Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #56428608

Tender For special Repair To Bldg No P-8A (Bde Office) And T-41 (Sand Model Room) At Jalapahar Under Age (I) Darjeeling.

Issued by Statutory Bodies & Commissions/Committees · Gangtok, sikkim
Tender Value
38.82 Lakhs
Estimated cost
Bid Submission
04 Aug 2026
12 days left
EMD
77700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gangtok → sikkim
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Bldg No P-8A (Bde Office) And T-41 (Sand Model Room) At Jalapahar Under Age (I) Darjeeling.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Jul-2026 BOQ Corrigendum BOQ 04-Aug-2026

BOQ

Name of Work:- SPL REPAIR TO BLDG NO P-8A (BDE OFFICE) AND T-41 (SAND MODEL ROOM) AT JALAPAHAR UNDER AGE (I) DARJEELING.
Sl. No. Item Description
1Taking down cement plaster of any description including racking out joints complete all as specified and directed.
2M&L for rendering 15mm (10mm+5mm) thick in cement mortar 1:4 on fair faces of brick work or concrete surface (Externally) including finishing even and smoothwith integral water proofing compound @ 3% by weight of cement or in the manner specified by the manufacturer and in the proportions indicated, complete all as specified and directed.Note: WPC will be measured and paid separately as supply only.
3M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surface (Internally) including finishing even and smooth without using extra cement complete all as specified and directed.
4Supply only integral WPC of approval make/brand complete all as specified and directed.
5M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening primer complete all as specified and directed.
6M&L for 1mm thick wall care putty on wall complete all as specified and directed.
7M&L for preparing newly plastered surfaces of finishing walls with acrylic smooth exterior paint (weather coat) of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 sqm, complete all as specified and directed.
8Dismanting boarding any decription fixed in any position with nails complete all as specified and directed.
9M&L for Hard Core Broken stone of gauge n.exc 63mm deposited, spread, levelled in layers n.exc 15cm thick watered and rammed to surface.
10M&L for sand filling under floor including watering and consolidation complete all as specified and directed.
11M & L for 100mm thick PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in flooring & finishing the surfaces rough to receive screed bed complete as specified and directed.
12Dismantling floors,hearth or wall tilling including cememt mortar beding (but not backing),and rubbish off the premises complete all as specified and directed.
13M&L for Non-skid ceramic coloured tiles 7 to 8mm thick area of each tiles execeeding 0.18 Sqm but n.exc 0.38 Sqm in floor, over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed.
14M&L for Non-skid ceramic coloured tiles 7 to 8mm thick area of each tiles execeeding 0.18 Sqm but n.exc 0.38 Sqm in in skirting, over 10mm thick screed bed in CM 1:4 on walls set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed.
15S & F Glazed ceramic coloured tiles of 450x350x7mm thick tiles on vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match, over backing coat of in CM 1:3, 10mm thick complete all as specified and directed.
16Demolition of ceiling boards (fiber, pulp, insulation etc) or insulation boards /slabs/blankets any thickness including cover fillets complete all as specified and directed.
17S&F aluminium anodised snap grid frame work of size 605mm X 605mm framework for ceiling with aluminium tee section of size 23.5mm X 26.4mm X 1.4mm thick and aluminium angle section of size 36.5mm X 25mm X 1.4mm thick, for false ceiling incl Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40X3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long incl 4mm thick non asbestos E-board, HSPC fixed to frame complete all as specified and as directed.
18Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillers etc but excluding ashlar facings, dressed stonework and precast complete all as specified and directed.
19M&L brick work with Fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
20Dismantling of plain or corrugated steel sheets any gauge any thickness including nainital or similar pattern roof covering complete all as specified and directed.
21S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
22S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
23Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thick (below or above ground level) as specified.
24M&L PCC 1:2:4, type B0 (using 12.5mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
25M&L for providing 75mm thick PCC 1:3:6 type C2 (40mm graded aggregate) as in plinth protection and paving finishing the surface even and smooth without using extra cement complete all as specified and directed.
26M&L forming 12mm thick expansion joint filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'B' for 75mm thick slab complete all as specified and directed.
27Taking down chowkats or frame not exc 1.5 sqm with shutter (with out taking off shutter from frame) all as specified and removing from site complete all as specified and directed.
28Taking down chowkats or frame not 1.5 sqm but n.exc 4 sqm with shutter (with out taking off shutter from frame) all as specified and removing from site and as directed.
29Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
30S&F framed work such as grills gratings, etc. with end of bars shouldered and/or riveted, or forged into spikes; framed guard bar; barred iron doors; ladders; frame of cupboard; walk ways; railings; framework of water tanks and similar work conforming to Fe. 290.Gde-E-165 complete all as specified and directed.
31Roof truses (framed), trussed, purlins, crane gantries, rails and fasternings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleats etc.Fe-290 (Gde E-165) complete all as specified and directed.
32S&F pressed steell door frame 105x60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plates comlete as specified and directed (pcc filling of holloow section measured and paid seprately) complete all as specified and directed.
33S&F 35mm thick 2nd class hardwood rail and style Factory made plain frames, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (part-1), kiln seasoned and chemically treated : supplied and fitted to chowkhats as specified.
34S&F of anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed
35M&L for Anodised aluminium powder coated window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
36M&L for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction.
37S&F 4mm thick sheet glass ordinary quality and glazing with oil putty and wooden beads in square n.exe 0.50sqm in each pane all as specified.
38S&F 150 mm size aluminium handle cast type anodised complete complete all as specified and directed.
39S&F 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed.
40M&L preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer.
41M&L for preparation of New surface applying two coat of synthetic enamel paint over one coat of red oxide on steel surface over 10cm grith.
42S&F 20 mm thick, second class hard wood boarding clean sawn, planed one side with butt joints and fixed with nails in any situation as in eaves board, etc complete as specified and directed.
43S&F PVC (SWR) half round gutter drain pipe 180mm bore complete all as specified.
44S&F 180mm PVC (SWR) joint socket as in gutter drain pipe complete complete all as specified.
45S&F 180mm PVC (SWR) joint tee with end cap as in gutter drain pipe complete all as specified
46S&F 180mm PVC (SWR) pipe clamp complete all as specified and as directed by Eng-in-charge.
47S&F rain water drainage pipes PVC(SWR) pipes single socketed 110mm bore in any length with rubber rings joints fixed to walls.
48S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed.
49M&L 2nd class HW plain fillets, square, rectangular or traingular in section, clean sawn, secured with nails or brads are exc 13 &n.exc 25 sqcm for panelling complete all as specified and directed.
50M&L for 12mm Plywood, grade BWP, type BB fixed with Screw to timber frame work as specified.
51M&L 5mm Prelaminated sheet as per single side make: Rajshri fixed to wall for panelling as specified and as directed by Eng-in-Charge
52M & L PCC typeC-1,1: 3:6 (20mm graded stone aggt) for cills,hold fast filling of hollow of pressed steel door frame etc complete all as specified and directed.
53M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
54M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and as directed.
55S&F for Aluminium anodised sliding door bolts of size 300mm long, with hasp & staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extreded sections or cast aluminium alloy complete all as specified and as directed.
56Taking down copper/aluminium point wiring (light, fan, socket or power) complete fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
57Taking down DB's including MCB's etc., complete all as specified and directed.
58Taking down sub main wiring of any size including making good the disturbed surfaces, complete all as specified and directed.
59M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor FRLS/FRLSH cable 1.5 Sq mm size 1100V grade in and including PVC conduit medium grade ISI marked duly concealed of 25mm dia (Sharing of Conduit shall be as per IS) including one No. 1.5 Sq mm single core PVC insulated copper cable for continuous earth wire (green coloured) connected to earth dolly complete for one light /Bell point controlled by one 5 Amp switch one way including factory made GI concealed box sutaible for modular switch/sockets etc ISI mark and making good disturbed surface of walls & floors etc., complete all as specified and directed. [Note - Wiring shall be circuit type and Nos of conductor in conduit shall be taken as per orders].
60One light/bell point/Exhaust fan point controlled by one, 1- way switches.
61One socket outlet, 3 pin 5/6 Amps on same Board
62One socket outlet, 3 pin 5/6 Amps, independent Board with conduit size 20/25mm dia med grade in same/other/independent circuit as per site requirements.
63Ditto- All as per Item No. 59.03 above but for socket outlet 15/16 Amps on independent board with 2.5 sqmm size cable for Phase, Neutral and Earth and size of concealed conduit 25mm med grade ISI marked (Sharing of Conduit shall be as per IS) complete all as specified and as directed.
64M&L for modular switch one way 6/10 Amps, 1 module, 240 Volts, all as specified and directed.
65M&L for modular socket, 6 Amps - 2/3 pin combined 2 module, 240 Volts, all as specified and directed.
66M&L for modular socket, 6Amps / 16Amps - 2/3 pin combined 2 module, 240 Volts, all as specified and directed.
67M&L for modular switch one way 16 Amps, 1 module, 240 Volts, all as specified and directed.
68M&L for modular blank plate, 1 module, 240 Volts, all as specified and directed.
69M&L for modular white cover plate with frame, 3 module, 240 Volts, all as specified and directed.
70M&L for modular white cover plate with frame, 4 module, 240 Volts, all as specified and directed.
71M&L for modular white cover plate with frame, 6 module, 240 Volts, all as specified and directed.
72M&L for modular white cover plate with frame, 8 module, 240 Volts, all as specified and directed.
73M & L for Ceiling rose, PVC/polycarbonate, insulated body, 3 terminals and 240 Volts ISI marked complete all as specified as directed.
74S & F in repair wall mounted LED Tube light fitting 20 Watts surface mounting general purpose LED Batterns in Extuted Aluminium housing including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site on 02 Nos new round blocks including complete all as specified and directed.
75S&F in repair of LED surface/recess mounted 2x2ft luminaire 36W with high performance LEDs and made out of sheet steel housing suitable for armstrong/ grid/ pop ceiling etc incl all allied accessories and connection complete all as specified and directed.
76S & F in repair sleek LED Bulk head IP-66, fitting 10 watt suitable for outdoor and indoor areas in perfect synchronization with functionality and aesthetics incl suitable mounting PVC boxes complete all as specified and directed.
77M&L for sub main wiring with two single core 6.0 Sqmm PVC (FRLSH) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC Conduit medium grade ISI marked of required size 25mm dia med grade with and including PVC insulated 6.0 Sqm single core single stranded copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directedNote: 1. Two runs of cable, one run of earth wire, one run of PVC Conduit 25mm dia medium grade will be measured and paid one unit.
78S & F in repair of Sheet Metal Enclouser Double door DB 240 volts, 12 way with rated bus bar, Single pole & neutral fixing on suitable rectanguler block, duly connected incoming and outgoing wires in DB and good finish to the old disturbed surface complete all as specified and direceted.
79S & F in repair MCB Single Pole Neutral C Curve 230 volts of capacity 32 Amp 10 KA and current capacity in the DB complete all and specified and directed.
80S & F in repair MCB Single Pole of Cap 6-32 Amp, C Curve 240 volts 10KA and current capacity in the DB complete all as specifeid and directed.
81S & F MCB, TPN of 415 volts, AC, 50 Hz of capacity 40-63 Amps 10 KA rupturing capacity complete all as specified and as directed.
82S & F in repair LED Building Security light fitting 30 watt energy saving environmental friendly long life LED Street light made up pressure die cast aluminium housing with high efficiency LEDs complete with fixing arrangements all as specified and directed.
83M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x60 cm x6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized earth lead wire of size 4mm dia by mean of bolts , nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate no 3 of SSR part-I, 2009 connected to earthing test point all as specified complete with excavation and earth work PCC pit with 50 mm thick RCC cover having suitable handle (10 mm MS Rod) 20 mm dia GI medium grade watering pipe with GI funnel with wire mesh 15 mm bore GI Pipe (light grade) for protection of earth lead conductor all as directed and testing on completion.
84S&F in repair/replacement of MCB DB, TPN 4 way, 415 volts, Double door type with sheet metal enclouser suitable for mounting incoming and outgoing MCBs complete all as specified and directed.
85Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates.Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56428608
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38.82 Lakhs
LAST DATE 04-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Bldg No P-8A (Bde Office) And T-41 (Sand Model Room) At Jalapahar Under Age (I) Darjeeling.
Basic Detail
Tender No CWE/136-WE/27 OF 2026-27
Bidding Type Tender
Location
City Gangtok
State sikkim
Key Dates
Publish Date 17 Jul 2026
Submission Date 04 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value 38.82 Lakhs
Tender Fee 500
EMD 77700
Exemption Available
Document List
BOQ_871256.xls
cbe8e02d-525f-452a-8e13-b257adc2eebe.html
tenderdocuments.pdf
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 04, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 12 days
Aug 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_871256.xls

html

cbe8e02d-525f-452a-8e13-b257adc2eebe.html

pdf

tenderdocuments.pdf

pdf

Tendernotice_1 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders