Tender For Repair Replacement To Lt Panels Circuit Breakers And Other Connected Works At Afac Under Age ( I) (Af) Coimbatore.
Tender Value
14.50 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
20 days left
EMD
29000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Replacement To Lt Panels Circuit Breakers And Other Connected Works At Afac Under Age ( I) (Af) Coimbatore.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out in hard/dense soil for laying of UG cables/taking out cable covers all as specified and as directed. Note : During the time of excavation any damge in existing structure/pipes/cables the contractor rectify the same without any extra cost |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thickness with hard/dense soil all as specified and as directed. |
| 3 | Removing excavated materials (soils) to a distance not exc 50m and depositing where directed at a level not exc1.5 m above the starting point all as specified and as directed. |
| 4 | Earth cushioning to UG cables using excavated soil riddled by using large sieve to separate the composite particles/roots etc and refilling in trenches all as specified and as directed. Notte: Punned thickness will be measured for payment. |
| 5 | Supply and lay reinforced precost concrete cable cover class LV type 1 flat size 250 x 180x 40 mm all as directed. |
| 6 | Relaying reinforced precost concrete cable cover class LV type 1 flat size 250 x 180x 40 mm obtained durinbg excavation all as directed. |
| 7 | Supply, layig, connecting, testing and commissioning of 185 Sqmm 3.5 Core under ground LT cable XLPE insulated screened, PVC bedded, armoured heavy duty electric cable confirming to IS : 7098-1985 with stranded aluminium conductor 1100 volts laid in trenches, floor, fixed to walls/drawn through pipe, duct or along the pole and incl the disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, crimping type lugs etc all as specified and directed. Make: Havells/Polycab/Finolex/Paragon/Gloster/Nicco |
| 8 | All as per item No 7 above but 3.5 core 120 Sq mm |
| 9 | All as per item No 7 above but 3.5 core 95 Sq mm |
| 10 | All as per item No 7 above but 3.5 core 50 Sq mm |
| 11 | All as per item No 7 above but 3.5 core 25 Sq mm |
| 12 | M&L for dismantling / cutting of existing road / path / hard standing cement concrete/kotastone floor with the help of cuter/drilling machine (unreinforced) in ground floors and pavings n.exc 70 cm thickness (below or above ground level) suitable for laying cable /protection pipe any size and making the cable duct as required size and brick/PCC masonary work and plaster of wall floor etc at site after cutting work and made the duct with proper finish and layout at sub stations all as directed. |
| 13 | Material and labour for PCC (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) for making good the disturbed surface of road/path/hard standing by using cement contrete mortar 1:2:4 type B1, using 40 mm graded stone aggregate 0.45 mtr wide and 0.15 mtr thick complete all as specified and directed. including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge. |
| 14 | Supply and fill river sand/M sand in cable duct without distrurb the existing cables all as directed |
| 15 | Labour for removing old sand and debiries from cable duct and removing and deposited where diorected with disturb the exsiting cable and relaying the cable on same duct properley including necessary excavation earth work where necessary (outside of sub station) for realign the cable and looping the cable properly with out damage in existing cable all as directed Note:(i) Approx size of duct is 5.0x 0.6 x 0.9 mtr (ii) Excavation earthwork paid and mmeadured separately |
| 16 | Supply, Installing, testing and commissioning, CPRI approved indoor type LT feeder pillar box of minimum size 1.6 x 1.2 x 0.45 indoor floor/stand mounting type suitable for 415V, 3 Phase, 4 wire, 50 Hz, AC supply system fabricated from CRCA sheet totally enclosed, dust, weather & vermin proof, front & back openable, double door system lockable / openable by keys from both sides having pattern fancy locks stainless steel in opening handle with louvers & air vent gasket for natural flow of air, the bottom of the outer shell contains a detacheable plate having provision for entry of adequate size with glands, 2.0 mm thick for outer shell and 1.6/2 mm thick for inner shell and partion having TPN aluminium busbars of rating 1.5 times that of incoming MCCB supported on SMC insulators with short circuit withstand capacity 35 MVA for 1 second, bottom C type base channel of MS section not less than 100 mm, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 nos earth stud, solid bus bar connections from main bus bar to switchgears with required size and contrrol wiring with minimum 1.5 Sqmm FRLS insulated copper conductor wire, cable alleys, cable gland plates for Indicating lamp LED type, CT, selector switch, multifuction digital energy meter. The energy meter having to measure voltage, current, PF KWH, KVAH, KVARH (Make - Secure / L&T / C&S / Schneider / Legrand), general construction confirming to IS : 8623 / 93 and mounted on suitable PCC foundation with followiing detailed specifications & controls and taking down the old panel board including disconnecting/reconnecting of all incoming and outgoing cable with new cable glande :- (Make - CPRI approved/certified manufacture) (a) The size of panel is suitable to accomodate 01 (one) Nos Incoming MCCB and 04 (Eight) Nos MCCB outgoings. and 04 Nos MCB out going Note : (i) The PCC/Brick work and plaster work required at site for panel erection and PCC foundation included in quated rate. (ii) Each MCCB's having seperate enclosures, marking with feeder name (iii) Switch gear's (MCCB,MCB,ACB, Changeover, timer switch, contactor fixing charges only included in quated rate) will be measure and paid seperately under relevent items . (v) Earth work excavation, returing filling, removel for panel erection and cabling connection included in quated rate |
| 17 | All as per item No 16 above but out door type floor/stand mount type minimum size is 1.6 x 1.2 x 0.45 mtr sheet thickness 3.15 mm in outer shell and indoor shell/partion is 1.6/2 mm thick suitable to accommodate is 01 Nos incomming MCCB and 4 Nos out gouing MCCB and 4 Nos out going MCB all as directed. |
| 18 | Supply only MCCB 400/320 amp four pole with thermal magnetic relese braking capacity 35/36 KA thermal relese range 320 to 400 amps all as directed - 01 (one) No, (Make : L&T, Havells, Indoasian, Legrand, C&S). |
| 19 | All as per above but MCCB capacity 200 to 250 Amps relay range 200 to 250 amps |
| 20 | Supply only MCCB 250 amp four pole with thermal magnetic relese braking capacity 25 KA thermal relese range 200 to 250 amps all as directed (Make : L&T, Havells, Indoasian, Legrand, C&S). |
| 21 | All as per above but MCCB capacity 200 Amps relay range 160 to 200 amps |
| 22 | All as per above but MCCB capacity 160 Amps relay range 125 to160 amps |
| 23 | All as per above but MCCB capacity 63/100 Amps relay range 63 to 100 amps braking capacity 18KA |
| 24 | MCB TPN 32 Amp \\"C' Series of breaking capacity 10 KA, ISI marked. (Make : L&T, Havells, Indoasian, Legrand, C&S). |
| 25 | All as per Item No 24 here in before but TPN MCB 63 Amp, |
| 26 | Supplay and fix mild steel steel angles tees, chanels, nut bolts/washers for making the panel board mounting stand of requird size and chequred sheet of five milimeter thick using as a duct plate of required size at ste with cutting/welding , drilling holes for flush type handle in any size and shape fabricated in any size and shape as directed by the Engr -In - charge including taking down the old PCC/RCC duct covers any type and shape and removing from site Note (i) The maximum length of duct plate is not exceeding one meter (ii) Provide flush type handles on both side of the plate all as directed (iii) Size of panel mount stand and thickness as directed by Engr -In - Charge Please Enable Macros to View BoQ information |
| 27 | Supplay and fix mild steel steel angles tees, chanels, nut bolts/washers for making the panel board mounting stand of requird size and chequred sheet of five milimeter thick using as a duct plate of required size at ste with cutting/welding , drilling holes for flush type handle in any size and shape fabricated in any size and shape as directed by the Engr -In - charge including taking down the old PCC/RCC duct covers any type and shape and removing from site Note (i) The maximum length of duct plate is not exceeding one meter (ii) Provide flush type handles on both side of the plate all as directed (iii) Size of panel mount stand and thickness as directed by Engr -In - Charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender