Tender For Repair/Maint Of Fan Geyser, Internal Electrical, External Water Suppy, Tube Well , Chlorinationa Plant, Pump, Cleaning Of Sump Well Manholes, Seages Line & Certain Repair To Path, Drain ,Compound Wall And Fencing Gate As 4 Afsb Varanasi Un
Tender Overview
Project Description
Tender for Repair/Maint Of Fan Geyser, Internal Electrical, External Water Suppy, Tube Well , Chlorinationa Plant, Pump, Cleaning Of Sump Well Manholes, Seages Line & Certain Repair To Path, Drain ,Compound Wall And Fencing Gate As 4 Afsb Varanasi Under Ge(Af) Goarkhpur.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur Name of Work: REPAIR/MAINT OF FAN GEYSER, INTERNAL ELECTRICAL, EXTERNAL WATER SUPPY, TUBE WELL , CHLORINATIONA PLANT, PUMP, CLEANING OF SUMP WELL MANHOLES, SEAGES LINE & CERTAIN REPAIR TO PATH, DRAIN ,COMPOUND WALL AND FENCING GATE AS 4 AFSB VARANASI UNDER GE(AF) GOARKHPUR. Contract No.: GE(AF)/GKP/E-36 OF 2026-27 File No. 9475/E8 Serial Page No.18 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Descripion of items Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Disconnecting and taking down of burnt winding of ceiling fans including necessary dismantling, cutting and removing of unsv windings, cleaning, segrigation of serviceable and unsv parts including re-windings of stator winding with super enameled copper wire of existing gauge and weight of approved make and brand and taping, quick heat varnishing, baking, drying in heat chamber to obtain proper insulating resistance and reassembling the fans including replacement of unsv parts and re-installation to the existing position and necessary transportation and testing complete for Ceiling Fan of 1400/1200 mm sweep of any make complete all as specified and as directed. |
| 3 | -----ditto----------but for Exhaust Fan of 450 mm sweep of any make |
| 4 | ------ditto---------but for Exhaust Fan of upto 300 mm sweep of any make |
| 5 | ---------ditto----- but for cabin/ padestal fan of 380 to 400 mm sweep of any make.Note For item No 1 to 4 : Rates are deemed to be inclusive for collection of fan from E/M store under contractor own arrangement, removing defective parts, burnt winding carefully, cleaning & re-assembling the fan after repair i.e. oiling, greasing, washer, lock bolts, connector, cross pin etc, depositing back to E/M store and testing complete to the satisfaction of Engineer-in-charge. (spare parts will be measured and paid seperately under relevent items) |
| 6 | M&L for identifying and rectifying day to day complaints of fans including taking down celiing fan / exhaust fan / Wall fan of any type / make / sweep from its location at OTM, md accn under AGE(AF) Varanasi cantt area, servicing of fans after removing blades, opening of fan at site and cleaning ball bearing,gun metal bush, filling grease /oil and changing of nut , screwes, check nuts, rubber reel, nut & bolts of size 15 mm to 60 mm including replacing defective condensor,ball bearing ,conecting wire,gun metal bush,lock nuts, crosspin ,ceiling rose etc if required and re-assembling of fan, blades, down rod, conopy etc and hanging back fan to its original location after cleaning of body, connecting to ceiling rose complete all as specified and directed . Note : (1) all spare i.e condenser, ball bearing,flexible wire, bush, shall be measured and paid under relevent item. (2) Cost of petty stores such as grease, lubricating oil, varnish, coil tie, lock nut , cross pin,check nuts,rubber seal etc are deemed to be included in quated rate. |
| 7 | S&F in replacement ball bearing No. 6200 to 6204 complete all as specified and directed. |
| 8 | Supply and fix in repairs fan capacitor 3.15 mfd |
| 9 | Supply and fix in repairs fan capacitor 2.5 mfd |
| 10 | Supply and fix in repairs fan capacitor 4 mfd |
| 11 | Supply and fix in repairs Twisted twin core flexible cable of size 24/0.0076 . |
| 12 | Supply and fix in repairs Gun metal bush for ceiling fan of any size. |
| 13 | Supply and fix in repairs Gun metal bush for exhaust fan of any size . |
| 14 | M&L for spray painting of ceiling fan 1200/ 1400 mm sweep with synthetic enamel paint including filing cavities with filler after cleaning of body, blades, down rods etc by scraping with emery paper including rewriting MES No of fan of letter size 2 cm height, using black paint all as directed . |
| 15 | M&L for spray painting of exhaust fan 300 to 400 mm sweep with synthetic enamel paint including filing cavities with filler after cleaning of body, blades, down rods etc by scraping with emery paper including rewriting MES No of fan of letter size 2 cm height, using black paint all as directed . |
| 16 | Fixing only exhaust fan of any type/sweep and fixing the same and connecting up including provision of cable of size 23/.0076 from ceiling rose/connector to fan. |
| 17 | Making hole for exhaust fan of suitable size (square/ round) and grouting nuts and bolts of suitable size in and including complete platering and make the disturbed surface as per existing wall complete all as specified and directed. |
| 18 | Supply and fix in repairs down rod for ceiling fan made out of 15 mm dia MS pipe complete with holes, slotted or threaded upto 0.6m long all as specified and directed. |
| 19 | Supply and fix in repairs down rod for ceiling fan made out of 15 mm dia MS pipe complite with holes, slotted or threaded upto 0.75m long all as specified and directed. |
| 20 | Supply and fix in repairs down rod for ceiling fan made out of 15 mm dia MS pipe complite with holes, slotted or threaded 0.75 to 1.50m long. long all as specified and directed. |
| 21 | Supply and Fix in repairs ceiling fan canopy(set of two) with nut and bolt of suitable size all as directed and specified. |
| 22 | Supply and fix in repair complete fan hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans complete all as specified and directed. |
| 23 | S&F in replacment motor, single phase for 200/250mm Exhaust fan as per sample complete all as specified and directed.Note : Old unsv fan motor will be deposited to E/M store. |
| 24 | M&L in replacement of exhaust fan blades as per existing pattern and size complete all as directed at site. |
| 25 | M&L in replacement wall fan blades as per existing pattern and size complete all as directed at site. |
| 26 | M&L in replacement Ceiling fan blades as per existing pattern and size (set of three) complete all as directed at site. |
| 27 | Supply and fix in repairs/ replacement Printed Circuit board (PCB) of ceiling fan 1200/1400mm sweep of any Make Havells/Crompton complete all as specified and direcetd by Engr-in-Charge. |
| 28 | Taking down the water heater (Geyser)storage type of any make of 25/35/50 litres capacity from any position, after disconnection of all electrical, water supply inlet and outlet connection and transportation for repair, further dismantling, segregation of serviceable and unserviceable parts, replacement unserviable parts and re-assembly the water heater and installation the same to their original position or as directed after all testing the of water heater complete all as specifed and as directed by the Engr-in-charge.Note : (a) Cost of transportation charges from E/M store to workshop and vice versa shall be deemed to be included in the item rate.(b) Replacement of defective parts shall be measured & paid separately under this BoQ items.(c) Descaling/ Welding/breezing/Painting of water heater if required shall be measured & paid separately under this BoQ items. |
| 29 | M& L for welding/breezing of water heater tank of any size, model at appropriate/bursting area of copper/mild steel inner tank and make 100% leak proof complete all as specifed and as directed. |
| 30 | M&L for descaling of water heater storage tank of any type, size and make by appling descaling solution complete all as specifed and as directed. |
| 31 | M & L for appling one coat of synthetic enemal paint first grade of approve make and colour by spray machine after preparation steel surfaces including writing MES No of 40mm size of letter for 50/35/25 Ltrs capacity of water heater complete all as specifed and as directed. |
| 32 | Supply and fix inner tank made of stainless steel for water heater of 50 ltrs capacity of exiting type, model complete all as specifed and as directed. |
| 33 | Supply and fix inner tank made of stainless steel for water heater of 25/35 ltrs capacity of exiting type, model complete all as specifed and as directed. |
| 34 | Supply and fixing apparatus plate suitable for water heater 25 / 35 / 50 ltrs capacity of approved make and as per exiting type and size incl rubber gasket, clips, nuts, bolts, and washers etc complete all as specifed and as directed. |
| 35 | Supply and fixing in repair thermostat switch (ISI mark) suitable for 25 / 35 / 50 ltrs capacity water heater (geysers) complete all as specifed and as directed. |
| 36 | Supply and fixing in repair heating element of 1.5KW any type as per sample ISI marked complete all as specified and directed. |
| 37 | Supply and fixing in repair heating element of 2.0KW any type as per sample ISI marked complete all as specified and directed. |
| 38 | Supply and fixing in repair neon indicating lamp, rectangular /round type as per existing model complete all as specifed and as directed. |
| 39 | Supply and fixing in repair pressure release valve 15 mm bore (ISI marked) for geyser 25 / 35 / 50 ltrs capacity complete all as specifed and as directed.' |
| 40 | Supply and fixing in repair safety valve for water heater of capacity 25/50 ltrs complete all as specifed and as directed. |
| 41 | Supply and fixing in repair apparatus plate rubber gasket suitable for six/seven/eight/nine hole assembly of suitable size of water heater of capacity 25/35/50 litres capacity complete all as specifed and as directed. |
| 42 | Supply and fixing in repair split bottom cover (two pieces) suitable for water heater 25/35/50 litres capacity duly painted, all as directed by Engr-in-Charge. |
| 43 | Supply and fixing 100 mm long and 12 mm dia anchor fastner nut and bolt with suitable washers complete all as specifed and as directed. |
| 44 | M&L for insulating material (glass wool) suitable water heater insulation complete all as specifed and as directed. |
| 45 | S & F in repair stop cocks brass CP 15 mm dia suitable for above geyser ISI Marked complete all as specifed and as directed. |
| 46 | Supply and fixing in repair hot and cold type PVC connection (ISI Mark) having 10 mm dia, 45 cm long with 02 Nos of Unions/ cup shaped pvc cover with washers complete all as specifed and as directed. |
| 47 | Supply and fixing in repair of plug top 3 pin 15 Amps complete all as specified and as diriected. |
| 48 | Supply and fixing in repair 2.5 Sqmm 3 Core (Nominal Area) PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 complete all as specified and as diriected. |
| 49 | Collecting and transporting of desert coolers from MES store yard/user bldgs to work shop and overhauling of fan motar, oiling to vertical pump including repair of unserviceable bolts and nuts with washers, clamps etc.complete and returning back to MES store yard/user locations complete all as specified and directed.(Note :-Parts except nut bolt & washers to be replaced will be measured and paid separately under respective items) |
| 50 | Supply & Fixing in repair fan motor per existing sample of capacity 1/7 HP or any HP complete set with arm and fan blade etc. ,230 volt,50Hz cycles A/C supply of make Summer Cool/CG /Havells/Bajaj complete in all respect. |
| 51 | Supply & Fixing in repair fan blade as per existing sample and size not exc. of 450 mm sweep suitable for fixing with fan motor fixed in desert coolers complete all as specifed and as directed. |
| 52 | Supply & Fixing in repair capacitor, 4 / 3.15 +/- 5% mfd rating complete all as specifed and as directed. |
| 53 | Supply & Fixing deset cooler's fan speed regulator ( three stage ie low, medium & high speed ) switch with Knob 230 V , AC supply complete all as specified and directed. |
| 54 | Supply and fixing in repair and replacement of submersible water pump for desert cooler as per sample approved complete all as specified and directed. |
| 55 | Supply & Fixing in repair plug top, 5 Amps, 230 Volts, 50 Hz, A/C supply complete all as specifed and as directed. |
| 56 | Supply & Fixing in repair PVC flexible copper conductor cable three core ,1.5 Sq mm size complete all as specifed and as directed. |
| 57 | S&F in repair elbows & distributor (Plastic set of 4) of desert cooler as per sample approved complete all as specified and directed. |
| 58 | Supply & Fixing in repair wood wool pad (set of 3) of good quality for desert cooler complete in all respected. |
| 59 | M & L for preparation of steel surface of desert coolers followed by painting with one coat of synthetic enameled paint complete on metallic surface external and internal complete in all respect as directed by Engr-in-Charge. |
| 60 | S & F in repair side panels made with 2.0 mm thick MS sheet as per existing size and sample for desert cooler complete all as specifed and as directed. |
| 61 | S & F in repair bottom tank made with 2.0 mm thick MS sheet as per existing size and sample for desert cooler complete all as specifed and as directed. |
| 62 | M & L for repair of unserviceable sealed unit (compressor) of water coolers with new sealed unit (recommended by manufactorer) sealed unit make kirloskar/Tecumsha for water cooler make Shri Ram / Usha / Voltas or Blue Star capacity from 150 Ltrs complete all as specifed and as directed. |
| 63 | M & L for repair of unserviceable sealed unit (compressor) of water coolers with new sealed unit (recommended by manufactorer) sealed unit make kirloskar/Tecumsha for water cooler make Shri Ram / Usha / Voltas or Blue Star capacity from 120 Ltrs complete all as specifed and as directed. |
| 64 | Supply & Fixing in repair relay assembly for water cooler of any capacity & make upto150 Ltrs complete all as specifed and as directed. |
| 65 | Supply & Fixing in repair Over load protector for water cooler of any capacity & make upto150 Ltrs complete all as specifed and as directed. |
| 66 | Supply & Fixing in repair Starting capacitor for water cooler of any capacity & make upto150 Ltrs complete all as specifed and as directed. |
| 67 | Supply & Fixing in repair running capacitor for water cooler of any capacity & make upto150 Ltrs complete all as specifed and as directed. |
| 68 | Supply & Fixing in repair thermostatic switch for water cooler of any capacity & make upto150 Ltrs complete all as specifed and as directed. |
| 69 | Supply & Fixing in repair chromium plated push cock, self closing, spring loaded type 15mm dia complete all as specifed and as directed. |
| 70 | Supply & Fixing in repair drain out PVC pipe, complete with clamp and washers, suitable for fixing in water waste tray (length of pipe 1.50 R.M. approximately) complete all as specifed and as directed. |
| 71 | Supply & Fixing in repair blower motor as per size & sample in water cooler, commissioning and testing complete in all respect complete all as specifed and as directed. |
| 72 | M & L for Repair of water cooler's body/base by cutting of rusted / deteriorated steel sheets and S & F new MS sheet of 1.6 mm thick for body and 3.16 mm thick for base with necessary spots welding including repair of legs as per existing size and applying red oxide primer on new sheet complete all as specified and directed.( Note:- 1. Finishing cost to be applied shall be deemed to be included in unit rate quoted by contractor. 2. Cost of taking down compressor or any other parts and refixing the same shall be measured and paid separately.) |
| 73 | M & L preparation of old painted surface of water coolers and applying one coat of super enameled paint by spray painting gun for water coolers any make and size upto 150Ltrs capacity all as specified and directed. |
| 74 | M & L for Repairs of water cooler's water storage tank by running contineous welding (gas welding) for prevention of leakage at places as directed by Engineer - in - Charge. |
| 75 | M & L and complete servicing of water cooler by cleanning of coils with caustic soda, removal of rust from sheet metal frame, cleaning of tank and cheacking of water connection and fixing in original position complete in all respects. |
| 76 | M & L for gas charging in water cooler by using refrigerant as per standared specific after proper flushing vacuuming detecting leakge,rectification of leakages commissioning and testing for water cooler. |
| 77 | M & L for Repair of refrigerators complete by cleaning of system properly with CTC. Charging refrigerant including repair of unserviceable sealed unit (Compressor) of Refrigerator with new sealed unit, recommended by manufacturer Make Kelvinator /Godrej /LG of 308/325 Ltrs capacity. |
| 78 | Supply and fixing in repair of box type relay for any make and capacity upto 310 ltrs refrigerator. |
| 79 | Supply and fixing in repair thermostatic switch for any make and capacity upto 310 ltrs refrigerator. |
| 80 | Supply & fixing in repair of wiring kit suitable for any make refrigerator of 165 to 310 Ltr capacity. |
| 81 | M & L for Repair of Deep Freezer complete by cleaning of system properly with CTC. Charging refrigerant including repair of unserviceable sealed unit (Compressor) of deep freezer with new sealed unit, recommended by manufacturer Make Voltas of 320 Ltrs capacity. |
| 82 | Supply & Fixing in repair blower motor as per size & sample in deep freezer, commissioning and testing complete in all respect. |
| 83 | M & L for Repair of window / Split type Air conditioner by repair of unserviceable sealed unit i.e.compressor (rotary or hermetic) ,cleaning of system properly with CTC and charging the refrigerant (including cost of refrigerant ) recommended by manufacturer of AC including commissioning and testing complete all as specified and directed by Engr - in - Charge at site for 2 TR Window / Split type AC. |
| 84 | All as per item cbove but 1.5 TR Window/Split for Air Conditioning. |
| 85 | S & F in repair condenser coil as per sample for 1.5 Ton A.C. Note : Charging of refrigerant including cost of refrigerant will be measured and paid separately under respective item. |
| 86 | S & F in repair relay suitable for split type AC / window type AC upto capacity of 2TR. |
| 87 | S & F in repair over load protector suitable for split type AC of 1.5 Ton. |
| 88 | S & F in repair for air conditioners, capacitor 36 / 45 / 50 +6 mfd +/- 5% ,440 V AC . |
| 89 | S & F in repair thermostatic switch suitable for 1.5 / 2 ton AC. |
| 90 | S & F in repalcement fan motor with blade as per size and sample suitable for FCU unit of Split type AC of capacity 1.5 Ton of make LG/Voltas/Blue Star complete all as specified and directed. |
| 91 | S & F in repalcement fan motor with blade as per size and sample suitable for FCU unit of Split type AC of capacity 2.0 Ton of make LG/Voltas/Blue Star complete all as specified and directed. |
| 92 | S & F in repalcement blower fan motor for indoor unit of Split type AC of capacity 1.5 Ton of make LG/Voltas/Blue Star complete all as specified and directed. |
| 93 | S & F in repalcement blower fan motor for indoor unit of Split type AC of capacity 2.0 Ton of make LG/Voltas/Blue Star complete all as specified and directed. |
| 94 | S & F in repalcement fan motor with blade for Window type AC of capacity 1.5 Ton of make LG/Voltas complete all as specified and directed. |
| 95 | M & L for gas charging in split type AC unit 1.5 TR capacity using refrigerant as per standard practice after flushing, vacuuming including detecting leakage, rectification leakage, commissioning and testing complete in all respect. |
| 96 | All as per item above but for split type AC unit of 2 TR capacity . |
| 97 | All as per item above but for window type AC unit of capacity 1.5/2 TR capacity . |
| 98 | S & F in repair power PCB as per sample suitable for 1.5/2 TR Split type AC, making connection & testing complete all as specified. |
| 99 | S & F in repair copper connection pipe with union at both ends and with insulation, between FCU unit and indoor unit of length twelve feet for 1.5/2 TR Split type AC, making connection & testing complete all as specified. |
| 100 | S & F in repair insulation on copper tubing suitable for split type AC. |
| 101 | S & F in repair drain hose pipe suitable for 1.5 / 2 TR split type AC. |
| 102 | S & F in repair air filter as per existing size suitable indoor unit of 1.5 TR split type AC. |
| 103 | S & F in repair auto chang over unit with inbuilt timmer (programmable for operation between 01 hour to 24 hrs) having facility to operate alternatively two AC upto capacity 2.0 TR , commissioning and testing complete all as specified. |
| 104 | M & L for complete servicing of Air conditioner window/split type including cleaning of colling coil and condenser by caustic soda solution including removal of dust by using blower/brush to external fins and from beneath assets, cleaning of base tray properly including oil to fan & condenser motor, tightening of all electrical connections with proper alignment including fitments in their locations and repairs of suction & discharge tubes complete in all respects. (Note :-Filling of refrigerant if required or parts to be replaced will be measured and paid separately under respective items) |
| 105 | M & L for Repair of voltage stabilizer of capacity 5 KVA/4KVA by carying out rewinding of main transformer, repair of volt meter, relay, timer and IC circuit as required and making functional and testing complete all as specified and directed . |
| 106 | M & L for Repair of voltage stabilizer of capacity 2 KVA/1 KVA by carying out rewinding of main transformer, repair of volt meter, relay, timer & IC circuit as required and testing complete all as specified and directed . |
| 107 | Maint repair of reverse osmosis with UV water purifier system five stage having storage capacity 10 Ltrs and flow capacity 15 Ltrs per hour by cleaning supply & fix in repair required parts such as connecting pipe, buster pump, filter element (pre carbon/ UFmembrane/RO inline carbon filter) adapter,UV lamp ,SMPS etc. and making RO complete serviceable & testing complete all as specified and directed for RO of make KENT / Aquafine / Aquasoft. |
| 108 | Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 109 | M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling and paneling on this PVC conduit/casing caping on surface will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including MS boxes for mounting modular switches, sockets, fan regulators etc for one light/fan point controlled by one switch complete all as specified and as directed by Engineer in Charge. Note :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. |
| 110 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on same board. |
| 111 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on independent board. |
| 112 | Ditto as above but for One bell point controlled by one 5 Amps bell push. |
| 113 | Ditto as above but for One light point controlled by two 5 Amps two way switch. |
| 114 | Ditto as above but for before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 115 | M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC casing caping on surface and 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including MS boxes for mounting switches, sockets, fan regulators etc for one light/fan point controlled by one switch complete all as specified and as directed by Engineer in Charge. |
| 116 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on same board. |
| 117 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on independent board. |
| 118 | Ditto as above but for One bell point controlled by one 5 Amps bell push. |
| 119 | Ditto as above but for One light point controlled by two 5 Amps two way switch. |
| 120 | Ditto as above but for using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 121 | S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed. |
| 122 | S&F switch piano, flush type 5/6 amp, single pole, two way 240 volt complete all as specified and directed. |
| 123 | S&F socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed. |
| 124 | S&F socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed. |
| 125 | S&F switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed. |
| 126 | S&F bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed. |
| 127 | Supply and fixing for electronic Fan regulator/dimmer 450 watt step type complete all as specified and directed. |
| 128 | S&F only modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed. |
| 129 | S&F only modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed. |
| 130 | S&F modular switch single pole 2 way, 1 module, 6 Amp complete all as specified and directed. |
| 131 | Supply and fixing Modular Bell push flush type,6 Amps fixed complete all as specified and directed |
| 132 | S&F only modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module complete all as specified and directed. |
| 133 | S&F only modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed. |
| 134 | S&F fan regulator modular electronic step up type, SP 230 volt complete all as specified and as directed. |
| 135 | S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed. |
| 136 | S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed. |
| 137 | S&F Call bell ding dong, AC single pole 240 volts complete all as specified and directed. |
| 138 | Taking down old unserviceable light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed. |
| 139 | Supply and fixing LED lights fitting 1x20 Watt , 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all accessories internally pre wired fixed to wall/ceiling incl fittings accessories all as specified. |
| 140 | S&F 10 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. |
| 141 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof recessed ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 142 | Supply and fixing round shape 15 watt 220 volts AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete |
| 143 | Supply and fixing of LED light of 6 Watts in recessed/surface ceiling mounted , high transmissitivity diffuser, high lumen ouput , 230 volts including electronic driver connector etc complete with all accessories internally pre wired and necessary mounting arrangements, from ceiling rose to fitting complete all as specified and as directed. |
| 144 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make: Phillips, Product SKU : WT202W LED 10S CW PSU S3 PC or equivalent to specified make in PS. |
| 145 | S&F, testing energy saving, die cast aluminium housing IP 65 protection, 25 W LED Bldg security light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Havells Cat No. ENDURA CITYLITEPLAT PLUS SL25WLED 757S ASYBOPC or equivalent iin Bajaj/ Philips/ CG/ WIPRO |
| 146 | S&F, testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED building security light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Havells Cat No. ENDURA CITYLITEPLAT PLUSSL35WLED 757SASYBOPC or equivalent iin Bajaj/Philips/CG/ WIPRO |
| 147 | S&F lamp LED 9/10 watt, 240 volts complete all as specified and directed. |
| 148 | Taking down carefully old and unserviceable sub main wiring of 2/3 runs or main-wiring of any size of aluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing caping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed. |
| 149 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 2.5 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 2.5 sqmm cable,one run of 2.5 sqmm cable and one run of PVC conduit will be measured as one unit |
| 150 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4.0 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4.0 sqmm cable and one run of PVC conduit will be measured as one unit |
| 151 | M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 4.0 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- four runs of 4.0 sqmm cable,one run of 4.0 sqmm cable and one run of PVC conduit will be measured as one unit |
| 152 | M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 6.0 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- four runs of 6.0 sqmm cable,one run of 6.0 sqmm cable and one run of PVC conduit will be measured as one unit |
| 153 | S&F modular type PVC enclosure with a two pin and earth plug and socket 16 Amps complete with one single pole MCB 20/25 Amps capacity complete all as specified and directed. |
| 154 | Taking down old unserviceable MCCB DBs / MCB DB / Main Switches including MCBs/ MCCBs/ Isolaters, complete all as specified and as directed.Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces. |
| 155 | S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed. Make: Havelle, SKU - DHDLVDOBGSFE04 |
| 156 | S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 157 | S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 158 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 159 | Taking down Unsv MCCb/MCB of any specification complete all as specified and directed. |
| 160 | S&F MCCB, 4 pole, 63-100 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed. |
| 161 | S&F MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed. |
| 162 | S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 163 | S&F MCB, SP, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 164 | S&F MCB, SPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 165 | S&F MCB, TPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 166 | S&F only tape insulation, 1100 volts grade 20mm width, 15 mtrs long complete all as specified and directed. |
| 167 | Supply and fixing in repair modular Switch 6 Amps single pole, one way complete all as specified and directed . |
| 168 | Supply and fixing in repair Modular Socket outlet, multi purpose, 5 Pin 6 Amps flush type complete all as specified and directed . |
| 169 | Supply and fixing in repair Modular Bell push flush type,6 Amps fixed complete all as specified and directed |
| 170 | Supply and fixing in repair Modular Socket outlet, multi purpose, 6 pin 16 Amps universal socket complete all as specified and directed . |
| 171 | Supply and fixing in repair Modular Switch 16 Amps single pole, one way complete all as specified and directed . |
| 172 | Supply and fixing in repair modular fan regulator 450 Watt of four step type complete all as specified and directed . |
| 173 | Supply and fixing in repair switch piano flush button single pole one way 5 amps, 240 Volts complete all as specified and directed. |
| 174 | Supply and fixing in repair socket outlet flush type 5 Amps, 5 pin, 240 Volts complete all as specified and directed. |
| 175 | S&F in repair socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed. |
| 176 | Supply and fixing in repair switch piano flush button single pole one way 15 Amp 240 volt complete all as specified and directed. |
| 177 | Supply and fixing in repair bell push single pole, 6 Amps, 240 Volts, flush type complete all as specified and directed. |
| 178 | Supply and fixing in repair for electronic Fan regulator/dimmer 450 watt step type complete all as specified and directed. |
| 179 | Supply and fixing in repair Ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed. |
| 180 | S&F in repair switch socket combination multipurpose 5 pin 5/15 Amps |
| 181 | Supply and fixing in repair for batten/angular fittings complete all as specified and directed. |
| 182 | Supply and fixing in repair Bell, AC 240 Volts,single pole complete all as specified and directed. |
| 183 | M&L Disconnecting & taking out Submersible Pump/Motor of various Capacities and lifting from bore hole of Pump Houses and Transporting to nearest Workshop for repairing including returning back after repairing and Re-instaltion & lowering in Original Position and Re-connection in water supply installation(starter/panel) and Testing complete all as specified and as directed by Engineer-in-charge.Note : Cost of repairs will be measured & paid separetely under respective item, here-in-after. |
| 184 | Dismantling & removing burn out submersible pump winding of capacity 45 HP pump set taking out the rotor from the body and cutting the burnt coils / winding, cleaning the starter slots properly by using cleaning material and re-winding / reassembling the copper wire of same size & same gauge, weight including replacement of parts/components & testing complete all as specified and as directed by Engineer-in-charge. Note:- (i) Defective spare parts (except bronze bushes) shall be measured & paid seprately under respective item of this schedule |
| 185 | Dismantling & removing burn out submersible motor winding of capacity 45 HP pump set taking out the rotor from the body and cutting the burnt coils / winding, cleaning the starter slots properly by using cleaning material and re-winding / reassembling the copper wire of same size & same gauge, weight including replacement of parts/components & testing complete as specified and directed by Eng-in- Charge. Note:- Replacement of parts / components shall be measured and paid separately under respective item of Schedule 'A' . |
| 186 | Dismantling of complete assembly of submersible pump and supply and fixing following parts as per matching requirements of submersible pump complete all as specified and directed. (a) Thrust bearing/thrust plate for submersible pump set. (b) Motor housing bush (GM). (c) Impeller bronze suitable for submersible pump set.(d)Sand Guard and water seal. (e) Bowl packing. (f) Impeller shaft sleeves. (g) Impeller shaft (SS).(h) Bowl bush (GM). (i) Neckring (GM)(j) SS Coupling (k) Stud |
| 187 | S&F in replacement 25 Sqmm 3 Core submersible cable flat copper conductor all as specified and directed. |
| 188 | S&F in repirs star delta starter, fully automatic, 3 phase 440V including overrelay 48-65 amp rating fully automatic with enclosures for 45 HP capacity complete alll specified and directed. |
| 189 | S&F in repairs chlorination Dozing pump single phase electrically operated 230 volts , 50 HZ ,fuse 1 amp with plastic suction and delivery piping solution tank maxm output 4.0 LPH Make -Unichlor of model no- UC-11,Sl no-60365 or equivlent of Avon of sepcified make in PS |
| 190 | M & L For Cleaning of over head tank of capacity 1 lakhs gallon of staging 22 mtr height with scrubing on wall/ floors with stell brushes, removing of sludge, sand and washing with fresh water and bleaching powder adequarte time and removing the same through wash out pipe including and painting the date of cleaning of tank ,cleaning of valve pits complete all as specified and directed. |
| 191 | All as per above item but for UG static water tank complete all as specified and directed at site complete all as specified and directed. |
| 192 | M&L for collection samples of water from wells (pump house) located at 4 AFSB and carry out chemical and bactirilogical testing of water and submission of report all as specified and directed . Particular of test to be carried out (a) PH(b) odour© Taste (d) TDS (e) turbidity (f) total Hardness (g) sulphate (h) chloride (j) Resdiual free chlorine (k) M P N coliform bacteria (Note : Testing shall be got by Govt agency) |
| 193 | Supply and fixing in repairs of CI Non return ( Reflux) valve with GM working parts IS-5312 incl material & labour for drilling and machining, both ends flanged including jointing with rubber gasket , bolts, nuts , washer etc complete all as specified and directed by Engr-in-charge for following size incl taking down old valve. Make- Kirloskar, Leader,Ramco, Upadhaya & IVC. (a) 150 mm bore |
| 194 | M & L in repairs for CI iron fitting (any type & any radius/angle) such as bend tee, connecting pieces., tapers ,Double branch (cross collar cap and any type of end reducer Y -junction (all sockets and spigots)etc complete for pipe upto 150 mm dia normal complete as specified and directed. |
| 195 | All as above item but fixing only complete all as specified and directed at site |
| 196 | M&L Opening of leakage joints in 150mm bore CI pipe line and taking out lead joints by burning /melting incl supplying and refilling the lead points caulking incl excavation & earth work upto 0.9 mtr depth, complete all as specified and directed. (Note: old lead shall be reused again) |
| 197 | M&L Opening of leakage joints in 80 mm bore CI pipe line and taking out lead joints by burning /melting incl supplying and refilling the lead points caulking incl excavation & earth work upto 0.9 mtr depth, complete all as specified and directed. (Note: old lead shall be reused again) |
| 198 | M&L Opening of leakage joints of 50 mm bore of Gl pipe and taking out unserviceable part like union tee elbow etc with provisioning of new materials complete all as specified and directed. |
| 199 | All as per above item but 40 mm bore, complete all as specified and directed. |
| 200 | All as per above item but 25 mm bore, complete all as specified and directed. |
| 201 | All as per above item but 20 mm bore, complete all as specified and directed. |
| 202 | S & F in replacement of cast iron sluice valve of 150 mm bore with flanged end with stainless steel spindle, cast iron body bonner wedge, stuffing box, galvanized thrust plat, wedge body seal ring band plate, and Cl wheel class PN 1.6 inc rubber gasket nuts bolts and washer ISI marked conforming to IS 14848 (2000), complete all as specified and directed. |
| 203 | S & F in replacement of cast iron sluice valve of 80 mm bore with flanged end with stainless steel spindle, cast iron body bonner wedge, stuffing box, galvanized thrust plat, wedge body seal ring band plate, and Cl wheel class PN 1.6 inc rubber gasket nuts bolts and washer ISI marked conforming to IS 14848 (2000), complete all as specified and directed. |
| 204 | Taking up worn out cast iron water mains fo 150 mm bore (Including all fittings) with spigot & Socket ends and lead joints inluding burning out joints and recovering lead complete all as complete all as directed. |
| 205 | Taking up worn out cast iron water mains fo 80 mm bore (Including all fittings) with spigot & Socket ends and lead joints inluding burning out joints and recovering lead complete all as complete all as directed. |
| 206 | Supply and lay/Joint cast iron pipe of 150 mm bore complete all as specified and directed at site sizes with both side flanged heads centrifugally cast class \\"LA\\" in any length laid in treches ISI marked all as specified and directed and taking out old one complete all as specified and directed. |
| 207 | Supply and lay/Joint cast iron pipe of 80 mm bore complete all as specified and directed at site sizes with both side flanged heads centrifugally cast class \\"LA\\" in any length laid in treches ISI marked all as specified and directed and taking out old one complete all as specified and directed. |
| 208 | M & L for run lead joints for CI water main pipe 150/200 mm dia complete all as specified and directed at site |
| 209 | M & L for run lead joints for CI water main pipe 80 mm dia complete all as specified and directed at site |
| 210 | Taking up GI steel water tubing 20 mm bore from the tranches by necessary excavation or on wall / laid under floor/ ceilings with complete fittings,any grade complete all as specified and directed. ( Note:- excavation and earth work shall be measured and paid separately.) |
| 211 | All as per above item but 25 mm bore |
| 212 | All as per above item but 40mm bore |
| 213 | All as per above item but 50mm bore |
| 214 | Supplying and laying steel water tubing 20 mm bore medium grade galvanised with all fittings like bend, tees socketes union etc. as required laid in trenches/ or on wall / laid under floor/ ceilings complete all as specified and directed. |
| 215 | All as per above item but 25 mm bore |
| 216 | All as per above item but 40mm bore |
| 217 | All as per above item but 50mm bore |
| 218 | Supply and fix in replacement gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipes suitable for 20 mm bore dia of pipe complete all as specified and directed. |
| 219 | All as per above item but 25 mm bore |
| 220 | All as per above item but 40mm bore |
| 221 | All as per above item but 50mm bore |
| 222 | M&L for painting of valvle pit cover of MS sheet of size n exc 0.9 * 0.9 m with twi coat of blue synthetic enameled paint internally & externally including preparation of surface complete all as specified and directed |
| 223 | M&L Cutting of Cast iron pipes of 150 mm bore in position for insertion of new tees, branches etc including diverting due to residual water in pipes complete all as specified and directed by EIC. |
| 224 | M&L Cutting of Cast iron pipes of 80 mm bore in position for insertion of new tees, branches etc including diverting due to residual water in pipes complete all as specified and directed by EIC. |
| 225 | M&L in repairs for straight plain brass ferrules ( or connecting screws) screwed both ends and fixed for 20 mm diameter GI tube complete all as specified and directed. |
| 226 | M&L in repairs for straight plain brass ferrules ( or connecting screws) screwed both ends and fixed for 25 mm diameter GI tube complete all as specified and directed. |
| 227 | S&F 40 mm dia brass ferrules screwed both end for iron pipe complete all as specified and directed. |
| 228 | S&F 50 mm dia brass ferrules screwed both end for iron pipe complete all as specified and directed. |
| 229 | S& F in repairs chromium plated fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15 mm dia pipe complete all as specified and directed |
| 230 | S&F in repair bib tap standard of PTMT any colour high pressure screwed for iron pipes 15 mm dia (Minimum weight 90 gms) complete all as specified and directed. |
| 231 | S&F in replacement MS ERW pipe 150mm bore size, including taking up the old one complete all as specified and directed. |
| 232 | S&F in replacement MS ERW pipe 80mm bore size, including taking up the old one complete all as specified and directed. |
| 233 | Excavation of earth on the depth of nearly 0.90 m deep and making clear space of approximately 1 RM at both way for repair of 150/80 mm CI pipe leakage, refilling of pig lead, caulking properly from all side and ensuring leakage prevention complete with making good to disturbed surfaces all as specified and directed. |
| 234 | Excavation in tranches n.exc. 1.5 m deep and n.exc.1.5 m wide in any type of soil and forming bottom surfaces to required level of slope for laying of pipes complete all as specified and directed. |
| 235 | Returning filling in including spreading leveling watering and well ramming in layers n. exc. 25 cm complete all as specified and directed. |
| 236 | Removal surplus soil at a distance n. exc. 50 m and deposited where directed at a lavel not exc. 1.50 m above the starting pont complete all as specified and directed. |
| 237 | M & L for Cleaning of upto 200mm dia size borewell for removing accumulated silt, clay, sand, and bacterial blockages to restore water flow desired pressure. This is typically achieved using high-pressure air compressors (airlifting) of min 250 psi, specialized submersible cleaning pumps, or chemical treatments (like mild acids for encrustation by High-pressure air is pumped into the borewell using heavy-duty compressor machines. The high-pressure air forces the sludge, mud, and accumulated sand up and out of large volume of debris from the well. Note : Taking out Submersible Pump/Motor from borewell and Lifting bore pipe from bore hole of Pump Houses and after cleaning Re-instaltion & lowering in Original Position and Re-connection in water supply installation(starter/panel) and Testing complete are including in quoted rate. |
| 238 | S & F for demolition of old U/S valve chamber and construction of new valve chamber of size 1m x 1m x 1 mtr or 0.75 x0.75 x0.75'mtr with brick work comprising the following items complete all as specified and directed.(a) 150 MM thick PCC foundation (1:2:4) type B2 40 MM graded aggregrate.(b) Brick construction with (1:6) cement mortar and rendering 15 mm thick externally and internally complete fair face of brick works surface in cm (1:4). (c) MS cover of thickness 4 mm double door type welded to angle of size 40 x 40 x 5 mm embedded in cement coping in PCC (1:2:4) tye B-0 wirh anchor fastner including locking arrangment complete with two coat of heighly corresive resistant apoxy point over one coat of red oxide primer. |
| 239 | Demolition of cement concrete (unreinforced) in ground floors and roof and paving not exceeding 15 cm thickness (below or above ground level) .complete all as specified and directed |
| 240 | All as per item here in above but in RCC ( reinforcement cut as required to facilitate demolition) complete all as specified and directed |
| 241 | M&L for Precast RCC 1: 2:4 type B1 (nominal mix ) using 20mm graded stone aggregates as in drain/MH cover slab etc complete all as specifide and directed . |
| 242 | S&F10mm diaTMT bars cut to legth, bent to shape required including cranking bending spirally for hooping for slab for manhole etc complete all as directed. |
| 243 | M&L plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate in surface channels and drains complete all as specified and directed |
| 244 | M&L plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping complete all as specified and directed |
| 245 | Extra for forming fair finished drain or channel up to 30 cm inner girth in cement concrete using extra cement incl forms, moulds, mitred/stopped ends etc. |
| 246 | M&L for 40mm thick cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in floor / paving laid in panels, surface finished even and fair without using extra cement complete all as specified and directed. |
| 247 | M&L 75 mm PCC (1:2:4 ) type B2 using 40 mm graded aggregate as in floors,hard standing, sub base floor finished the surface even and smooth without using extra cement and spike rolling to surface or making impressions of expanded metal whilst the concrete is green.. |
| 248 | M&L 75 mm PCC (1:4:8 ) type D2 using 40 mm graded aggregate as in sub base floor . |
| 249 | M&L in repair for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with gray cement and no pigment ,complete all as specified including 25 mm sand cutioning complete all as specified and directed |
| 250 | Refixing only machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm/ 80mm thickness complete all as specified including 25 mm sand cutioning. |
| 251 | M&L for coloured chequered cement concrete tiles glossy type 200x200x25 mm/ 300 mmx300mmx20 to 25 mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 20 mm thick cement screed bed in CM (1:6) complete all as specified and directed. |
| 252 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 253 | Dismantling stone slab & tiles of any description laid bedded and pointed in any mortar complete all specified and directed |
| 254 | S&F 20 mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like 20 mm cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite. |
| 255 | Rounding to edge of stone slab one edge, such on in stop, cooking plateform, and other similar situation complete all as specified and directed. |
| 256 | S&F in repair 610 mm dia punchhed tape concertina coil (effectve dia 550mm at stretch iength of coil 6 m) two hendle and spikes at bot ends of ends of coil with dove tail clipes (18 SWG ) including razor wire (07 No) 6m length in each wire width medium size ,barbed length 20 mm and barbed 14mm inclucding 51 pins 128 No of clips in each coil inluding 230 gm / sqm Zinc coating on core ire complete all as spd and directed. |
| 257 | M&L for spot welding in repairs not exc 2.5cm in length exc 6mm but n.exc 9mm thick complete all as specified and as directed. |
| 258 | Dismantling mild steel work of any description not otherwise provided for any position complete all specified by Engineer-in-Charge. |
| 259 | M&L preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 260 | M&L for MS angle iron post flat, square/pipe tube, round bar such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, post gate, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work and struts in fencing including cutting tops to shape as directed, drilled holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting screws, etc and similar work complete all as specified |
| 261 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 262 | Demolition of brick work built in cement mortar or cement lime mortar complete all as specified and directed |
| 263 | M&L Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:4 brick work use only drain work for catered complete all as specified and directed |
| 264 | All as per Item here in above but except bricks. |
| 265 | M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) brick work use only drain work for catered complete all as specified and directed |
| 266 | Taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed |
| 267 | M&L Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed |
| 268 | M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed |
| 269 | M&L for Preparation of old plaster surfaces of wall and applying two coat of White washing complete all as specified and directed. |
| 270 | M&L for Preparation of new plaster surfaces of wall and applying three coats of White washing complete all as specified and directed. |
| 271 | M&L for Preparation of new plaster surfaces of wall and applying two coats of cement base paint with primer on new surface complete all as specified as directed. |
| 272 | M&L for Preparation of old plaster surfaces of wall and applying two coats of cement base paint complete all as specified as directed. |
| 273 | M&L for preparing of old decorated surfaces and applying one coat of cement based paint on walls complete all as specified and as directed. |
| 274 | Excavation in trenches n.exc 1.5M wide and n.exc 1.5M depth and n.exc 10 Sqm on plan and getting out in any type of soil (for manholes and sewage lines, drain etc.) |
| 275 | Returning filling in including spreading watering and well raming in layer . Exc 25 cm each in loose/soft soil complete all as specified and directed. |
| 276 | Removing excavated material to a distance not exc 50 m and depositing where directed, complete all as specified and directed |
| 277 | Demolition and breaking up 150mm dia drain pipes ( salt glazed ware, AC or reinforced Concrete ) set in cement mortar complete all as specified. |
| 278 | Demolition and breaking up 200mm dia drain pipes ( salt glazed ware, AC or reinforced Concrete ) set in cement mortar complete all as specified. |
| 279 | Concrete bed to 150 mm salt glazed-stoneware drain pipes in PCC 1:4:8 type D2 using 40mm grade stone aggregate including packing under and haunching against the sides of pipe after they are laid and tested for the following :- |
| 280 | Concrete bed to 200 mm RCC Np-2/ drain pipes in PCC 1:4:8 type D2 using 40mm grade stone aggregate including packing under and haunching against the sides of pipe after they are laid and tested for the following :- |
| 281 | S&F 150 mm bore of salt glazed-stoneware drain pipes laid in trenches and jointed complete all as specified and directed. |
| 282 | S&F Reinforced conctrete 200mm bore of pipes class NP2, laid and jointed complete with collars all as specified and directed :- |
| 283 | Cutting into existing manholes for connecting new drains and making good to pipe and rendering cutting out existing bending for and forming branch channel in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for pipe 150mm bore complete all as specified and directed. |
| 284 | De-silting of sewer line 150/200mm dia with mechanical device like super sucker machine, high pressure jetting machine/gantry machine or any other mechanical device & cleaning site all as specified and directed by Engineer-in-Charge. |
| 285 | Material and labour for Cleaning/removal of blockage from bathroom,EWC/IWC (any type), kitchen, WHB and urinals including connected Nahani traps / gully traps/floor traps, grating of trap, waste pipes, pipe in any length upto first manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users,including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, including removing of all wastes, solid or liquid sludge and depositing the sludge in a pit (at empty/open area) of suitable size at a distance exceeding 50 metres from the building where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified andas directed .(a)Contractor must employ Minimum 2 Nos labourers daily, complete all as specified and as directed .(b)Contractor or his representative shall report daily at 09.00 AM except on Sunday/ National holidays in the office of Engineer-in-Charge/ Complaint cell to receive complaint slip and necessary directions. Complaints received through telephonic message from JE/ Engineer-in-Charge shall also be attended on the same day and the completion of work shall be reported by 05.00 PM of every working day to JE/ Engineer-in-Charge.(c ) In case of non attedence of complaints by the contractor on the same day, a penalty of Rs 200/- per complaint per day will be recovered from the contractor due complete all as specified and as directed . (d) The cost for all necessary T&P such as green female bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, bleaching powder etc and all other other materials for execution of the work shall be included in the unit rate complete all as specified and as directed .(e)A complaint register shall be maintained by JE and proper record of complaints received and attended with date and time shall be recorded and shall be signed daily by both the parties. Complaint register shall be kept on record of Engineer-in-Charge after completion of work complete all as specified and as directed . |
| 286 | Dewatering of soak wells, sump wells including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the same including site clearance to a distance of 3 metre around complete all as specified and directed. |
| 287 | Cleaning of septic tanks / Manholes including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including the work carried out by mechanically and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including site clearance to a distance of 3 Metre around septic tank complete all as specified and directed for the following capacity :-(a) For Manhole n. exc 1.50m deep. |
| 288 | (b) For Manhole exc 1.50m but n.exc 3m deep. |
| 289 | (c) For septic tank of 25 user capacity. |
| 290 | (d) For Manhole exc 25 to 50 user Capicity |
| 291 | (e) For septic tank of 100 user capacity. |
| 292 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises . |
| 293 | M&L for Non - skid coioured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) set complete all as specified and as specified and directed |
| 294 | S&F Glazed ceramic coloured tiles 350x250x7mm /450x350x7mm thick in skirting dados risers to steps etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles over 10 mm thick cement plaster in cm 1:3 complete all as specified as directed.. |
| 295 | M&L Light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick cement mortar 1:6 bedding. |
| 296 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern, with EWC including p or s trap ,seat cover , including connection to trap /drain and to flushing pipe anti syphonage pipe etc complete including making good floorcomplete all as specified as directed. |
| 297 | S & F in Repair One -piece EWC S with slim seat cover & fittings CONA (CERA Cat Part No-S1013164) or equivalent complete all as specified and directed. |
| 298 | S&F in repair vitreous chaina squating pan orissa pattern size 580X 440mm white with intregal foot rest complete including lime concrete(excl flushing cistern and flush pipe) but connecting to flushing pipe, anti-symphonage pipe etc complete fixed in repair complete all as specified as directed. |
| 299 | S&F in repairs angle valves, 15 mm dia fancy type chromium plated with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed all as specified and directed. |
| 300 | Supply and fix in repairs 15 mm bore bib tap brass chromium plated fancy type with crutch or butterfly handle screwed down, screwed for iron pipe fixed in repairs all as specified and directed. |
| 301 | S&F in repairs 10 Litre capacity PVC low level flushing cistern with ball valve and handle/push button 32mm dia PVC flush pipe including taking down unserviceable cistern complete all as specified and directed. |
| 302 | S&F in repairs 15 mm bore PVC connection 45cm long with brass nuts and washers on both ends all as in repairs specified and directed. |
| 303 | Taking down rain water / vent pipe of any description including fittings etc including removal to store, complete all as specified and directed. |
| 304 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls ,floors, trenches etc complete all specified and directed. |
| 305 | S&Fin repair PVC (SWR) P/s trap 125/110 mm,setting and jointing with solvent cement complete all as specified as directed. |
| 306 | M&L in repair 75mm dia PVC (SWR) floor trap, plane with grating including jointing with solvent cement complete all as specified as directed. |
| 307 | S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed |
| 308 | S&F in repair 75mm PVC (SWR) bends anyradius complete all as specified as directed. |
| 309 | S&F in repair CP Grating 125 mm size complete all as specified as directed. |
| 310 | Supply and fixing PVC (SWR) bends (any radius) 100/110mm complete all specified. |
| 311 | S&F PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified as directed. |
| 312 | Supply and fixing PVC (SWR) Junction single ,(single T) equal or un equal (any radius) 100/110mm complete all specified. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender