Coal and Mines Boards / Undertakings / PSU Closing in 17 days TDR #56418067

Tender For A) Shifting And Installation Of 1 Mva, 11Kv/3.3Kv Power Transformer, Control Panels, Cable Trench With Bus Bar And Power Re-Organization Of 11Kv/3.3Kv/ Substation Of Karma Project Under Kuju Area. B)Extension Of 11Kv Oh Line For Installati

Issued by Boards / Undertakings / PSU · Ramgarh, Jharkhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Jul 2026
17 days left
EMD
68900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ramgarh → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for A) Shifting And Installation Of 1 Mva, 11Kv/3.3Kv Power Transformer, Control Panels, Cable Trench With Bus Bar And Power Re-Organization Of 11Kv/3.3Kv/ Substation Of Karma Project Under Kuju Area. B)Extension Of 11Kv Oh Line For Installation Of 250Kva Transformer With Control Pannel,Foundation Shade Fencing And Energy Meter With Erection Of 440Oh Line Feeding Power To Outstanding C And Lighting Purpose At Karma Project Under Kuju Area.

BOQ

Name of Work:- A) Shifting and Installation of 1 MVA, 11KV/3.3KV Power Transformer, control panels, Cable trench with bus bar and power re-organization of 11KV/3.3KV/ substation of Karma Project under Kuju Area. B)Extension of 11KV OH line for installation of 250KVA Transformer with control pannel,foundation shade fencing and energy meter with erection of 440OH line feeding power to outstanding c and lighting purpose at karma project under kuju Area.
Sl. No. Item Description
1A . (i)Shifting and Installation of 1 MVA Power Transformer with control Panels bus bar and renovation of distrubution transformer bus bar and secondary control panel.
2Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. For Trench 1 Mtr X 1 Mtr X 60 Mtr= 60 CUMFor Transformer 3 Mtr X3 Mtr X 1 Mtr X 2mtr =18 CUMFor Switch 2 Mtr X3 Mtr X1 Mtr X3=18 CUMFor GOAB/Support/LA 0.75 Mtr X0.75 Mtr X 0.75 Mir X 11 Nos= 4.64 CUM
3Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6(1 cement:6 coarse sand) For Trench Repairing 1 Mtr X 0.12 Mtr X 60 Mtr X 2 side =14.40 CUM Transformer 3 Mtr X 1.50 Mtr X 0.24Mtr X 4 Wall=4.32 CUM2.76 Mtr X 1.50 Mtr X 0.24 Mir X 4 Wall=3.97 CUMSwitch 3 Mr X 1.50 Mtr XO 24 Mtr X 6 Wall-6.48 CUM 1.76 Mtr X 1.50 Mtr X 0.24 Mtr X6 Wall=3.80 CUMFor Trench 1 Mtr X 0.12 Mtr X 60 Mtr =7.20 CUM
4Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1cement: 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
5Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level 11:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 20 mm nominal size)For GOAB 1 Mtr X 0.75 Mtr X 0.75 Mtr X 5 Nos X 2 Side= 5.62 CUMfor Bus support/LA 0.75 Mtr X.0.75 Mtr X 0.75 Mtr X 2 Side X 6 Nos=5.06 CUMFor Transformer 3 Mtr X 3 Mtr X 0.24 Mtr X 2 Nos= 4.32 CUMFor Switch 3 Mtr X2 Mtr X 0.24 Mtr X 3 Nos=4.32 CUMFor Trench 0.75 Mtr X 0.12 Mtr X 60 Mtr X = 5.40 CUM
6Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1.5:3(1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from naturalsources) size) 1 MtrX 0.12 Mtr X 60 Mtr=7.20 CUM
7Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level-Thermo-Mechanically Treated bars of grade Fe-500D or more
8Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 62.5 mm depth X 2.0 mm thickness
9Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the celling with M.S. suspenders Including bolts & nuts, painting suspenders etc as required.300 mm width X 62.5 mm depth X 2.0 mm thickness
10Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 300 mm width X 62.5 mm depth X 2.0 mm thickness.
11Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the celling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 62.5 mm depth X 2.0 mm thickness
12Supplying and filling in plinth with sand under floors, including watering. ramming, consolidating and dressing complete. For Transformer 3 Mtr X2.76 Mer X 1.25 Mtr X2-20.70 CUM For Switch 2.76 Mr X 1.25 Mb X 1.76 Mtr X3 Nos 18.21 CUM For Yard 25 Mtr X 25 Mr X 0.15 Mir-93.75 CUM
13Collection and spreading of metal 40mm graded hard metal in sub-station yard or as required as mentioned below - Metal 40 mm 25 Mtr X 25 Mtr X 0.15 Mtr-93.75 CUM
14Shifting, erection, & commissioning of Transformer 2 Nos, VCB 2 Nos & LT Switch 1 Nos
15Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
16Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 11 KV grade of following size in the existing structure as required. Upto 120 sq. mm
17Supply & Fixing of Support Connector, aluminium alloy material, 48.60 mm size
18Supply & Fixing of Post Insulator, 10KA, 11KV rated, standard size.
19Supply & Fixing of T Connector, aluminium alloy material, 48.60 mm size.
20Supply & Fixing of Nut & Bolts of diiferent size as required
21Supply & Fixing of Enamel Paint
22Supply & Fixing of Red Oxide Paint
23Supply & Fixing of Bi-Metalic connector, aluminium alloy material/brass, 48.60 mm X 12 mm size.
24Supply & Fixing of Pad / Palm Connector, aluminium alloy material, 48.60 mm X 12 mm size.
25Supply & Fixing of Lighting Arrestor line type/ Station Type 9 KV, 12 KA
26Supply & Fixing of Lightning Arrestor Station Type 3.3 KV
27Supply & Fixing of Support Insulator 90mm X 30mm 11KV/3.3KV grade
28Supply & Fixing of Pipe to Pipe Connector, aluminium alloy material, 48.60 mm X 48.60 mm size
29Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:70 sq. mm
30Supply & Fixing of Alloy aluminum pipe 48.3 mm dia inner dia 40.8mm wall thk 3.6mm
31Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
32Supply & Fixing of Alurninium Unarmoured cable single core1100 voltage grade 35 sq mm 48
33Supply & Fixing of Aluminium tub terminal 35 sq mm
34Supply & Fixing of 11 KV grade Air Break Switch 630Amp horizental type
35Supply & Fixing of 11 KV/3.3KV grade Drop Out Fuse 400Amp
36Supply & Fixing of Limit Switch, 800mA, 250VV, 10A
37Supply & Fixing of Cable 2.5sq mm x 2 core copper
38Supply & Fixing of Auxilary Contractor 4 pole, 4NO+4NC
39A(ii)Shade Work
40Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m²
41Providing corrugated G.S. sheet roofing including vertical / curved surfacefixed with polymer coated J or L hooks, bolts and nuts 8 mm diameterwith bitumen and G.I. limpet washers or with G.I. limpet washers filledwith white lead, including a coat of approved steel primer and two coatsof approved paint on overlapping of sheets complete (up to any pitch inhorizontal/ vertical or curved surfaces), excluding the cost of purlins, raftersand trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m²
42Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 0.75 Mtr X0.75 Mtr X 0.75 Mtr X 4 Nos=4.64 CUM
43Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plirith level :1:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 20 mm nominal size)0.75 Mtr X0.75 Mtr X 0.75 Mtr X 4 Nos=4.64 CUM
44Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
45B.Extension of 11KV OH line for installation of 250KVA Transformer with control pannel,foundation shade fencing and energy meter with erection of 440OH line feeding power to outsourcing camp and lighting purpose at Karma project under kuju Area.
46B. (i) Extension of 11KV OH Line.
47Erection of pole of following length in cement concrete 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre
48Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter andabove including binding etc. as required. (02 spans *40m*3 wires)
49Supplying and erection of 11 KV pin insulator complete with largesteel head G.I. pin, nuts, washers etc. as required
50Supplying and erection of 11 KV disc insulator for 11 KV overhead lines with galvanised insulator fittings, ball and socket typeand complete with galvanised strain clamps, bolts, nuts, washers etc. as required
51Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg permetre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required
52Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg permetre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulatorpins etc (as per drawing) and painting with primer and finishedpaint as required
53Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg permetre) cross arm for two 11 KV over head line conductorscomplete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flatiron clamps, bolts and nuts including drilling holes for insulatorpins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
54Supplying and erection of bow stay set complete (galvanised)with 19/20 mm dia X 1.8 metres long stay rod, anchor plate ofsize 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle(20 mm X 60 cm), 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundationincluding excavation and refilling and also with 0.6 m long braceof size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulleyfixed at one end of the brace as required.
55Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) double pole cross arm for three wire 11KVover head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded onone side to the channel iron and with bolts and nuts on the otherside for tying the cross arms together, including drilling holes forinsulator pins/fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
56Supply & Fixing of Lighting Arrestor Station Type 11 KV
57Support Insulator 90mm X 30mm 11KV/3.3KV grade
58Supply & Fixing of 11 KV grade Air Break Switch 630Amp horizental type
59Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
60Supply & Fixing of Aluminium Unarmoured cable single core1100 voltage grade 35 sq mm
61Supply & Fixing of Aluminium tub terminal 35 sq mm
62Supply & Fixing of 11 KV/3.3KV grade Drop Out Fuse 400Amp
63Supplying and erection of a set of cross bracing FRLSame workfor 11 KV over head line double pole structure having four membersfabricated of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts andnuts including drilling holes for insulator pins, bolts and nuts etc(as per drawing) and painting with primer and finish paint as required
64Erection, & commissioning of Transformer 1 No. 250 KVA & VCB 1 No. 11KV Grade
65Supply & Fixing of Pad / Palm Connector, aluminium alloy material, 48.60 mm X 12 mm size.
66Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:70 sq. mm
67B(ii) Making of foundation for Transformer & VCB Installation
68Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 3 Mtr X 3 Mtr X 1X2nos. 18 CUM (For foundation of Transformer and VCB) 0.75Mtr X 0.75 Mtr X 1MtrX10nos. =5.625 CUM 25 Mtr X 15 Mtr X 0.25 Mtr=93.75 CUM (For filing and dressing of site)
69Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6(1 cement:6 coarse sand) 2.76 Mtr X 1.5 Mtr X 0.24 Mtr X 8 Wall=3.97 CUM (For foundation of Transformer and VCB)
70Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1cement: 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick (2.76m*1m*8nos.+2.76m*2.76m*2nos.)
71Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 20 mm nominal size) 2.76 Mtr X2.76 Mtr X 0.24 Mtr X 2-3.66 CUM (For foundation top) X 0.6 Mtr X 0.8 Mtr X 10nos. 2.88 CUM (For foundation of steel frame for Shed) 0.6 Mtr
72Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 2.76 Mu X 2.76 Mr X 0.75 Mtr X 2 nos.=11.43CUM
73B(iii)Shed & chain link mesh works
74Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m²
75Providing corrugated G.S. sheet roofing including vertical / curved surfacefixed with polymer coated J or L hooks, bolts and nuts 8 mm diameterwith bitumen and G.I. limpet washers or with G.I. limpet washers filledwith white lead, including a coat of approved steel primer and two coatsof approved paint on overlapping of sheets complete (up to any pitch inhorizontal/ vertical or curved surfaces), excluding the cost of purlins, raftersand trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m² (6mX8M roof+4mX6m side+4mX8MX2 side)
76Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (Frame for Shed)
77Supply & fixing fencing of chain link mesh 100 x 100 mm, 12 SWG GI wire for for D.P. structure electric substation switch yard including single post of angle iron size 50x50x5mm, 2.5 ml long should be provided upto 2.00 mt. apart or as required. The panel frame with required angle iron/ flat iron members/cross members including mesh welded in frame panel shall be erected between the posts. The angle iron post shall be erected in cement concrete M-15 (1:2:4) (20 mm graded metal) foundation, including excavation of pit and refilling the same. The fencing shall be provided with one entrance gate including locking arrangement as required as per specification. The height of fencing shall be 2 mt. above groun level. Fencing shall be painted with required shade (25+15)*2m*2m=160
78B(iv) Extention of 440Volt OH line
79Supply & Fixing of 4 pole MCCB DN4-1250N (Release Range 320-800) with earth leakage relay protection
80Erection of pole of following length in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre
81Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) double pole cross arm for three wire 11KVover head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded onone side to the channel iron and with bolts and nuts on the otherside for tying the cross arms together, including drilling holes forinsulator pins/ fittings, bolts, nuts and washers etc (as per drawing)and painting with primer and finish paint as required.
82Supplying and erection of bow stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate ofsize 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle(20 mm X 60 cm), 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundationincluding excavation and refilling and also with 0.6 m long braceof size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulleyfixed at one end of the brace as required.
83Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required
84Supply & Fixing of Aluminium Unarmoured cable single core 1100 voltage grade 35 sq mm
85Supply & Fixing of Aluminium Tubular Lug 35 sq mm
86Supplying and erection of a set of cross bracing FRLSame workfor 11 KV over head line double pole structure having four membersfabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts andnuts including drilling holes for Insulator pins, bolts and nuts etc(as per drawing) and painting with primer and finish paint as required.
87Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required 2 x 2.5 sq. mm
88Providing and fixing 50 mm dia X 3.2 metres G.I. pipe (including accessories) complete with 50 mm X 50 mm X 6 mm angle iron bracket on wall and 75 mm X 90 mm shackle insulator with straps for house service connection including painting the angle and flat iron with primer and finish paint etc. as required
89Supplying & drawing/laying of PVC insulated XLPE aerial bunch power cable conductor H2/H4 grade aluminium solid/stranded conforming to IS-14255-1995, alu, alloy insulated messenger 1100 volts grade cable of approved make in air with necessary material as per specification of required size as mentioned below-3x70 sq.mm, 1x16(st. light), 1x35 (insulated neutral messenger) (7spans*35m)
90Supplying & fixing of aerial bunch cable accessories suspension clamp i/c required attachment for single core cable of approved make on pole with clamp, necessary material as per specification for required size
91Supplying &fixing of aerial bunch cable accessories tension clamp (dead end) i/c required attachment for single core cable of approved make in air with clamp, necessary material as per specification for required size
92Supplying & fixing of waterproof insulation piercing connector for aerial bunch cable i/c required attachment for single core cable of approved make in air with necessary material as per specification of required size as mentioned below-Main:50-150sq.mm
93Supply & Fixing of Smc A B Cable Distribution Box Size
94B(v) Installation of Energy Meter
95Supply & Fixing of 11kv Ht Bi-directional Net Class-0.2s 3-phase Energy Meter
96Supply & Fixing of CT ring type 400 S1
97Wiring with ferruls & Lugs
98Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56418067
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 29-07-2026
Authority
Authority Name Central Coalfields Limited
Work Description Tender for A) Shifting And Installation Of 1 Mva, 11Kv/3.3Kv Power Transformer, Control Panels, Cable Trench With Bus Bar And Power Re-Organization Of 11Kv/3.3Kv/ Substation Of Karma Project Under Kuju Area. B)Extension Of 11Kv Oh Line For Installation Of 250Kva Transformer With Control Pannel,Foundation Shade Fencing And Energy Meter With Erection Of 440Oh Line Feeding Power To Outstanding C And Lighting Purpose At Karma Project Under Kuju Area.
Basic Detail
Tender No GM (K)/EnM/eTender/26-27/56
Bidding Type Tender
Location
City Ramgarh
State Jharkhand
Key Dates
Publish Date 10 Jul 2026
Submission Date 29 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 68900
Exemption Not Available
Document List
BOQ_374804.xls
e2611df2-005e-40f0-aa38-2f68cbd55e12.html
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_374804.xls

html

e2611df2-005e-40f0-aa38-2f68cbd55e12.html

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders