Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56428488

Tender For Repair/Replacement Of Led Light Fitting And Connected Items At New Cantt Prayagraj

Issued by Statutory Bodies & Commissions/Committees · Prayagraj, Uttar Pradesh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
18 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Prayagraj → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Led Light Fitting And Connected Items At New Cantt Prayagraj

BOQ

Name of Work:- REPAIR/REPLACEMENT OF LED LIGHT FITTING AND CONNECTED ITEMS AT NEW CANTT PRAYAGRAJ
Sl. No. Item Description
1M&L in replacement of energy saver LED battan fitting 20 Watt 120 Lumen/Watt (cool day/warm white), 230 Volts, single tube mounting including with electronic driver LED Printed board, end cover, connector box etc and accessories, pre-wired, LED including required fixing arrangements and electrical connection two core copper cable from ceiling rose to LED light fitting complete all as specified and directed.
2M&L in replacement of energy saver LED battan fitting 10 Watt, 230 Volts, single tube mounting including with electronic driver LED printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection two core copper cable from ceiling rose to led light fitting complete all as specified and directed.
3S&F in replacement of wall light chrome finish including LED lamp B22 holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
4S&F in replacement of twin arm wall light chrome finish including LED lamp B22 holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
5S&F in replacement of mirror light fancy type flexible neck bronze finish of 12 Watt in built light with connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
6Supply and fixing of a deep recessed/surface down light for comfort on eye suitable for versetile application such as offices retail 6 Watt LED, including driver fixing arrangements & connecting with three core copper cable including taking down old worn out light complete all as specified and directed.
7Description same all as per item No 6 here-in-before but 12 Watt
8Description same all as per item No 6 here-in-before but but 15/20 Watt
9Description same all as per item No 6 here-in-before but 24 Watt
10M&L in replacement of energy saver LED battan fitting 40 Watt, 230 Volts, single tube mounting including with electronic driver LED printed board, end cover, connector box etc and accessories, pre-wired, LED including required fixing arrangements and electrical connection two core copper cable from ceiling rose to LED light fitting complete all as specified and directed.
11M&L in replacement of bracket for building security light made out of 40mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50 x 6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
12S&F in replacement of LED Street Light fitting 35 Watt, 230 Volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
13S&F in replacement of 36 Watt LED, 2'x2' (cool day/warm white) Panel Ultra slim recess mounted LED module with high brightness LED package and unique pattern de-glaring PP diffuser and PS LGP de-glaring diffuser sheet for glare free uniform light distribution suitable for armstrong/grid ceiling applications, complete all as specified and directed.
14S&F of industrial integral high bay luminary LED 150 Watt, 120 Lumen/Watt, 240 Volts complete with LED driver including suitable size of reflector, hanging/ fixing arrangements & connecting with three core copper cable 2.5 Sqmm including taking down old worn out high bay luminary complete all as specified and directed. Make : Philips, Model No. BY15P LED 150 S5700 WB PSU GR or equivalent in make Wipro/Havells
15S&F Angle/Batten type Lamp holder, PVC/Polycarbonate type with back plate suitable for light fittings complete all as specified and directed.
16S&F in replacement of Decorative, wall mounting, fixture with plastic body (City type -1) as per sample approved by Engr-in-charge including 9 Watt LED lamp B22 complete all as specified and directed.
17S&F in replacement of Flexible LED strips with uniform light distribution and long lasting adhesive for perfect cove lighting solution Flexion Neo Led Strip 24 Watt 3000 K/6500K, 5 mtr long with connector etc for ceiling applications complete all as specified and directed.
18S&F in replacement of wall light/spot light 7 Watt including LED light connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed, Make : Havells, Cat Part No LHEEAKPDIE1T007 or equivalent in make Wipro/Philips
19S&F in replacement of step light 5 Watt including LED light connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed, Make : Havells, Cat Part No LHEOAAP5I46H005 or equivalent in make Wipro/Philips
20M&L in replacement of earthing complete with M.S galvanized earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal GL) with top edge of the earth plate not less than 1.5 mtr below normal GL, connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40mm thick reinforced with 8mm dia bar, 3 Nos both way, 15mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20mm dia medium grade, lugs, main Earthing lead upto 7.5 mtr including Charcoal dust, salt etc, all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification, complete all as specified and directed.
21M&L in replacement of provn of earthing complete with M.S galvanized earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal GL) with top edge of the plate not less than 1.5 mtr below normal GL, connected to Galvanized earth strip 32 x 6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40mm thick reinforced with 6 mm dia bar, 3 Nos both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20mm dia medium grade, lugs, main Earthing lead upto 7.5 mtr including Charcoal dust, salt etc all as shown in electrical plate No. 5 of SSR Pt-I 2009 specification, complete all as specified and directed.
22S&F of GI pipe light grade of size 40mm bore for laying in trenches/floors or walls including all fittings for fixing complete all as specified and directed.
23S&F of GI pipe light grade of size 15mm bore for laying in trenches/floors or walls including all fittings for fixing complete all as specified and directed.
24M&L for earth continuity conductor or main earthing lead 4mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe all as required at site, complete all as specified and directed.
25Taking down carefully sub main wiring of any type/size complete with MCB DBs MCB, isolators wooden batten, concealed/surface conduit/casing caping etc, removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified and directed.
26M&L for concealed sub main wiring using FRLS/FRLSH PVC insulated, unsheathed stranded copper conductor cable single core of size 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire of voltage rating upto and including 1100 Volts drawn in and including rigid PVC concealed conduit of dia not less than 20mm dia medium grade with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor as earth continuity conductor complete all as specified and directed. Note : (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required and making good the disturbed surface shall deemed to be included in the quoted unit rate.
27Description same all as per item No 26 here-in-before but of size 2 x 6 Sqmm + 6 x Sqmm earth wire
28Description same all as per item No 26 here-in-before but of size 2 x 10 Sqmm + 10 x Sqmm earth wire
29Description same all as per item No 26 here-in-before but of size 4 x 10.0 Sqmm +1 x 10.0 Sqmm earth wire
30M&L for surface sub main wiring using FRLS/FRLSH PVC insulated, unsheathed stranded copper conductor cable single core of size 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire of voltage rating upto and including 1100 Volts drawn in and including non metallic PVC rigid, medium grade not less than 20mm dia surface conduit / non metallic PVC casing and caping with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor as earth continuity conductor complete all as specified and directed. Note : (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
31Description same all as per item No 30 here-in-before but of size 2 x 6 Sqmm + 6 x Sqmm earth wire
32Description same all as per item No 30 here-in-before but of size 2 x 10 Sqmm + 10 x Sqmm earth wire
33Taking down main switches fuse unit, MCB/Kit kat distribution board any type/size/capacity with steel enclosure along with MCB’s / Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfaces complete all as specified and directed. Note : Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
34S&F in replacement of factory made epoxy polyester powder coated distribution board SP & N 4 way fabricated from recommended thick CRCA sheet with metal double door (IP-43 protection) fixed flush to wall and suitable for universal mounting and including aluminium alloy bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 2 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB complete all as specified and directed. Note : (a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.(c) Making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d) Make of MCBs/MCCBs and MCB DBs shall be same makes.
35S&F in replacement of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from recommended thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including aluminium alloy bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all complete all as specified and directed. Note : (a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.(c) Making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d) Make of MCBs/MCCBs and MCB DBs shall be same makes.
36Supply and fixing in replacement of factory made epoxy polyester powder coated distribution board SP & N 12 way fabricated from recommended thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including aluminium alloy bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP/SPN MCB as incomer and 8 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB complete all as specified and directed. Note : (a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.(c) making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d) Make of MCBs/MCCBs and MCB DBs shall be same makes.
37Supply and fixing in replacement of factory made epoxy polyester powder coated distribution board TP & N 4 way fabricated from recommended thick CRCA sheet with metal double door (IP-43 protection ) door IK 09 fixed flush to wall and suitable for universal mounting and including aluminium alloy bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable MCBs as complete all as specified and conforming to IS: 8623 alongwith cable end box for above TPN/isolator complete all as specified and directed. Note : (a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.(c) making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d) Make of MCBs/ MCCBs and MCB DBs shall be same makes.
38S&F in replacement of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) and double door IK-09 fabricated from recommended thick CRCA sheet and fixed on wall and suitable for universal mounting and including aluminium alloy bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 125 4 pole MCCB as incommer and 16 to 32 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB complete all as specified and directed. Note : (a) MCBs/MCCB shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.(c) Making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d) Make of MCBs/MCCBs and MCB DBs shall be same makes.
39S&F MCB 63 to 100 Amps, TPN, 10 KA, 'C' curve 415 Volts complete all as specified and directed.
40S&F MCB, SPN, 40-63 Amps, 10 KA 'C' curve, 240 Volts complete all as specified and directed.
41S&F MCB Single Pole, 6 to 32 Amps, 240 Volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
42S&F in repair MCB Single Pole 40 to 63 Amps, 240 Volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
43S&F in replacement of MCCB 160 Amps, 4 pole, 36 KA at 415 Volts fixed type with shhet metal enclousre compitable to mount it including all lugs, seprater etc complete all as specified and directed.
44Taking down carefully aluminium/copper point wiring any type for one light, fan, socket power point or buzzer controlled by one switch complete including fitting/fixtures such as switches, ceiling roses, holder, socket, light fitting etc for credit and making good disturbed surfaces of walls, ceilings etc complete all as specified and directed.
45M&L for point wiring with FRLS/FRLSH PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 Volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade concealed conduit with all fixing accessories of 20mm dia, and including modular sunken box, cover plate / frame for any module as required at site with all accessories and making good to disturbed conceal surfaces for one light/fan/bell point controlled by one switch complete all as specified and directed. Note : (a) Colour code of wire shall be strictly followed, Red for Phase, Black for neutral and green for earth wire. (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface.(c) Only 04 point shall be allowed is one circuit.
46Description same all as per item No 45 here-in-before but for one point for socket outlet 5 Amps on independent board
47Description same all as per item No 45 here-in-before but for one point for socket outlet 5 Amps on same board
48Description same all as per item No 45 here-in-before but for one light point controlled by two 2-way switches
49Description same all as per item No 45 here-in-before but for one socket outlet 16 Amps on independent board with 4.0 Sqmm cable and 4.0 Sqmm earth wire
50M&L for point wiring with FRLSH PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 Volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade concealed conduit with all fixing accessories of 20mm dia, using new pressed steel sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed conceal surfaces for one light/fan/bell point controlled by one switch, complete all as specified and directed. Note : (a) Colour code of wire shall be strictly followed, Red for Phase, Black for neutral and green for earth wire. (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface
51Description same all as per item No 50 here-in-before but for one point for socket outlet 5 Amps on independent board
52Description same all as per item No 50 here-in-before but for one point for socket outlet 5 Amps on same board
53Description same all as per item No 50 here-in-before but for one light point controlled by two 2-way switches
54Description same all as per item No 50 here-in-before but for one socket outlet 16 Amps on independent board with 4.0 Sqmm cable and 4.0 Sqmm earth wire
55M&L for point wiring with FRLSH PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 Volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC casing and caping/PVC conduit of appropriate size on wall/roof surface with all fixing accessories and polycarbonate modular/modular GI sunken boxs, and modular sunken box, cover plate/frame for any module as required at site with all accessories and making good to disturbed conceal surfaces for one light/fan/bell point controlled by one switch complete all as specified and directed. Note : (a) Colour code of wire shall be strictly followed, Red for Phase, Black for neutral and green for earth wire.
56Description same all as per item No 55 here-in-before but for one point for socket outlet 5 amps on independent board
57Description same all as per item No 55 here-in-before but for one point for socket outlet 5 amp same board
58Description same all as per item No 55 here-in-before but for one light point controlled by two 2-way switches
59Description same all as per item No 55 here-in-before but for one socket outlet 16 Amps on independent board with 4.0 Sqmm cable and 4.0 Sqmm earth wire.
60S&F modular switch 1 way, 6 Amps, 230 Volts AC, one way complete all as specified and directed.
61S&F modular socket out let 2-in-1, 3 pin, 6 Amps flush type 2 module complete all as specified and directed.
62S&F modular switch flush type 16 Amps, 230 Volts AC single pole one way complete all as specified and directed.
63S&F modular socket out let 2-in-1, 3 pin, 5 & 16 Amps flush type 2 module complete all as specified and directed.
64S&F modular switch 2 way, 6 Amps, 230 Volts AC, one way complete all as specified and directed.
65S&F modular bell push flush type 6 Amps, 1 module SP, 230 Volts AC complete all as specified and directed.
66S&F modular fan regulator, 5 stepped, electronic type, single phase, 120 Watt, socket size including connection complete all as specified and directed.
67S&F switch piano flush button single pole one way 6 Amps complete all as specified and directed.
68S&F switch 2 way, 6 Amps, 230 Volts AC, one way complete all as specified and directed.
69S&F socket outlet 5 pin 6 Amps flush type complete all as specified and directed.
70S&F socket out let multipurpose 3 pin 16 Amps and one 3 pin 6 Amps controlled by one switch complete all as specified and directed.
71S&F switch piano flush button single pole one way 16 Amps complete all as specified and directed.
72S&F in replacment of ceiling fan regulator step type 240 Volts AC complete all as specified and directed.
73S&F ceiling rose surface backelite three terminals complete all as specified and directed.
74S&F Call Bell Ding Dong type AC 230 Volts single pole complete all as specified and directed.
75S&F Bell Push flush type 6 Amps, 230 Volts AC complete all as specified and directed.
76S&F in replacment single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amps, 'B' curve complete all as specified and directed.
77S&F in replacement of ventilation fans PVC body of size 250mm sweep including taking down the old unserviceable one and depositing the same in MES Yard for further disposal as per existing procedure complete all as specified and directed.
78S&F in replacement of worn out/rusted sunken box of following sizes with pressed MS/GI steel terminal boxes of depth not less than 50mm, flush type of thickness lot less than 1.22mm of size 100mm x 100mm along with new 3 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete all as specified and directed.
79Description same all as per item No 78 here-in-before but of size 175mm x 100mm.
80Description same all as per item No 78 here-in-before but of size 250mm x 200mm.
81S&F in replacement three pin metalic socket outlet suitable for sheet metal enclosure, complete all as specified and directed.
82S&F in replacement three pin metallic plug top suitable for sheet metal enclsoure, complete all as specified and directed.
83S&F in replacement of condenser of 2.5 Mfd, 240 Volts AC, conforming to IS-1709 suitable for fans complete all as specified and directed.
84Schedule of Credit (MINUS) Rs. 71,247.00 B/F from Serial Page No. ____ [Note : Details of items for Sch of credit is given on Serial Page No. ____] This amount shall be automatically deducted to arrive at tendered sum Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56428488
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 01-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Led Light Fitting And Connected Items At New Cantt Prayagraj
Basic Detail
Tender No 8961/E8
Bidding Type Tender
Location
City Prayagraj
State Uttar Pradesh
Key Dates
Publish Date 11 Jul 2026
Submission Date 01 Aug 2026
Open Date 08 Aug 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
0e6dd953-0ee6-4dd4-809f-bc993feb301d.html
BOQ_871336.xls
TenderDocus8961.pdf
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

0e6dd953-0ee6-4dd4-809f-bc993feb301d.html

xls

BOQ_871336.xls

pdf

TenderDocus8961.pdf

pdf

Tendernotice_1 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders