Tender For Supply Of Science Lab Item- 1 Pcr :-Thermocycler Along With Essential Supporting Equipments Such As :-• Thermocycler: Standard 96-Well Format.• Micropipettes: 2−20Μl And 20−200Μl.• Pcr Reagents: Dna Polymerase, Dntps, Buffers.• Supporting Hardware:O Vortex Mixero Microcentrifugedigital Dry Bath 2 Electrophoresis :-• Main Chamber: Plastic Or Acrylic.• Units: Can Be Horizontal (Preferred) Or Vertical Units.• Power Supply: Required To Provide The Electrical Current.• Accessories: Gel Casting Accessories.• Optional: Gel Documentation System. 3 Rotary Microtome :- Used For Cutting Thin Sections Of Tissue For Microscopy.• Operation: Manual.• Section Thickness: Adjustable Range From 1 To 50 Micrometers.• Build Material: Heavy And Rigid Iron Or Stainless Steel (Ss).• Accessories: Steel Razor/Knife (120Mm Or 180Mm) With Back And Handle. 4 Tlc (Thin Layer Chromatography) Equipment :-Used For Analyzing The Composition Of Mixtures.• Tlc Plates: Coated With Adsorbents Such As Silica Gel, Alumina, Or Cellulose.• Developing Chamber/Tank: For Plate Incubation.• Application Tools:O Spotting Equipmento Spreader/Applicator• Storage & Preparation: Plate Rack, Solvents, And Desiccants. 5 Hot Plate :-Used For Controlled Heating Of Samples.• Top Plate Material: Cast Iron Or Stainless Steel (Ss).• Control: Digital Interface.• Shape: Rectangular Or Circular (Should Be Large Enough To Hold Beakers And Flasks).• Feature: Often Includes Magnetic Stirrers. 6 Digital Ph Meter :-Range: - 0-14Ph, Mv = 1999 Resolution 0.001 Ph Accuracy = 0.01 Calibration Auto 3- Point Atc Probe Included Approx. Cost 8000-20000 7 Lcd Digital Microscope:-Celestron 44341 Lcd Digital Microscope 8 Trinocular Microscope / Digital Microscope :-E.S.A.W Trinocular Microscope Cmos Camera 5Mp(White) With Slide Box With Semi-Plan Objectives (Magnifications 40X-1500X) Oresaw Optscopes Classic 40X-2000X Digital Microscope With 5.1Mp Is-500 Cmos Microscopic Camera (For Education, Pathology, Research And Teaching) 9 Digital Camerax :-Canon Eos 1500D 24.1 Digital Slr Camera (Black) With Ef S18-55 Is Ii Lens, 16 Gb Card Ornikon D3500 Dslr Camera With Af-P 18-55Mm Vr Lens. 10 Spectrophotometer Digital 11 Polarimeter (Digital / Automatic Polarimeter) :-• Light Source: Led With Sodium (Na) Lamp, 589 Nm• Measuring Range: –45° To +45° (Optical Rotation)• Accuracy: ±0.01°• Resolution: 0.001°• Optical Path Length: 100 Mm Standard Tube• Temperature Control: Built-In Or External (20–30°C)• Display: Digital Lcd / Touch Screen• Calibration: Automatic With Quartz Control Plates• Communication: Usb Interface (Optional)• Power Supply: 220–240 V Ac, 50 Hz 12 Uv–Visible Spectrophotometer :-• Optical System: Double Beam• Wavelength Range: 190–1100 Nm• Spectral Bandwidth: 1–2 Nm• Wavelength Accuracy: ±0.3 Nm• Wavelength Repeatability: ±0.2 Nm• Photometric Range: –0.3 To 3.5 Abs• Photometric Accuracy: ±0.002 Abs• Light Source: Deuterium (Uv) + Tungsten (Visible)• Software: Pc-Based With Kinetics, Quant, Spectrum, Dna/ Protein Analysis• Cuvettes: Quartz Cuvettes (1 Cm Path Length)• Power Supply: 220–240 V Ac 13 Digital Ph Meter :-• Ph Range: 0–14 Ph• Accuracy: ±0.01 Ph• Resolution: 0.001 Ph• Temperature Compensation: Automatic (Atc) With Probe• Electrode: Combined Glass Electrode• Calibration: 2-Point Or 3-Point Automatic• Display: Large Lcd• Additional Parameters (Optional): Conductivity, Tds• Power: 220 V Ac / Battery Backup 14 Polarography Instrument (Electrochemical Analyzer) :-• Technique Support: Dc Polarography, Pulse Polarography, Differential Pulse Voltammetry• Working Electrode: Hanging Mercury Drop Electrode (Hmde) Or Dropping Mercury Electrode (Dme)• Reference Electrode: Ag/Agcl• Auxiliary Electrode: Platinum Wire• Potential Range: –2 V To +2 V• Potential Accuracy: ±1 Mv• Current Range: Nanoampere To Milliampere• Software: Computer Interface For Voltammogram Recording• Stirrer: Magnetic Stirrer Built-In• Power: 220–240 V 15 Water & Soil Testing Instrument Set - Basic Laboratory Kit Includes For Water Testing: Ph Meter (0–14, Accuracy 0.01) Tds Meter: 0–10,000 Ppm Conductivity Meter: 0–200 Ms/Cm Turbidity Meter: 0–1000 Ntu Cod Digestion Unit: 6/15-Sample Block Bod Incubator: 20°C ±1°C Flame Photometer: For Na, K, Ca, Li For Soil Testing: Soil Ph & Ec Meter Soil Moisture Analyzer Kjeldahl Nitrogen Digestion & Distillation Unit Spectrophotometer (Uv-Vis) Hot Air Oven: Up To 250°C Muffle Furnace: Up To 1000°C Balance: Analytical Balance (0.1 Mg Accuracy 16 E/M By Helical Method -As Per Available 17 Four Probe Experiment -As Per Available 18 Amplitude Modulation-As Per Available 19 Frequency Modulation-As Per Available 20 Multi Vibrater-As Per Available 21 Lattice Dynamics Exp.-As Per Available 22 B-H Curve Exp-As Per Available 23 Complete Set Up For Study Of Zeeman Effect -As Per Available 24 Study Of Voltage Regulation Using Ic-317 (Single Board)- As Per Available 25 Cro (Cathode Ray Oscilloscope) -Bandwidth 50Mzh-200 Mzh, Analog Channels 02, Sample Rate 1Gh/S 26 Sodium Lamp -As Per Available 27 Mercury Lamp -As Per Available 28 Heat Capacity Of Solid Exp.-As Per Available 29 Microwave Test Bench (Complete) For :- (A) Reflex Klystron Study (B) Measurement Of Guide Wavelength & Frequency (C) Vswr Using Slotted Line (D) Impedance Measurement (E) Study Mode Characteristics Of Reflex Klystron 30 Microwave Test Bench (Complete Set) For (A) Study Of Gunn Oscillator (B) Freq & Guide Wavelength Measurement (C) Measurement: Vswr/Reflection Coefficient (D) Impedance Measurement
BOQ
| Sl. No. | Item Description |
| 1 | PCR :-Thermocycler along with essential supporting equipments such as :-• Thermocycler: Standard 96-well format.• Micropipettes: 2−20μL and 20−200μL.• PCR Reagents: DNA polymerase, dNTPs, buffers.• Supporting Hardware:o Vortex mixero MicrocentrifugeDigital dry bath |
| 2 | Electrophoresis :-• Main Chamber: plastic or acrylic.• Units: Can be Horizontal (preferred) or Vertical units.• Power Supply: Required to provide the electrical current.• Accessories: Gel casting accessories.• Optional: Gel documentation system. |
| 3 | Rotary Microtome :- Used for cutting thin sections of tissue for microscopy.• Operation: Manual.• Section Thickness: Adjustable range from 1 to 50 micrometers.• Build Material: Heavy and rigid iron or stainless steel (SS).• Accessories: Steel razor/knife (120mm or 180mm) with back and handle. |
| 4 | TLC (Thin Layer Chromatography) Equipment :-Used for analyzing the composition of mixtures.• TLC Plates: Coated with adsorbents such as silica gel, alumina, or cellulose.• Developing Chamber/Tank: For plate incubation.• Application Tools:o Spotting equipmento Spreader/Applicator• Storage & Preparation: Plate rack, solvents, and desiccants. |
| 5 | Hot Plate :-Used for controlled heating of samples.• Top Plate Material: Cast iron or stainless steel (SS).• Control: Digital interface.• Shape: Rectangular or circular (should be large enough to hold beakers and flasks).• Feature: Often includes magnetic stirrers. |
| 6 | Digital PH Meter :-Range: - 0-14pH, mv = 1999 Resolution 0.001 pH Accuracy = 0.01 Calibration Auto 3- point ATC Probe Included Approx. Cost 8000-20000 |
| 7 | LCD Digital Microscope:-Celestron 44341 LCD Digital Microscope |
| 8 | Trinocular Microscope / Digital Microscope :-E.S.A.W Trinocular Microscope CMOS Camera 5MP(White) with slide box with Semi-Plan Objectives (Magnifications 40x-1500x) ORESAW Optscopes Classic 40x-2000x Digital Microscope with 5.1MP IS-500 CMOS Microscopic Camera (for Education, Pathology, Research and Teaching) |
| 9 | Digital Camerax :-Canon EOS 1500D 24.1 Digital SLR Camera (Black) with EF S18-55 is II Lens, 16 GB Card ORNikon D3500 DSLR Camera with AF-P 18-55mm VR Lens. |
| 10 | Spectrophotometer Digital |
| 11 | Polarimeter (Digital / Automatic Polarimeter) :-• Light Source: LED with Sodium (Na) lamp, 589 nm• Measuring Range: –45° to +45° (optical rotation)• Accuracy: ±0.01°• Resolution: 0.001°• Optical Path Length: 100 mm standard tube• Temperature Control: Built-in or external (20–30°C)• Display: Digital LCD / touch screen• Calibration: Automatic with quartz control plates• Communication: USB interface (optional)• Power Supply: 220–240 V AC, 50 Hz |
| 12 | UV–Visible Spectrophotometer :-• Optical System: Double beam• Wavelength Range: 190–1100 nm• Spectral Bandwidth: 1–2 nm• Wavelength Accuracy: ±0.3 nm• Wavelength Repeatability: ±0.2 nm• Photometric Range: –0.3 to 3.5 Abs• Photometric Accuracy: ±0.002 Abs• Light Source: Deuterium (UV) + Tungsten (Visible)• Software: PC-based with kinetics, quant, spectrum, DNA/ protein analysis• Cuvettes: Quartz cuvettes (1 cm path length)• Power Supply: 220–240 V AC |
| 13 | Digital pH Meter :-• pH Range: 0–14 pH• Accuracy: ±0.01 pH• Resolution: 0.001 pH• Temperature Compensation: Automatic (ATC) with probe• Electrode: Combined glass electrode• Calibration: 2-point or 3-point automatic• Display: Large LCD• Additional Parameters (Optional): Conductivity, TDS• Power: 220 V AC / battery backup |
| 14 | Polarography Instrument (Electrochemical Analyzer) :-• Technique Support: DC Polarography, Pulse Polarography, Differential Pulse Voltammetry• Working Electrode: Hanging Mercury Drop Electrode (HMDE) or Dropping Mercury Electrode (DME)• Reference Electrode: Ag/AgCl• Auxiliary Electrode: Platinum wire• Potential Range: –2 V to +2 V• Potential Accuracy: ±1 mV• Current Range: Nanoampere to milliampere• Software: Computer interface for voltammogram recording• Stirrer: Magnetic stirrer built-in• Power: 220–240 V |
| 15 | Water & Soil Testing Instrument Set - Basic laboratory kit includes For Water Testing: pH meter (0–14, accuracy 0.01) TDS Meter: 0–10,000 ppm Conductivity Meter: 0–200 mS/cm Turbidity Meter: 0–1000 NTU COD Digestion Unit: 6/15-sample block BOD Incubator: 20°C ±1°C Flame Photometer: For Na, K, Ca, Li For Soil Testing: Soil pH & EC Meter Soil Moisture Analyzer Kjeldahl Nitrogen Digestion & Distillation Unit Spectrophotometer (UV-Vis) Hot Air Oven: Up to 250°C Muffle Furnace: Up to 1000°C Balance: Analytical balance (0.1 mg accuracy |
| 16 | e/m by Helical Method -As per Available |
| 17 | Four Probe experiment -As per Available |
| 18 | Amplitude Modulation-As per Available |
| 19 | Frequency Modulation-As per Available |
| 20 | Multi Vibrater-As per Available |
| 21 | Lattice Dynamics exp.-As per Available |
| 22 | B-H Curve exp-As per Available |
| 23 | Complete set up for study of Zeeman effect -As per Available |
| 24 | Study of Voltage Regulation using IC-317 (Single Board)- As per Available |
| 25 | CRO (Cathode Ray Oscilloscope) -Bandwidth 50Mzh-200 Mzh, Analog Channels 02, Sample rate 1gh/s |
| 26 | Sodium Lamp -As per Available |
| 27 | Mercury Lamp -As per Available |
| 28 | Heat Capacity of Solid exp.-As per Available |
| 29 | Microwave Test Bench (Complete) for :- (a) Reflex Klystron study (b) Measurement of guide wavelength & frequency (c) VSWR using slotted line (d) Impedance Measurement (e) Study mode characteristics of Reflex Klystron |
| 30 | Microwave Test Bench (Complete set) for (a) Study of Gunn Oscillator (b) Freq & guide wavelength measurement (c) Measurement: VSWR/Reflection Coefficient (d) Impedance Measurement |
| 31 | Measurement of Radiation pattern & gain (+8500/- an antenna)- As per Available |
| 32 | Measurement of Dielectric constant by M.W. Bench - As per Available Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender