Tender For Term Contract For Erection Of Steel Tubular Poles, Octagonal Poles And High Mast Lights And Light Fitting In Delhi Cantt Area
Tender Value
1.70 Crore
Estimated cost
Bid Submission
04 Aug 2026
17 days left
EMD
2.45 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Term Contract For Erection Of Steel Tubular Poles, Octagonal Poles And High Mast Lights And Light Fitting In Delhi Cantt Area
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' |
| 2 | Supplying transporting to site and fixing of steel tubulor poles swaged type in three sections as specified Type 410, SP 25 9 metre long with single arm bracket made out of MS pipe of outer dia 60.3 mm and thickness 2.90 mm with 50 mm dia Nipple suitable to fix light fittings, along with MS plate of size 34 CM x34 CM x6 mm thick welded at the bottom of pipe including painting of poles with two coat of aluminum paint over a coat of red oxide zinc chrome primer on exposed surfaces and black bituminous paint on steel surface embedded in concrete and painting black and yellow paint strips up to 1.5m from plinth block and numbering of poles with 75 mm (3”) high letters and figure at height of 2400mm (8’) from the ground level in white paint over black paint conforming to IS: 2713 ( Part-II)-1980as specified and directed by Engineer –in-Charge. |
| 3 | Supplying transporting to site and fixing of steel tubulor poles swaged type in three sections as specified Type 410,SP-4 7.50 Mt. long with single arm bracket made out of MS pipe of outer dia 60.3 mm and thickness 2.90 mm with 50 mm dia Nipple suitable to fix light fittings, along with MS plate of size 34 CM x34 CM x6 mm thick welded at the bottom of pipe including painting of poles with two coat of aluminum paint over a coat of red oxide zinc chrome primer on exposed surfaces and black bituminous paint on steel surface embedded in concrete and painting black and yellow paint strips up to 1.5m from plinth block and numbering of poles with 75 mm (3”) high letters and figure at height of 2400 mm (8’) from the ground level in white paint over black paint conforming to IS: 2713 ( Part-II)-1980as specified and directed by Engineer –in-Charge. |
| 4 | M/L supply and erecting of octagonal poles of 7.0metre height with 150 mm bottom Dia75 mm at top made out of 3mm thick MS sheet along with galvanized base plate of size 225x225x16 mm suitable to with stand Maximum. Wind speed 169 KM/Hr and suitable for mounting double or single arm bracket with street light fitting . The internal and external surfaces of the pole shall be hot dip galvanized to 65 microns DFT. The pole will have a weather proof comonflaged junction box at about 5 mm height with flush cover for cable termination block and earth stud with nuts washers etc including provision of drawing cable size upto 2 no, 2 core , 16 sqmm including supply 4 nos 20x750 mm long J type EN8 grade foundation bolts with nuts and washers and 63 amps terminal block suitable for 2 core 16 sqmm conductor cable termination and including providing GI pipe medium grade bracket of suitable length and size as directed for fixing of light fitting. The pole should be complete in all respect with all accessories required including painting of poles as directed by Engineer-in- Charge. |
| 5 | S/F , laying jointing of two run of PVC insulated cable 2.5. sq mm size with copper conductor and connecting from kiosk box to light fittings and main Board to fittings all as specified and directed by Engineer in-Charge. |
| 6 | S/F kiosk box weather proof made out of Engineering plastic one piece moulding of size 30x20x10 cm including 30 amps aluminum bus bar(two strips) mounted on the bus-bar insulator of inflammable material MCB 6 Amp Current rating for controlling street light complete to be mounted on pole with suitable clamps made out of MS flat of 25x3 mm with nut bolts and washers including provisions of shutter to be opened/closed vertically locking arrangement complete including danger notice as directed by Engineer-in- Charge. |
| 7 | Supplying /installation/testing and commissioning feeder pillar outdoor, cubical type, weather proof totally enclosed suitable for 440 V , 3 phase,50 C/s electric supply fabricated out of angle, 40 mx40m x6mm and Ms plain sheet 2 mm thick complete with two coats of spray painting of enamel paint, with a prior coat of primer, comprising of the following: a) Aluminum bus bar TPN , 3 phase, 4 strips-100 Amp. 1set.b) Incoming MCB TPN 63 Amp -1 No.c) OutgoingMCB TPN 32Amps. – 1 No.d) MCB Single phase neutral (SPN) outgoing - 4 Nos. 32 Amps.e) 24 Hrs electronic Timer- 01 no.f) 40 Amp TP Air brake contactor -01g) Heavy duty godown lock- 02 nos.h) Termination incoming /outgoing cable with suitable size of ferrules and compression gland.i) Hinged door open able on both side with heavy duty locking system-2 no.j) Canopy at Top.k) Legs of suitable length made out of 40 mmx40mmx6 mm angle iron including grouting the legs in 1:2:4 CC all as directed by the Engineer-in-charge.(Foundation concrete for fixing shall be paid separately) |
| 8 | M/L MCB single pole and neutral with PVC enclosures 32 Amps including connection to operate the street light |
| 9 | Boring hole horizontally under ground at required level with trenchless digging machine or manually suitable to pass 50 mm dia MS pipe in the bored hole under the road including passing of cable of size 2x16 sqm and disposal of spoil to a distance n exc 125 m all as specified and directed by the Engineer in Charge (MS pipe and fitting measured and paid separately). |
| 10 | S.F and laying into horizontal bore hole under the road 50 mm dia MS pipe heavy duty 3.25 mm wall thickness, welded and socketed ends as specified and directed by Engineer in-Charge. |
| 11 | S/F installation testing of feeder pillar outdoor cubical type, weather proof totally enclosed suitable for 440V, 3 phase, 50 HZ electric supply fabricated out of angle 40x40x6mm & MS plain sheet of 2mm thick complete with two coats of spray painting of enameled paint, with a prior coat of primer, comprising of the following for termination of cable connection other MES feeder pillara) Aluminium bus bar TPN-300 Amp- 1 setb) Incoming MCCB 250 Amp-01 No.c) Out going MCCB 200 Amp- 01 No.d) Conopy at the tope) Legs of suitable length made out of 40mmx40mmx6mm angle iron and including grouting of lengs in CC 1:2:4f) Cable gland as per cable size and number of cables |
| 12 | S.I.T & C of continuously tapered multifaceted and polygonal cross section High Mast as per detailed specification and details givena) ½ section having suitable sectional length with slip joints between sections without any circumpherence welding.b) Double drum winch with separate handle operation for manual operation and motorised operation of winch with a torque limiting device for safe docking of carriage.c) Raising /lowering type lantern carriage designed to carry 6 nos luminaries; of 1 x 250 watts control gear box, junction box and top pulley assemble with weather proof cover.d) Necessary suitable length for lowering and rising of lantern carriage of stainless steel wire ropes of 7/19 construction with minimum 6mm dia) and multi core flexible copper power cable e) Hinged service door in base section base plate earthing terminal. f) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. g) Complete with other provision for execution in the confirmation with detailed technical specifications.h) Lightning conductor finial made of 25mm dia 300 mm long G.I. tube having single prong.i) Integral single power tool (electrical) for lowering and raising of high mast .j) Anchor plate, templates, foundation bolts manufactured from special steel along with nuts washers etc. 12.00 meter High mast(Foundation concrete for fixing shall be paid separately) |
| 13 | S.I.T & C of continuously tapered multifaceted and polygonal cross section High Mast as per detailed specification and details givena) ½ section having suitable sectional length with slip joints between sections without any circumpherence welding.b) Double drum winch with separate handle operation for manual operation and motorised operation of winch with a torque limiting device for safe docking of carriage.c) Raising /lowering type lantern carriage designed to carry 6 nos luminaries; of 1 x 250 watts control gear box, junction box and top pulley assemble with weather proof cover.d) Necessary suitable length for lowering and rising of lantern carriage of stainless steel wire ropes of 7/19 construction with minimum 6mm dia) and multi core flexible copper power cable e) Hinged service door in base section base plate earthing terminal. f) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. g) Complete with other provision for execution in the confirmation with detailed technical specifications.h) Lightning conductor finial made of 25mm dia 300 mm long G.I. tube having single prong.i) Integral single power tool ( electrical) for lowering and raising of high mast .j) Anchor plate, templates, foundation bolts manufactured from special steel along with nuts washers etc. 16.00 meter High mast (two sections)(Foundation concrete for fixing shall be paid separately) |
| 14 | S.I.T. & C of dust vermin and weather proof out door compartmentalized feeder pillar of suitable size made of 14 SWG M.S. sheet complete with the following :-a) Canopy at topb) Hinged door open able on both side with heavy duty locking system :- 02 nosc) Base frame with detachable cover on all side made out of 14 SWG steel sheet.d) Legs of suitable length made out of 40mmx40mmx6mm angle as directed by Engineer-n-chargese) Knock out holes at bottom for cable entryf) Earthing stud-02 nos g) One coat of primer and two coats of approved make & colour of synthetic enamel paint.h) 40 amps TPN MCB,16 K breaking capacity -01 No.i) 40 Amps TP air break contactor - 01 No.j) 24 hour Electronic timer – 01 No.k) Heavy duty godown lock – 02 Nos.l) power tool control with 02 nos 09 Amps contractorsm) raise/lower push buttonn) Termination incoming/ outgoing cables with suitable sizes of ferrules compression gland.o) Motor starter with contactor, bimetallic relay, single phasing preventer – 1 Set |
| 15 | M/L highly efficient high power LED street light (Flood) with lense aesthetically designed fitting with pressure die cast aluminum housing top opening service cover, reflector and enclosed with toughened glass IP-66 protection suitable to mount on 40mm dia mast along with wiring with copper wire of suitable size 150 watt conforming to IS-10322 part 5 section 3 2012) |
| 16 | M/L highly efficient high power LED street light (Flood) with lense aesthetically designed fitting with pressure die cast aluminum housing top opening service cover, reflector and enclosed with toughened glass IP-66 protection suitable to mount on 40mm dia mast along with wiring with copper wire of suitable size 120 watt conforming to IS -10322(part 5/Section 3 2012) |
| 17 | M/L XLPE insulated armoured cable with aluminum conductor 1100 Volt grade cross section area 35 x 3-1/2 core . |
| 18 | M/L Bus-bar chamber consisting of three phase and neutral aluminum strips of 100 Amp Capacity including connections with thimbles complete as specified |
| 19 | Laying of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning protective covering & refilling the trench |
| 20 | Upto 35 Sqmm |
| 21 | Above 35 Sqmt upto 95 Sqmm |
| 22 | Supply only of XLPE insulated aluminium armoured, heavy duty power cable 1.1 kv grade of following size |
| 23 | 50 sqmm size 4 core |
| 24 | 95 sqmm size 4 core |
| 25 | 25 sqmm size 4 core |
| 26 | 16 sqmm size 4 core |
| 27 | Electric Motor with pulley, other accessories and operating arrangement 1 HP 3 phase 440 volts suitable to take up and down the GI head frame carriage with light fittings up and down for maintenance as specified and directed by Engineer-in-Charge. |
| 28 | S/F testing commissioning of aviation obstruction lighting fixture with two 40W neon lamps yellow painted die cast aluminium alloy housing built in 75 VA step up transformer , heat resistant, clear thick glass and accessories aviation light including wiring from the feeder pillar to top of the mast as specified and directed by Engineer-in-Charge |
| 29 | S.F of the following in the in built box of mast for jointing cables for controlling the lighting system as specified and directed by Engineer-in-Charge(a) MCCB 63 Amp – 1 No.(b) Male female box – 01 No. 63Amp |
| 30 | M/L lighting arresters expulsion type complete with all fittings ,30 kilo Amp discharge capacity, distribution class |
| 31 | 2.0 Please Enable Macros to View BoQ information |
| 32 | 2.0 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents