Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #56428651

Tender For Addition Alteration Of Afnet Eqpt Room At Er-I, Er-Ii, Cuas Section And Jammer Section And Provn Of Green Energy Efficient Street Lights At Certain Locations At 8Fbsu

Issued by Statutory Bodies & Commissions/Committees · udhampur, Jammu and Kashmir
Tender Value
48.53 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
17 days left
EMD
97100
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
udhampur → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Addition Alteration Of Afnet Eqpt Room At Er-I, Er-Ii, Cuas Section And Jammer Section And Provn Of Green Energy Efficient Street Lights At Certain Locations At 8Fbsu

BOQ

Name of Work:- ADDN/ ALTN OF AFNET EQPT ROOM AT ER-I, ER-II, CUAS SECTION AND JAMMER SECTION AND PROVN OF GREEN ENERGY EFFICIENT STREET LIGHTS AT CERTAIN LOCATIONS AT 8FBSU
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (AF), 8FBSU,AF Name of Work: ADDN/ ALTN OF AFNET EQPT ROOM AT ER-I, ER-II, CUAS SECTION AND JAMMER SECTION AND PROVN OF GREEN ENERGY EFFICIENT STREET LIGHTS AT CERTAIN LOCATIONS AT 8FBSU Contract No: GE (AF) AWA-26/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. DESCRIPTION OF ITEMS Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2B/R PORTION
3Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm, deep and getting out in soft/loose soil, complete all as specified and directed.
4Excavation in trenches n.exc. 1.5 m wide and n.exc 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc. 10 Sqm on plan and n.exc 1.5 m in depth and getting out in getting out in soft / loose soil all as directed.
5M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundation, filling & mass concrete, all as specified and directed.
6S&F for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, all as specified and directed.
7S&F for TMT bars 6 mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, all as specified and directed.
8M&L for formwork to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, etc. also splays between floors and beams, etc. rough finish surface of concrete flat all as specified and directed.
9Returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm all complete as specified in soil.
10Removing excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point all as directed.
11Dismantling of plain or corrugated steel sheeting of any gauge, thickness etc in roof coverings/ cladding/ eave etc, complete all as specified.
12Excavating in post holes (or similar holes) in any type of soil each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete.
13M&L cement concrete in foundation filling and mass concrete type D2 1:4:8 (using 40mm graded crushed stone aggregate) in post holes all as specified.
14S&F Roof trusses (framed), trussed, posts, struts, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, base plate and gusset plates etc confirming to Fe 410-W (Gde-E-250) quality-A, complete all as specified and directed.
15S&F galvanised corrugated mild steel sheeting, with two corrugation side lap fixed with 'L' type or 'J' type or cranked hooked bolts with washers in roof, 0.63 mm thick, grade-O quality, with 120 Grms/ Sqm zinc coating and grade 'B' Class 8, complete all as specified and directed by Engineer-in-Charge.
16S&F Galvanised plain mild steel sheeting 0.63 mm thickness fixed with 'L' type or 'J' or cranked hook bolts with washers, in roofs as in ridge etc, all as specified and directed.
17S&F frame work such as grills, gratings etc with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bar; iron doors; ladders; framework of water tanks, framed portion and hung as gates, including pintle hinges, stops, hand made sliding bolts etc. and similar confirming to Fe-290 Gde E-165.
18S&F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, as specified, erected in position and securing runners with hold fasts and brackets, complete all as specified and directed by Engr-in-Charge.
19Taking down (Steel/ Wooden) chowkhats of frames of any description n.exc 1.50 Sqm with shutters (without taking off shutters from the frames) and making good disturbed portion, complete all as specified and directed.
20All as per Srl Item No. 18.00 here-in-before, but exceeding 1.5 Sqm and n.exc 4 Sqm with shutters (without taking off shutters from the frames) and making good disturbed portion, complete all as specified and directed.
21Taking down shutters of any description area exc 2.00 Sqm each, all as specified & directed.
22S&F Anodised aluminium frame for doors, windows and ventilator with one or more rebates including joining cleat for fixing etc. complete all as specified.
23S&F anodised aluminium door shutters, aluminium section weighing 1.10 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
24Anodised aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing of 0.55 Kg/RM including fixed with aluminum beading, silicon lining and gaskets, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc, complete all as specified and directed
25M&L for 12 mm prelaminated particle board both side decorative, fixed with aluminium beading and rubber neoprene packing to aluminium frame, complete all as specified.
26M&L for 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane including hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/ spring clips, complete all as specified and directed.
27M&L for 4.0 mm thick sheet glass, figured tinted and glazing with oil putty in square n.exc 0.5 Sqm in each pane including hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/ spring clips, complete all as specified and directed.
28S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete.
29Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing the rubbish of the premises complete.
30M&L 25mm PCC 1:2:4 Type B-0 (Using 12:5 mm graded crushed stone aggregate) as in sub base floor, complete all as directed and specified .
31M&L coloured/printed non skid ceramic tiles 7 mm thick (square/rectangular) area of each tile exc 0.11 but not exc 0.16 Sqm laid in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15 mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement, complete all specified and directed.
32M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/shade) of 450x300x7 mm / 350x250x7 mm / 450x350x7 mm thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, over and including 10 mm thick rendering in cement mortar 1:4 rough finish to receive the tiles, complete all as specified and directed.
33M&L coloured/ printed ceramic tiles 7 to 8 mm thick area of each tiles exc 0.18 Sqm but not exc 0.38 Sqm, laid in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15 mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement, complete all as specified and directed by Engineer-in-Charge.
34-Ditto- but on vertical surfaces such as skirting including 9 to10 mm thick rendering in cement mortar 1:3 rough finish to receive the tiles, complete all as specified and directed.
35Framed work as in false ceiling, doors or gates of angle or other section with gusset plates, rails, braces, etc. complete drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410 A-quality grade, all as specified and directed.
36Prelaminated particle board 12 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination as in false ceiling fixed to mild steel/ timber frame, complete all as specified.
37Demolition of cement concrete to ground floor (unreinforced) and paving n.exc 15 Cm thickness (below or above ground level) and removing rubbish of out side MOD land, complete all as specified and directed.
38M&L 100 mm thick for cement concrete 1:4:8 type D-2 (40 mm graded crushed stone aggregate) as in sub base of flooring, complete all as specified and directed.
39S&F for 60 mm thickness machine pressed precast concrete interlocking paver block with grey cement and no pigment, shape and size confirming to IS 15658-2006 M-35 grade over completed all as specified and directed.
40Supply only fine aggregate (sand) for sand cushioning as in bed complete all as specified & directed.
41M & L 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in plinth protection even and smooth without using extra cement complete all as specified and directed.
42M&L 75 mm thick cement concrete 1:2:4 Type B-2 (using 40mm graded crushed stone aggregate) as in sub base of flooring, complete all as specified and directed.
43M&L for 150 mm thick PCC (1:1.5:3) nominal mix type A2 using 40 mm graded crushed stone aggregate mass concrete as in hard standing etc, complete all as specified and directed.
44Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed
45M&L Brick work with sub class B bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
46Taking down cement plaster, any description on brick walls or on concrete surfaces including raking out joints, hacking for key, scrubbing down with water, etc, and removing same from the site(s), complete all as specified and as directed.
47M&L for rendering 10 mm thick on fair faces of concrete/ brick interior surfaces in cement mortar 1:6 as per manufacturer's instruction, finished fair and even without using extra cement, complete all as specified and directed.
48M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces on ceiling finished even and smooth without using extra cement complete all as specified.
49M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 on wall surfaces, finishing the surface even and smooth without using extra cement, complete all as specified. (Note:- Integral water proofing compound shall be measured and paid for separately).
50Supply only Liquid water proofing compound ISI Marked (used 200 ml per bag of cement), complete all as specified and directed.
51M&L preparation of newly plastered wall surface and applying of Birla/JK white wall putty approx 3 mm thick in two layer as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers and applying two coats of oil emulsion distemper over a coat of primer, complete all as specified and directed.
52Preparing new plastered or un-plastered surfaces of walls and applying two coats Acrylic exterior emulsion paint in camouflaging (Disruptive) pattern (Green, Grey & Brown colour) over a coat of acrylic primer complete all as specified and directed.
53M&L for preparation of newly plastered ceiling surface and applying of Birla/JK white wall putty approx 3 mm thick in two layer as per manufacturer's instruction on new surface and make the surface smooth by rubbing with sand papers and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed.
54Preparation of old painted surfaces of steel or iron work or CGI/ PGI sheeting in walls or roofing, over 10 Cm width or girth, not otherwise described and applying one coat of synthetic enamel paint in camouflaging (Disruptive) pattern in three colours (Green, grey and brown), complete all as specified and directed.
55Preparation of new surfaces of steel or iron work or CGI/ PGI sheeting in walls or roofing, over 10 Cm width or girth, not otherwise described and applying two coat of synthetic enamel paint in camouflaging (Disruptive) pattern in three colours (Green, grey and brown) over a coat of acrylic primer complete all as specified and directed.
56M&L for preparing of new or previous untreated steel surfaces over 10 Cm width or girth and making good including primer and make the surface smooth by rubbing with sand papers etc and applying two coat of synthetic enamel paint, complete all as specified and directed.
57S&F for solid PVC door frame of size 50mmx47mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube supply and fixing as specification and drawing.
58S&F of factory Made Solid panel PVC door shutter, 28 to 30mm thick (stiles) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded and wood grain printed PVC sheet used instead of plain colour PVC sheet & 5mm thick x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900) used instead of exposed portion of PVC sheet beading plain colour PVC sheets for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying and fixing in the frame at site as per specification & drawing.
59S&F butt hinges, (ISI Marked), aluminium alloy with galvanised mild steel, of size 100mm long all as specified & directed.
60S&F extruded aluminum alloy handles of size 100 mm fabricated type anodised complete.
61S&F Aluminium alloy anodised barrel tower bolts of extruded section 150 mm long and fixed complete.
62S&F in repair Vitreous China wash down water closet (pedestal pattern), White/coloured including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC coloured seat cover and chromium plated jet including PVC connection, fixed complete including demolition of old unserviceable WC and provision of plain cement concrete M-15, type B-I, using 20mm graded crushed stone aggregate, fixed in repairs complete all as specified and directed.
63S&F in repair PVC flushing cistern 10 Ltr capacity white with all internal fittings including brackets PVC connection 45 Cm long including nut and PVC washer at both ends including 32 mm bore PVC long bend flush pipe 90 Cm long, complete all as specified and directed.
64S&F CP health faucet of 1.25 Mtr long CP flexible tube with necessary fittings, complete all as specified and directed.
65S & F in repairs Vitreous china wash hand basin coloured, flat back type of size 550mm x 400mm including waste pipe & plug, porcelain stopper, 32 mm dia PVC waste pipe with CP brass coupling and set of bracket, complete all as specified and directed.
66S&F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed.
67S&F Towel ring of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats, complete all as specified and directed.
68S&F Vitreous China urinals of minimum size 580x380x350 mm, crystal white, Half Stall Urinal, with 32 mm bore waste fittings, brass, chromium plated with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including spreader, 60 mm long brass screws, pointing around urinal back in cement with brackets, flush pipe, trap, grating and union for discharge pipe (Including fixing supply pipe to flushing cistern, trap and waste pipe), complete all as specified and directed.
69S&F 15 mm bore CP Pillar tap cast copper alloy with capston heads screwed down for high press with or without lattered hot or cold with long screwed shank and fly nuts screwed for iron pipe, complete as specified
70S&F in repairs stainless steel wall mount case with Soap Dish & Bruch Holder fixed to wall all as specified and directed by Engr-in-Charge .
71S&F in repairs Corner Glass Shelf of size 320 x 320 mm with Silver chromium finished border oval range premium quality all as specified and directed by Engr-in-Charge .
72Taking up or down 15 mm dia steel tubing in wall, ceiling or floor and connections, including cleaning for refixing or removal to store etc complete.
73S&F 15 mm dia medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors.
74S&F in repairs CP grating round suitable for 110 mm dia and connecting up, fixed in repairs.
75M&L PVC (SWR) floor trap 110 mm dia including jointing with solvent cement complete.
76S&F PVC (SWR) pipes single socketed, 75mm bore, in any length with rubber ring joints fixed to wall and floor, complete all as specified and directed.
77PVC (SWR) 75mm bore (dia), bends, any radius with access door and jointing with solvent cement and fixed-in-repairs, complete all as specified and as directed.
78S&F in repair 15 mm dia 450 mm long PVC connection with brass nut and washer, complete all as specified and directed.
79S&F in repair stop valve/angle valve, fancy type, chromium plated, cast copper alloy screwed down, high pressure, with crutch or butterfly handle of 15 mm dia. Screwed both ends for iron pipe or for unions and fixed, all as specified & directed.
80M&L for moorum/ red bajri filling in floors or pavings, laid in layers n.exc 15 Cm thick, spread , levelled and rammed including watering, complete all as specified and directed.
81M&L hardcore using broken stone boulders not exceeding 63 mm deposited spread and levelled in layers not exceeding 15 Cm thick watered and rammed to a true surfaces, complete all as specified & directed.
82S&F 3 mm thick mild steel plain or chequered plates fixed with hinges in equal angle frame as openable including handle, in available size of FE 410-W (Gde-E-250) quality-A, complete all as specified and directed by Engineer-in-Charge.
83Dismantling of old structure steel work including doors, gates but excluding framed truss etc, complete all as specified and directed by Engineer-in-Charge.
84E/M PORTION
85Taking down carefully unserviceable copper/ aluminium point wiring (light, fan, socket, power or AC,s) complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, including taking down of DB’s, meter board any type all as specified and as directed.
86Taking down carefully submain wiring complete including fixture and fitting such as DBs, wooden terminal boxes any type, all as specified and as directed.
87Point wiring for one light point/ fan point controlled by one switch with 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 Sqmm FRLSH with insulated unsheathed copper conductor single core cable (green colour) as earth lead in and including concealed/casing caping in wall/ceiling with rigid PVC conduit medium grade with all fittings (ISI marked ) controlled by one switch including CI/MS sunk box of required size including base plate and switch cover etc, complete all as specified and directed by Engr-in-Charge, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification complete.
88(a) One light point controlled by one switch.
89(b) One wall fan/Exhaust fan/ceiling fan point controlled by one switch.
90(c) One 3 pin socket outlet point 5 Amps on independent, with cables 1.5 Sqmm size .
91(d) One 3 pin socket outlet point 5 Amps on the same board with other switches.
92(e) One 3 pin socket outlet point 15 Amps on independent, with cables 2.5 Sqmm size .
93M&L all as per item No-86.00 above but for one 3 pin socket outlet 16 Amps on independent board with the cable 4.0 Sqmm and 4 Sqmm FRLS PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead medium grade with all fittings (ISI marked) for installation of ACs all as specified and directed by Engineer-in-charge.
94Supply and fixing for energy saving environmental friendly, LED tubelight fittings 20 Watts 4 Ft (Aluminium body) long life, impact proof, surface/wall mounting IP 20 LEDs including PVC square block 02 Nos complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size with ceiling rose, complete all as specified and directed.
95S&F in 5 pin single socket outlet 2 in 1, 5 pin, 5 Amps flush type including taking down old unserviceable one.
96S&F in 5 pin switch socket combination 2 in 1, 5 Amps flush type including taking down old unserviceable one.
97S&F switch socket combination outlet flush type 16A 2/3 pin combined, complete all as specified and directed.
98S&F Switch piano flush type one way 06 Amps, complete all as specified and directed.
99S&F ceiling rose surface bakelite 3 terminals, complete all as specified and as directed by Engineer-in-Charge.
100Supply and fixing GI Bracket bent to shape fabricated with GI Pipe 40 mm dia light grade 1.5 m long including mounting clamps nut bolts complete all as specified and directed.
101Supply and fixing of building security light with pressure die cast housing and toughened glass and individual LEDs with secondary lens optics for building outside application with system wattage of 25W 230V AC outdoor type with a nominal efficiency. The housing should be of non corrosive high-pressure die-cast aluminum, complete all as specified and as directed.
102M&L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 06 Sqmm and drawing through & including non-metallic PVC conduit concealed/ casing caping on walls/ ceiling including earth continuity conductor of size 06 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in concealed PVC casing caping including connecting to main board, complete all as specified and directed by Engineer-in-Charge.
103Supply and fixing of Exhaust Fan single phase 230Volts, 250mm sweep 1200 RPM in plastic body, including louvers with all connected accessories including making opening for fitting of exhaust fan by breaking wall and making good to the disturbed surface as required, complete as specified and directed.
104Supply and fix electric water heater instant Geyser of capacity 25 liter, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc, complete all as specified and as directed.
105S&F MCB protected socket PVC plastic base model with socket plug top and 32 Amp MCB SP 240 Volts enclosures with two pin and earth plug and socket, complete all as specified and directed by Engineer-in-Charge.
106Shifting of Split type AC/ Window type AC capacity upto 2 Ton from old position and refixing to new position including drilling, cutting, chasing and making good on existing surface of PCC concreting, white cement plastering and all necessary items including transporting of ACs from one location to other location in station and handing over the machine/ equipment in serviceable condition to the user including fixing to new location, all as specified and directed by Engineer-in-Charge.
107S&F copper pipe 5/8\\" complete all as specified and directed by Engineer-in-charge.
108S&F copper pipe 1/4\\" and removing old u/s copper pipe complete all as specified and directed by Engineer-in-Charge.
109Taking down existing Exhaust Fan/ Ceiling Fan/Wall Fan any size with due care and handing over to MES Store all as required and directed.
110S&F MCB Distribution board, single pole & neutral 240 Volt, 8 way, type with 200 Amps bus bar, complete all as specified and directed.
111S&F MCB Distribution board, Single pole & neutral 240 Volt, 6 way, type with 200 Amps bus bar, complete all as specified and directed.
112S&F MCB Distribution board, Single pole & neutral 240 Volt, 12 way, type with 200 Amps bus bar, complete all as specified and directed.
113S&F in replacement of factory made load line vertical TPN DB 04 way double door made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 4 way TPN 415 volts, vertical type, wall /surface mounting with suitable busbar, neutral link & earth link suitable for MCCB as incomer & MCB SP/TP as out going (04 Nos 3 phase outgoing and 04 Nos single phase outgoing) complete with & including one No MCCB 100 Amps 4 pole 25 kA fixed type for incoming and 04 Nos 40-63 Amp SPN as outgoing complete all as specified.
114Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB, complete with connection testing and commissioning.
115(a) SP 5 to 32 AMP
116(b) SPN 40 to 63 AMP
117Supply and fixing 36 Watts recess /surface mounting LED flat panel 2' X 2' made of extruded aluminium frame with high LEDs & glare free opal diffuser IP20, all as required at site and as specified and directed by Engineer-in-Charge.
118Taking down existing TPN DB onload changeover switch and connected electric fittings from inside of building to outside with due care and refixing with new lock bolt (where required) after cleaning/painting if required including connecting electrically using cables and restore all connections as required at site all as specified and directed by Engineer-in-Charge.
119Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in the ground vertically to a depth not less than 2.25 mtr deep below the normal ground level with top edge of the earth plate not less than 1.5 metre below the normal ground level connected to GI earth lead wire 4.0 Sqmm of size by means of bolts, nuts and washers protected by GI tubing light grade pipe of 15 mm bore including provision of concrete pit in PCC 1:2:4 type B-I using 20 mm graded crushed stone aggregate with 40 mm thick RCC cover slab (1:2:4) reinforced with XPM weight type not less than 4Kg /Sqm and 6 mm dia round bar handle excavation and earth work in any type of soil, charcoal dust and salt light grade GI protection pipe 15 mm and GI wire upto main earthing of pole complete all as shown in electrical plate No-03 of MES Sch 2009 Part-I all as specified and directed.(Note: Upto 7.5 mtr length of pipe of 15 mm bore GI tubing and GI wire shall be deemed to be included in unit rate quoted by tenderer.)
120Supply install, commissioning and testing LT panel outdoor type, both side openable, cubical type, double door, floor mounted, made out of 3.15mm thick MS sheet duly powder coated complete with aluminium bus bar 200 Amps rating mounted on epoxy based post insulators duly drilled holes for connections, all as specified including necessary foundation grouted in PCC 1:2:4 for mounting the panel suitable for 415 Volts, 50 C/s 3 phase and neutral system and internal wiring with suitable size of PVC insulated copper cable, copper lugs comprising of following accessories:- (a) MCCB 4 pole 415 V 125 Amps with 16 KA for incoming.(b) Outgoing MCCB 63 Amp 16 KA-04 Nos.(c) Outgoing SPN 32-40 Amp-02 Nos(d) Digital multimeter (Type ELF 3200 series) with suitable CT ratio.(Stand of Panel should be such that panel be 45 cm above the ground level and 30 cm below ground. Cost of stand, earth work and installation be included in deemed rate.
121Supply installation commissioning and testing of Busbar chamber 6 way 63 Amps indoor cubical floor mounted type made out of 2 mm thick MS sheet duly powder coated complete with bus bar 200 Amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 Phase 4 wire 415 Volts 50 Hz power supply system with locking arrangement for front / rear door complete all as specified and as directed.
122Supply, laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 25 Sqmm, 4 core including making electrical connection with thimbles, complete all as specified and directed.
123Supply, laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 16 Sqmm, 4 core including making electrical connection with thimbles, complete all as specified and directed.
124Supply and laying of DWC (Double wall corrugated) pipe, ISI marked, having outer dia as 63 mm and inner dia as 50 mm for non pressure under ground cable including all connected accessories/ fittings such as coupler, 'O' ring and suitable Nos of clamp to fix with wall/ roof/ ceiling if required at site etc. for protection of cable, complete all as specified and directed by Engr-in-Charge.
125Supply and installation of advance maintance free single rod earthing system by boring the required Nos of holes of dimension 8 to 10 inch wide and length of hole should be less than approximately 2 inches of the electrode length in semi hard soil or hard soil consisting of one Nos UL 467 listed CPRI tested Pure copper tube earth electrode designed in accordance to IS:3043(1987).The system consists of copper tube earth electrode having purity of 99.99%.There is a copper strip inside it which is pressure filled with highly conductive crystalline mixture of metal alloys and other conductive material. Both the ends of the electrode should be permanently sealed with the extended terminal having two holes at the top for connecting the earthing system to the equipment/load. The Copper tube earth electrode should be of outer dia 50 mm, thickness of rod 01 mm and length 03 Mtrs tested according to IEC 62561-2 including min 25 Kgs/electrode of earth enhancing compound (PROCEM) NABL certified enhancing compound should have restivity less than 50 Ohm-meter with chemically inert to sub soil that should not pollute the environment and non corrosive to the earth electrode itself. Provision of the connector for connecting electrode with earthing conductor/strip including fastener having suitable size according to the electrode and earthing conductor dimensions.Note:-copper strip of 7.5m length from earthing electrode to the test point is included in the quoted rate. The Earth pit inspection chamber should be as per IEC 62561-5 or latest and will be of 300x300x300 mm inside dimension of RCC with 50 mm thick and fine finish.
126M&L for Test point terminal block for earthing made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw, complete as specified and directed.
127Supplying and laying GI tubing light grade fixed to the wall/ground of size 50 mm bore for cable protection complete all as specified and directed.
128S&F Electrostatic discharge mat of dimension 2 ft x 4 ft and 2mm thick with 4-corner snap buttons, wristbands and grounding cords, complete all as specified and directed by Engineer-in-Charge.
129Supply & Fix single pointed Copper air termination rod, 12 mm dia, 300 mm long all as specified and directed.
130S & F Copper strip 20 X 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed.
131Earthing complete with Copper earth plate 60cmx60cmx 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip 20x3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. Earthing of machinery/ equipment Installed using 20 x 3 mm copper strip and copper plate of size 600 x 600 x 3.15 mm, as earth electrode, complete all as specified and directed by Engineer-in-Charge.
132S&F GI Pipe light grade 40 mm bore laid on floor for mounting air termination rod with suitable PCC work for erection of Lightening Arrestor, fixed to Wall/ceiling/roof etc, with all fittings, all as specified and directed.
133Supply, laying or passing through pipe, underground cable XLPE insulated, armoured and PVC sheathed LT 1100 volts grade with aluminum conductor of size 6 Sqmm, 2 core including making electrical connection, complete all as specified.
134Supply and fixing Green energy efficient street light 40W hybrid mode operation with 4 KV +10 KV SPD, Luminenance efficacy per watt>150 lm/W, with battery back up to 24 hrs with dimming with average life 50,000 hours, opening temp -10 degree C to 50 degree C dust proof, Aluminium housing, Battery charging protection with inbuilt protection. Battery : deep discharge, over voltage reverse polarity, capacity of battery should be such to meet 24 Hrs autonomy. Charging time not more than 1 day. Solar panel should be made up of high grade mono crystalline silicon cell with high efficiency and have special dust repellent coating on solar panel surface to prevent dust accumulation.
135Supply and fixing hot dip galavanised octagonal poles 6 Mtr height with suitable bracket, nut bolt etc for fixing Solar street lights, complete all as specified and as directed by Engineer-in-Charge.Note: Rate quoted including the necessary civil work for fixing the poles.
136M&L for DWC (Double Wall Corrugated) Duct Pipe as per IS code IS-16205 (Electrical cable use) size (Outer dia 40 mm and inner dia 32 mm), complete all as specified and as directed by Engineer-in-Charge.
137Note:- An amount of Rs. 7025.32 on account of credit schedule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56428651
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.53 Lakhs
LAST DATE 01-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Addition Alteration Of Afnet Eqpt Room At Er-I, Er-Ii, Cuas Section And Jammer Section And Provn Of Green Energy Efficient Street Lights At Certain Locations At 8Fbsu
Basic Detail
Tender No GE (AF) AWA-26/2026-27
Bidding Type Tender
Location
City udhampur
State Jammu and Kashmir
Key Dates
Publish Date 11 Jul 2026
Submission Date 01 Aug 2026
Open Date 03 Aug 2026
Finance
Tender Value 48.53 Lakhs
Tender Fee 500
EMD 97100
Exemption Available
Document List
0ce65f1e-c13e-4ec9-9857-cb6bb28b1e11.html
BOQ_871333.xls
Tender26.pdf
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

0ce65f1e-c13e-4ec9-9857-cb6bb28b1e11.html

xls

BOQ_871333.xls

pdf

Tender26.pdf

pdf

Tendernotice_1 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders