Project Description
Tender for special Repair/ Replacement Of Old Unsv Ward Lights At B&C Block At Ahrr Under Ge E/M R&R Hosp. Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | S & F in replacement of ceiling recessed mounting LED luminaire of size 600 mm x 600 mm (2’ x 2’), 36 Watt, suitable for Armstrong / grid ceiling, complete as required; the luminaire shall be made of CRCA sheet steel housing, powder coated for durability, and provided with opal / frosted polycarbonate (PC)/polystyrene (PS) diffuser for uniform glare-free illumination suitable for office applications; the LEDs used shall have luminous efficacy ≥120 lumen/watt, CCT 6500K (cool daylight), CRI ≥80, colour consistency SDCM ≤5, power factor ≥0.95, and surge protection minimum 3.5 kV, operating on input voltage range 180–270 V AC, 50 Hz; the luminaire shall be complete with high-efficiency constant current LED driver, and both luminaire and driver shall be BIS registered and of the same make/manufacturer; the brand name shall be permanently embossed/engraved on luminaire body/accessories/end caps and not applied by sticker or screen printing; complete with all fixing accessories, connections, etc., and installed as per site requirement and as directed by the Engineer-in-Charge. |
| 2 | S & F in replacement of ceiling recessed mounting LED luminaire of size 600 mm x 600 mm (2’ x 2’), 40/42 Watt, suitable for Armstrong / grid ceiling, complete as required; the luminaire shall be made of CRCA sheet steel housing, powder coated for durability, and provided with opal / frosted polycarbonate (PC)/polystyrene (PS) diffuser for uniform glare-free illumination suitable for office applications; the LEDs used shall have luminous efficacy ≥120 lumen/watt, CCT 6500K (cool daylight), CRI ≥80, colour consistency SDCM ≤5, power factor ≥0.95, and surge protection minimum 3.5 kV, operating on input voltage range 180–270 V AC, 50 Hz; the luminaire shall be complete with high-efficiency constant current LED driver, and both luminaire and driver shall be BIS registered and of the same make/manufacturer; the brand name shall be permanently embossed/engraved on luminaire body/accessories/end caps and not applied by sticker or screen printing; complete with all fixing accessories, connections, etc., and installed as per site requirement and as directed by the Engineer-in-Charge. |
| 3 | S & F in replacement of ceiling recessed mounting LED luminaire of size 600 mm x 600 mm (2’ x 2’), 36 Watt, suitable for Armstrong / grid ceiling, complete as required; the luminaire shall be provided with AN INBUILT MICROWAVE MOTION SENSOR CAPABLE OF AUTOMATIC OPERATION SUCH THAT THE LUMINAIRE GLOWS AT FULL BRIGHTNESS WHEN MOTION IS DETECTED AND DIMS TO A PRESET LOWER LEVEL IN THE ABSENCE OF MOVEMENT, with adjustable time delay/sensitivity as required; the luminaire shall be made of CRCA sheet steel housing, powder coated for durability, and provided with a fully diffused high-quality polycarbonate (PC)/polystyrene (PS) diffuser for uniform glare-free illumination suitable for office/passage areas; the LEDs used shall have luminous efficacy ≥120 lumen/watt, CCT 6500K, CRI ≥80, colour consistency SDCM ≤5, power factor ≥0.95, and surge protection minimum 3.5 kV, operating on input voltage range 140–270 V AC, 50 Hz; the luminaire shall be complete with a high-efficiency constant current LED driver, and both luminaire and driver shall be BIS registered and of the same make/manufacturer; the brand name shall be permanently embossed/engraved on the luminaire body/accessories/end caps and not applied by sticker or screen printing; complete with all fixing accessories, connections, and commissioning, as per site requirement and as directed by the Engineer-in-Charge. |
| 4 | S & F in replacement of ceiling recessed mounting LED Sky Light luminaire with printed customised design (design as approved by GE) of size 600 mm x 600 mm (2’ x 2’), 36 Watt, suitable for Armstrong/grid ceiling, complete as required; the luminaire shall be made of CRCA sheet steel housing, powder coated for durability, and provided with PC diffuser with customised printed design for uniform and aesthetic illumination; the LEDs used shall have CCT 6500K (neutral white), CRI ≥80, colour consistency SDCM ≤5, power factor ≥0.95, and surge protection minimum 3.5 kV, operating on input voltage range 180–270 V AC, 50 Hz; the luminaire shall be complete with high-efficiency constant current LED driver, and both luminaire and driver shall be BIS registered and of the same make/manufacturer; complete with all fixing accessories, connections, etc., and installed as per site requirement and as directed by the Engineer-in-Charge. |
| 5 | S & F in replacement of surface-mounted LED light fitting, 12/15 Watt, round type, suitable for operation on 240 V AC, 50 Hz, complete as required; the luminaire shall be provided with AN INBUILT MICROWAVE MOTION SENSOR CAPABLE OF AUTOMATIC OPERATION SUCH THAT THE LUMINAIRE GLOWS AT FULL BRIGHTNESS WHEN MOTION IS DETECTED AND DIMS TO A PRESET LOWER LEVEL IN THE ABSENCE OF MOVEMENT (auto-dim after 3 minutes of inactivity); the fitting shall be provided with a high-quality polycarbonate (PC) diffuser and shall have IP20 protection against dust ingress, suitable for indoor applications; the LEDs used shall have luminous efficacy ≥100 lumen/watt, CCT 6500K (cool daylight), CRI ≥80, power factor ≥0.90, and surge protection minimum 2.5 kV; the luminaire shall be complete with a high-efficiency constant current LED driver, and both luminaire and driver shall be BIS registered and of the same make/manufacturer; the brand name shall be permanently embossed/engraved on the luminaire body/accessories/end caps and not applied by sticker or screen printing; complete with all fixing accessories, connections, and commissioning, as per site requirement and as directed by the Engineer-in-Charge. |
| 6 | All as per item No 5 in here before but 18/20 W. |
| 7 | S & F in replacement of 3 Watt LED wall-mounted light fitting, suitable for operation on 230 V, single phase, 50 Hz AC, of flexible gooseneck type for patient/bedside use, complete as required; the luminaire shall be plug-in or direct connection type and provided WITH INBUILT USB CHARGING PORT FOR MOBILE PHONE CHARGING, suitable for bedside applications; the fitting shall have a focused beam for reading / precision tasks with flexible gooseneck arm for easy adjustment of light direction, and provided with manual ON/OFF switch on the fitting; the luminaire shall be of black finish with warm white light output (CCT 2700K–3000K) to provide comfortable and glare-free illumination suitable for bedside environments; complete with all fixing accessories, connections, and commissioning, as per site requirement and as directed by the Engineer-in-Charge. |
| 8 | S & F in replacement of LED COB Downlight: Supply and fixing in replacement of ceiling recessed LED COB light fitting, 15W, ≥110 lm/W, CCT 4000K, PF ≥0.95, 50,000 hrs life, with minimum 3.5 kV surge protection, die-cast aluminium housing, complete with BIS registered LED and driver (same make), suitable for 230V AC supply, including all connections, accessories, testing and commissioning, complete as specified and directed. |
| 9 | S & F in replacement LED Track Light fitting 20W, lumen output ≥ 2000 lm, CRI ≥ 80, CCT 3000K/4000K, adjustable beam (24°–60°), die-cast aluminium housing with powder coating, integral driver, suitable for track mounting complete all as specified and directed |
| 10 | S & F in replacement of Aluminium Track (2/3 wire system) with copper conductors, powder coated including suitable end cap units / connectors, suspension kit / mounting brackets etc complete all as specified and directed |
| 11 | SITC in replacement LED Strip Light (230V AC driverless type, 10–12 W/m), lumen output ≥ 900–1000 lm/m, CRI ≥ 80, CCT 3000K/4000K/6500K, flexible PVC coated, IP65 suitable for indoor/outdoor use including power connector with rectifier plug & end cap complete all as specified and directed |
| 12 | Supply, Installation, Testing& Commissioning (SITC) in replacement of Aluminium profile /channel with diffuser for strip light complete all as specified and directed |
| 13 | Supply, Installation, Testing& Commissioning (SITC) in replacement Antique style outdoor LED wall light fitting (10–15W), lumen output ≥ 900–1500 lm, warm white (3000K), decorative antique finish (black/brass), aluminium die-cast housing with clear/opal glass diffuser, IP54/IP65 weatherproof, suitable for wall mounting, complete with LED driver/lamp complete all as specified and directed |
| 14 | M & L in replacement of Sub-Main Wiring with 2 runs of 10 sqmm FRLS, PVC insulated, unsheathed, stranded copper conductor cable (ISI marked) drawn in PVC conduit of suitable size, including all conduit accessories, along with 1 run of 10 sqmm FRLS copper cable as earth continuity conductor, complete with thimbles, terminations, and connections from main DB/Panel to sub DB, including dismantling and removal of existing sub-main wiring, cutting and making good chases, and finishing with cement mortar (1:4) matching existing surface, complete in all respects as specified and directed. |
| 15 | M & L in replacement of Sub-Main Wiring with 2 runs of 6 sqmm FRLS, PVC insulated, unsheathed, stranded copper conductor cable (ISI marked) drawn in PVC conduit of suitable size, including all conduit accessories, along with 1 run of 6 sqmm FRLS copper cable as earth continuity conductor, complete with thimbles, terminations, and connections from main DB/Panel to sub DB, including dismantling and removal of existing sub-main wiring, cutting and making good chases, and finishing with cement mortar (1:4) matching existing surface, complete in all respects as specified and directed. |
| 16 | M & L in replacement of Sub-Main Wiring with 2 runs of 4 sqmm FRLS, PVC insulated, unsheathed, stranded copper conductor cable (ISI marked) drawn in PVC conduit of suitable size, including all conduit accessories, along with 1 run of 4 sqmm FRLS copper cable as earth continuity conductor, complete with thimbles, terminations, and connections from main DB/Panel to sub DB, including dismantling and removal of existing sub-main wiring, cutting and making good chases, and finishing with cement mortar (1:4) matching existing surface, complete in all respects as specified and directed. |
| 17 | SITC PVC insulated Copper Conductor (sheathed), flexible cable, 1100 volts grade of size 4 core, 25 Sq mm including securing the cable on wall / cable tray with suitable fastners etc complete all as specified and directed |
| 18 | SITC PVC insulated Copper Conductor (sheathed), flexible cable, 1100 volts grade of size 4 core, 16 Sq mm including securing the cable on wall / cable tray with suitable fastners etc complete all as specified and directed |
| 19 | SITC PVC insulated Copper Conductor (sheathed), flexible cable, 1100 volts grade of size 4 core, 10 Sq mm including securing the cable on wall / cable tray with suitable fastners etc complete all as specified and directed |
| 20 | S & F in repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed. |
| 21 | S & F in repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed. |
| 22 | S & F in repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, TPN 4 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed. |
| 23 | S & F in repairs MCB, SPN, 63 Amps capacity, 240V, B Curve type, 10kA, double pole with over load and short circuit protection complete all as specified and directed |
| 24 | S & F in repairs MCB, TPN, 63 Amps capacity, 415 V, B Curve type, 10kA, with over load and short circuit protection complete all as specified and directed |
| 25 | S & F in repairs MCB, SP, 40 to 63 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed |
| 26 | S & F in repairs MCB, SP, 6 to 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed |
| 27 | SITC in replacement of 630 Amps Compact Type Bus Trunking, 50 kA for 1 sec, (3L+N+PE), with Class-F insulation, 100% neutral, 1.6 mm GI enclosure, IP-55 indoor type, complete with standard accessories expansion joints, fire barrier, provision of tapping, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required including taking out old existing XLPE cable. |
| 28 | SITC in replacement 630 Amps Compact Type Bus Trunking, 50 kA for 1 sec, suitable for 3 Phase, 4 Wire (3L+N+PE) system, with Class-F insulation and 100% neutral, enclosed in minimum 1.6 mm GI sheet housing with weatherproof construction (IP-65) suitable for outdoor installation, complete with expansion joints, fire barriers, provision for tap-off points, adaptor boxes, copper flexible joints, continuous earthing with two aluminium strips (one on each side), and all necessary GI clamping brackets, suspenders, angle iron supports, steel fasteners, duly connected to the earthing system, including dismantling and removal of existing XLPE cable, complete in all respects as specified and directed. |
| 29 | Supply, Installation, Testing& Commissioning (SITC) 90° Horizontal/Vertical bends/elbows / T Bends suitable for 630A bus trunking system |
| 30 | Supply, Installation, Testing& Commissioning (SITC) End Cap suitable for 630A bus trunking system |
| 31 | Supply, Installation, Testing& Commissioning (SITC) 630 Amps End Feed Unit, to existing bus trunking/rising mains, having 50 kA for 1 sec, suitable for 3 Phase, 4 Wire, 415 V, 50 Hz AC supply, fabricated from 1.6 mm thick CRCA sheet, powder coated, complete with provision for MCCB (MCCB not included), necessary jointing kits, supports, clamping brackets, fasteners, and earthing connections, complete in all respects as required. |
| 32 | Supply, Installation, Testing& Commissioning (SITC) 63 Amps Plug-in/Tap-off Box to existing compact type bus trunking/rising mains, having 15 kA short circuit withstand capacity for 1 second, suitable for 3 Phase, 4 Wire, 415 V, 50 Hz AC supply, fabricated from 1.6 mm thick CRCA steel sheet, powder coated, complete with suitable rating MCCB (included), internal connections, plug-in contacts, and all necessary accessories such as clamping brackets, supports, fasteners, and earthing connections, complete in all respects as required. |
| 33 | S & F in replacement MCCB, 630 Amps(Ics=100%lcu), 4 Pole (TPN), suitable for 415V, 50 Hz AC, with breaking capacity ≥ 50 kA, thermal-magnetic, conforming to IS/IEC 60947-2, complete with terminal connectors, mounting accessories, and interconnections, suitable for installation in End Feed Unit of bus trunking, complete as specified and directed. |
| 34 | M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level connected with earthing lead of 32 x 6 mm galvanised iron strip by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to and including earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil up to 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made but at 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed. |
| 35 | M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed |
| 36 | Supply, Installation, Testing& Commissioning (SITC) in replacement of DLP PVC trunking of size 80x50 mm, with top cover, L Bend, T etc as reqd on site, including fixing on wall for securing the cable, wire etc complete all as specified & directed |
| 37 | Supply, Installation, Testing& Commissioning (SITC) in replcement of Main Display Unit for Nurse Call System comprising 3 × 3 FND (7-segment LED, 3 digits × 3 display windows) with minimum 20-call memory (FIFO logic), displaying first three calls with automatic queuing and re-sequencing on cancellation, with facility for call cancellation from call points and central cancel function, complete with high-brightness alphanumeric LED display, minimum 20–22 selectable audio tones with volume control, microcontroller-based system with non-volatile memory, suitable for operation on 230V AC supply through 12V DC, 1.5A SMPS adaptor, housed in powder-coated metal / ABS enclosure, wall-mountable, and including all wiring, interconnections, accessories, integration with existing system, earthing, testing and commissioning, complete in all respects as specified and directed. |
| 38 | Supply, Installation, Testing& Commissioning (SITC) in replacement of Call–Cancel Unit with 6 push buttons (configurable as 5 Call + 1 Cancel or 3 Call + 3 Cancel), suitable for hospital use, with wireless RF communication range of 30–50 m indoors and up to 100 m in open area, operating on 3V lithium coin cell battery with minimum 12–18 months life and low-battery indication, housed in fire-retardant, sealed ABS enclosure with easy-to-clean surface, having distinct button identification for different calls, complete with inbuilt transmitter, pairing with existing nurse call system, mounting accessories, testing and commissioning, ensuring reliable patient–nurse communication as per NABH guidelines, complete in all respects as specified and directed. |
| 39 | Supply and fixing in replacement of cabled push-button unit with 2-way (Call/Cancel) or 3-way (Call/Cancel) configuration, complete with flexible spiral (coiled) cable of suitable length for tension-free operation, having clearly identified, durable push buttons, housed in fire-retardant ABS enclosure suitable for hospital use, and including all wiring, connections, mounting accessories, integration with existing nurse call system, testing and commissioning, ensuring reliable patient–nurse communication as per NABH guidelines, complete in all respects as specified and directed. |
| 40 | M&L for acrylic signange plate complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender