Tender For Repair/Maint Of Ci/Gi Water Pipeline And Allied Works Including Cleaning Of Ohts/Ug Sumps, Repair/Maintenance Of Pumps And Electric Motors And Repair/Maint Of Solar Water Heaters And Allied Works At Af Stnmandoreat Af Stn Mandore Under Age
Tender Overview
Project Description
Tender for Repair/Maint Of Ci/Gi Water Pipeline And Allied Works Including Cleaning Of Ohts/Ug Sumps, Repair/Maintenance Of Pumps And Electric Motors And Repair/Maint Of Solar Water Heaters And Allied Works At Af Stnmandoreat Af Stn Mandore Under Age E/M, Ge (Af) No 2 Jodhpur
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, pier holes, for foundations of poles, struts, stays etc. or laying underground cable and water supply pipe lines etc. in hard/dense soil/rocks, & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge. |
| 2 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge. |
| 3 | Removal of excavated soil material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge. |
| 4 | Taking up or down 15mm bore galvanised steel water tubing including connections, fixed in walls, ceiling or laid under floor or laid in trenches etc complete all as specified and directed by Engineer-in-charge. Note :-Excavation and earthwork shall be measured and paid for separately |
| 5 | All as per Srl item No 4 above but 20 mm dia bore. |
| 6 | All as per Srl item No 4 above but 25 mm dia bore. |
| 7 | All as per Srl item No 4 above but 40 mm dia bore. |
| 8 | All as per Srl item No 4 above but 50 mm dia bore. |
| 9 | Taking up or down 80 mm bore CI/DI/GI water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead, laid under floor or laid in trenches etc complete all as specified and directed by Engineer-in-charge. Note :-Excavation and earthwork shall be measured and paid for separately. |
| 10 | All as per Srl item No 09 above but 100 mm dia bore. |
| 11 | S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge. |
| 12 | All as per Srl item No 11 above but 20 mm dia bore. |
| 13 | All as per Srl item No 11 above but 20 mm dia bore. |
| 14 | All as per Srl item No 11 above but 20 mm dia bore. |
| 15 | All as per Srl item No 11 above but 25 mm dia bore. |
| 16 | All as per Srl item No 11 above but 40 mm dia bore. |
| 17 | Supplying, laying, jointing, commissioning and testing 100mm bore centrifugally cast (Spun) ductile iron pressure pipe with spigot and socketed ends class K-7, confirming to IS : 8329/2000 blast furnace slag cement with portland cement properties suitable for rubber gasket jointing / tyton joints with inside cement mortar lining and black bitumen external coating, duly (ISI marked) laid in trenches complete all as specified and directed by Engineer-in-Charge. Note :- (i) DI fittings shall be measured and paid separately under respective items (ii) Pipes shall be laid in trenches already excavated for taking out old GI pipe line. Extra excavation / earthwork shall not be paid. |
| 18 | S & F as in repairs hot water steel water tubing, 15 mm bore,medium grade, galvanised,with all fittings such as bends,tee,short piece, connectors,back nuts, diminishing pieces,caps ,plugs and union etc fixed complete to walls and ceilings or laid in floors including insulation with glass wool,wiremeshand aluminium cladding complete all as specified and directed |
| 19 | All as per Srl item No 18 above but 20 mm dia bore. |
| 20 | All as per Srl item No 18 above but 25 mm dia bore. |
| 21 | All as per Srl item No 18 above but 40 mm dia bore. |
| 22 | S&F in replacement gun metal globe or gate valve 15mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge. |
| 23 | All as per Srl item No 22 above but 20 mm dia bore. |
| 24 | All as per Srl item No 22 above but 25 mm dia bore. |
| 25 | All as per Srl item No 22 above but 40 mm dia bore. |
| 26 | All as per Srl item No 22 above but 50 mm dia bore. |
| 27 | Supplying, fixing and testing in replacement of 80mm bore cast iron sluice valve with flanged ends drilled ISI marked conforming Class PN 1.6 to IS 14846-2000 with stainless steel spindle with iron wheel, CI gate with brass nut, bolts, washers and rubber packing for connecting pieces etc complete all as specified and as directed by Engineer-in-Charge. |
| 28 | All as per Srl item No 27 above but 100 mm dia bore. |
| 29 | S&F Cast iron non return valve / reflux valve with rubber seat flanged type with by pass arrangement suitable for 80mm bore pipe, ISI marked, conforming to IS- 5312/2004 with stainless steel spindle, CI gate with brass nuts, bolts, washers and jointing with necessary ruber gasket etc complete all as specified and directed by Engineer-in-charge. |
| 30 | All as per Srl item No 29.00 above but 100 mm dia bore. |
| 31 | Supply and fix Foot Valve conforming to IS 4038, 80 mm (4”) dia complete all as specified and directed by Engineer-in-charge. |
| 32 | All as per Srl item No. 31.00 above but size of 100mm |
| 33 | S & F in repair 15mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed all as specified and directed. |
| 34 | All as per Srl item No 33 above but 20 mm dia bore. |
| 35 | All as per Srl item No 33 above but 25 mm dia bore. |
| 36 | Supplying & fixing DI fittings confirming to IS-9523-2000 suitable for spigot & socketed pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc),tee pieces, single branch, 'Y' junction, double branch, cross collar, caps and plugs etc. suitable for spigot and socketed pipes upto 150 mm bore, complete, all as specified and directed by Engineer-in-charge. |
| 37 | M&L for 'D' Joint suitable for DI /CI/GI pipe sizes 50 mm dia bore including excavation work and other fittings as required including testing at site complete all as specified and directed by the Engineer-in-Charge. |
| 38 | All as per Srl item No 37 above but 80 mm dia bore. |
| 39 | All as per Srl item No 37 above but 100 mm dia bore. |
| 40 | Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same all as specified and directed by Engr-in-Charge. |
| 41 | M&L for taking out of Elect Motor 20/30 HP Capacity installed as motor from foundation after disconnecting electrical connections, dismantling motor and rewiding the same with super enamelled copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts, reassembling and fixing the same in its original position including replacement of unserviceable nut-bolts, washer, lugs, terminal plate and making proper electrical connection complete all as specified and directed by Engineer-in-charge. Note : - (i) Bearing if required for replacement shall be paid seprately (ii) Transportation of motor is included in the unit rate of items nothing extra shall be paid on this account |
| 42 | All as per serial item No. 41 above but motor of capacity 10/12.5 HP |
| 43 | All as per serial item No. 41 above but motor of capacity 7.5 HP |
| 44 | Taking out centrifugal motor of any capacity from foundation, dismantling the motor, taking out rotor and filling the material by welding work, finishing by lathe machine, replacement of unserviceable bearing, reassembling the motor and fixed in its original position complete all as specified and directed by Engineer-in-charge. Note: - (i) Bearing shall be measured and paid for separately as “Supply only” (ii) New Nuts, bolts and washers if required for refixing the motor shall be provided by the contractor, nothing extra shall be paid on this account |
| 45 | Supply only Ball Bearing of suitable size for rotor of motor 20/30 HP installed complete all as specified and directed by Engineer-in-charge. |
| 46 | All as per serial item No 45 above but for motor of 10 /12.5 HP. |
| 47 | All as per serial item No 45 above but for motor of 7.5 HP. |
| 48 | Taking out defective centrifugal pump set , assembled with 20/30 HP elelctric motor, dismantling the pump set for carrying out repair / replacement of unserviceable parts such as CI impeller, Bush, ball bearing etc. reassembling, installing, commissioning and testing complete all as specified and directed by Engineer-in-charge. Note :(i) CI impeller, Bush & ball bearing required to replace shall be measured and paid for separately under respective items of BOQ as “Supply only” (ii) The cost of transportation is included in the unit rate of this item nothing extra shall be paid on this account. |
| 49 | All as per serial item No 49 above but pump set assembled with 10 /12.5 HP elelctric motor |
| 50 | All as per serial item No 49 above but pump set assembled with 7.5 HP elelctric motor |
| 51 | Supply only ball bearing suitable for centrifugal Pump set assembled with 20/30 HP motor complete all as specified and directed by Engineer-in-charge. |
| 52 | All as per serial item No 52 above but assembled with 10 /12.5 HP Motor |
| 53 | All as per serial item No 52 above but assembled with 7 .5 HP Motor |
| 54 | Supply only stainless steel Bush suitable for pump set assembled with 20/30 HP motor complete all as specified and directed by Engineer-in-charge. |
| 55 | All as per serial item No 56 above but assembled with 10 / 12.5 HP Motor |
| 56 | All as per serial item No 56 above but assembled with 7.5 HP Motor |
| 57 | Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 16 Sqmm 3 core complete all as specified & as directed by Engineer –in-charge. |
| 58 | All as per serial item No.58 above but 10 Sqmm 3 core. |
| 59 | All as per serial item No.58 above but 6 Sqmm 3 core. |
| 60 | All as per serial item No.58 above but 4 Sqmm 3 core. |
| 61 | S&F in replacement rubber coupling as per existing model & make suitable for centrifugal pump set assembled with 20/30 HP motor complete all as specified & as directed by Engineer –in-charge. |
| 62 | All as per serial item No. 61 here-in-above but assembled with 10/7.5 HP motor |
| 63 | S&F in replacement cooling fan with locking aluminum cast type screw, as per existing type, suitable for 30/20/ HP motor complete all as specified & as directed by Engineer –in-charge. |
| 64 | All as per serial item No. 63 above but suitable for 10 / 7.5 HP motor |
| 65 | S&F gland rope of size 10 sqmm or as required complete all as specified & as directed by Engineer –in-charge |
| 66 | S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge |
| 67 | S&F in replacement Digital type Ammeter 96mm x 96 mm, single phase, as suitable range, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge |
| 68 | S&F in replacement contactor ML-2, 3 phase 415 volts having auxiliary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 40 Amps and AC1 Rating 45 Amps complete all as specified and as directed by Engineer –in-charge. |
| 69 | S&F in replacement contactor ML-3, 3 phase 415 volts having auxiliary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 40 Amps and AC1 Rating 45 Amps complete all as specified and as directed by Engineer –in-charge. |
| 70 | S&F in replacement overload relay, suitable for 7.5 HP to 30 HP motor, 3 phase, 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge. |
| 71 | S&F in replacement single phase preventer type SDz5, SPPR + Timer, 415 V including necessary copper connection, lugs etc complete all as specified & as directed by Engineer-in-charge |
| 72 | S&F in replacement electronic timer type ET100, 110 / 240V, 50 HZ including necessary electric connection complete all as specified & as directed by Engineer-in-charge . |
| 73 | S&F in replacement MCCB 4 Pole 100 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt and connections complete all as specified and as directed by Engineer-in-Charge. |
| 74 | S&F in replacement MCCB 4 Pole 63 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt and connections complete all as specified and as directed by Engineer-in-Charge. |
| 75 | M & L for cleaning of RCC underground sump of capacity 50000 Gallons at AF Stn Mandore , dewatering the sump with water lifting pump , de-scaling internal surfaces of underground sumps with wire brush , removing the deposited mud from inside the sump , washing with bleaching powder & flush water two times and dewatering, applying two coats of lime wash inside the sump including writing capacity of tank , date of cleaning with synthetic enamel paint of white tint over black base (size of letter 5 mm thick and 15 cm in height) complete all as specified and as directed. |
| 76 | M & L for cleaning of RCC underground sump of capacity 50000 Gallons at Balsamand site AF Stn Mandore , dewatering the sump with water lifting pump , de-scaling internal surfaces of underground sumps with wire brush , removing the deposited mud from inside the sump , washing with bleaching powder & flush water two times and dewatering, applying two coats of lime wash inside the sump including writing capacity of tank , date of cleaning with synthetic enamel paint of white tint over black base (size of letter 5 mm thick and 15 cm in height) complete all as specified and as directed. |
| 77 | M & L for cleaning of RCC OHT capacity 50000 Gallons at AF Stn Mandore by descaling internal surfaces of OHT with wire brush , removing the deposited mud from inside tank , washing with bleaching powder & flush water two times and dewatering including writing capacity of tank , date of cleaning with synthetic enamel paint of tint white over black case (size of letter 10mm thick and 20 cm in height) complete all as specified and as directed |
| 78 | Cleaning of SWT pumping out complete/flushing out dirty water mud sludge dirt etc from inside the SWT by mud pump/bucket (Manually), cleaning in side walls, top & bottom surface of the SWT scraping, with wire brush, removing mud and sludge etc from tank to a distance upto 50 mtrs and depositing all as directed by Engr-in-Charge at site washing the SWT/pipes with bleaching powder solution and finally applying cement coat with 2% of potassium permanganate solution for disinfection all as directed by Engr-in-Charge including making with black paint of static water tank cleaned on dt of following capacity/depth :- |
| 79 | SWT of capacity 50000 Ltrs at Near OHT AF station Mandore. |
| 80 | SWT of capacity 50000 Ltrs at Near MT section bldg AF station Mandore. |
| 81 | SWT of capacity 50000 Ltrs at Near Arnoc Bldg bldg AF station Mandore. |
| 82 | Supply only Water treatment Calcium hypo Chloride 65%-70% chlorine content (calcium based granular disinfectant for water treatment, packed in 45 kg drum complete. |
| 83 | Supply only Water treatmentbleaching Powder 25 Kg bag complete all as specified and as directed. |
| 84 | Comprehensive maintenance servicing and testing of RO plant of 1000 Ltrs/hr capacity including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set & dosing unit for supply qualitative water at permissible level of TDS as and when directed by Engr-in- charge. |
| 85 | Supply only sediment filter/pre filter Jambo 2011 as per existing make and model for 1000 ltrs RO Plant. |
| 86 | S&F RO Membrane for 1000 ltrs RO Plant complete all as specified and as directed. |
| 87 | M & L Carbon media for 1000 ltrs RO plant. |
| 88 | M & L Resin media for 1000 ltrs RO plant . |
| 89 | M & L Sand suitable for RO plant. |
| 90 | Comprehensive maintenance servicing and testing of water purifier AG 600 DF including washing, cleaning of filter, disinfection process complete all as specified and directed by Engr-in- charge. |
| 91 | M & L pre filter candle 204 as per existing make and model for water purifier complete all as specified and as directed. |
| 92 | Supply and fix pressure gauge air water meter of pressure range 0-10 kg/sqcm complete all as specified and as directed. |
| 93 | Supply, laying, jointing and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 10 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc. including taking out old unserviceable cable complete all as specified. |
| 94 | S&F as in Rotational moulded polyethylene water storage tanks cap 1000 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified |
| 95 | .S&F as in Rotational moulded polyethylene water storage tanks cap 2000 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified. |
| 96 | Supplying & laying in trencies Polyethylene (PE-AL-PE) 15mm dia bore compositc pressure pipes includin all Crimp type internal sealing Plastic-Metal Composite fittings (such as elbows, tees, reducers, |
| 97 | All as per Srl item No 94 above but 25 mm dia bore. |
| 98 | All as per Srl item No 94 above but 40 mm dia bore. |
| 99 | S&F sheet metal enclosure comprising with socket plug ,Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amp complete all as specified and as directed. |
| 100 | S&F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amp all as specified and as directed. |
| 101 | S&F in replacement of stainless steel tank of 1000 LPD capacity solar water heater as per existing size and shape complete all as specified and as directed |
| 102 | S&F in replacement of stainless steel tank of 2000 LPD capacity solar water heater as per existing size and shape complete all as specified and as directed |
| 103 | M&L servicing and maintenance of complete solar water heater plant of capacity 1000 LPD installed at single/double story buildings including carrying out repair to minor leakage, brazing work ,cleaning of flat plate collector glass & cleaning of HDPE water tank and make up tank including dismantling inlet and outlet connections and refixing the same after cleaning for proper functioning to maintain proper water temperature complete all as specified & as directed. |
| 104 | M&L servicing and maintenance of complete solar water heater plant of capacity 2000 LPD installed at single/double story buildings including carrying out repair to minor leakage, cleaning of flat plate collector glass & cleaning of HDPE water tank and make up tank including dismantling inlet and outlet connections and refixing the same after cleaning for proper functioning to maintain proper water temperature complete all as specified & as directed. |
| 105 | M&L disconnecting of hot water, cold water system complete and removing leakage of hot water tank by welding to tank and refixing the same complete in all respect and testing for solar water heater of capacity1000,2000 LPD complete all as specified and as directed |
| 106 | Supply only Solar Flat Plate Collector (existing size) having made of copper absorber having 2 Sqm area including connected items as required at site to make it fully funtioning complete all as specified and as directed by Engineer-in-charge. |
| 107 | Supply only gasket set for solar water heater panel suitable for 1000/2000 LPD capacity as per existing sample, including other connected items as required at site to make it fully funtioning complete all as specified and as directed by Engineer-in-charge. |
| 108 | S&F in replacement non return valve 20 mm bore for iron pipes complete all as specified and directed by Engineer-in-charge. |
| 109 | M&L rubber hose pipe 20mm dia between hot water tank & collector including dismantling & taking out existing unserviceable rubber hose pipe complete all as specified and as directed. |
| 110 | S & F in repair heating element of capacity 3KW as per existing type including rubber washer , bolts clamps etc. for any type of solar water heater complete all as specifie and as directed by Engineer-in-charge |
| 111 | S & F in repair heating element of capacity 2KW as per existing type including rubber washer , bolts clamps etc. for any type of solar water heater complete all as specifie and as directed by Engineer-in-charge |
| 112 | Supply and fixing in replacement of thermostatic switch (ISI marked) of range 0˚C to 80˚C suitable for solar water heater as per existing sample . |
| 113 | S&F in replacement fully automatic star delta starter type ML2 FASD having relay of range 20 - 32 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge |
| 114 | S&F in replacement fully automatic star delta starter type for 10 HP having relay of range 08 - 12 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender