Housing Urban and Rular Development Government Departments Closing in 5 days TDR #56416461

Tender For annual repair & maintenance of Of annual maintenance contract For Electrical Works At Dseu Ranhola C Us Dg. Fy 2026-27.

Issued by Government Departments · Delhi, Delhi
Tender Value
28.88 Lakhs
Estimated cost
Bid Submission
17 Jul 2026
5 days left
EMD
57774
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for annual repair & maintenance of Of annual maintenance contract For Electrical Works At Dseu Ranhola C Us Dg. Fy 2026-27.

BOQ

Name of Work:- A/R & M/O of AMC for Electrical Works at DSEU Ranhola C us dg. FY 2026-27.
Sl. No. Item Description
1SH:-1 Maintenanace & EIDay to day Maintenance of all electrical installation with fixtures, Circuit, Submain, Distribution boards, Main boards, Security lights by deputing technical staff on all days excluding sunday & Holiday on monthly basis in General shift and as per Terms and Conditions attached:-Staff Details:-
2Wireman - 1 No. (Shift- General)
3Khallasi - 1 No (Shift- General)
4Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
5Group C
6Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class ofinsulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
71200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
8Supplying of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
936 Watt
10Supplying, Installation, Testing and Commissioning of 300 mm Sweep fresh air PVC body exhaust fan minimum 1300rpm including louvers and shutter, fixing with suitable arrangement, connection with 1.5 sq.mm. FRLS PVC insulated wire complete etc. as reqd.
11Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of inimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
1272 watt
13Supplying of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
1412 -15 watt
15SH:-2 RO MaintenanceComprehensive maintenance of 50x4nos LPH R.O. System with Water Cooler i/c two mandatory services per month (cleaning of All Filters), attending complaints within 24 working hours and replacing the defective parts including Tee, Elbow, PVC pipe with complete overhauling and servicing, excluding filter and cartridge,membrane etc. as required.
16Supply & Replacement of following items & extra consumables for testing, commissioing for above R.O. System as & when required.
17Spun filter 20\\"
18Carbon filter/CTO 20\\"
19Adaptor 48 volts
20Pump K48
21Cartridge filter 10\\"
22R.O. Membrane 80 GPD
23SH:-3 Figher Fighting MaintenanceDay to day operation & Maintenance of fire fighting system and fire alarm system complete with wet riser fire pump motors, hydrants i/c water supply pump sets all days i/c sundays and holidays with following minimum staff.
24Wireman - 1 No. (Shift- General)
25Khallasi - 1 No (Shift- General)
26Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 offollowing sizes as required :
27100 mm dia
28Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :a) One or more coats on old work.
29(a) Dismantling of existing Kirloskar make following capacity Fire Fighting Centrifugal Pump set by part to part with special tools including uncoupling the pump from existing motor, opening of all nuts & bolts of upper casing and motor foundation bolts to facilitate lifting of impeller assembly from lower casing with the help of chain pulley block / heavy labour, loading and unloading of pump from site to workshop and back including labour & cartage etc. complete as required and with the entire satisfaction of Engineer-in-charge.(b) Servicing, overhauling, re-conditioning and re-commissioning of existing Kirloskar make following capacity Fire Fighting Centrifugal Pump set after dismantling the bearing of pump and motor with the help of bearing puller, checking of impeller, mechanical seal, oil seal and all other parts and replacement of all defective parts i.e. Ball Bearing, Mechanical Seal, Shaft Sleeve and minor parts such as nut-bolts, washers, thimbles, sleeves and adjustment/alignment of impeller complete with varnishing connections, testing etc. as required and with the entire satisfaction of Engineer-in-charge (Buy back of scrap are included)
30Mechanical Pump of 12.5 HP
31Supply, Installation, Testing and Commissioning (SITC) of 12.5 HP Monoblock Centrifugal Pump, complete with TEFC induction motor suitable for continuous duty, having cast iron casing and dynamically balanced impeller, designed to meet required discharge and head, mounted on base frame with anti-vibration pads including alignment and grouting, complete with suction and delivery connections, NRV, valves, foot valve with strainer (if required), pressure gauges, suitable starter, cabling, earthing, and all accessories, including testing, trial run and commissioning, conforming to relevant IS standards and approved makes, complete as required.
32Refilling and servicing of various type of fire extinguishers as per IS specification including with testing commissioning at site i/c cartage of extinguisher for site refixing back i/c pdg. Instruction label and inspection slip complete as per required.
33CO2 type fire extinguisher of 4.5 kg capacity
34ABC type fire extinguisher of 6 kg capacity
35Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd.for suitable dia MS pipe connection conforming to IS 904 as required:
362 way-100 mm dia M.S. Pipe
37Providing and fixing in position industrial type pressure gauges with gun metal / brass valves complete etc. as required.
38Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
39Supplying and charging of R-22 R-410//R-134 or any other required refrigerant gas as per requirement in 1.5/ 2TR capacity WTAC/Split AC unit i/c necessary copper pipe, capllary & fiter i/c brazing the tube leakage, finding, pressure testing and vacummuizzing complete as required.
40Servicing and complete overhauling of WTAC/Split units after dismantling from various locations, removing of dust from condenser coil, cooling coil and chasis wherever required complete cleaning of fin condenser coil with cleaning agent of superior quality, dismantling of blower motor (if required), washing etc after dismantling of condenser motor replacement of defective parts finally applying two coats of black synthetic paint of approved brand before fixing new 5 mm./6 mm. foam sheet with adhesive testing commissioning etc. complete as reqd.
41Fabricating, Supplying & Fixing wire mesh protection frame work made out of 40 mm x 6 mm thick angle & \\"T\\" strengthened with intermediate members of MS flat iron of size 30 mm x 5 mm thick welded at a distance of 30 cm horizontally & vertically and duly welded with wire mesh of size 75 mm x 25 mm made with 6 SWG wire mash of size 75 mm x 25 mm made with 6 SWG wire on all sides and top i/c providing and fixing of double door gate with double locking arrangement ( Two Nos. sliding bolts and One No go down lock) having 0.5 mtr. long legs of 40 mm x 40 mm x 6 mm thick angle iron, duly grouted in cement concrete foundation ration 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate), up to suitable depth painting with one coat of red oxide & Two coats of synthetic enamel paint of approval colour and shade etc. complete as reqd.
42Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
43Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
44Upto 35 sq. mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56416461
AUTHORITY Government Departments
TENDER VALUE 28.88 Lakhs
LAST DATE 17-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for annual repair & maintenance of Of annual maintenance contract For Electrical Works At Dseu Ranhola C Us Dg. Fy 2026-27.
Basic Detail
Tender No 04/EE(E)/WED/PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 10 Jul 2026
Submission Date 17 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 28.88 Lakhs
Tender Fee Ref. Documents
EMD 57774
Exemption Not Available
Document List
2e819500-ab3b-45f9-9be2-845f7c57788a.html
BOQ_392755.xls
NIT-SECONDCALL.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

2e819500-ab3b-45f9-9be2-845f7c57788a.html

xls

BOQ_392755.xls

pdf

NIT-SECONDCALL.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders