Housing Urban and Rular Development Government Departments Closing in 3 days TDR #56416367

Tender For Deposit-Museum And Zoo, Tvpm - Replacing Of Defective Electrical Panel Board At Pump House In Connection With Providing New Retaining Wall And Renovation Of Pump House-Providing Ei-General Electrical Work

Issued by Government Departments · Thiruvananthapuram, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Jul 2026
3 days left
EMD
7139
Bank guarantee accepted
Document Fee
630
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Deposit-Museum And Zoo, Tvpm - Replacing Of Defective Electrical Panel Board At Pump House In Connection With Providing New Retaining Wall And Renovation Of Pump House-Providing Ei-General Electrical Work

BOQ

Name of Work:- DEPOSIT-Museum and Zoo, Tvpm - Replacing of defective electrical panel board at pump house in connection with providing new retaining wall and renovation of pump house-Providing EI-General Electrical Work
Sl. No. Item Description
1Providing EI
290.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
390.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
49.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
590.14.3.3:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board
690.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
790.14.7:Supply and providing copper earth bus in the panel board
8OD72578/2026-2027:Supply, conveyance and fixing the following types & current rated control gears & switchgears Conforms to IS/IEC 60947-2 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL (L&K make DN1-250C or equivalent)
990.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
10OD72579/2026-2027:Supply, conveyance and fixing the following types & current rated control gears & switchgears Conforms to IS/IEC 60947-2 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL (L&K make DN1-250C or equivalent)
1190.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
12OD72594/2026-2027:Supply and fixing Fully automatic star delta motor starter for 10HP motor
13OD72595/2026-2027:Supply and fixing Three phase DOL Motor starter for 0.25HP to 7.5 HP motor
1490.14.24.3:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.3 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type suitable for direct connection to motors.
15OD258378/2024-2025:Supply and fixing of Red,Yellow, Blue colours LED indicator,AC/DC,22.5 mm cut out dia and its connected accessories as required.
165.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
175.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
18OD72582/2026-2027:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
1990.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
2090.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
21OD268118/2024-2025:Supply, Installation, Testing and commissioning of 150/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT as required
22OD268133/2024-2025:supply and fixing of multi function meter to read VA,PF,KW,KWh, accuracy class-1 LCD with necessary connected item as required
23OD268235/2024-2025:Supply and fixing of Blue colour LED indicator, AC/DC, 22.5 mm cut out dia and its connected accessories as required
242.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
25OD267511/2024-2025:Painting letters or figures of the following sizes with enamel paint as identification mark to the fire extinguisher etc. as required. 2.5 cm, 4 cm, 5 cm height
26OD267510/2024-2025:Supply and fixing of ELECTRICAL INSULATION RUBBER SHEET AS PER IS-15652-2006 CLASS A-2MM THICKNESS 1 meter width and 2 meter length as required.
2790.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
2890.14.29.3:S & F Motor starters accessories of the followingPush button station for starters
29OD72583/2026-2027:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.1.50sq mm wire single run
30OD297898/2024-2025:Supply and Fixing of Bakelite Fuse Base 20A with HRC Fuse Link 2A and givingconnection as required
31OD297907/2024-2025:Supply and fixing Spreader terminals suitable for 250A 4Pole MCCB (Set of 8) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56416367
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 16-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Deposit-Museum And Zoo, Tvpm - Replacing Of Defective Electrical Panel Board At Pump House In Connection With Providing New Retaining Wall And Renovation Of Pump House-Providing Ei-General Electrical Work
Basic Detail
Tender No PWD/BLDG/TR/2768/2025
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 10 Jul 2026
Submission Date 16 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 630
EMD 7139
Exemption Not Available
Document List
affi.pdf
agree.pdf
BOQ_1454328.xls
cec151e8-feb1-437e-abf6-a982af12747c.html
epayment.pdf
form.pdf
IP.pdf
make.pdf
Tendernotice_1 (10).pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
pdf

affi.pdf

pdf

agree.pdf

xls

BOQ_1454328.xls

html

cec151e8-feb1-437e-abf6-a982af12747c.html

pdf

epayment.pdf

pdf

form.pdf

pdf

IP.pdf

pdf

make.pdf

pdf

Tendernotice_1 (10).pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders