Bids Are invited for Electrical Spares
Tender Overview
Project Description
Bids Are invited for Electrical Spares Boq1 - Hydraulic Bearing Puller 12 Tone , Boq2 - Digital Earth Leakage Relay , Boq3 - Rectifier Unit For 11Kv Switch. 110V,Ac-Dc , Boq4 - Single Phase Preventer For Star Delta Stater No -9, Storage Temp - 20 Degree-85 Degree Celcius, Opening Temp - 15-80 Degree C , Boq5 - Isolator 400 . 3.3 Kv Complete Ambient Temp - 10 - 60 Degree C 100 M Consumption - 20 Va (Max) , Boq6 - Breaker Circuit Mccb 630 . 415 Volt 3 Pole, W/ Suitable Breaking Capacity 85 Ka , Boq7 - Auxiliary Tripping Relay For 11Kv Ht Switch , Boq8 - Lt Voltage Detector , Boq9 - Breaker Circuit Mccb 800 , Boq10 - Silicon Rubber Compound 3.3Kv / 6.6 Kv Isi Mark Dietextoic Strength 18-25 Kv Mm Or Higher Tensile Strength 5-10 Mpc , Boq11 - Crimper Hyd. 25-400Mm2 , Max Crimping Cap- 500Mm2, Crimping Std, 1 Pc/Wamaa- 920 Type Of / Die Multi (Quatd , Hexa, Octal) Complete Set , Boq12 - Breaker Circuit Mccb 800 . 550 Volt 4 Pole, W/ Suitable Breaking Capacity 90 Ka , Boq13 - Breaker Circuit Mccb 200 . 550 Volt 4 Pole, W/ Suitable Breaking Capacity 90 Ka , Boq14 - Indicating L Led Type - 12V Ac Minimum Illumination 300 Lvx , Boq15 - Push Switch / Test Reset Switch Of 400A, Switch. (Operating Temp - 20 To 95 Degree Celcius) , Boq16 - Vcb Shunt Trip Coil 110 V, Frequency - 100 Hertz Current 11-15 , Boq17 - Crimping Tool With Die 25 Sq Mm To 400 Sq Mm, Max Crmping Capacity -500 Mm2, Capacity Standard- I Pc / Whmaa -920 Type Of Die Multi (Hexa, Octagonal Etc) , Boq18 - Single Phase Preventer For Star Delta Stater , Boq19 - Coil Mnx 650 A 415 V Frequency , Boq20 - Indicating L Led Type Life Of L 2000Hrs Minimum Illumination 300 Lux , Boq21 - Vaccum Interputer 11Kv , Boq22 - Kit Spare Mnx 400 Minimum Rated Short Curcuit Breaker Capacity 160Ka Rms Or Equivalent , Boq23 - Power Contractor 3 Phase , 550 Volts Mnx 400 . Complete Set, 2No + 2Nc, Or Equivalent Ambient Temprature (Operation) 25 To 95 Degree Celcious , Boq24 - Rubber Coupling Bush , Boq25 - Coupling Bolt Nut Size 16Mmx 100Mm, Grade Ht Astma 25A Mb 13 For Use In 4000 Gpm Pumps , Boq26 - Ht Bolt Size 30Mm X 100 Mm, Grade Ht Astma254 Mb13 For Use In Baseplate Of Pumps , Boq27 - Discharging Rod Extendable Up To 12 Mtr. Of Fiber Glass, Copper Fitted Wire Up To 12 Mtr. Rubber Insulation In Last And Middle With 3.3 Kv Grade. With Test Certificate , Boq28 - Safety Belt Comp. Isi Marked Full Body Harness Safe Drop 1.8 Mtr. Longrope With Hook & Spring , Boq29 - Insulation Tester Digital Meggar Tester Type Digital Megger Measurement Range 5 Kv, Dc Voltage Accuracy - 0.01 Percent , Ac Voltage Accuracy - 0.01 Percent ,Dc Current And Accuracy - 0.01 Percent , Ressistance Accuracy 0.02 Percent, Temprature Rabge 50 Degree To 500 Degree Celcious , Boq30 - Detector Wnding Tmp 0-150 C 250Vac/110V Dc Rated Frequency 80 Hz , Boq31 - Thermometer Type Oil Temperature Measuring Std Temp 300 Degree Celsiou Storage Temp 0 -70 Degree Celsius, Assembly Standard Ressistance 300 Ohm Measuring Temp- 0-450 Degree Celsious , Boq32 - Isolator 400 . 3.3 Kv Complete 400A Reverse Forward Isolator Assy Typer Ambience Temp 0-70 Degree Celsious Power Consuption 1Va Max , Boq33 - Breaker Circuit Mccb 100 . 415 Volt 4 Pole, W/ Suitable Breaking Capacity 90 Ka , Boq34 - Breaker Circuit Mccb 630 . 415 Volt 4 Pole, W/ Suitable Breaking Capacity 90 Ka , Boq35 - Ht Line Tester , 11Kv Operating Temparature 0 Degree Celsious - 65 Degree Celsious Operating Humidity 95 Percent Total Quantity : 437
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | BOQ1 | Hydraulic Bearing Puller 12 Tone |
| 2 | BOQ2 | Digital Earth Leakage Relay |
| 3 | BOQ3 | Rectifier Unit for 11KV Switch. 110V,AC-DC |
| 4 | BOQ4 | Single Phase Preventer for Star Delta Stater No -9, Storage Temp - 20 Degree-85 Degree Celcius, Opening Temp - 15-80 Degree C |
| 5 | BOQ5 | Isolator 400 Amp. 3.3 KV Complete Ambient Temp - 10 - 60 Degree C 100 M Consumption - 20 VA (Max) |
| 6 | BOQ6 | Breaker Circuit MCCB 630AMP. 415 VOLT 3 POLE, W/ Suitable Breaking Capacity 85 KA |
| 7 | BOQ7 | Auxiliary Tripping Relay For 11KV HT Switch |
| 8 | BOQ8 | LT Voltage Detector |
| 9 | BOQ9 | Breaker Circuit MCCB 800AMP |
| 10 | BOQ10 | Silicon Rubber Compound 3.3KV / 6.6 KV ISI Mark Dietextoic Strength 18-25 KV mm or Higher Tensile Strength 5-10 MPc |
| 11 | BOQ11 | Crimper Hyd. 25-400mm2 , Max Crimping Cap- 500mm2, Crimping Std, 1 Pc/WAMAA- 920 Type of / Die Multi (Quatd , Hexa, Octal) Complete Set |
| 12 | BOQ12 | Breaker Circuit MCCB 800AMP. 550 VOLT 4 POLE, W/ Suitable Breaking Capacity 90 KA |
| 13 | BOQ13 | Breaker Circuit MCCB 200AMP. 550 VOLT 4 POLE, W/ Suitable Breaking Capacity 90 KA |
| 14 | BOQ14 | Indicating Lamp LED Type - 12V AC Minimum illumination 300 LVX |
| 15 | BOQ15 | Push Switch / Test Reset Switch of 400A, Switch. (Operating Temp - 20 to 95 Degree Celcius) |
| 16 | BOQ16 | VCB Shunt Trip Coil 110 V, Frequency - 100 Hertz Current 11-15 amp |
| 17 | BOQ17 | Crimping Tool With Die 25 Sq MM TO 400 SQ MM, Max Crmping Capacity -500 mm2, Capacity Standard- I Pc / Whmaa -920 Type of Die Multi (Hexa, Octagonal etc) |
| 18 | BOQ18 | Single Phase Preventer for Star Delta Stater |
| 19 | BOQ19 | Coil MNX 650 A 415 V Frequency |
| 20 | BOQ20 | Indicating Lamp LED Type Life of Lamp 2000hrs Minimum Illumination 300 Lux |
| 21 | BOQ21 | VACCUM INTERPUTER 11KV |
| 22 | BOQ22 | KIT SPARE MNX 400 AMP Minimum Rated Short Curcuit Breaker Capacity 160KA RMS or Equivalent |
| 23 | BOQ23 | POWER CONTRACTOR 3 Phase , 550 Volts MNX 400 Amp. COMPLETE SET, 2NO + 2NC, or Equivalent Ambient Temprature (Operation) 25 to 95 Degree Celcious |
| 24 | BOQ24 | Rubber Coupling Bush |
| 25 | BOQ25 | Coupling Bolt Nut Size 16mmX 100mm, Grade HT ASTMA 25A MB 13 for use in 4000 Gpm Pumps |
| 26 | BOQ26 | HT Bolt Size 30mm X 100 mm, Grade HT astma254 mb13 for use in baseplate of Pumps |
| 27 | BOQ27 | Discharging Rod Extendable up to 12 Mtr. of Fiber glass, Copper fitted wire up to 12 Mtr. Rubber insulation in last and middle with 3.3 KV Grade. With Test Certificate |
| 28 | BOQ28 | Safety Belt Comp. ISI Marked Full Body Harness Safe Drop 1.8 Mtr. LongRope With Hook & Spring |
| 29 | BOQ29 | Insulation Tester Digital Meggar TESTER TYPE DIGITAL MEGGER MEASUREMENT RANGE 5 KV, DC Voltage Accuracy - 0.01 Percent , AC Voltage Accuracy - 0.01 Percent ,DC current and Accuracy - 0.01 Percent , Ressistance Accuracy 0.02 Percent, Temprature Rabge 50 Degree to 500 Degree Celcious |
| 30 | BOQ30 | DETECTOR WNDING TMP 0-150 C 250VAC/110V DC rated Frequency 80 HZ |
| 31 | BOQ31 | THERMOMETER TYPE OIL TEMPERATURE MEASURING STD TEMP 300 Degree Celsiou Storage Temp 0 -70 Degree Celsius, ASSEMBLY STANDARD RESSISTANCE 300 OHM Measuring Temp- 0-450 Degree Celsious |
| 32 | BOQ32 | Isolator 400 Amp. 3.3 KV Complete 400A Reverse Forward Isolator Assy Typer Ambience Temp 0-70 Degree Celsious Power Consuption 1VA Max |
| 33 | BOQ33 | Breaker Circuit MCCB 100AMP. 415 VOLT 4 POLE, W/ Suitable Breaking Capacity 90 KA |
| 34 | BOQ34 | Breaker Circuit MCCB 630AMP. 415 VOLT 4 POLE, W/ Suitable Breaking Capacity 90 KA |
| 35 | BOQ35 | HT LINE TESTER , 11KV Operating Temparature 0 Degree Celsious - 65 Degree Celsious Operating Humidity 95 Percent |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender