Tender For special Rep/Replacement Of Control Switch Panels/Lt Panel With Connected Lt Ug Cables And Connected Items At 23 Ed
Tender Value
48.59 Lakhs
Estimated cost
Bid Submission
29 Jul 2026
15 days left
EMD
97500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Rep/Replacement Of Control Switch Panels/Lt Panel With Connected Lt Ug Cables And Connected Items At 23 Ed
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth in soft/loose soil for foundations of poles, stays, cables, pipes etc., including getting out, complete, all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.50 m wide and exceeding 1.50 m but not exceeding 3.00 m in depth in any type of soil for foundations of poles, including getting out, complete, all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in thickness, complete, all as specified and directed. |
| 4 | Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed. |
| 5 | M&L for PCC 1:2:4, Type B-1 (using 20 mm graded stone aggregate) as coping/pedestal for new and existing poles, including necessary formwork and finishing exposed surfaces fair and even, complete, all as specified and directed. |
| 6 | M&L for PCC 1:3:6, Type C-2 (using 20 mm graded stone aggregate) as mass concrete in foundations for poles, stays and similar works, complete, all as specified and directed. |
| 7 | M&L for sand cushioning to underground cables by providing 8 cm thick sand bed below the cable and 15 cm thick sand cover above the cable (compacted to 18 cm overall), including proper laying and dressing of cable, complete, all as specified and directed. |
| 8 | M&L for providing Sub-Class 'B' bricks for cable protection, laid dry and flat transversely over underground electric cables on sand cushioning, with the width of protection equal to the length of the brick, complete, all as specified and directed. |
| 9 | S&F galvanised steel pipe, light grade, 80 mm bore, for mechanical protection of underground cable/earthing strip, complete, all as specified and directed. |
| 10 | S&F galvanised steel pipe, light grade, 50 mm bore, for mechanical protection of underground cable/earthing strip, complete, all as specified and directed. |
| 11 | Supply, laying, testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip/wire armoured, heavy duty electric power cable, LT 1100 Volts grade, with stranded aluminium conductor, 3.5 core, 120 sq mm, complete, all as specified and directed. |
| 12 | All as per Item No. 11.00 hereinbefore, but with 3.5 core, 95 sq mm aluminium conductor cable, complete, all as specified and directed. |
| 13 | All as per Item No. 11.00 hereinbefore, but with 3.5 core, 50 sq mm aluminium conductor cable, complete, all as specified and directed. |
| 14 | All as per Item No. 11.00 hereinbefore, but with 3.5 core, 35 sq mm aluminium conductor cable, complete, all as specified and directed. |
| 15 | All as per Item No. 11.00 hereinbefore, but with 4 core, 25 sq mm aluminium conductor cable, complete, all as specified and directed. |
| 16 | All as per Item No. 11.00 hereinbefore, but with 4 core, 16 sq mm aluminium conductor cable, complete, all as specified and directed. |
| 17 | Taking down unserviceable LT underground cables of any type and size, complete, all as specified and directed. |
| 18 | Dismantling unserviceable LT panel boards, loop boxes and timer panels, including taking down and demolition of plain cement concrete foundation/pedestal, complete, all as specified and directed. |
| 19 | Supply, installation, testing and commissioning of cubicle type, outdoor, CPRI approved LT feeder pillar, platform mounted, factory fabricated, totally enclosed, dust and vermin proof, double door, front operated with locking arrangement, fabricated from 3.15 mm thick CRCA sheet with suitable structural frame, detachable gland plates, cable entry and exit chambers, aluminium busbars of 1000 Amps capacity for 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply, complete with internal wiring, insulators, indicating lamps, multifunction digital meter, mounted on MS angle frame (50×50×6 mm) grouted in PCC foundation, comprising one No. 630 Amps, 4 Pole, 50 kA, draw-out type ACB with microprocessor release, overload, short circuit, earth fault and instantaneous protection as incomer, one No. 250 Amps, 4 Pole, 25 kA MCCB, four Nos. 200 Amps, 4 Pole, 25 kA MCCBs and four Nos. 160 Amps, 4 Pole, 16 kA MCCBs as outgoing feeders, complete, all as specified and directed. |
| 20 | Supply, fabrication, installation, testing and commissioning of cubicle type outdoor weatherproof LT busbar chamber fabricated from 3.15 mm thick CRCA sheet, powder coated, with hinged lockable front and rear doors, cable chamber, aluminium busbars of 400 Amps capacity suitable for 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply, complete with control wiring, aluminium busbars, cable glands, aluminium lugs, multifunction digital meter, LED phase indication lamps, one No. 200 Amps, 4 Pole, 36 kA MCCB with adjustable microprocessor release as incomer, mounted on PCC foundation with MS angle frame, complete, all as specified and directed. |
| 21 | Supply, fabrication, installation, testing and commissioning of compartmentalised outdoor weatherproof busbar chamber fabricated from 3.15 mm thick CRCA steel sheet with suitable pressed steel framework, sloping canopy, detachable bottom gland plates, hinged lockable front and rear doors, cable entry and exit chambers, aluminium busbar chamber, separate switchgear compartment, louvers and ventilation openings, mounted on MS angle iron framework/PCC pedestal complete with excavation, earthwork and PCC foundation, comprising four Nos. aluminium busbars of 400 Amps continuous current rating insulated with PVC heat shrinkable colour sleeves and mounted on fibre reinforced insulators, one No. 200 Amps, 4 Pole, 36 kA fixed thermal magnetic release MCCB, one No. 200 Amps, 4 Pole on-load changeover switch, one set of LED phase indicating lamps for RYB phases, complete. Note: MCCB shall be front handle operated, complete, all as specified and directed. |
| 22 | Supply, fabrication, installation, testing and commissioning of compartmentalised outdoor weatherproof busbar chamber fabricated from 3.00 mm thick CRCA steel sheet with suitable pressed steel framework, sloping canopy, detachable bottom gland plates, hinged lockable front and rear doors, cable entry and exit chambers, aluminium busbar chamber, separate switchgear compartment, louvers and ventilation openings, mounted on PCC pedestal including taking down existing busbar chamber and demolition of existing PCC foundation, comprising four Nos. aluminium busbars of 600 Amps continuous current rating insulated with PVC heat shrinkable colour sleeves and mounted on fibre reinforced insulators, one No. 400 Amps, 4 Pole, 36 kA fixed thermal magnetic release MCCB, one No. 400 Amps, 4 Pole on-load changeover switch and one set of LED phase indicating lamps for RYB phases. Note: MCCB shall be front handle operated, complete, all as specified and directed. |
| 23 | Supply, installation, testing and commissioning of cubicle type outdoor LT feeder pillar, CPRI approved, platform mounted, factory fabricated, dust and vermin proof, double door, front operated with locking arrangement, fabricated from 3.15 mm thick CRCA sheet with suitable structural framework, detachable gland plates, cable entry and exit chambers, aluminium busbars of 600 Amps capacity suitable for 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply, complete with internal wiring, insulators, one No. 400 Amps, 4 Pole, 36 kA MCCB and one No. 400 Amps, 4 Pole on-load changeover switch as incomers, one No. 315 Amps, 4 Pole, 25 kA MCCB and one No. 200 Amps, 4 Pole, 25 kA MCCB as outgoing feeders, LED phase indicating lamps and multifunction digital meter, mounted on MS angle frame grouted in PCC foundation, complete, all as specified and directed. |
| 24 | Supply, installation, testing and commissioning of cubicle type indoor LT feeder pillar, CPRI approved, platform mounted, factory fabricated, dust and vermin proof, double door, front operated with locking arrangement, fabricated from 3.15 mm thick CRCA sheet with suitable structural framework, detachable gland plates, cable entry and exit chambers, aluminium busbars of 600 Amps capacity suitable for 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply, complete with internal wiring, insulators, one No. 400 Amps, 4 Pole, 25 kA MCCB as incomer, four Nos. 200 Amps, 4 Pole, 25 kA MCCBs as outgoing feeders, LED phase indicating lamps and multifunction digital meter, mounted on MS angle frame grouted in PCC foundation, complete, all as specified and directed. |
| 25 | Supply, installation, testing and commissioning of cubicle type indoor LT feeder pillar, CPRI approved, platform mounted, factory fabricated, dust and vermin proof, double door, front operated with locking arrangement, fabricated from 3.15 mm thick CRCA sheet with suitable structural framework, detachable gland plates, cable entry and exit chambers, aluminium busbars of 400 Amps capacity suitable for 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply, complete with internal wiring, insulators, one No. 250 Amps, 4 Pole, 25 kA MCCB as incomer, six Nos. 100 Amps, 4 Pole, 25 kA MCCBs as outgoing feeders, LED phase indicating lamps and multifunction digital meter, mounted on MS angle frame grouted in PCC foundation, complete, all as specified and directed. |
| 26 | Supply, fixing, testing and commissioning of outdoor kiosk type LT timer panel fabricated from 3.00 mm thick CRCA sheet with sloping canopy, epoxy powder coated Siemens grey textured finish, mounted on 40 × 40 × 6 mm MS angle frame, comprising one No. 100 Amps, 4 Pole, 25 kA thermal magnetic release MCCB as incomer, one No. 60 Amps, 3 Pole power contactor, one No. photosensitive light sensing timer (220–240 Volts AC, 10 Amps maximum), one set of four Nos. 200 Amps aluminium busbars insulated with PVC colour coded heat shrink sleeves and mounted on suitable insulators, complete with internal wiring using PVC insulated copper conductor, one set of LED phase indication lamps for RYB phases, including taking down existing unserviceable timer panel, complete, all as specified and directed. |
| 27 | Dismantling unserviceable electric poles of any type and size including demolition of PCC foundation, taking down complete and depositing serviceable materials under Schedule of Credit, complete, all as specified and directed. |
| 28 | Supply and erect steel tubular swaged pole, Type 410 SP-31, 9.00 m long, in replacement of unserviceable PCC pole, complete with cast iron base plate, taper plug, bolts, nuts and screws, including two coats of aluminium paint over one coat of red oxide primer. Note: Excavation, earthwork and PCC foundation shall be measured and paid separately under relevant items, complete, all as specified and directed. |
| 29 | Supply and fixing in replacement of thermoplastic outdoor cable junction box, IP-55 protected, weatherproof, dustproof and shockproof, hinged/screwed cover type, size 200 × 160 × 98 mm, suitable for 415 Volts, 3 Phase, 4 Wire system with incoming and outgoing terminals, provision for single phase outgoing connection to light fitting, one No. 6 Amps SP MCB, screwless clamp terminals, metric knockouts and cable glands suitable for 16 sq mm to 25 sq mm cable, complete, all as specified and directed. |
| 30 | Supply and fixing in replacement of PVC insulated, PVC sheathed, multi-stranded copper conductor cable, 2.5 sq mm, 3 core, complete, all as specified and directed. |
| 31 | Supply and fixing street light mounting bracket fabricated from 40 mm bore light grade galvanised steel pipe, bent to the required shape, overall length 1.50 m with projection 900 mm × 600 mm, including two Nos. MS clamps, nuts, bolts, washers and painting with two coats of aluminium paint over one coat of red oxide primer, complete, all as specified and directed. |
| 32 | Taking down unserviceable light fittings of any type, size and wattage from poles/buildings, complete, all as specified and directed. |
| 33 | Supply and fixing LED street/security light fitting, 60 Watts, pressure die-cast aluminium housing with toughened glass, high-power LEDs with secondary optics, minimum IP-66 degree of protection, complete with electronic driver, connector block, mounting arrangement, internal wiring, making electrical connections and fixing to existing bracket/pole, complete, all as specified and directed. |
| 34 | M&L for earthing complete with galvanised steel earth plate electrode 600 × 600 × 6 mm thick, buried vertically in the ground at a depth not less than 2.25 m below ground level, with the top edge of the earth plate not less than 1.50 m below ground level, connected to 32 × 6 mm galvanised iron strip, including 40 mm bore light grade GI protection pipe for earth strip and 40 mm bore medium grade GI watering pipe with funnel, wire mesh and MS cap, 30 × 30 × 30 cm PCC (1:2:4 Type B-1) chamber, alternate layers of charcoal and common salt 150 mm thick all around the earth plate, excavation, refilling and disposal of surplus excavated soil, complete as shown in Plate No. 3 of SSR Part-I. Note: All joints between strip and strip or strip and earth plate shall be made by welding, complete, all as specified and directed. |
| 35 | M&L for earthing complete with galvanised steel earth plate electrode 600 × 600 × 6 mm thick, buried vertically in the ground at a depth not less than 2.25 m below ground level, with the top edge of the earth plate not less than 1.50 m below ground level, connected to 4 mm dia galvanised iron earth wire, including 40 mm bore light grade GI protection pipe for earth wire and 40 mm bore medium grade GI watering pipe with funnel, wire mesh and MS cap, 30 × 30 × 30 cm PCC (1:2:4 Type B-1) chamber, alternate layers of charcoal and common salt 150 mm thick all around the earth plate, excavation, refilling and disposal of surplus excavated soil, complete as shown in Plate No. 3 of SSR Part-I, complete, all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysJul 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender