Tender For Repairing And Renovation Of Old Antenatal Ward, Post Natal Ward, Old Gynae Ot To Turn Into Emergency Department At Bidhan Block Ground Floor Of Midnapore Medical College And Hospital, Paschim Medinipur.--- S & I Of Air-Conditioning System.
Tender Overview
Project Description
Tender for Repairing And Renovation Of Old Antenatal Ward, Post Natal Ward, Old Gynae Ot To Turn Into Emergency Department At Bidhan Block Ground Floor Of Midnapore Medical College And Hospital, Paschim Medinipur.--- S & I Of Air-Conditioning System.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-Jul-2026 | BOQ ADDENDUM | Other | 28-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply & Delivery of Ductable split airconditioners having Microprocessor based control system and the following specification.Capacity-11.0 Tonnage (with applicable tolarance)No. of IDU-1 NoIDU Type - Ducted typeAir-flow/IDU-4400CFMPower Supply of IDU :220v, 50Hz,1Ph AC (with applicable tolarance)No of ODU- 2NosCompressor -2 Nos. CompressorCompressor Type- Scroll type Refrigerent -R410ACondenser & Cooling Coil:Copper coilPower Supply of ODU :415v, 50Hz,3 Ph AC (with applicable tolarance)[ Make-Hitachi/Voltas/Carrier] |
| 2 | 11.0 TR Nominal Capacity |
| 3 | Supply & Delivery of Ductable split airconditioners having Microprocessor based control system and the following specification.Capacity-3.0 Tonnage (with applicable tolarance)No. of IDU-1 NoIDU Type - Ducted typeAir-flow/IDU-2200CFMPower Supply of IDU :220v, 50Hz,1Ph AC (with applicable tolarance)No of ODU- 1NosCompressor -1 Nos. CompressorCompressor Type- Twin Rtary/Scroll type Refrigerent -R410ACondenser & Cooling Coil:Copper coilPower Supply of ODU :415v, 50Hz,3 Ph AC (with applicable tolarance)[ Make-Hitachi/Voltas/Carrier/OG] |
| 4 | 3.0 TR Nominal Capacity |
| 5 | Installation Testing and Commissioning of Ductable Split AirConditioners by making scaffolding arrangement as per site condition, Supply of necessary Refrigerant, connecting Control & power cabling & other necessary materials to complete the job. |
| 6 | 11.0 TR Nominal Capacity |
| 7 | 3.0 TR Nominal Capacity |
| 8 | REFRIGERANT PIPING & ACCESSORIES- Supply, design, fabrication and laying of Hard drawn Refrigerant Copper pipes complete with thermal insulation by closed cell Nitrile Rubber Insulation class O grade, Nitrogen pressure testing, leak testing, vacuumizing, required refrigerant charging and commissioning work. COPPER PIPE MAKE: RAJCO/Uniflow/NIPPON, NITRILE RUBBER INSULATION: K-FLEX/ SUPRIME/A-FLEX |
| 9 | 22.2mm Dia 1 mm thick Copper hard drawn suction tube with 9 mm thick Class O plain Nitrile Rubber Insulation as per OEM design recommendations |
| 10 | 12.7 mm Dia 0.7 mm thick Copper hard drawn Liquid Line as per OEM design recommendations |
| 11 | 19.04mm Dia 1 mm thick Copper hard drawn suction tube with 9 mm thick Class O plain Nitrile Rubber Insulation as per OEM design recommendations |
| 12 | 9.52 mm Dia 0.7 mm thick Copper hard drawn Liquid Line as per OEM design recommendations |
| 13 | In and Out Liquid Line Ball Valve(Make- Danfoss/Emerson) |
| 14 | 32 mm NB Rigid PVC pipe with 6 mm thick Nitrile Rubber Insulation for AHU Drain pipe up to nearest drain point(Make-Supereme/Oriplast/Finolex) |
| 15 | 25 mm NB Rigid PVC pipe with 6 mm thick Nitrile Rubber Insulation for AHU Drain pipe up to nearest drain point(Make-Supereme/Oriplast/Finolex) |
| 16 | GSS DUCT-Supply, design, fabrication and installation of GI sheet metal duct as per approved drawing along with necessary supports, hangers, flanges etc. as required and as per IS 655 and IS- 277 standards of following gauges by using proper scaffolding and safety arrangements.(Make: SAIL/TATA/JSW) |
| 17 | 24 SWG thick |
| 18 | 22 SWG thick |
| 19 | Supply & fixing of milky while powder coated Aluminium extruded supply air Defuser with volume control damper. Make: Systemair/Air Enterprise/ Dynacraft/Air Master |
| 20 | Supply & fixing of milky while powder coated Aluminium extruded return air Defuser without volume control damperMake: Systemair/Air Enterprise/ Dynacraft/Air Master |
| 21 | Supply & Fixing of milky while powder coated Aluminium extruded Continuous Grill/Discrite type grill. Make: Systemair/Air Enterprise/ Dynacraft/Air Master |
| 22 | CANVAS CONNECTIONS-Supply & fixing of fire- retardant Canvas Connections for IDUs |
| 23 | DUCT MOUNTED FUSIBLE LINK FIRE DAMPER-Supply and fixing of mechanical spring return type MS Fire Damper with fusible link |
| 24 | DUCT MOUNTED NON RETURN DAMPER-Supply and fixing of mechanical return type MS Non Return Damper |
| 25 | VOLUME CONTRAL DAMPER-Supply and fixing of mechanical return type MS Volume Contral Damper |
| 26 | DUCT THERMAL INSULATION- Supplying and fixing of 13 mm thick duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self-adhesive nitrile rubber tape insulation complete by using proper scaffolding and safety arrangements. (As per direction of E.I.C). Make: KFlex/Armacell/Aflex/Suprime |
| 27 | DUCT ACCOUSTIC INSULATION- Supplying and fixing of 10 mm open cell Nitrile rubber (Class “1”) insulation for total duct after applying suitable adhesive, nut bolts etc by using proper scaffolding and safety arrangements. (As per direction ofE.I.C)Make: KFlex/Armacell/Aflex/Suprime |
| 28 | POWER & CONTROL CABLE-Supply & laying of PVC- Sheathed cable for Control cables. Make: RR/Kable/Polycab/Finolex/Nicco3 Core 2.5 sqmm XLPE Cu Cable |
| 29 | COMUNICATION CABLE-Supply & laying of PVC- Sheathed cable for Control cables. Make: RR/ Kable/Polycab/Finolex/Nicco3 Core 1.5 sqmm XLPE Cu Cable |
| 30 | MS STRUCTURAL WORK-Supply, design, fabrication, installation of MS structural work : M.S. works fabricated from U-Channel, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. The above structure should be painted 2 coats painting over 2 coats of primer as per direction of EIC. |
| 31 | Loading, unloading, lifting, shifting and placement of all equipment, accessories and ancillaries including transportation |
| 32 | Minor Civil wall cut out for laying Duct, pipe, cable, fresh air and exhaust as and where required by using proper scaffolding and safety arrangements. (As per direction of E.I.C) |
| 33 | Charges for Scaffolding Arrangements for installation of different size AC Machine Indoor& Outdoor Unit at site |
| 34 | Supplying, fitting & fixing in position suspended boxing for Ductable AC Machine with frame work of aluminium hollow section of size 50mm x25mm (1.1mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm, 25mm x 25mm powder coated wall angle with aluminium composit panel(ACP- Make-Aludecor/Protap Bond) of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of EIC. |
| 35 | Charges of trapdoor made by ACP Board |
| 36 | Supply & Delivery of Flexi type split airconditioners having Microprocessor based control system and the following specification.Capacity-7.5 Tonnage No. of IDU-3 NoIDU Type - ConcealedAir-flow/IDU-1000CFMNo of ODU- 1 NosCompressor -3 Nos. CompressorCompressor Type- Twin Rotary type Refrigerent -R410ACondenser & Cooling Coil:Copper coilPower Supply :415v, 50Hz,3 Ph AC (with applicable tolarance)[MAKE_VOLTAS/BLUE STAR/CARRIER/HITACHI] |
| 37 | Supply & Delivery of Flexi type split airconditioners having Microprocessor based control system and the following specification.Capacity-5.0 Tonnage No. of IDU-2 NoIDU Type - ConcealedAir-flow/IDU-1000CFMNo of ODU- 1 NosCompressor -2 Nos. CompressorCompressor Type- Twin Rotary type Refrigerent -R410ACondenser & Cooling Coil:Copper coilPower Supply :415v, 50Hz,3 Ph AC (with applicable tolarance)MAKE_VOLTAS/BLUE STAR/O GENERAL/CARRIER/HITACHI |
| 38 | Installation Testing and Commissioning of Ductable Split AirConditioners by making scaffolding arrangement as per site condition, Supply of necessary Refrigerant, connecting Control & power cabling & other necessary materials to complete the job. |
| 39 | 7.5 TR Ceiling Flexi Concealed type Split AC |
| 40 | 5.0 TR Ceiling Flexi Concealed type Split AC |
| 41 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for the system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required [Cu. Pipe Make :Nippon/Ryoku/Rajco](Insulation Make- AFlex/ Aerocell/ Accoroflex/ Suprime) |
| 42 | 15.86 mm(5/8\\") dia (OD)with tube thickness for Suction line with 9 mm thick nitrile insulation |
| 43 | 9.52 mm(3/8\\") dia (OD)with tube thickness for Suction line with 9 mm thick nitrile insulation |
| 44 | 32 mm NB Rigid PVC pipe with 6 mm thick Nitrile Rubber Insulation for AHU Drain pipe up to nearest drain point(Make-Supereme/Oriplast/Finolex) |
| 45 | 25 mm NB Rigid PVC pipe with 6 mm thick Nitrile Rubber Insulation for AHU Drain pipe up to nearest drain point(Make-Supereme/Oriplast/Finolex) |
| 46 | COMUNICATION CABLE-Supply & laying of PVC- Sheathed cable for Control cables. Make: RR/ Kable/Polycab/Finolex/Nicco4 Core 1.5 sqmm XLPE Cu Cable |
| 47 | Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making Base Frame for installation of outdoor unit of 7.5 Tr Concealed Split AC & High wall split incl. drilling holes in each channel, cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm as per direction of E.I.C. |
| 48 | Charges of Civil work like wall cutting & mending |
| 49 | Supplying, fitting & fixing in position suspended boxing for Concealed AC Machine with frame work of aluminium hollow section of size 50mm x25mm (1.1mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm ,25mm x 25mm powder coated wall angle with aluminium composit panel(ACP- Make-Aludecor/Protap Bond) of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of EIC. |
| 50 | Charges of trapdoor made by ACP Board |
| 51 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cellelastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS typecopper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe,and wireless remote control with suitable battery. The system shall operate on230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply,providing cooling, dehumidification, and air circulation functions conforming toIS-1391 (Part-II ) with all amendments, and shall be capable of efficientperformance at outdoor ambient temperatures up to 50°C or heigher, with a minimum 5-year OEM warranty on PCB. and minimum 10-year OEM warranty on the compressor and The system shall be installed with S&F appropriate fixing arrangements as per OEMrecommendations, including wall openings, mending well the damages andmaking necessary connections including T&P & labour etc as required completein all respect as per the direction of EIC. (Make : Mitshubishi Heavy Industries / Mitshubisi Electric/ OGeneral) |
| 52 | Cooling Capacity- 5.2 kW (Minimum) , Air Flow Rate:600 CFM (Minimum)Minimum ISEER - 5.0, BEE level - 4-Star(min) [OG-AS/AO-GG18CGAB-B (R32)/Mitshubishi Electric-MSY/MUY-GN18VF or equivalent Model/series of Mitshubishi Heavy Induatries] |
| 53 | Cooling Capacity- 6.6 kW (Minimum) , Air Flow Rate:800 CFM (Minimum)Minimum ISEER - 5.0, BEE level - 4-Star(min) [OG-AS/AO-GG24CGAA-B (R32)/Mitshubishi Electric-MSY/MUY-GR22VF or equivalent Model/series of Mitshubishi Heavy Induatries] |
| 54 | Supplying, Installation, testing and commissioning including vaccumiazation andNitrogen testing of following nominal sizes of soft/hard drawn copperrefrigerant piping for VRV/VRF system, complete with fittings, with suitableadjustable ring type hanger supports, jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cellelastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation asgiven below for Suction and Liquid lines, all accessories as per specifications etc.as required : |
| 55 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 56 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 57 | S&F of additional following items for length exceeding 3.5 mtr for completeinstallation and commissioning of aboove AC machines.i) 2.5 sqmm, 3/4 core copper cable (FRLS type) |
| 58 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports &brackets as per direction EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender