Bids Are invited for Repair And Replacement Of Standby Power Supply To Mrs Alongwith Connected Items
Tender Overview
Project Description
Bids Are invited for Repair And Replacement Of Standby Power Supply To Mrs Alongwith Connected Items Material And Labour In Replacement For Acsr - Material And Labour In Replacement For Acsr Conductor Any Size Drawn Straight Horizontal On Over Head Lines On Existing Poles Including Binding With Insulators Weight Of Conductor Shall Be Measured Straight Horizontal Distance Between Centre Of Two Adjacent Ht Lt Poles And Calculating Weight Of Conductor Of Size Length By Adding 3Percent Extra For Sag Jointing Jumpers Etc Complete All As Specified And Directed. , Supply And Erect Steel Tubular Swaged Poles - Supply And Erect Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Final Taper Plug, Bolts Nuts And Screws As Specified Type 410 Sp 55 11 Mtr Long Erecting In Position All As Specified , Supply And Fixing In Replacement Of Stay Assembly - Supply And Fixing In Replacement Of Stay Assembly Comprising Of 7 Oblique 2.50Mm Galvanized Ms Stay Wire Of Reqd Length, Fixed To Poles With And Including Of Fi Cl S Made Out Of Fi 40X6mm And Nuts Bolts Washers Of Suitable Size Ms Stay Bow 14Mm Dia Galvanized 40Cm Long Ms Galvanised Stay Rod Threaded With Nut 16Mm Dia 21 Cm Long With Washers Ms Stay Plate Galvanized 230X30x6mm Incl Necessary Excavation And Pcc , Material And Labour In Replacement Cross Arms - Material And Labour In Replacement Cross Arms Bracings Supports Cl S And Back Plates Fabricated From Structural Steel Sections Including Nut Bolts Washers Welding Bending Cold And Hot Drilling Holes For Bolts In Any Shape Or Size As Indicate Or Directed And Inclusive Of One Primer Coat One Under Coat And One Finishing Coat Of Paint. , Material And Labour For Restrainging Acsr Conductor - Material And Labour For Restrainging Acsr Conductor 33Kv Ht Line Providing Suitable Proper Sag All As Specified And Directed. , Prunning Of Trees Of Over Head - Prunning Of Trees Of Over Head 33Kv Ht Lines By Taking Proper Shutdown & Removing The Same From Site Upto A Distance Of 50 Mtr All As Directed By Engr In Charge. , Supply And Fixing In Replacement Loop Type - Supply And Fixing In Replacement Loop Type Porcelain White, Brown Or Green Large Size With Cover Dimensions Of 90Mmx140mm Clearance Of Whole 25.5 Mm As Specified , Supply And Fixing In Replacement Of Pin Type - Supply And Fixing In Replacement Of Pin Type Porcelain White Brown Or Green Insulator Including One Galvanized Mild Steel Spindle Two Galvanised Iron Washers And One Galvanised Nut 50Mm Height 65Mm Dia For Working Pressure 33000 Volts Grade.All As Specified And , Excavation In Trenches In Soft - Excavation In Trenches In Soft Oblique Loose Soil Not Exceeding 1.50 M Wide And Not Exceeding 1.50 M In Depth For Foundation Of Poles Stay Cable Pipes Etc And Getting Out Complete All As Specified. , Removal Of Surplus Spoil To A Distance - Removal Of Surplus Spoil To A Distance Not Exc. 50M And Depositing Where Directed At A Level Not Exc. 1.5M Above The Starting Point Complete All As Specified. , Material And Labour For Pcc - Material And Labour For Pcc 1 Ratio 4 Ratio 8 Type D2 Using 40Mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Poles Complete All As Soecified. , Material And Labour - Material And Labour For Pcc 1 Ratio 3 Ratio 6 Type D2 Using 20Mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Stays Complete All As Soecified. , Cable End Termination Jointing Kit - Cable End Termination Jointing Kit For 33 Kv Earthed Grade Cable Outdoor Type Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Sqmm And Entire Satisfaction Of Engnr-In-Charge Complete All As Specifiedand Directed , Material And Labour For Testing - Material And Labour For Testing Of Faulty Ht Cable 33Kv By Using Ht Voltage Fault Locating Machine And Finding The Fault And To Be Repaired The Same Including All T And P As Required On Site Complete All As Directed. , Supply Testing And Laying Xlpe - Supply Testing And Laying Xlpe Insulated, Screened Pvc Bedded Galvanised Steel Strip Or Wire Armoured Heavy Duty Electric Cable With Stranded Aluminium Conductor 33000 Volts Earthed Grade Of Size 300 Sqmm Single Core Complete , Supply And Fixing Of Cable Jointing Kit For 33 Kv - Supply And Fixing Of Cable Jointing Kit For 33 Kv Earthed Grade Cable For Straight Through Joint Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Armoured Al Conductor Cable Of Size 300 Sq Mm And Entire Satisfaction Of Total Quantity : 254
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Material and labour in replacement for ACSR | Material and labour in replacement for ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent HT LT poles and calculating weight of conductor of size length by adding 3percent extra for sag jointing jumpers etc complete all as specified and directed. |
| 2 | Supply and erect steel tubular swaged poles | Supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts and screws as specified type 410 SP 55 11 mtr long erecting in position all as specified |
| 3 | Supply and fixing in replacement of stay assembly | Supply and fixing in replacement of stay assembly comprising of 7 oblique 2.50mm galvanized MS stay wire of reqd length, fixed to poles with and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 21 Cm long with washers MS stay plate galvanized 230x30x6mm incl necessary Excavation and PCC |
| 4 | Material and Labour in replacement cross arms | Material and Labour in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint. |
| 5 | Material and labour for restrainging ACSR conductor | Material and labour for restrainging ACSR conductor 33KV HT line providing suitable proper sag all as specified and directed. |
| 6 | Prunning of trees of over head | Prunning of trees of over head 33KV HT lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by Engr in Charge. |
| 7 | Supply and Fixing in replacement loop type | Supply and Fixing in replacement loop type porcelain white, brown or green large size with cover dimensions of 90mmx140mm clearance of whole 25.5 mm as specified |
| 8 | Supply and Fixing in replacement of pin type | Supply and Fixing in replacement of pin type porcelain white brown or green insulator including one galvanized mild steel spindle two galvanised iron washers and one galvanised nut 50mm height 65mm dia for working pressure 33000 volts grade.all as specified and |
| 9 | Excavation in trenches in soft | Excavation in trenches in soft oblique loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation of poles stay cable pipes etc and getting out complete all as specified. |
| 10 | Removal of surplus spoil to a distance | Removal of surplus spoil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified. |
| 11 | Material and labour for PCC | Material and labour for PCC 1 ratio 4 ratio 8 type D2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified. |
| 12 | Material and labour | Material and labour for PCC 1 ratio 3 ratio 6 type D2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified. |
| 13 | Cable end termination jointing kit | Cable end termination jointing kit for 33 KV Earthed grade cable outdoor type heat shrink type joint complete with jointing material and accessories suitable for single core XLPE Sqmm and entire satisfaction of Engnr-in-Charge complete all as specifiedand directed |
| 14 | Material and Labour for testing | Material and Labour for testing of faulty HT cable 33KV by using HT voltage fault locating machine and finding the fault and to be repaired the same including all T and P as required on site complete all as directed. |
| 15 | Supply testing and laying XLPE | Supply testing and laying XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor 33000 volts Earthed grade of size 300 sqmm single core complete |
| 16 | Supply and Fixing of Cable jointing kit for 33 KV | Supply and Fixing of Cable jointing kit for 33 KV Earthed grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for single core XLPE armoured Al conductor cable of size 300 sq mm and entire satisfaction of |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender