Tender For Construction Of 03 X Bathroom & 03 X Toilet Block For Gents Offrs At Offrs Mess And Ta Lady Offr At 801 Engr Regt R&P (Ta) And Provn Of Drainage System At Trg & Adm Area At 411 (I) Para Fd Coy Under Ge (East) Agra
Tender Overview
Project Description
Tender for Construction Of 03 X Bathroom & 03 X Toilet Block For Gents Offrs At Offrs Mess And Ta Lady Offr At 801 Engr Regt R&P (Ta) And Provn Of Drainage System At Trg & Adm Area At 411 (I) Para Fd Coy Under Ge (East) Agra
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Surface dressing n exc. 15 cm deep in soft/loose soil complete all as specified and directed. |
| 2 | M&L for Excavataion in trenches width not exceeding 1.5mtr and depth not exceeding 1.5metre for foundations, not exceeding 10 Sqm on plan for manholes etc and getting out in soft/disintegrated rock, complete all as specified and directed. |
| 3 | M&L for Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 4 | Returning, filling in , including spreading, levelling,watering and well ramming in layers not exceeding 25 cms in soft/loose soil complete all as specified and directed. |
| 5 | M & L for Cement concrete (1:4:8) type D-2 (40 m graded broken stone aggregate ) as in foundation complete all as specified and directed. |
| 6 | M&L for Reinforced Cement Concrete Design Mix of M25 using 20mm graded aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns etc complete all as specified and directed. |
| 7 | M&L for Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m complete all as specified and directed. |
| 8 | M&L for Reinforced Cement Concrete Design Mix of M25 using 20mm graded aggregate as in columns, pillars, posts and struts etc complete all as specified and directed. |
| 9 | M&L for Reinforced Cement Concrete Design Mix of M25 using 20mm graded aggregate as in Beams , cantilevers , lintels etc complete all as specified and directed. |
| 10 | M&L for Reinforced Cement Concrete Design Mix of M25 using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, etc complete all as specified and directed. |
| 11 | M&L for Brickwork with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed |
| 12 | M&L for Flat Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 13 | M&L for Square, Rectangular or Polygonal Formwork making rough finished surface of concrete to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 14 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)making fair finished surface of concrete complete all as specified and directed. |
| 15 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, lintels, cantilevers making rough finished surface of concrete complete all as specified and directed. |
| 16 | M&L for 15mm thick plastering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and fair without using extra cement complete all as specified and directed. |
| 17 | M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface on walls with water proofing compound @0.2ltrs per 50kg bag of cement complete all as specified and directed.Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’. |
| 18 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 19 | Preparing newly plastered or un plastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed. |
| 20 | M&L for applying three coats of white wash on wall including preparation of new plastered or un-plastered surfaces of walls, complete all as specified and directed. |
| 21 | M & L for rendering 10mm thick in CM 1:3 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for applying three coats of white wash on ceiling including preparation of new plastered or un-plastered surfaces, complete all as specified and directed. |
| 23 | M & L for hardcore of gauge not exceeding 63 mm of broken stone/boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.. |
| 24 | M & L for Moorum/Red Bajri filling under floors layer n exc 150mm spredding and levellling and well rammed complete al as specified and directed. |
| 25 | M&L PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) 75 mm thick as in sub base of floor/path/paving finished even and fair without using extra cement complete all as specified & directed. |
| 26 | M&L 25 mm thick PCC 1:2:4 type B-1 (using 12.50 mm graded stone aggregate) as in sub base of flooring finished even and fair without using extra cement complete all as specified & directed. |
| 27 | M&L non skid coloured tiles (1st quality/ premium quality) 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exc. 0.11 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed.(toilet,bath,kitchen, passage floor) |
| 28 | M&L for coloured glazed ceramic tiles in vertical surface 350 x 250 x 7 mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles including 10mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed . |
| 29 | M&L PCC 1:3:6 C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection (75 mm thick) laying in alternate ways finished even and smooth without using extra cement all as specified. |
| 30 | S&F 15 mm bore chromium bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 31 | S&F 15 mm bore CP Stop valves/Angle Valve, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed. |
| 32 | S&F for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed. |
| 33 | S&F for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed. |
| 34 | S&F 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed. |
| 35 | S&F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed. |
| 36 | S&F 110 mm bore PVC (SWR) cowl of any radius complete all as specified & directed. |
| 37 | Supplying and laying 20 mm outer diameter of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 38 | Supplying and laying 25 mm outer diameter of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 39 | S & F 20 mm outer diameter of CPVC brass elbow fixing to CPVC pipes any location complete all as specified. |
| 40 | S&F 20 mm outer diameter of CPVC brass tee fixing to CPVC pipes any location complete all as specified. |
| 41 | S&F 25 mm outer diameter of CPVC brass elbow fixing to CPVC pipes any location complete all as specified. |
| 42 | S&F 25 mm outer diameter of CPVC brass tee fixing to CPVC pipes any location complete all as specified. |
| 43 | Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth etc brick wall complete all as specified and directed. |
| 44 | S&F vitreous china rimless single piece WC of Size: 380x700x665 mm, Single Piece WC with PP Soft Seat cover, Hinges, Fixing Accessories, Accessories Set, and Cistern fittings, P trap-180mm complete all as specified and directed. |
| 45 | S&F for 500 ltrs capacity rotational moulded polyethylene water storage tank double layered, ISI engraved (cylindrical vertical with closed top) hoisted and fixed in position incl dismantling of water tank complete all as specified & directed. |
| 46 | S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight - 210 gm) complete all as specified and directed. |
| 47 | S&F for PVC connection 15mm size with PTMT nuts, 600 mm long complete all as specified and directed |
| 48 | S&F vitreous china Wash Basin counter Top 600x400x185mm including stainless steel bottle trap and 40 mm dia GI pipe up to Floor trap complete all as specified and directed. |
| 49 | M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. |
| 50 | S&F for powder coated aluminium ventilator shutters with frame not less than 0.55 Kg/Rm, half bottom portion fixed with 4mm thick glass with fixed type shutter and top half portion lower type with 4mm thick glass and outer side fixed with stainless steel wire mesh, shutters aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, necessary aluminium fittings etc complete all as specified and directed. |
| 51 | Supply and fixing looking mirror 5.50mm thick of selected quality mounted on PVC frame and back fixed to wall with screw and rawl plugs complete all as specified and directed. |
| 52 | S & F for tubular towel rail 60 cm length of stainless steel 20 mm Dia with brackets type fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 53 | S&F Health Faucet (ABS Body) with 1.20 M Long PVC Tube and wall Hook screwed down to GI pipe or union/angle valve complete all as specified and directed. |
| 54 | S&F 150 mm square grade of 304 stainless steel grating with openable flap and waste hole (Min weight 100 gms) complete all as spd and directed. |
| 55 | S&F sheet glass shelf assembly consisting of 5.50mm thick sheet glass 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed |
| 56 | Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC , ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed to getter with solvent cement, supplying & fixing in the frame at site as per specification & drawing for Item No. 08080 on page No 174 of SSR 2020 (Part-II) complete all as specified and directed. |
| 57 | S & F Solid PVC door frame for PVC doors, Kitchen cabinet of size 50mm x 47mm made out of 5mm PVC sheet reinforced with MS square tube, as shown on drawings as per manufacturers specification complete all as specified and directed. |
| 58 | S&F 75 mm long mild steel hinges type B-12 complete all as specified and directed. |
| 59 | S&F 100 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 60 | S&F 100 mm long aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 61 | S & F Stainless steel wire cloth, 0.71 mm nominal dia of wire fixed with tinned tacks, of 20mm mesh of stainless steel wire staples complete all as specified and directed |
| 62 | S&F 5.0 mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed. |
| 63 | S & F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed. |
| 64 | S & F 75x125mm dia of PVC (SWR) floor trap, plain with grating incl jointing with solvent cement complete all as specified and directed. |
| 65 | S & F 125/110 mm dia of PVC (SWR) Gully trap, plain with grating incl jointing with solvent cement complete all as specified and directed. |
| 66 | M&L for 150 mm dia SGSW drain pipes grade ‘A’ laid in trenches and jointed in cm 1:1 complete all as specified and directed. |
| 67 | M&L PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for the 150mm dia of pipe complete all as specified and directed |
| 68 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia orsecuring with cli complete all as specified and directed. |
| 69 | M&L Mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with cli complete all as specified and directed. |
| 70 | M&L cement concrete type B-0, 1:2:4 mix ( 12.5 mm graded agg) in padding, roof kerbs or mud stops, rounded or chamfered on edges and similar work including necessary formwork all as specified and directed. |
| 71 | M&L for Apply one coat of Cipoxy 16D primer in the ratio 1:1 spreading at the rate of 0.200 kg-0.250 kg /sqm in complete dry condition where moisture contain below 7% (should be checked with moisture meter)Allow the primer coat to dry for 6 to 8 hours. Apply 1st coat of Roofseal Classic without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. Lay a 45 GSM Fibre glass mesh as a reinforcing material which is incorporated in the coating when the first coat is still in wet condition. Allow the first coat to dry for approximately 4 to 6 hours. Apply the second of chemical with the same application coverage, but in a direction perpendicular to that of the first and second coats. Allow each coat to air cure for a minimum of 4-6 hours after application. Check to see no void surface is left untreated / uncoated.Allow the system to air cure for 7 days minimum etc complete all as specified & directed.Note : The contractor shall submit a gaurantee of 10 years from date of completion of work for waterproofing treatment alongwith manufacturers gauruntee. Contractor have to submit the FDR in the favour of GE (East) Agra before submitting the final bill @ 2.5 % of amount of this item. |
| 72 | Supply only liquid water proofing compound liquid admixture for mortar complete all as specified and directed. |
| 73 | S&F Vitreous China urinals, bowl type ( wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. including of fixing supply pipe to pipe line trap and waste pipe complete all as specified and directed. |
| 74 | S&F 15 mm bore, single lever brass chromium plated wash basin mixer wothout popup waste with 450mm braided hoses opal prime fixed to wash hand basin complete all as specified and directed. |
| 75 | S&F shower arm 600x25x25mm Square shape for wall mounted showers with Flange fixed to Overhead Shower complete all as specified and directed. |
| 76 | S&F Overhead Shower 120x120mm Square shape Single flow(Face plate stainless steel & ABS Body in Chrome Finish) with Rubit Cleaning System for wall mounted showers complete all as specified and directed. |
| 77 | S&F Wall Mixer with connector for Hand Shower arrangement with connecting legs, Wall Flanges & Wall Flanges & Wall Bracket for Hand Shower complete all as specified and directed. |
| 78 | S&F Hand Shower 95mm Round shaped Multi Flow(Rain , Soft & Massage) ABS Body Chrome Plated with Gray Face Plate & Rubit Cleaning System arrangement complete all as specified and directed.. |
| 79 | S&F heavy duty stainless steel pegs/hangers( 6 Pins) of approved make and quality in bathroom areas, manufactured from corrosion-resistant stainless steel (Grade 304), with smooth polished/brush finish, complete with necessary stainless steel screws, wall plugs, and fittings complete all as specified and directed |
| 80 | S & F Soap Dish Holder- Chrome to walls complete all as specified and directed. |
| 81 | Excavating over areas, n exc 1.5 m deep and getting out in soft / loose soil complete all as specified and directed |
| 82 | M&L 15 mm thick rendering on fare faces of brick work or concrete surfaces in cement mortor (1:4) and finishing the surfaces even and smooth with using extra cement complete all as specified and directed |
| 83 | M & L PCC M-10 bed in (1:3:6) using 40 mm graded stone aggregate as in surface channel of drain including providing necessary formwork complete all as specified and directed |
| 84 | M&L Pre-cast RCC 1:2:4 Type B-1 (20mm graded aggregate) as in cover slab for drain and similar work complete all as specified and directed |
| 85 | M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete,using extra cement including forms,moulds, mitred/stopped ends etc. complete all as specified and directed |
| 86 | Removing excavated material exc. 50 m but n exc. 200 m and depositing where directed complete all as specified and directed |
| 87 | M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FRLSH PVC insulated unsheathed cable with proper colour coding drawn in including PVC concealed conduit not less than 20 mm dia medium grade with all accessories and FRLSH PVC insulated 1.5 Sqmm multi standard unsheathed copper wire for continues earth, including cutting and chasing of wall surface for laying PVC conduit and suitable size of modular sunken box and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :- (a) One light /fan point/Exhaust fan point controlled by one switch. |
| 88 | (b) One 3 pin socket outlet 5 amps on the same board with other switches |
| 89 | All as per item No 87 here in before but with cable size 4 Sq mm FRLSH for one 5 pin 15/16 Amps socket/ AC Box out let on independent board and multistrand insulated copper earth continuity conductor of size 4 sqmm all as specified and directed by Engr-in-Charge. |
| 90 | Supply and fixing modular switch piano single pole, one way 6 Amps 1 module, complete all as specified and directed. |
| 91 | Supply and fixing modular socket outlet 2/3 pin 6 Amps combined 2 module, complete all as specified and directed. |
| 92 | S&F ceiling rose , 3 phase/PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals all as specified and directed. |
| 93 | S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 feet 20W) luminaire lumen >2000 lm, system efficiency of >100 lumens /W, with Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed. |
| 94 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 95 | Supply and fixing in replacement LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 25 mm dia GI light grade pipe, 1.00 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 35x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduit including all accessories and fixing arrangements for fixing the light fitting and writing the date of fixing on security light with permt marker complete all as specified and directed. Note:-The period of defects liability shall be 02 Years from the date of installation of security light. |
| 96 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed. |
| 97 | Supply, fix and installation of electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and directed |
| 98 | S&F sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 1x6 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in conduit not less than 20mm, complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring .complete all as specified and directed. |
| 99 | Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with appropriate size bus bar and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 8 way ISI marked, including taking down old unsv MCB DB and MCBs complete all as specified and directed. |
| 100 | Supply and fixing sheet metal enclosure Modular type with socket plug top and MCB single pole and neutral with two pin and earth plug top with one SP MCB 20 Amp 240 volt complete all as directed all as specified and as directed. |
| 101 | Supply and fixing MCB SP 5 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. . |
| 102 | Supply and fixing MCB SPN 40 to 63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 103 | M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. |
| 104 | Supply and fix switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body all as specified and directed. |
| 105 | Supply and fix socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body. |
| 106 | Supplying and fixing 10 watt LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly pre-wired upto terminal block and fixing arrangements for fixing the light fitting, complete all as specified |
| 107 | Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link all as specified and directed. ` Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender