7.5mtr length from earth plate shall be measured & paid separately under respective item)
52S&F GI earthing strip 32x6mm fixed to wall/pole/buried in ground /drawn in pipe complete as directed by Engr-In-Charge.
53S&F earthing strip 25x3.15 mm aluminium fixed to wall/pole/buried in ground /drawn in pipe complete.
54S&F GI wire 4mm dia iron fixed to wall/pole/buried in ground /drawn in pipe complete as directed by Engr-In-Charge.
55S & F Danger notice plate for HT poles size 1.6 mm thick mild steel sheet vitreous enemelled white letter figures and converntionl skull and bones maked in red colour with MS clamp of flate iron 25X3mm size, bolts, nuts, size of plate 25 X20 Cm complete all as directed by Engr-In-Charge.
56Dismantling U/S any size of cross arms from pole /structures/anti-climbing device etc complete all as specified and directed.
57M&L for MS work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer all as directed by Engr-In-Charge.
58M&L for anti climbing devices, spike type fabricated out of MS bars (Round, square and flat) including nuts, bolt, washers and welding in two halves made to shape to suit the cross section of the pole including painting etc complete all as specified and as directed.
59Cutting/trimming of tree branches around OH LT/HT electric line including cleaning upto 3.00 mtr horizontal distance on both sides of OH electric line including removing all creepers small bushes etc under OH line upto 60 mt each span complete all as specified and directed.
60M&L for stay assembly complete with MS stay plate 300x300x6mm thick galvanized stay rod not less than 16mm dia, 2.15 M long galvanized stay bow, galvanized thimble,stay clamp etc. all as shown in electrical plate No1of SSR part-I incl dismantling unsv one complete all as specified and directed. (Note:- Excavation,earthwork,cement concrete loop type insulators and stay wire shall be measured and paid separately under relevant items).
61M&L Galvanised stay strand, size 7/3.15mm incl dismantling unsv /taling down one complete all as specified and directed.
62Supply and fixing of Jumper for HT OH Lines with insulated with colour coding, (Red Green , Blue) with all conneted item i.e nut bolt, U G clamps etc up to length of size 3 to 5 Mtr of size 70 to 120 sqmm all as specified and directed by Engr -in-charge.
63Complete removal of old paint from the steel tubular pole of 7.5-9.0 mtr height above ground level without removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative white and black strips of 30 cm height each, including one coat of aluminium paint to the remaining part of pole (i.e above 1.50 mtr height) and its cross arms, bracing, support and all steel members complete all as specified and directed.
64Numbering of HT/LT poles serially with in printed type letter/number size width and height up to 40 mm as per directed by eng-in charge.
65Dismantling concrete poles/Struts/Steel pole of any size complete all as specified and directed.
66Supply and erecting in true vertical position steel tubular swaged pole, 9 metre long, type 410 SP-31 confirming to IS : 2713 including drilling of holes of required size and nuts for fixing of cross arms complete with mild steel base plate 6mm thick of size 300mm x 300mm, finial taper plug bolts, nuts, washers and screws,, painting with two coats of aluminium paint over a coat of red oxide and two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing complete all as specified and directed. (Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of BOQ.
67M& L for demolition of cement concrete / Cuting of road/floor/hard standing/tiles/walls/pole coping etc for laying of LT cables/pipes/earth lead with suitable mechanism complete all as sepecified and directed. Note: Cable, pipes and PCC for finishing / filling disturbed area will be measure and paid separetely under relevant item)
68PCC 1:4:8 (nominal mix) type D-2 using 40mm graded crushed stone aggregates, as in foundation, filling and mass concrete for poles and stay/installation paths complete all as specified and directed.
69PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate, as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating all as specified and directed.
70PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregates, as in foundation, filling and mass concrete for poles and stay/installation paths complete all as specified and directed.
71Dismantling ACSR or AAC conductor complete all as specified and directed.
72Supply and fixing aluminium conductor, steel reinforced (ACSR) of following sizes as in overhead conductor including fixing aluminium tapes for binding complete all as specified and directed: -(a) 6/1 x 3.0 - Ferret (b) 6/1 x 2.59 - Weasel (c) 6/1 x 2.11 - Squirrel Note: The weight of the conductor shall be determined as stipulated in Preamble (b) & (c) on Page 384 of SSR-2020 Part-II (Rates).
73M& L for Stringing of ACSR conductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge.
74M& L for Stringing of GI cradle Gaured conductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge.
75M&L for restraining of GI wire of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed
76M&L for replacement of earth pit chamber of size 300 x300 mm (internal dimensions) and 450x450mm(External) with PCC 1:3:6 type C-1 , RCC 1:2:4 type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick with 12 mm dia MS hook of suitable size and shape for lifting and MS angle iron frame 50 x 50 x 4 mm including GI funnel with wiremesh complete all as specified.
77Cutting and uprooting grass, vegetation shrubs, bushwood undergrowth, roots and trees not exceeding 30 cm girth (measure one metre above ground level) in and around electrical sub stations, two/four pole structures and removing rubbish to a distance upto 50 metres outside the periphery of the area, complete all as specified and as directed by Engr-in-Charge.
78Supply and fixing of synthetic insulating mat suitable for 11 KV installation of size 1.00 m x 2.00 m and 25mm thick (ISI marked) complete all as specified and directed.
79Supply and fixing Aluminium thimble/lugs suitable for 35 sqmm to 95 sqmm XLPE cable all as specified and directed.
80Supply and fixing Aluminium thimble/lugs suitable for 120 sqmm to 185 sqmm XLPE cable all as specified and directed.
81Supply and fix in replacement of MCCB 630 Amp rating,4-pole 415V, breaking capacity 50 KA, Adjustable & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
82Supply and fix in replacement of MCCB 400Amp rating,4-pole 415V, breaking capacity 36 KA, Adjustable & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
83Supply and fix in replacement of MCCB 320 Amp rating,4-pole 415V, breaking capacity 36 KA, Adjustable & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
84Supply and fix in replacement of MCCB 250Amp rating,4-pole 415V, breaking capacity 36KA, Adjustable thermal & fixed magnetic setting type Ics 100% of Icuall as specified and directed.
85Supply and fix in replacement of MCCB 200Amp rating,4-pole 415V, breaking capacity 36KA, Adjustable thermal & fixed magnetic setting type Ics 100% of Icuall as specified and directed.
86Supply and fix in replacement of MCCB 160Amp rating,4-pole 415V, breaking capacity 36 KA, Adjustable thermal & fixed magnetic setting type Ics 75% of Icu all as specified and directed.
87Supply and fix in replacement of MCCB 125 Amp rating,4-pole 415V, breaking capacity 10 KA, Adjustable thermal & fixed magnetic setting type all as specified and directed.
88Supply and fix in replacement of MCCB 100 Amp rating,4-pole 415V, breaking capacity 10 KA, Adjustable thermal & fixed magnetic setting type all as specified and directed.
89Supply and fix in replacement of MCCB 320 Amp to 400 Amp rating,3-pole 415V, breaking capacity 36 KA, Adjustable thermal & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
90Supply and fix in replacement of MCCB 250Amp rating,3-pole 415V, breaking capacity 36KA. Adjustable thermal & fixed magnetic type setting Ics 100% of Icuall as specified and directed.
91Supply and fix in replacement of MCCB 200 Amp rating,3-pole 415V, breaking capacity 36KA. Adjustable & fixed magnetic type setting Ics 100% of Icuall as specified and directed.
92Supply and fix in replacement of MCCB 160 Amp rating,3-pole 415V, breaking capacity 36 KA, Adjustable & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
93Supply and fix in replacement of MCCB 125 Amp rating,3-pole 415V, breaking capacity 10 KA, Adjustable magnetic & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
94Supply and fix in replacement of MCCB 40 to 100 amp Amp rating,3-pole 415V, breaking capacity 10 KA, Adjustable magnetic & fixed magnetic setting type Ics 100% of Icu all as specified and directed.
95Labour for disconnecting LT cable of any size from structure/pole/transformer for finding fault, M&L for defect rectification LT cable laid in trenches or any location by locating fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engr-in-charge.Note: joint kit will be measured seperately in appropriate item in this schedule
96Labour only for disconnecting LT cable of any size from pole (height 7.5 to 9 mtr) /transformer/panel and re-connecting of cable at both end after removing carbon /burnt insulation part of cable by cutting refixing cable with new cable lugs . Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 06 hours after notification, failing to which Rs 500/- per day will be recoverd per complaint.
97Labour only for disconnecting LT cable from Junction Box of pole /TPN DB and removing cable loop by exacavtion and re-connecting of cable of any size from both end after removing carbon /burnt insulation part of cable by cutting refixing cable with new cable lugs including returning , filling including levelling of soil complete all as specified by Engr-in-Charge.
98S&F in replacement service cable 16 Sqmm 2 core 1100 volts grade heavy duty PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit all as required or directed.
99Supply and fixing for Display Board for electric shock treatment chart/ Maintenance Chart/ Description Chart/Do's and Don't chart of size 850x600 mm made out of CRCA sheet 2 mm thick with square pipe 35 mmx35 mm fixed around sheet by welding and making hanging arrangements on top of the board. Board shall be painted with two coats of stove enamelled paint (navy Blue) over a coat of red oxide primer and writing the detail with fluoroscent reflective tape (as per sample) by digital computerized printing style complete all as specified and as directed.
100M&L for excavation in post holes soft/loose soils ( for similar holes each not exc 0.5 cum getting out returning , fillling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm.
101Supply & fixing bus bar chamber 100 Amps 8 way of suitable size with 4 strips 100 Amps bus bar aluminium with suiatble space for incoming and outgoing. Bus bar fixed on insulators in zig-zag position, all as specified and directed.
102M&L for repair to street panel board indoor / outdoor type of any capacity having Incomming & out going MCCB , MCBs, timer switch and power contactor by carrying out the following works:-(i) Cleaning incomer switches, bus bar & out going switches etc thoroughly. (ii) Replacement of rusted bolts & nuts, screws, thimble etc as per existing.(iii) Making the locking arrangement functional including welding if required(iv) making proper connections for out going / incoming cable by providing suitable thimble as required.
103Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine or manually without damage nearby electric cable, water pipe line etc including HDPE pipe of 80 mm dia and sealing the end of pipe complete all as specified and directed.
104Servicing of Air Circuit Breaker (ACB) rating 800 Amp to 1250 Amp installed in LT /HT Panel including isolation, dismantling, internal cleaning, checking of main and arcing contacts, tightening of all power and control connections, lubrication of moving parts, checking of spring charging mechanism, testing of closing/tripping operation, checking/calibration of protection relay settings, insulation resistance testing, re-fixing,commissioning and complete functional testing as directed by Engineer-in-Charge.Note: minor repair and calibration rate including in item.
105Supply and fixing PVC moulded LT Line separator suitable for 4 lines OH system. Make- Denson/Mex-well/JB/Jaipuriya brothers
106Supply and installation, testing, commissioning Outdoor type feeder piller Box factory made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made CPRI Approved & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly powder coated inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel grey paint including taking out existing panel complete all as specifed and directed and consisting of the following equipments:-(i) MCCB, 4 pole , 35/36 KA , 250 Amps -01 Nos ( Incomming)(ii) MCCB, 4 pole , 35/36 KA , 200 Amps -01 Nos (Out going) (iii) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv)(viii) Solid aluminium bus bar 400 Amp for 3 phase and neutral 8 way (ix) PCC and Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge Note :- (i) Earth work, 1:2:4 PCC work for foundation and MS works shall be included in the unit qouted rate . (ii) Cable gland of brass for different size of cable as per requirement for incoming and outgoing cable (iii) The contractor shall get the drawings approved by the accepting officer before placing the orders.
107Supply and installation, testing, commissioning Outdoor type feeder piller Box factory made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made CPRI Approved & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly powder coated inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel grey paint including taking out existing panel complete all as specifed and directed and consisting of the following equipments:-(i) MCCB, 4 pole , 35/36 KA , 160 Amps -01 Nos ( Incomming)(ii) MCCB, 4 pole , 16 KA , 125 Amps -01 Nos (Out going) (iii) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv)(viii) Solid aluminium bus bar 200 Amp for 3 phase and 150 amp for neutral 8 way (ix) PCC and Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge Note :- (i) Earth work, 1:2:4 PCC work for foundation and MS works shall be included in the unit qouted rate . (ii) Cable gland of brass for different size of cable as per requirement for incoming and outgoing cable (iii) The contractor shall get the drawings approved by the accepting officer before placing the orders.
108M & L for preperation of old painted surfaces of LT panel /AMF panel and applying two coat of blue/Gray enamel paint and writing with white enamel paint Danger symbol of size as directed complete all as specified and as directed.
109M & L for preperation of old painted surfaces of Feeder piller/ busbar panel and applying two coat of blue/Gray enamel paint and writing with white enamel paint , of size as directed danger symbol complete all as specified and as directed.
110S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk),forming holes of Fe 410-W (Gde E- 250) quality without any attachmen use for cable duct cover at substn complete all as directed.
111Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary of tender documents. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56428674
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint & Replacement Of Lt Ug Cables, Switch Gears, Oh Lines And Allied E/M Works At Af Stn Suratgarh
Basic Detail
Tender No 8355/E8
Bidding Type Tender
Location
City Ganganagar
State Rajasthan
Key Dates
Publish Date 11 Jul 2026
Submission Date 05 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Available
Document List
BOQ_871370.xls
fea285e7-d074-4cca-a45e-d1adaa3e7ec5.html
Tenderdocuments8355.pdf
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_871370.xls

html

fea285e7-d074-4cca-a45e-d1adaa3e7ec5.html

pdf

Tenderdocuments8355.pdf

pdf

Tendernotice_1 (6).pdf

Disclaimer