Tender for Repair /Maint Of Summer Appliances, Split Ac, Window Ac, Ductable Type Ac, Cassette Type Ac And Other E/M Works At Af Stn Sulur
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for shifting of air conditioner, window/ split type capacity up to 2.0 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Supply and fix in replacement of flair nut of dia 5/8\\", 1/2\\", 3/8\\", 1/4\\", 1/16\\" suitable for 1.5 Ton / 2.0 Ton of split type AC complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Material and labour for pressure testing and rectifying the leakages found in the system of window /split type ACs capacity upto 2.0 Ton including vacuumizing, charging and checking the gas pressure to desire level for satisfactory functioning complete all as specified and as directed by Engineer-in-Charge.Note: Topping up of gas shall be measured and paid seperately |
| 4 | Supply and fix in replacement of hermetic sealed /rotary new compressor for window type AC of capacity upto 2.0 Ton including disconnecting the electrical and refrigerant connection of defective sealed unit of window type AC of capacity upto 2.0 Ton and connection of all pipe line & charging of refrigerant and testing complete all as specified and as directed by Engineer-in-Charge.Note:Compressor shall be purchased from manufacturer /authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase. |
| 5 | Supply and fix in replacement of front grill suitable for window type Air Conditioner of any make upto 2.0 TR capacity complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Supply and fix in replacement of selector switch suitable for window type air conditioner of any make upto 2.0 TR capacity complete all as specified and as directed by Engineer-in-Charge. |
| 7 | Supply and fix in replacement of condenser fan blade suitable for upto 2.0 Ton split /window AC complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Supply and fix in replacement of thermostat suitable for window type air conditioner of any make up to 2.0 TR capacity complete all as specified and as directed by Engineer-in-Charge. |
| 9 | Supply and fix in replacement of over load relay suitable for window type air conditioner of any make up to and including 2.0 TR capacity complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Supply and fix in replacement of overload protector for split AC upto 2.0 Ton capacity complete all as specified and as directed by Engineer-in-Charge. |
| 11 | Supply and fix in replacement of blower motor suitable for window type air conditioner of any make upto 2.0 TR capacity complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Supply and fix in replacement of condenser coil of window type AC upto and including 1.5 /2.0 Ton and connecting the same unit with refrigerant connections complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Supply and fix in replacement of condenser coil of split type AC upto 2.0 TR connecting the same unit with refrigerant connections complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Supply and fix in replacement of flexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Supply and filled refrigeration gas R-22 in manufacturer sealed cylinder for cooling equipments complete all as specified and as directed by Engineer-in-Charge.Note: Empty containers will be returned to contractor. |
| 16 | Supply and filled Refrigerant gas R410a / R32 suitable for cooling equipments complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Supply and fix in replacement of 3 pin metal clad plug top 20 Amps, AC 230 Volts for any type of AC complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Supply and fix in replacement of metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Supply and fix in replacement of dummy nut of dia 3/8\\", 1/4\\", 5/8\\", 1/2\\" suitable for 1.5 / 2.0 Ton of split type AC complete all as specified and as directed |
| 20 | Supply and fix in replacement of PVC insulated multi stranded copper conductor 3 core 2.5 Sqmm complete all as specified and as directed by Engineer-in-Charge. |
| 21 | Material and labour disconnecting electric connection from defective blower /fan motor and taking out from unit capacity 8.75TR of existing make and transporting to workshop, dismantling the burntout winding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enamelled copper winding wire as per maunufactrer instructions including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed by Engineer-in-Charge. |
| 22 | Supply and fix in replacement of outdoor fan motor suitable for small shaft condensing coil including blade suitable for ductable AC of 8.75 TR complete all as specified and as directed by Engineer-in-Charge. |
| 23 | Supply and fix in replacement of liquid line drier filter suitable for 8.75 TR ductable AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete complete all as specified and as directed by Engineer-in-Charge.Note: Supply and topping up of refrigerant gas shall be measured and paid seperately under relavent items. |
| 24 | Inspection, checking, adjustment and minor repair of unserviceable window type /split type AC /any type any capacity placed at any location including repair /replacement of defective parts, checking of electrical connection, condenser, gas leakage, PCB, condenser fan blade, indoor unit, outdoor unit, compressor, PVC pipe etc, complete all as specified and as directed by Engineer-in-Charge.Note: Repair /replacement of unserviceable parts shall be measured and paid separately |
| 25 | Supply and fix in replacement of single phase single pole contactor suitable for upto 2.0 Ton split type AC complete all as specified and as directed by Engineer-in-Charge. |
| 26 | Repair and maintenance of inverter type split AC of any capacity any make from any location including attending breakdown calls, routine maintenance and servicing, testing and commissioning complete all as specified and as directed by Engineer-in-Charge as mentioned below:-(a) Cleaning the body, evaporator and condenser with detergent, combining the pins and flushing with air blower.(b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower.(c) Testing all copper tube, joints, leads for any leaking and Top up with the refrigerant gas if necessary. Please Enable Macros to View BoQ information |
| 27 | Repair and maintenance of inverter type split AC of any capacity any make from any location including attending breakdown calls, routine maintenance and servicing, testing and commissioning complete all as specified and as directed by Engineer-in-Charge as mentioned below:-(a) Cleaning the body, evaporator and condenser with detergent, combining the pins and flushing with air blower.(b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower.(c) Testing all copper tube, joints, leads for any leaking and Top up with the refrigerant gas if necessary. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.