Coal and Mines Boards / Undertakings / PSU Closing in 10 days TDR #56418065

Tender For Erection And Charging A New Standby 11 Kv Feeder With Accessories From 33/11 Kv Jealgora Substation To Marigodam Basti Substation Parallel To Existing Jeenagora Feder Of Amal.Nt-St-Kujama Colliery Under Lodna Area.

Issued by Boards / Undertakings / PSU · Dhanbad, Jharkhand
Tender Value
69.07 Lakhs
Estimated cost
Bid Submission
24 Jul 2026
10 days left
EMD
86343
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dhanbad → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Erection And Charging A New Standby 11 Kv Feeder With Accessories From 33/11 Kv Jealgora Substation To Marigodam Basti Substation Parallel To Existing Jeenagora Feder Of Amal.Nt-St-Kujama Colliery Under Lodna Area.

BOQ

Name of Work:- Erection and Charging a new standby 11 KV feeder with accessories from 33/11 KV Jealgora substation to Marigodam Basti substation parallel to existing Jeenagora feder of Amal.NT-ST-Kujama Colliery Under Lodna Area.
Sl. No. Item Description
1Erection of Rail pole of 60/52 Kg 13 Meter length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
2Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
3Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
4Supply of G.I wire 8 SWG
5Erection of G.I wire 8 SWG
6Supply of AB switch Nominal Voltage 11 KV grade, Rated Voltage 12 KV, 1240 A, 3- Phase Outdoor Type offload disconnection in horizontal plane with earthing switch
7Erection of AB switch Nominal Voltage 11 KV grade, Rated Voltage 12 KV, 1240 A, 3- Phase Outdoor Type offload disconnection in horizontal plane with earthing switch
8Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
9Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required
10Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required
11Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required
12Erection of DOG conductor including binding as required 2 KM+10% Sag= 2.2 KM = 2600.4 KG.
13Erection of Wolf conductor including binding as required 1.2 KM+10% Sag= 1.32 KM = 958.32 KG.
14Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
15Laying of 185/240 sqmm size 11KV grade PVC Cable
16supply installation testing & commissioning of 1250A 11KV VCB 3 phase indoor type ISI marked with suitable other fitting & accessories (relays & energy meter) including all labour tools & technician cost
17Supply installation testing & commissioning of 1250A 33KV VCB 3 phase outdoor type with control panel unit ISI marked with suitable other fitting & accessories(relays & energy meter) controlled by 110V DC/220V AC including all labour tools & technician cost
18Supply installation testing & commissioning of control panel unit for VCB comprising such as under load current & overload current protection undervoltage & overvoltage protection,instant earth fault, phase frequency protection WTI & OTI protection,buchholz protection etc. all complete
19supply,installation & commissioning of differential numerical transformer protection relay for incomer relay with all electric connection & making accurate setting for load & tripping etc. all complete with labour tools
20supply & laying of 16C x 2.5sqmm copper control cable 1100V grade ISI marked for control wiring
21supply & fitting of GI flat size 50mm X 6mm for making earthing connection from earthing pit to CT, PT, VCB ,AB switches etc.
22Supply & fitting of outdoor HT connector suitable for aluminium tubular pipe bus (IPS HT tube), suitable for 33KV Sub-station
23Erection of 11KV power line for underground railway crosssingby 2 nos (including 1 spare) 3 core X 185/240 sqmm XLPE armoured cable using 250mm dia MS pipes cable markers making of push pit both sides sealing of MS pipes as per TS drawings and scope of work.
24Making of indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for upto size of 185/240sqmm of 3 core XLPE AL cable of 11KV grade as required
25Making of outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for upto size of 300/240sqmm of 3 core XLPE AL cable of 11KV grade as required
26Supply & laying of 50mm dia aluminium tubular bus pipe (IPS HT tube),suitable for 33KV sub-station
27cost towards supplying installation and commissioning of 33KV oil cooled outdoor trype C.T. of CT Ratio-600A-400A-1A-1A of approved make ISI marked including all labour tools, tackles and technician costs etc all complete
28Supply & Fitting of Craddle Guard
29Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56418065
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 69.07 Lakhs
LAST DATE 24-07-2026
Authority
Authority Name Bharat Coking Coal Limited
Work Description Tender for Erection And Charging A New Standby 11 Kv Feeder With Accessories From 33/11 Kv Jealgora Substation To Marigodam Basti Substation Parallel To Existing Jeenagora Feder Of Amal.Nt-St-Kujama Colliery Under Lodna Area.
Basic Detail
Tender No BCCL/LA/ENM/F-19/26-27/011
Bidding Type Tender
Location
City Dhanbad
State Jharkhand
Key Dates
Publish Date 10 Jul 2026
Submission Date 24 Jul 2026
Open Date 25 Jul 2026
Finance
Tender Value 69.07 Lakhs
Tender Fee Ref. Documents
EMD 86343
Exemption Not Available
Document List
4ca3f6dd-8613-42a5-ae12-098e778eeffc.html
BOQ_374780.xls
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

4ca3f6dd-8613-42a5-ae12-098e778eeffc.html

xls

BOQ_374780.xls

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender