Tender For special Rep To Roof Treatment Of Bldg P-01,P-03, P-04, P-05 Of 960(I) Tk Asc Pl And special Rep To Roof Sheet, Trusses, False Ceiling And Misc Works Of Bldg T-126 And Certain Provn Works Of 11 Mech At Old Cantt Under Ge Kapurthala
Tender Overview
Project Description
Tender for special Rep To Roof Treatment Of Bldg P-01,P-03, P-04, P-05 Of 960(I) Tk Asc Pl And special Rep To Roof Sheet, Trusses, False Ceiling And Misc Works Of Bldg T-126 And Certain Provn Works Of 11 Mech At Old Cantt Under Ge Kapurthala
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Spl rep to roof treatment of Bldg P-01,P-03, P-04, P-05 of 960(I) TK ASC PL and Spl rep to roof sheet, trusses, false ceiling and Misc works of Bldg T-126 and certain provn works of 11 Mech at old cantt under GE Kapurthala Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil. |
| 3 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and getting out complete all as specified. |
| 4 | M&L for cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate for foundations, fillings and mass concrete all as specified and directed. |
| 5 | Demolition of brick / block masonry built in cement mortar including all quoins, arches, pillars etc and clearing off the premises. |
| 6 | M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 concrete all as specified and directed. |
| 7 | Demolition of brick / block masonry built in cement mortar including all quoins, arches, pillars etc and clearing off the premises. . |
| 8 | Taking down cement plaster on brick work or concrete surfaces incl racking out joints all as specified. |
| 9 | M&L for 12 mm thick rendering on brick work or concrete surfaces in cement mortar 1:6 complete all as specified and as directed. |
| 10 | M&L for 15mm thick rendering on fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 with water proofing compound complete all as specified and as directed.Note:- water proofing compound shall be measured and paid seprately. |
| 11 | M&L for applying two coats of exterior emulsion (Apex) paint on newly plastered or unplastered wall surface over a coat of primer including preparation of surfaces, complete all as specified and as directed. |
| 12 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similat pattern roof sheets in roof coverings. |
| 13 | M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 14 | M&L for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 15 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/slabs/blankets/AC boards etc any thickness. |
| 16 | S&F in posotion suspended false ceiling system using E-grid suspended ceiling grid system. The size of grid shall be 600x600mm with GI frame work main runner 38x24mm cross tee 25x24mm and wall anlge 24mmx24mm using 9mm thick ceiling panel laminated with pvc film on front face and foil back available in due drop teture as per IS-2095 Part-I 1996 fixed in the the grid of E grid suspended ceiling grid system duly suspended by 4mm dia GI bar hangers from the purlins of the roof with butter fly clips complete all as specified and as directed. |
| 17 | M&L for preparation of new plastered surfaces of walls and applying two coat of birla white putty to obtain the true line to achieve smooth surface and applying two coats of oil bound distermper complete all as specified and directed. |
| 18 | M&L for applying two coats of exterior emulsion (Apex) paint on old plastered or unplastered wall surface after complete removal of existing treatment complete all as specified and as directed. |
| 19 | M&L 75mm thick PCC 1:3:6 type C2 as in plinth protection/hard standing finishing the surface even and smooth with out using extra cement complete all as specified and as directed. |
| 20 | Dismantling of brick tiles or terracing tiles laid bedded and pointed in cement mortar in single layer on roofs complete all as specified and as directed. |
| 21 | Demolition of mud in roof any thickness including plastering & leeping removed as directed. |
| 22 | Material and labour for75 mm thick Cement concrete type B0, 1:2:4 (using 12.5 mm graded stone aggregate) as in PCC padding over roof slab complete all complete all as specified. |
| 23 | M&L for rendering 10mm thick cement mortar 1:3 on concrete surface even and smooth with waterproofing compound complete all as specified and as directed. |
| 24 | Supply only integral water proofing compound. |
| 25 | M&L for preparation of newly plastered surface making surface completely dry after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymericweighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers with a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm under the APP membrane laid with torching application to the surface complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) complete and applying two coats of aluminium paints on APP all as specified and directed. |
| 26 | M&L for cement concrete type B0 1:2:4 (12.5mm graded aggregate) in roof kerbs, rounded or chamfered edges complete all as specified and directed. |
| 27 | Taking down chowkats or framed with shutter (with out taking off shutters from the frame) area exc 1.50 sqm but n. exc. 4 sqm each. |
| 28 | S&F of powder coated of any colour (thickness of p[owder coating not less than 50 micron) Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed. |
| 29 | S&F of powere coated (Minimum thickness of powered coating 0.50 micron)Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc; complete all as specified and as directed. |
| 30 | S&F of poweder coated (Minimum powered coating thickness 0.50 micron)Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc; complete all as specified and as directed. |
| 31 | S&F of 5.50mm thick plain sheet glass, one side sheet glass is groundor obscured or frosted in squares exc 0.5 sqm each pane and glazing with metal beads complete all as specified and as directed. |
| 32 | S&F in repairs aluminium (die cast body) Door closer hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 33 | M&L for stainless steel wire cloth 0.56mm nominal dia of wire and avarage width of aperture 1.40mm and fixed with tinned tacks/screws with bolts incl leaping wooden. |
| 34 | Form work to sides and soffits of floor, Plinth beam or roof beams, beam haunching, lintel etc rough finished surfaces of concrete flats. |
| 35 | M&L for RCC M-25 design mix as in lintel beam,Roof Beam, cantilivers, bressummers, lintel over 1.5m span complete all as specified and as directed. |
| 36 | M&L for TMT bars (Fe 500),10 mm dia and over in reinforcement cut to length, bent to shape required incl bending spirally cranking, hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 37 | M&L for TMT bars (Fe 500), 5mm dia and over upto incl 10mm dia stirrups bending spirally or hooping for columns, hooking ends and binding with mild sleet wire not less than 0.90mm dia complete all as specified and directed. |
| 38 | S&F in repair stainless steel 20mm dia curtain rail chromium plated with fixing brackets, stops, roller etc; complete all as specified and as directed. |
| 39 | S&F of CPVC pipe of outer dia 16mm SDR 11 & Plain CPVC SDR 11 fittings / adhesive(solution) on walls/ceiling or laying in floor complete all as specified and directed. |
| 40 | S&F of CPVC pipe of outer dia 20 mm SDR 11 & Plain CPVC SDR 11 fittings / adhesive(Solution) on walls/ceiling or laying in floor complete all as specified and directed. |
| 41 | S&F of vitreous china ware wash basin white, flat back size 550 X 400mm with pedestal including 15mm dia swain neck pillar tap chromium plated, CP waste coupling, waste fittings, union and waste pipe 32mm dia or required length and all necessary inlet, out let connections complete all as specified and as directed. |
| 42 | S&F stainless steel rack for kitchen utensil made out of 22 gauge sheet & overall size 900mm x 750mm fixed to wall with screws complete all as specified and directed. |
| 43 | S&F fancy type chromium plated stop valves/angle valves with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed for bore fo size 15mm complete all as specified and as directed. |
| 44 | S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 45 | M&L for plain cement concrete (1:5:10) type E-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed. |
| 46 | M&L for sand filing under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 47 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658 - 2006 of 80mm thick ness, M-40 grade with grey cemet and pigment over sand cushioning complete all as specified. |
| 48 | M&L for precast cement concrete block masonary with solid block (size 30x20x10 cm) as in edging, type B1 1:2:4 (20 mm graded aggregate) exc 10cm in width and setting in cement mortar 1:4 complete all as specified and as directed. |
| 49 | M&L for RCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in chajjas, shelf etc; complete all as specified and directed. |
| 50 | Use and waste of formwork to chajjas and similar items including edges rough finished complete all as specified and directed. |
| 51 | Dismantiling water tank PVC 500Ltrs and removing from site |
| 52 | S&F rotational moulded polythelene water storage tanks cylindircal water tank for hoisted and fixed in postion of 500 ltrs capcity including fittings complete all as specified and as directed. |
| 53 | S&F for gunmetal globe and gate valve with iron welded hand secrewed both and for iron pipe 20mm fixed in repairs complete all as specified and as directed. |
| 54 | S&F in repairs steel work in tubular trusses including special shaped washer etc; complete using ERW or induction butt welded tubes conforming to I.S.1161 1979 grade St.-240 as in purlin, rafter and truss complete all as specified and as directed. |
| 55 | M&L for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 56 | Removing excavated material n.exc.50m and depositing where directed at a level n exc1.5m above the starting point complete all as specified and as directed. |
| 57 | Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and as directed. |
| 58 | Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc; complete all as specified and directed. |
| 59 | M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC (FR) insulated cable in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.5 Sqmm insulated un-sheathed PVC insulated copper conductor common earth and connecting to earth dolly for :- |
| 60 | One light point controlled by one, one way switch |
| 61 | One fan point controlled by one, one way switch |
| 62 | One socket outlet 3 Pin, 5 Amp on independent board |
| 63 | One socket outlet 3 Pin, 5 Amp on same board. |
| 64 | M&L for point wiring with 4.00 Sq mm single core multi-stranded copper conductor PVC (FR) insulated, unsheathed cable 1100 volt grade in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.50 Sq mm single core, multi-stranded copper conductor, PVC insulated, unsheathed cable for common earth and connecting for earth dolly for 5 pin, 15 Amp socket outlet on Independent board complete all as specified and directed. |
| 65 | S&F of switch piano flush type single pole one way 5 Amp (ISI Marked) |
| 66 | S&F of switch piano flush type single pole one way 15 Amp (ISI Marked) |
| 67 | S&F of socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked) |
| 68 | S&F of socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) |
| 69 | M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body complete all as specified and directed. |
| 70 | Taking down old unserviceable flourescent tube light fitting 36/40 watt fluorescent tube light fittings direct to walls or roof as ordered and disconnecting electrically with the electrical system and all materials required for the same. The rates also include making good the same to match with the existing surface. |
| 71 | Supply, installation, testing and commissioning of 20 watt 4 ft long LED batten complete all as specified and directed. |
| 72 | Taking down old unsv DB and supply and fixing MCB DB Triple pole and neutral 4 way with 200 Amps rated busbar complete all as specified and directed. |
| 73 | S&F of MCB, 10 to 32 Amp, SP, 240 Volt complete all as specified and directed. |
| 74 | S&F of MCB, 40 to 100 Amp, TPN, 415 Volt complete all as specified and directed. |
| 75 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc; complete all as specified and directed. |
| 76 | S&F of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 77 | S&F of LED Bldg security light fitting 35 W housing made out of die cast aluminum alloy with toughed glass, IP 65/66 protection having clamp for mounting on wall working on 240 V AC 50 Hz, 20 watts including fixed on wall with 02 Nos MS clamps and bracket made of 40 mm dia light grade GI pipe bend to shape. complete all as specified and as directed. |
| 78 | S&F of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 79 | Supply, installation, testing, commisioning of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored electric power cable heavy duty with standarded aluminium conductor 1100 volts grade for earthed system of sizes 10 Sqmm 4 core complete all as specified and directed. |
| 80 | M&L for octagonal poles hot dip galvanized steel (IS 5986 Gr. Fe 510) octagonal pole 7.0 m long, top top die 70 mm botom dia 130 mm having thickness 3 mm having door operating of size 500 mm above ground level with CI Base plate of size 240x240x16mm having PCD 220 mm foundation J bolts M20 x 70 mm (530 + 130 of J) nuts and screwes and having hot dip galvanized double plain arm bracket 1000 mm overhang on both side or 45o with 48.3 mm outer dia pipe of thickness 3.2 mm fixed on top with bolts and necessary earth work RCC with steel reinforcemet work for the foundation of pole, including necessary form work and fare finish to exposed surfaces without using extra cement etc; complete all as specified and directed. |
| 81 | S&F of LED street light 60W IP 65 including all accessories and fixing arrangements complete all as specified and directed. |
| 82 | Supply, fixing and connecting 3 core, 1.5 sqmm PVC insulated round sheathed, multicore annealed bare copper conductor(flexible) industrial cable for voltage grade 1100 volts IS-694: 2010 complete all as specified and directed. |
| 83 | M&L for old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed. (for LT Cable ) |
| 84 | Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene including coupler and bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents