Tender For Repair/Maint Of Fire Pump, Fire Distribution, Fire Tank, Fire Alarm Under Ge Dehu Road
Tender Value
54 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
15 days left
EMD
1.06 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Fire Pump, Fire Distribution, Fire Tank, Fire Alarm Under Ge Dehu Road
BOQ
| Sl. No. | Item Description |
| 1 | Taking down the unserviceable fire pipe and supply and lay M S ERW Pipes heavy grade with all fittings laid in ground, floors or fixed to walls and ceilings etc of sizes 100 MM all as directed. |
| 2 | Taking down the unserviceable fire pipe and supply and fixing Butterfly Valve 100 mm all as directed. |
| 3 | Taking down the unserviceable fire pipe and supply and fixing of fire hydrant landing single headed valve 63 mm dia CI body GM parts heavy duty with necessary arrangement suitable for fixing 80 mm Fire pipe all as specified and directed. |
| 4 | Taking down the unserviceable fire pipe and supply and fixing hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard all as specified and directed. |
| 5 | Taking down the unserviceable fire pipe and supply and fixing RRL hose type 30 meter length one both end male female socket made with gunmetal suitable for 63mm hydrant valve all as specified and directed. |
| 6 | Taking down the unserviceable fire pipe and supply and fixing Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short all as specified and directed. |
| 7 | Maintenance fire fighting Diesel Engine operated pump of capacity 150 BHP through authorise service agency at Location: KINAHI Pump House 1 Nos) Note:- Spares required for above maint will be measured and paid separately under relevant items . Scope Of Work :- (a) Engine Cooling System :-Checking of radiator conditions (check for radiator clogging, cooling fins condition, V belts, etc. Checking of K-Cool Super level, piping corrosions & any sign of radiator leaks. Checking of hoses & connections deterioration / wear & tear. Checking of hoses & connections deterioration / wear & tear. Checking of fan pulley mis-alignment / deterioration, defective bearings, corroded surface, grease condition. Checking the water pump leaks, noisy operation, abnormal vibration, impeller defects, cracked housing, worn out shaft, etc Checking of belts tension & deterioration. Checking thermostat for proper functioning. Checking water level sensor in radiator for K-Series Engines . |
| 8 | (b) Engine Fuel System :-Checking fuel lines connections (any signs of fuel leak, loose connections, corroded piping, fuel restrictions, defective clamps, deteriorated hose, etc.).Checking governors & controls conditions (any sign of deterioration, loose connections & system malfunction/ not responding etc.).Checking governors & controls conditions (any sign of deterioration, loose connections & system malfunction/ not responding etc.) Checking actuator of electronic governing system. Checking priming pump condition. Checking fuel filter condition – replace the filters as found necessary. Checking water separator condition. Checking fuel tank condition (any sign of water contamination, no water drain, corrosions / deteriorations, etc. Checking exhaust smoke condition to identify health of the engine. (c) Engine Lubricating System Inspection :-Checking oil lines connections (any signs of oil leak, loose connections, corroded piping, defective clamps, deteriorated hose, etc. Checking oil pressure condition (any sign of erratic operation, defective gauges, defective pressure sensors, defective wiring harness, etc. Checking oil level & oil quality condition. Checking last oil change & oil filter replacement. Checking make up oil availability at site. |
| 9 | (d) Engine Air Induction System :-Checking air filter indicator reading (any sign of defective sensor, erratic operation).Checking air filter (any sign of filter clogging, dirt accumulation, air obstruction, defective seal, damage/ deteriorated housing etc. Checking turbocharger condition (any sign of excessive end play, oil/ gas leak, abnormal operating noise, excessive vibration, overheating etc.)Checking hoses & connections deterioration / wear & tear. Checking Charge Air cooler condition- if any (sign of clogged core/ fins, air leaks at connections, damaged gaskets, etc. (e) Engine Exhaust System :-Checking the exhaust manifold condition (any sign of gas leak, missing bolts and nuts, red hot manifold, oil leak, deterioration etc. Checking the flexible bellow/ hoses & connections deterioration / wear & tear. Checking muffler condition (any sign of support insufficiency, corrosion, drain pipe valve not installed, not shielded, etc).Checking exhaust pipe insulation condition / deterioration. Checking smoke emission quality (any sign of excessive black smoke, bluish smoke, white smoke, restricted gas flow etc. (f) Engine Electrical System :-Checking batteries condition (electrolyte level, distilled water level, defective plate, voltage drop during cranking-refer to manufacturer acceptable voltage drop, etc..), Battery capacity evaluation this can be done by battery discharge test. Replacement of batteries is to be planned. Checking the starting motor condition (any sign of defective solenoid, defective brushes, grounded / shorted connection, struck up rotor etc. Checking the wiring harness condition (any sign of defects, grounded, loose connections, shorted, open circuit, any deterioration. |
| 10 | (g) Generator Control Panel System Inspection :- Checking “start / stop / manual switch condition & functionality. Checking “voltmeter”, “Ammeter”, “frequency “ meter for proper functionality. Checking “voltmeter”, “Ammeter”, “frequency “ meter for proper functionality. Checking “Contactors, ACB for proper functioning /operations. Checking “wiring termination for proper tightness. Checking indicating lamps for proper functioning. Checking if fault/tripping circuits are working satisfactory. Checking if doors are closing properly. Checking if there is no blockage of air from rear ducts. Checking if the front opening is directing the hot air outside room. |
| 11 | All as per above item before but fire fighting Disel Engine operated pump of capacity 133 BHP Panel through authorise service agency of OEM ,Make- Kirloskar Location: 29 FAD |
| 12 | All as per above item before but fire fighting Disel Engine operated pump of capacity of 47 BHP Panel through authorise service agency of OEM ,Make- Kirloskar. Location: 29 FAD |
| 13 | Taking down the unserviceable items and supply and fixing the Lub Oil filter for 150/133/47BHP Diesel Engine pump |
| 14 | Taking down the unserviceable items and supply and fixing the Fan V-belt for 150/133/47BHP Diesel Engine pump |
| 15 | Supply and filling Coolant for radiators |
| 16 | Taking down the unserviceable engine oil and Supply and filling in replacement/topping up engine oil multi grade 15w to 40W in engine all as specified and directed. |
| 17 | M&L for repair the fire engine 150BHP Make:- Kirloskar with the following details (a) Check cylinder head for valve leakage/grinding, polishing the same. (b) Decarbonisation of combustion chamber, piston ring grooves. (c ) S/F the piston ring complete =01set. (d) S/F Piston pin =1 set (e) S/F Cylinder head bolt =1 set (f) S/F Cylinder liner=1 set (g) S/F Inlet valve seat =1 set (h) S/F Exhaust valve seat = 1Set (j) S/F Valve guide =1 set (k) S/F all joints, gaskets & O rings=01set. (l) S&F thermostat =01no (m) Cleaning the cooling system, stainer, diesel tank, engine sump=01job. (n) S&F water pump =01no. (o) S&F Coolant Hose-1set (p) S&F fuel ratio control-01no(q) Reassemble all parts and testing complete all as directed. |
| 18 | M&L for repair the fire engine 130BHP Make:- Kirloskar with the following details (a) Check cylinder head for valve leakage/grinding ,polishing the same. (b) Decarbonisation of combustion chamber, piston ring grooves. (c) S/F the piston ring complete =01set. (d) S/F Piston pin =1 set (e) S/F Cylinder head bolt =1 set (f) S/F Cylinder liner=1 set (g) S/F Inlet valve seat =1 set (h) S/F Exhaust valve seat = 1Set (j) S/F Valve guide =1 set (k) S/F all joints, gaskets & O rings=01set. (l) S&F thermostat =01no (m) Cleaning the cooling system, stainer, diesel tank, engine sump=01job. (n) S&F water pump =01no. (o) S&F Coolant Hose-1set (p) S&F fuel ratio control-01no(q) Reassemble all parts and testing complete all as directed. |
| 19 | M&L for repair the fire engine 47 BHP Make:- Kirloskar with the following details (a) Check cylinder head for valve leakage/grinding ,polishing the same. (b) Decarbonisation of combustion chamber, piston ring grooves. (c )S/F the piston ring complete =01set. (d) S/F Piston pin =1 set (e) S/F Cylinder head bolt =1 set (f) S/F Cylinder liner=1 set (g) S/F Inlet valve seat =1 set (h) S/F Exhaust valve seat = 1Set (j) S/F Valve guide =1 set (k) S/F all joints, gaskets & O rings=01set. (l) S&F thermostat =01no (m) cleaning the cooling system, stainer, diesel tank, engine sump=01job. (n) S&F water pump =01no. (o) S&F Coolant Hose-1set (p) S&F fuel ratio control-01no(q) Reassemble all parts and testing complete all as directed. |
| 20 | M&L for cleaning thoroughly by using wire brush/coconut coir of walls and floor of Semi Under Ground Open Sump (SWT) of capacity 3.0 Lakh Ltr TO 4.5 Lakh ltr at COD Reservoir NO 1 and taking out all accumulated silt, foreign materials etc including disposal of materials n. exc. 50 mtr as directed and cleaning of chocked pipes etc by applying soda lime solutions with white primer one coat and writing Tank capacity by Paint all as directed. |
| 21 | M&L for cleaning thoroughly by using wire brush/coconut coir of walls and floor of Semi Under Ground Open Sump (SWT) of capacity 1.8 Lakh Ltr TO 3.0 Lakh ltr at COD Reservoir NO 2 and C2 Pump House and taking out all accumulated silt, foreign materials etc including disposal of materials n. exc. 50 mtr as directed and cleaning of chocked pipes etc by applying soda lime solutions with white primer one coat and writing Tank capacity by Paint all as directed. |
| 22 | M&L for cleaning thoroughly by using wire brush/coconut coir of walls and floor of Semi Under Ground Open Sump (SWT) of capacity 0.9 Lakh Ltr TO 1.8 Lakh ltr at COD and ODTD SWT and taking out all accumulated silt, foreign materials etc including disposal of materials n. exc. 50 mtr as directed and cleaning of chocked pipes etc by applying soda lime solutions with white primer one coat and writing Tank capacity by Paint all as directed. |
| 23 | M&L for cleaning thoroughly by using wire brush/coconut coir of walls and floor of Semi Under Ground Open Sump (SWT) of capacity 0.5 Lakh Ltr TO 0.9 Lakh ltr at COD and ODTD SWT and taking out all accumulated silt, foreign materials etc including disposal of materials n. exc. 50 mtr as directed and cleaning of chocked pipes etc by applying soda lime solutions with white primer one coat and writing Tank capacity by Paint all as directed. Please Enable Macros to View BoQ information |
| 24 | M&L for cleaning thoroughly by using wire brush/coconut coir of walls and floor of Semi Under Ground Open Sump (SWT) of capacity 0.5 Lakh Ltr TO 0.9 Lakh ltr at COD and ODTD SWT and taking out all accumulated silt, foreign materials etc including disposal of materials n. exc. 50 mtr as directed and cleaning of chocked pipes etc by applying soda lime solutions with white primer one coat and writing Tank capacity by Paint all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysJul 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer