Tender for Addn/ Altn/ Improvement Of Security Infrastructure At Af Stn Mohanbari
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and laying APP based modified water proofing polymeric membrane, reinforcemed with nonwoven polyester fabric matt (weight not less than 150 gms/sqm) of minimum 3 mm thick and minimum weighing not less than 3 kg/sqm,laid over bituminous primer on 15mm thick plastered sufaces layer in cement mortar 1:4 with water proofing compound (WPC )@3% by weight on concrete surface roof / parapet, over lap of minimum 75 mm on longitudinal direction and 100 mm on the transverse direction by thermo-fused torch flame application method and top surfaces to be treated with two coat of aluminium paint @0.15 Kg/Sqm all as per manufacturers instructions as complete all as specified and directed. |
| 2 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed. |
| 3 | S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) of Fe 410-W (Gde E250) quality-A including distance pieces, cleats etc complete all as specified and directed. |
| 4 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed basescreed bed or bedding laying of cement mortar (1:4) 15 mm thick for as in floor finisheslaid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 5 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over backing coat of cement mortar 1:4 ,10 mm thick for as in vertical surfaces and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 6 | M&L for 5 mm thick rendering in cement mortar (1:3) on fair faces of concrete surfaces such as soffits of slabs, in patches n exc 1 sqm each finishing the surfaces fair and even complete all as specified and directed. |
| 7 | Preparation of new or previously untreated steel surface of any discription over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and directed. |
| 8 | M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of new surafaces complete all as specified and directed. |
| 9 | Taking down chowkats or frames n.exc 1.5 Sqm each with shutters (without taking off shutters from the frame complete all as specified and directed. |
| 10 | Taking down chowkats or frames exc 1.5 sqm but not exc 4 Sqm each with shutters (without taking off shutters from the frames complete all as specified and directed. |
| 11 | Taking down shutter of any description, exc 1.00 square mtr and not exc 2.00 mtr each complete all as specified and directed. |
| 12 | Dismantling floor health or wall tiling including cement mortar bedding (but not backing) and removing debris, etc to a distance exc 50.00 Mtr but n.exc 100 Mtr complete all as specified and directed. |
| 13 | Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc and removing debris, etc to a distance exc 500 Mtr but n.exc 100 mtr complete all as specified and directed. |
| 14 | Taking up or down steel tubing 15 mm bore (dia) and fitting connections of any description from any situations complete all as specified and directed. |
| 15 | Taking up or down steel tubing 20 mm bore (dia) and fitting connections of any description from any situations complete all as specified and directed. |
| 16 | Taking up or down PVC(SWR) soil, waste and ventilating pipe upto 110 mm bore dia with fitting of any description from any situations complete all as specified and directed. |
| 17 | M&L for second class hardwood (well seasoned) plain, solid, straight, chowkats and frame wrought frames rebated on the solid, Rounded or chemfered, put together with glue pinned at joints complete all as specified and directed. |
| 18 | M&L for factory made plain framed, panelled shutter 35 mm thick (two panels) with lock rail and panel 9.0 mm thick BWP, commercial Ply or 12mm thick veneered particle board with commercial veneering on both faces, having sizes of rails and stiles as per IS:1003 (Part I) of second class Hardwood (Kiln seasoned & Chemically pressure treated) and fitted to chowkats complete all as specified and directed. |
| 19 | M&L for second class hardwood (well seasoned) Glazed and skelton shutter 35 mm thick, open rebated and prepared to receive gauge, glass etc. Divide into squares, with plain, chemfered or rounded, mitred and rebated sash bars, any numbers, sizes of members of shutter as specified as per ssr Part -I, section 8, clause 8.24(a) and fitted to chowkats complete all as specified and directed. |
| 20 | S&F for solid PVC Door Frame of size 50x47mm made out of 5.0mm Plain Colour PVC Sheet reinforced with Mild Steel Square Tube and fixing in Opening complete all as specified and directed. |
| 21 | M&L for Factory Made Solid Panel PVC Door Shutter 30mm thick (Style) Plain Colour (Ivory shade) consisting of Frame made out of Mild Steel Tubes for Top and Bottom Rails, Mild Steel Frame shall be covered with heat moulded wood grain PVC ‘C’ Channel having a PVC Sheet Strip of 20mm width stuck inside with Solvent Cement for Stiles and Wood Grain PVC Sheets for Top Rail, Lock Rail & Bottom Rail on either Side and as gap insert for Top Rail & Bottom Rail, Panelling of Wood grain PVC Sheet to be fitted in the Mild Steel Frame welded/sealed to the Stiles and Rails with suitable 5mm thick x 15mm wide PVC Sheet Beading used inside Stiles and Rails and decorative PVC Beading of 10mm x 10mm (90°) and jointed together with Solvent Cement and fixing in the Frame and hanging/ fixing with and including Stainless Steel Hinges complete all as specified and directed.NOTE : Butt Hinges will be Measured and Paid Separately. |
| 22 | M&L for Powder Coated (Minimum thickness of Powder Coating 50 Micron) Aluminium Ventilator Frame having Frame of Section 100x44mm of thickness 1.6mm Shutters of Section 32x15mm (with and including Half Portion fixed Glazed Shutter and Rest Half Portion Louvered with Glazed Shutter) including Stainless Steel Wire Mesh, Rubber Gasket for Securing the Glass 5.5mm thick Figured Glass, Aluminium Grill and necessary Aluminium Mongery and Handles including necessary Locking Arrangement complete all as specified and directed. |
| 23 | M&L for Powder Coated (Minimum thickness of Powder Coating 50 Micron) Aluminum Sliding Windows 2-Tracks with 2 Sliding Shutters with Extrusions Aluminum of following Sections including Jointing Cleats, Glazing Clips, Rubber Packaging, Snap Beading and other necessary Aluminium Builders Hardware as required complete all as specified and directed :- A. FRAME :-(i) Top and Side Member for 2 Track Frame of Size 61.85x31.75x1.5mm (Weighing 0.784 KG/RM), Model No. 20829 of Make : Jindal or equivalent.(ii) Bottom Rail of Frame for Sliding of Size 61.85x31.75x1.5mm (Weighing 0.909 KG/RM), Model No. 20830 of Make : Jindal or equivalent.B. SHUTTER :-(i) Top and Bottom Rail of Sliding Shutter of Size 40x18x1.5mm (Weighing 0.547 KG/RM), Model No. 20736 of Make : Jindal or equivalent. (ii) Side of Sliding Shutter with Handle and Self Locking Arrangement, Section of Size 40x18x1.5mm (Weighing 0.547 KG/RM), Model No. 20738 of Make : Jindal or equivalent.(C) Sliding Shutter to be provided with 5.0mm thick Sheet Glass.(D) Aluminum Diamond Grill 6.5mm thick with Mat Finished fixing on Wall/ Wooden Chowkat/ Aluminium Frame with suitable Size of Aluminum 'U' Channel and Steel Chromium Plated, Screw with Rawel Plug with following Details :-(i) Aperture Size of Aluminum Grill 67x84mm.(ii) Cord Dimension 7.0x5.8mm.(iii) Plate thickness 3.0mm.(E) Stainless Steel Wire Cloth, 0.36mm Nominal Dia of Wire and Average Width of Aperture 1.40mm and fixed with Stainless Steel Wire Staples/ Clip/ Aluminium Flat |
| 24 | S&F for Aluminium anodised Barrel Tower Bolt, 150mm long, Extruded Section complete all as specified and directed. |
| 25 | S&F for Aluminium Alloy Anodized Sliding Door Bolt 300mm Long with Hasp Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Section and fixing Bolts and Sliding Bolts of Extruded Section and Fixed complete all as specified and directed. |
| 26 | S&F for 75mm Size (as approved) Stainless Steel Butt Hinge and Fixing to PVC Door Shutter complete all as specified and directed. |
| 27 | S&F for 100mm size Mild Steel Butt Hinge, Medium Weight, Cold Rolled and fixed Shutter complete all as specified and directed. |
| 28 | S&F for Continuous (Piano) Hinges, Width of Flaps (when open) in 30mm, Mild Steel, Bright Finish or Electro-galvanised and Fixed-in-repairs complete all as specified and directed. |
| 29 | S&F for 150mm long Aluminium Handle, Cast type, anodised, Extruded and fixed complete all as specified and directed. |
| 30 | S&F for Mild Steel Curtain Rod/ Harrison Rail 20mm Dia, Chromium Plated with Brackets, Stops, Rollers, fixed on Walls and Fixed-in-repairs complete all as specified and directed. |
| 31 | M&L for Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples complete all as specified and directed. |
| 32 | S&F for Plywood 12mm thick, Grade BWR, Type BB, fixed with Screws to Timber Frame Work, complete all as specified and as directed. |
| 33 | S&F for Pre-laminated Particle Board 18/19mm thick, Interior Grade, Pre-laminated One Side with Decorative Choice Lamination and Other Side Balancing White Lamination, fixed with Screws to Timber Frame Work complete all as specified and directed. |
| 34 | M&L for Joint Free Non-Skid Ceramic Coloured Tiles 7.0mm to 8.0mm thick (Rectangular or Square), Area of Each Tile exc. 0.06 Sqm but not exc. 0.11 Sqm (1st quality) in Floors, Set and Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Screed or Screed Bed 15mm thick in cement mortar 1:6 complete all as specified and directed. |
| 35 | M&L for Glazed Ceramic Coloured/ Printed Tiles 450x300x7.0mm thick in Vertical Surfaces i.e. Dado, Skirting, etc Set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Screed or Screed Bed 10mm thick in cement mortar 1:4 complete all as specified and directed.Note : Cost of Screed Bed will deem to be included in the Quoted Unit Rate. |
| 36 | M&L for Green Marble Work 18mm to 20mm thick (Table Rubbed and Polished) in Steps, Jambs, Pillars, Window Cills, Cooking Platforms and like in Cement Mortar 1:4 including Pointing in White Cement 1:2 Using Marble Dust with Admixture of Pigment to Match the Shade of Marble including Grinding and Polishing, Fixing over and including 20mm thick Cement Screed Bed in Cement Mortar 1:6 complete all as specified and directed.Note : Cost of Screed Bed will deem to be included in the Quoted Unit Rate. |
| 37 | M&L for 10mm thick rendering in cement mortar 1:6 on brick or concrete surfaces, finished plastered surfaces even and smooth without using extra cement complete all as specified and directed. |
| 38 | M&L for 15mm thick Rendering on Bricks or Concrete Works consisting in 2 layers, Back/ Under layer of 10mm thick in Cement Mortar 1:6 and Float/ Top layer 5.0mm thick in Cement Mortar 1:4 including Mixing WPC to Float/ Top finished Plastered Surfaces Even and Smooth without using Extra Cement complete all as specified and directed.Note : Water Proofing Compound (WPC) will be Measured and Paid separately under relevant item here-in-below. |
| 39 | Supply only Water Proofing Compound (as approved), conforming to IS:2645-2003 complete all as specified and directed. |
| 40 | M&L for preparing new plastered surfaces on salls, spplying 1.5mm thick sall sare putty including cutting/ rubbing down to obtain an even and smooth surface, spplying two coats of distemper oil emulsion (as approved) over a coat of alkali resistant priming paint complete all as specified and directed. |
| 41 | M&L for preparing newly plastered surfaces of walls and applying two coats of acrylic based weather coat exterior grade emulsion paint (any tinted) in camouflage pattern over a coat of suitable primer (as specified by manufacturer of paint) including cleaning drops from Joinery, glasses, electrical fittings and washing floors etc complete all as specified and directed. |
| 42 | M&L for applying two coats of synthetic enamel paint (1st grade quality paint of as approved tint) over a coat of pink primer after preparing new wooden surfaces of any description, over 10cm in width or girth complete all as specified and directed. |
| 43 | S&F for CPVC pipe 20mm outer dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in Floors complete all as specified and directed. |
| 44 | S&F for brass elbow suitable for CPVC Pipe 20mm Outer dia, SDR 11, complete all as specified and directed. |
| 45 | S&F for brass Tee suitable for CPVC Pipe 20mm Outer dia, SDR 11 complete all as specified and directed. |
| 46 | S&F for male brass threaded adaptor (MTA/ MBTA) suitable for CPVC pipe 20mm outer dia, SDR 11 complete all as specified and directed. |
| 47 | S&F for female brass threaded adaptor (FTA/ FBTA) suitable for CPVC pipe 20mm outer dia, SDR 11 complete all as specified and directed. |
| 48 | S&F for Union suitable for CPVC Pipe 20mm Outer dia, SDR 11 complete all as specified and directed. |
| 49 | S&F for 20mm bore (dia) galvanised steel tubing \\"medium grade\\", conforming to IS-1239 with all fittings, fixed to walls, ceiling or laid in floors complete all as specified and directed. |
| 50 | S&F for bib tap 15mm bore (dia) cast copper alloy, chromium plated, fancy type with crutch or butter-fly handle, screwed down, screwed for Iron pipe or for brass ferrule and fixed-in-repairs complete all as specified and directed. |
| 51 | S&F for pillar tap 15mm bore (dia), cast copper alloy chromium plated, fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with Long screwed shanks and fly-nuts, screwed for Iron pipe and fixed-in-repairs complete all as specified and directed. |
| 52 | S&F for stop valve 15mm bore (dia), cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butter-fly handle, screwed both ends for Iron pipe or for unions and fixed-in-repairs complete all as specified and directed. |
| 53 | S&F for stop valve 15mm bore (dia), cast copper alloy, chromium plated, fancy type with long shank and cup (concealed type), screwed down, high pressure, with crutch or butter-fly handle, screwed both ends for iron pipe or for unions and fixed-in-repairs complete all as specified and directed. |
| 54 | S&F for 20mm bore (dia) gun metal globe/ gate valve with iron wheel head, screwed both ends for iron pipe and fixed-in-repairs complete all as specified and directed. |
| 55 | S&F for PTMT ball valve 20mm bore (dia), having weight not less than 210 grams, high pressure with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe complete all as specified and directed. |
| 56 | M&L for vitreous china white squatting pan of size 580x440mm, orissa pattern with integral foot rests, ‘P’ or ‘S’ trap, providing Joints between flush pipe and socket of WC pan, cones, India rubber (nozzles of WC pan) including cement concrete 1:5:10 (40mm graded stone aggregates) in bedding and making good to floor/ disturbed surfaces and fixed-in-repairs complete all as specified and directed. |
| 57 | S&F for PVC flushing cistern 10 litre capacity white, low level, valveless, syphonic action type, ISI marked with Inlet, ball valve, float and handle, a pair of cast iron brackets erecting stand duly painted, including PVC flush pipe 32mm or 40mm bore (dia) of low or high density with PVC long bend, cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3 and fixed-in-repairs complete all as specified and directed. |
| 58 | S&F for vitreous china white wash hand basin 550x400mm, flat back or angle back type with brass chromium plated waste fitting 32mm bore (dia) and PVC waste pipe 32mm or 40mm bore (dia) of low or high density, a pair of cast Iron brackets or erecting stand duly painted, cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3 but excluding taps, chain, plug & porcelain stopper and fixed-in-repairs complete all as specified and directed. |
| 59 | S&F for PVC connection pipe 15mm in size and 450mm in Length with PTMT nuts and fixed-in-repairs complete all as specified and directed. |
| 60 | S&F for looking mirror size 600x450mm, 5.5mm thick selected quality glass, bevelled edge, mounted on 4.0mm thick PVC Sheet with PVC/ PTMT frame, fixed to Wooden plug with brass chromium plated screws and fixed-in-repairs complete all as specified and directed. |
| 61 | S&F for chromium plated shower rose 125mm size with shower arm, swivel joint including fixing to steel/ CPVC pipe and fixed-in-repairs complete all as specified and directed. |
| 62 | S&F for tubular towel rail 20mm dia, brass chromium plated, D-type, 600mm long between flanges with bracket (one pair) and fixed-in-repairs complete all as specified and directed. |
| 63 | S&F in repair 75mm bore (dia) PVC (SWR) floor trap with chromium plated grating, plain including jointing to waste pipe with solvent cement and fixed-in-repairs complete all as specified and directed. |
| 64 | S&F in repair 100mm dia (Minimum weight 25 Grams) PTMT grating doom complete all as specified and directed. |
| 65 | S&F in repair 110mm bore (dia) PVC (SWR) Pipe, single socketed, in any length with rubber ring joints, fixing to walls or laid on floors with clamps complete all as specified and directed. |
| 66 | S&F in repar 75mm bore (dia) PVC (SWR) bends (any radius) and jointing with solvent cement complete all as specified and directed. |
| 67 | S&F in repar 75mm bore (dia) PVC (SWR) junction, single (Single T), equal or unequal with access door and jointing with solvent cement complete all as specified and directed. |
| 68 | S&F in repar 75mm bore (dia) PVC (SWR) pipe, single socketed, in any length with rubber ring joints, fixing to walls or laid on floors with clamps complete all as specified and directed. |
| 69 | S&F in repair 110mm bore (dia) PVC (SWR) bends (any radius) and jointing with solvent cement complete all as specified and directed. |
| 70 | S&F in repair 110mm bore (dia) PVC (SWR) junction, single (single T), equal or unequal with access door and jointing with solvent cement complete all as specified and directed. |
| 71 | Dismantling of water tank and removing to store complete all as specified and directed. |
| 72 | S&F 500 Litres Rotational moulded polyethylene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part 1 |
| 73 | Taking down existing unserviceable roof treatment of any description including cement plaster any thickness from roof surface, cleaning of roof surface and preparing it for further treatment and removing the debries/ rubbiesh material from site complete all as specified and directed. |
| 74 | M&L for rendering 15mm thick plaster on concrete surfaces or on fair faces of brick work in cement mortar 1:4 finished even and smooth with out using extra cement complete all as specified and directed. |
| 75 | Demolition of brickwork or stone/ boulder masonary, built in cement mortar complete all as specified and directed. |
| 76 | M&L for brick work built in cement mortar 1:6 straight or curved on plan exceeding 6 mtr mean radius using sub class 'B' bricks (Old size bricks) complete all as specified and directed. |
| 77 | M&L for 75 mm thk PCC 1:3:6 type C-2 (40 mm graded stone aggregate) finishing as even and smooth without using extra cement complete all as specified and directed. |
| 78 | Demolition of reinforcement cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 79 | M&L for reinforced cement concrete type B1 1:2:4 20 mm graded stone aggregate complete all as specified and directed. |
| 80 | M&L for hardcore broken stone or boulders, gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface complete all as specified and directed. |
| 81 | M&L for cement concrete type B -2 1:2:4 (40 mm graded stone aggregates) 100 mm thk in sub-base to flooring, finished concrete surfaces even and rough to receive floor finishes complete all as specified and directed. |
| 82 | M&L for cement concrete 1:2:4 (20 mm graded stone aggregates) in lintels upto 1.50 mtr clear span, cills, steps; Seismic and other similar bands, plinth courses, String courses, parapets and railings upto 600 mm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering. Slightly rounded or chamfered angles and throating, finishing all exposed faces of concrete including use and waste of formworkas required / ordered complete all as specified and directed. |
| 83 | M&L for Sand filling and/ or sand cushioning average 50mm thick under floor or interlocking paver blocks etc including watering (if required) and consolidation complete all as specified and directed. |
| 84 | M&L for machine pressed Pre-cast concrete interlocking paver block 60mm thick of M-35 Grade, with grey cement and pigment of any shape and size (as ordered), conforming IS-15658-2006 complete all as specified and directed. |
| 85 | Demolition of cement concrete (unreinforced) in ground floor and pavings n.xc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 86 | Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and directed. |
| 87 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete complete all as specified and directed. |
| 88 | M&L for providing PCC 1:3:6 tupe C-1(using 20 mm aggregate), in (cement mortar 1:4 )lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates complete all as specified and directed. |
| 89 | Providing precast cement concrete 1:2:4 (20 mm graded stone aggrigate) in (cement mortar 1:4 ) window or door cills, lintels, bressumers, steps,quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps,columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling) corbels, brackets, etc. (of any section indicated), with plain fair faces,including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified and directed. |
| 90 | M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar (1:4) using old size bricks complete as in manholes, etc complete all as specified and directed. |
| 91 | M&L for mild steel work in frame work such as grills, grantings etc with ends of bars shouldered and / or reviled, framed guard bars, barred iron doors ladders walk ways, raillings, frame work of water tanks and similar articles complete all as specified and directed. |
| 92 | Dismantling of galvanised iron 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining complete all as specified and directed. |
| 93 | S&F for Galvanised iron 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and strainin and fixing to any type of stranded rails straining bolts including securing or tying at crossing with and provision of galvanised MS wire, staples or steel pins all including complete all as specified and directed. |
| 94 | S&F for concertina coil made with razor barbed tape of 600 mm dia fixed with clips etc all including dismantling of old coil complete all as specified and directed. |
| 95 | M&L for 15mm thick rendering in cement mortar (1:4) finishing the surfaces with fair and even without using extra cement complete all as specified and directed. |
| 96 | M&L for preparation of old plastered or unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coats exterior emulsion paint 100% acrylic, in camouflage pattern over one coat of primer, any tinted, including washing floors, cleaning glass, joinery,electrical fittings, wiring etc of drops and splashes complete all as specified and directed. |
| 97 | M&L for preparation of newly plastered surfaces of walls and applying exterier emulsion two coats, in camouflage pattern, any tinted over a coat of suitable primer including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and directed. |
| 98 | Excavation in trenches n.exc 1.5m deep and nexc 1.5m wide in soft/ loose soil for foundations etc and getting out complete all as specified and directed. |
| 99 | M&L cement concrete in Type C2 1:3:6 (40 mm graded stone aggregate) foundations, filling and mass concrete complete all as specified and directed. |
| 100 | Returning filling in incl spreading, levelling watering and well ramming in layers nexc 25cm in soft/ disintegrated rock complete all as specified and directed. |
| 101 | Removing excavated material exc 250m and nexc 500m and depositing where directed in soft disintegrated rocks complete all as specified and directed. |
| 102 | Taking down carefully copper/aluminum point wiring (light ,fan and power socket etc) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, calling bells etc removing materials for taking credit and making good matching to the existing colour to the disturbed surface wall/ floors etc complete all as specified and directed. |
| 103 | Taking down the existing unservicable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 104 | Taking down carefully ceiling/exhaust fans, sealing cable ends,dismantelling blades removing fan and blades for taking to store and refixing back to its original position and making good matching to the existing colour to the disturbed surface wall/ floors etc complete all as specified and directed. |
| 105 | M&L for point wiring with 1.5 sqmm cable PVC insulated, unsheathed type, copper conductor, multistranded cable (FRLSH Type), 1100 Volts grade (red colour cable for phase and black colour cable for neutral) including 1.5 sqmm copper conductor, multistranded cable (FRLS type) 1100 volts grade unsheathed PVC insulated (green colour cable for earth wire) continuity earth wire connected to common earth dolly to be drawn in and including PVC conduit, medium grade of suitable size including all fittings such as bend, elbow, tee, joint, junction box including cutting chases for concealed conduits/ sunken boxes and making good to disturbed walls,floors with sunk cast pressed steel terminal box made out of MS sheet for mounting of switch, socket, fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and directed for following:- |
| 106 | Light point controlled by one number one way switch |
| 107 | Fan point controlled by one number one way switch |
| 108 | 5 Amp s socket point on same board |
| 109 | 5 Amp switch socket point on independent board |
| 110 | Light point controlled by one two way switch complete |
| 111 | M&L for concealed point wiring PVC insulated and unsheathed cable with 2.5 Sqmm FLRSH copper conductor single core multi strand 1100 Volt drawn through medium grade PVC Conduit of suitable size and concealed/ surface metal box including 2.5 Sqmm earth wire copper insulated wire connected to common earth dolly complete for one 15 A switch socket combination on independent board complete all as specified and directed. |
| 112 | S&F for switch 1 way 6 Amps,230 volts, 50 HZ complete all as specified and directed. |
| 113 | S&F for switch 2 way 6 Amps,230 volts, 50 HZ complete all as specified and directed. |
| 114 | S&F for socket outlet 5 Amps,3 pin flush type, 230 volts, 50 HZ complete all as specified and directed. |
| 115 | S&F for switch socket combination 2 in1 3pin 5/15 A 240 Volts flush type multi purpose complete all as specified and directed. |
| 116 | S&F for switch socket combination 2 in1 3pin 5 A 240 Volts flush type multi purpose complete all as specified and directed. |
| 117 | S&F for ceiling rose surface type Bakelite 3 terminals complete all as specified and directed. |
| 118 | S&F for stepped type electronic type fan step regulator 240 Volt 120 W complete all as specified and directed. |
| 119 | S&F for lamp holder, PVC/ Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed. |
| 120 | M&L for LED bulb (B-22) of 1 x 9 w fitting properly in Lamp holder complete all as specified and directed. |
| 121 | S&F for inverter type batten LED light fitting of capacity 1X 20 W (or nearest next higher wattage) (4feet), 6500K, wall/ surface mounted,square profile housing and polycarbonate channel including lithium lon battery with charging time 8 hours and back up time up to 4 hours decorative type with integrated high efficiency electronic driver and operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and directed. Make : Havells, Model : Pride Plus inverter batten 20W 6500 K V1 (Cat Part No LHEXASP7IN1W020). |
| 122 | S&F for IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with PC housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more,operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete with all accessories internally prewired and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified and directed. Make : Crompton, Model : Trim Linea neu (Cat Part No TCS-109-10-65-SL-DP-NWH) & make : Havells, Model : LUMILINE NXT BATTEN (Cat Part No : LUMILINENXTBS10WLED840SPCWH). |
| 123 | S&F in repair of bulk head luminaire environmental friendly, ultra modern,energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs 10 watt, 230 volts, 50 Hz including lamp, connection wirecomplete all as specified and directed. Make : Crompton, Model : RI GEL (Cat Part No TIS-303-10-57-SL-DP-NWH) |
| 124 | S&F for sheet metal enclosure MCB DB SPN double door type AC 240 V 8 way with 200 Amps rated bus bar, vertical/ horizantal type including taking down old one complete and making good of distructed surface complete all as specified and directed. |
| 125 | S&F for MCB SPN 32 Amps, 230 volts,C curve complete all as specified and directed. |
| 126 | S&F for MCB SP 10 to 32 Amps, 230 volts, C curve complete all as specified and directed. |
| 127 | Excavation in trenches n.exc 1.50 mtr wide and n.exc 1.50 mtr deep for taking out/ laying of under ground cable, pole, pipe, stay and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed. |
| 128 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and directed. |
| 129 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as specified and directed. Note: Punned thickness of sand shall be measured & paid. |
| 130 | M&L for well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified and directed. |
| 131 | M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing upto 50 mm bore complete all as specified and directed. |
| 132 | S&F in replacement GI protection pipe of 40 mm dia light grade for cable protection including all fittings laid in trenches or fixed on pole/ walls with mild steel clamps, bolts, nuts and washers complete all as specified and directed.Note:- Earth work shall be measured and paid separately. |
| 133 | Taking out old serviceable/ unserviceable cable of size 10 Sqmm, 2 core of any make/ type for requisite replacement/ further disposal complete including taking out bricks complete all as specified and directed.Note: Earth work shall be measured & paid separately. |
| 134 | Supply, fixing, laying connecting and commissioning LT underground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable with multistranded aluminium conductor,10 sqmm,2.0 core, 1100 Volts grade laid in trenches/ on wall/ poles/ ducts/ pipe including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and directed.Note: Earth work shall be measured & paid separately. |
| 135 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6.3mm thick elecrode and 4mm galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 20mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. Material and labour laying well burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender