Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #56428565

Tender For Repair And Maintenance Of Ht Distribution System And Allied Works At Khanabal Grn Under Ge 861 Ews

Issued by Statutory Bodies & Commissions/Committees · Sabarkantha, Gujarat
Tender Value
7 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
3 days left
EMD
14000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sabarkantha → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Ht Distribution System And Allied Works At Khanabal Grn Under Ge 861 Ews

BOQ

Name of Work:- REPAIR AND MAINT OF HT DISTRIBUTION SYSTEM AND ALLIED WORKS AT KHANABAL GRN UNDER GE 861 EWS
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation of poles/stay/cable etc and getting out in Soft/dis integrated rock complete all as specified and directed.
2Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
3Removing surplus excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
4Supply and Laying in replacement reinforced precast concrete cable cover, class HV Type 2, flat, size 450 x 180 x 40mm complete all as specified and directed.
5M&L washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling and hard punning complete all as specified and directed.
6S&F in repairs GI tubing, 100 mm bore, light grade with all fittings/clamps of suitable size and nots and bolts, including one coat of red oxide primer and painting two coats of synthetic enamal paint complete, fixed to walls, pole ceiling or laid in trenches for cable protection complete all as specified and directed.
7Supply, laying commissioning and testing in replacement of XLPE under ground HT cable 33000 volts grade of size 185 Sqmm 3 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches/fixing on wall with the help of clamp, under road crossing through protection pipe etc complete all as specified and directed.
8Supply, laying commissioning and testing in replacement of XLPE under ground HT cable 11000 volts grade of size 95 Sqmm 3 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches/fixing on wall with the help of clamp, under road crossing through protection pipe etc complete all as specified and directed.
9Supply, laying commissioning and testing in replacement of XLPE under ground HT cable 11000 volts grade of size 70 Sqmm 3 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches/fixing on wall with the help of clamp, under road crossing through protection pipe etc complete all as specified and directed.
10M&L painting of two pole structure complete, scraping the old painted surfaces, cleaning and painting with two coats of synthetic enamel paint of silver colour over a coat of red oxide primer for steel tubuler pole and cement paint for PCC pole upto 1.2 mtr height from top of copping and then 03 nos of each black and yellow alternate strip of 20 cm width upto GL complete all as specified and directed.
11S&F in replacement Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
12Supply, Installation and testing and commissioning in replacement of 33 KV Lightening arresters expulsion type complete with all fittings transmission class discharge capacity 65 kilo Amps complete all as specified and directed.
13S&F in replacement lightening arrestor for out door use expulsion type with all fittings suitable for 11000 volts HT line transmission class of discharge capacity 65 KA complete all as specified and directed.
14S&F in repairs switch air break gang operated, triple pole, mechanically operated, mounted on insulators & steel frame with operation mechanism worked from ground level for current rating 200 Amps, 11000 volts complete all as specified and as directed. Note:- GOD shall be vertical type/horizental type which ever is suitable as per site requirement.
15S&F in replacement drop out expulsion fuse single pole 11000 volts, above 25 Amps and upto 50 Amps complete all as specified and directed.
16M&L spray painting of transformer upto 300 KVA capacity with two coats of synthetic enamel paint of smoke grey colour over a coat of red oxide primer after thoroughly preparing the surface complete all as specified and as directed.
17S&F in replacement cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 185 Sqmm complete all as specified and directed.
18S&F in replacement cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed.
19S&F in replacement Pin type, porcelain, vitreous, white, brown or green insulator including one Each galvanised old steel spindle, two galvanished iron washers and one galvanised iron nut. Suitable for 33 KV HT line as required on site complete all as specified and directed.
20S&F in replacement Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
21S&F in replacement HT Cable route indicator with a welded/riveted disc of 4 inch dia and engraved with cable with cable route marker made out of angle iron 40 x 40 x4 mm thick dug in ground with in and including PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) at approx distance 100 mtr including necessary earth work complete all as specified and directed.
22M&L for filtration of transformer oil to remove moisture, sludge, carbon particles and to achieve dielectric strength/rupturing capacity of oil upto 60 KV when tested at 4 mm gap and topping up of oil to the required level of the transformer indicator level complete all as specified and directed.Note: (a) Oil topping up shall be measured and paid separately.(b) Filtration shall be done at site and on line.(c) BDV test shall be carried out before the filtration and after the filtration & results recorded in triplicate duly signed by the contractor, MES rep. and Engr-in-charge (d) Dielectric strength of the oil shall not be less than 50 kV after filtration & the rate quoted for the items shall be deemed to include the filtration till the desired dielectric strength is achieved.
23Supply and filling new transformer oil topping up / change complete superior quality having di - electric strength not less than 60 KV and ISI marked of approved make complete all as specified and directed.Notes: Items rates deemed to include for (a) The transformer oil shall be ISI marked, and brought at site in sealed container only.(b) Collection of samples before and after topping up/changing including testing for dielectric strength.
24S&F in replacement breather assembly CI body of standard size filled with silica gel of transformer up to 630 KVA suitable for 33 KV/11KV/ 433 V complete with nuts, bolts and washers complete all as specified and directed.
25S&F in replacement synthtic Rubber insulated mats 3.0 mm thick for voltage upto 33 KV for electtical purpose as IS 15652-2006, (superseding IS 5424) suitable for elecrical shock safety of sizes 2 x 1m complete all as specified and directed.
26S&F in replacement synthtic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electtical purpose as IS 15652-2006, (superseding IS 5424) suitable for elecrical shock safety of sizes 2 x 1m complete all as specified and directed.
27M&L earth filling under floor, spreading and levelling in layers n exc. 25cm thick well ramming including watering as required in outdoor electrical sub stn area complete all as specified and directed.
28M&L loose filling and spread with broken stone aggregate of gauge 40 to 80 mm complete all as specified and directed.
29Supply and Spreading in Area graded course aggregate 20 mm complete all as specified and directed.
30M&L PCC type D2 (1:4:8) (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concreting complete all as specified and directed.
31M&L PCC 1:2 :4, type B1 (using 20mm graded crushed stone aggregate) as in coping, benching, walls or retaining walls of any shape including necessary formwork complete all as specified and directed.
32M&L earthing complete with galvanised earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level earth plate connected with GI strip of size 32x6mm by means of lugs, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 40mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to panel, including excavation, earth work, salt and charcoal dust mixed, GI pipe medium grade 20mm nominal bore for watering, funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 with suitable lifting handle and pit/chamber in PCC 1:3:6 type CI, including testing on completion complete all as specified and directed.
33Note :-An amount of Rs. 24700.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56428565
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 7 Lakhs
LAST DATE 01-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Ht Distribution System And Allied Works At Khanabal Grn Under Ge 861 Ews
Basic Detail
Tender No 134WE-44(T)/2026-27
Bidding Type Tender
Location
City Sabarkantha
State Gujarat
Key Dates
Publish Date 11 Jul 2026
Submission Date 01 Aug 2026
Open Date 03 Aug 2026
Finance
Tender Value 7 Lakhs
Tender Fee 500
EMD 14000
Exemption Not Available
Document List
079ff671-4e0b-4bfe-be0d-be248881b30f.html
BOQ_871422.xls
PS44.pdf
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

079ff671-4e0b-4bfe-be0d-be248881b30f.html

xls

BOQ_871422.xls

pdf

PS44.pdf

pdf

Tendernotice_1 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders