Tender For Repair/Maintenance Of E/M Installations Bldgs (Water Supply) And Allied Works At Ahrr Under Ge E/M repair renovation Hospital Delhi Cantt-10
Tender Value
29.98 Lakhs
Estimated cost
Bid Submission
31 Jul 2026
5 days left
EMD
59975
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintenance Of E/M Installations Bldgs (Water Supply) And Allied Works At Ahrr Under Ge E/M repair renovation Hospital Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area not exc 1.5 Sqm each of any type steel/wooden all as specified. |
| 2 | Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area exc 1.5 Sqm and not exc 4 Sqm each of any tpye steel/wooden all as specified. |
| 3 | S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face with particle board core, supplying & fixing in frame at site as per specification & drawing (colour & pattern as approved by Engr-in-Charge), complete all as specified and directed. |
| 4 | S&F solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube S&F in opening as per specification and drgs, complete all as specified. |
| 5 | S&F for fixing in repairs 3 mm thick sheet glass of selected quality and make conforming to IS: 2835 in wooden/ steel-windows/ ventilator including cutting to required size, bedding & fixing by Oil Putty & glazing clips or beads/ Neoprene/ EPDM rubber gasket/ Steel sleve or collar or rebate (as the case may be) including necessary wooden/ aluminium glazing beads, screws, clips, distance pieces, polysulphate sealent where ever required in bldg, including hacking out old sheet glass complete all as specified. Note : Item will be used for replacement of glass in window panes at Building hight upto 10 m. Cost includes for making enough arrangements for manpowers (labours)/ Tools (ladder etc.) for this item. No claims in this regard will be entertained during currency of work. |
| 6 | S&F for fixing in repairs18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work 25mm wide, 6mm thick 2nd class HW lipping on edges including dismantling complete all as specified and directed. |
| 7 | S&F steel window/ventilator 1.25 mm thick Box type (Primer coated) ERW hollow P section of size 60 mm x 25 mm single rebated comprises glazed and gauzed skelton shutter EWR sec 50 mm x 20 mm and 1 mm thick and two openable leaf consisting two Nos sash bar of T- section 20 mm x 3 mm complete welded to frame with one vertical mullion of EWRR box type T- section of size 60 mm x 25 mm and 1.25 mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B-1 four Nos for each window including following fittings welded to failed shutters (Hold fasts 150 mm long of 12 mm x 3 mm made to shape-04 nos per window. (b) Handle of Z sec 20 mm x 25 mm, 100 mm long-1 Nos of leaf (c) MS tower bolt 150 mm long 02 Nos per leaf. (d) Z sec 20 mm x 25 mm , 100 long of hollow square 15 mm x 20 mm x 63 mm welded to hinges – 01 Nos per leaf (f) MS pintal hinges of size 75mm x 12 mm -02 Nos per lear (g Fabrication and fixing arrangement as per drawing including taking down of old u/s window.Note: Glass and painting shall be measured and paid separately under appropriate items. |
| 8 | Ditto as per description of item No 7 above but in gauzed shutters without sash bars all as specified and directed by Engr-in-charge |
| 9 | S&F for fixing in repairs hot dip galvanised mild steel wire conforming to IS : 4826 cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed in wooden/steel windows/ ventilator including cutting to required size, in Wooden/ Steel sleve or collar or rebate (as the case may be) including with necessary wooden/ screws, clips, tinned tacks where ever required in bldg upto hight 10 m, each panes complete all as specified.Note: Item will be used for replacement of window panes in window panes at Building hight upto 10 m. Cost includes for making enough arrangements for manpowers (labours)/ Tools (ladder etc.) for this item. No claims in this regard will be entertained during currency of work. |
| 10 | S&F 250mm long mild steel sliding door bolts stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified. |
| 11 | S&F 100mm size butt hinges medium weight cold rolled mild steel complete all as specified and as directed. |
| 12 | S&F 200mm long mild steel tower bolt stove enamelled black with bright bolt complete all as specified. |
| 13 | S&F 150 mm mild steel pressed handles oval type, stove enamelled black all as specified. |
| 14 | S&F for fixing in repairs beveled edge looking mirror size 450mm x600mm of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and aluminium frame, fixed with PVC gutties with chromium plated brass screws and cup washers complete all as specified. |
| 15 | S&F aluminium anodised barrel tower bolt of extruded section 150 mm long fixed with machine screws. |
| 16 | S&F aluminium anodised bow handle 150 mm long fixed with machine screws. |
| 17 | S&F in repair mild steel 300 mm ordinary rat rail rod pattern springs including roller and roller plate complete. |
| 18 | Dismantling of Asbestos cement (corrugated , semicorrugated , etc.) sheets as in roof coverings. |
| 19 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenth of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws all as specified and as directed. |
| 20 | M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or eges of landings, steps, cills, sunshades, shelves, lintels, etc; and cutting chases for embedding Galvalume sheet, etc. and making good, cutting not exceeding 10 cm girth complete all as specified and as directed. |
| 21 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as spcifed and directed. |
| 22 | M&L for steel work in tublar trusses including special shaped washer erc. complete using or incuction butt welded tubes conforming to IS 1161-1979 grade St.-240 , complete all as specified and directed. Note for item No 18 to 22 :- Item will be used for repair/replacement of sheds at Building hight upto 10 m. Cost includes for making enough arrangements for manpowers (labours)/ Tools (ladder etc.). No claims in this regard will be entertained during currency of work. |
| 23 | M&L for prepration of new or previously untreated steel surfaces, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed. |
| 24 | Demolition of stone slabs or tiles of any description or thickness in any position laid, bedded and pointed in any mortar, complete all as specified & directed. |
| 25 | M&L for 18-20 mm thick machine cut kota stone slab flooring laid over and including 20 mm thick screed bed or bedding layer in CM 1:6, jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding, rubbing and polishing, complete all as specified and as directed. |
| 26 | M&L kota stone slab 20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including 10mm thick screed bed or bedding layer in CM 1:4, complete all as specified and directed . |
| 27 | M&L for prepration of old painted surfaces steel surfaces, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint over steel surface complete all as specified and as directed. |
| 28 | M&L for prepration of old painted surfaces wooden surfaces, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint over steel surface complete all as specified and as directed. |
| 29 | Demolition of brick work built in cement mortar complete all as specified. |
| 30 | Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radious built in cement mortar 1:6 complete all as specified. |
| 31 | Demolition of Conctrete of any description and in any position not otherwise specifically provided for; complete all as specified and as directed. |
| 32 | M&L for cement concrete Type D-2 (1:4:8, 40 mm graded aggregate) in foundations, filling and mass concrete complete all as specified and as directed. |
| 33 | M&L for cemenent concrete 25 mm thick type B-0, 1:2:4 (12.5 mm graded aggregate) complete all as specified and as directed |
| 34 | Providing and laying 60 mm thick factory made chamfered ement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & Pattern over and including 50 mm thick compacted baed of fine sand, compacvting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 35 | M&L for cement concrete Type B-1 (1:2:4, 20 mm graded aggregate) in roof kerbs or mud stops, rounded or chemfered edges complete all as specified and as directed. |
| 36 | M&L for repair to 75 mm thick cement concrete (1:3:6) type C-2, using 40mm graded crushed stone aggregate finished even and fair over 75 mm hardcore, laid to slope of 1 in 12 and be laid in alternate bay not exceeding 3 m length with joint to be filled with bitumenous mastic (cost of bitumenous mastic) included filling comprising a mixture of 1 part of heated hot blown bitumen 85/25 penetration and two parts of heated sand as in plinth protection, surfaces complete all as specified and as directed. |
| 37 | M&L for non skid ceramic tiles/ non skid tiles coloured 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as per the existing tiles and size as suitable/ matching with the existing tiles in dados/ floors set and jointed in tile adhessive (Type-I) and pointed in white or coloured cement to match with tile,including screed bed or bedding layer 15 mm thick in CM (1:6) complete all as specified and directed. |
| 38 | M&L for Non skid ceramic coloured 7 to 8 mm thick area of each tile exc 0.11 sqm but n.exc 0.18 Sqm on vertical surface such as skirting/dado etc. set and jointed in tile adhessive (Type-I) and pointed in white or coloured cement to match with tile laid over and including screed plaster 10 mm thick in CM (1:4) complete all as specified and directed. |
| 39 | Cleaning of RCC surface to remove dust, loose particles, etc with compressed air jet depending on site condition, grinding any sharp edges, etc complete all as per specified and as directed. |
| 40 | M&L for identify the crack location on parent structure after clean or removal of cover and making 'V' groove of 10 mm wide and 10 mm deep cover crack line by electrically operated angle grinder with dimond concrete saw blade and cleaning it by air pressure complete all as specified and as directed. |
| 41 | M&L for Sealing of exposed 'V' groove of 10 mm deep and 10 mm wide with solvent-free, moisture tolerant, thixotropic, structural adhessive and repair mortar, based on epoxy resins and special fillers, designed for use at temperature between +10C and +40C. Product should conforms to ASTM C881-78, Type-I Grade 3, class B+C: compressive strength more than 60N/ Sq mm(14 days) according to ASTM C881 : bond strength less than 10 N/sq mm (7 days) according to ASTM C882 all as per manufacturer's instructions & directed.Make: Sika/Fosroc/Pidilite |
| 42 | M&L for drilling holes 10 mm diameter in structural concrete at the interval as per recommendation of Engineer-In-Charge, clean the holes by air blower prior of fixing nozzles, fixing of packers 9.8 mm diameter, 10 cm long, with high strength steel screw and structure rubber sealing in cleaned holes & cutting packers by cut of wheel after completion of grouting without damaging structural elements all as specified and as directed. |
| 43 | M&L for applying one component, polyurethane injection foam based system for wet condition and temporary sealing, which cure to dense flexible foam with a fine cellular structure, Viscosity cps 500-1300 at 23C all as per manufacture's instructions & directed. Make: Sika/Fosroc/Pidilite |
| 44 | M&L for applying two component, CE certificate, elastic, low viscous, solvent freem, polyurethane injection resin based for permanent sealing, that does not need the presence of water for hardening reaction, Viscosity of mixture 250-600 mPaS ( at +30C) all as per manufacturer's instructions & dirtected. Make: Sika/Fosroc/Pidilite |
| 45 | M&L for cleaning the RCC surface, with high pressure water jet to remove any loose laitance etc. sturating the concrete surface and thereafter, applying 1-Part cementitious waterproofingb slurry modified with selected aggregates and active chemicals. The active component migrate within the concrete porte and capillary network and reacts with the avilable moisture and free lime to form a non-soluble crystalline structure within the network. The slurry applied in two coats by brush or spray and provides a waterproof layer to prevent the penetration of water to all types of concrete structure @ 1.2 kg per Sqm per coat (2.4 kg per sqm for two coats) over the RCC slab and on the vertical surface as per manufacturer;s instruction & direction. Make: Xypex/Penetron/Kryton |
| 46 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc and removing surplus spoil out of Defence Land where directed at a level not exc 1.5 m above the starting point all as specified |
| 47 | M&L 12 mm thick cement plaster in cement mortar 1:6 on internal surface of brick or concrete surface finished even and smooth without using extra cement all as specified. |
| 48 | M&L 15 mm thick cement plaster in cement mortar 1:4 on external surface of brick or concrete surface finished even and smooth without using extra cement all as specified. |
| 49 | M&L 5 mm thick cement plaster in cement mortar 1:3 on ceiling on concrete surface finished even and smooth without using extra cement all as specified. |
| 50 | M&L for preparing new surfaces plastered or unplastered surfaces of walls by applying two coats of oil bound distemper over a coat of primer complete all as specified. |
| 51 | M&L for preparing new surfaces plastered or unplastered surfaces of walls by applying two coats of cement base paint over a coat of primer complete all as specified. |
| 52 | M&L for preparing new surfaces of ceiling by applying two coats of oil bound distemper over one coat of primer on ceiling surface complete all as specified. |
| 53 | M&L for preparing old surfaces of walls by Washing rubbing down and stopping of distempered and painted surfaces and applying one coats of oil bound distemper complete all as specified. |
| 54 | M&L for preparing old surfaces plastered or unplastered surfaces of walls & applying one coats of cement base paint complete all as specified. |
| 55 | M&L for preparing old surfaces of ceiling by applying two coats of oil bound distemper on ceiling surface complete all as specified. |
| 56 | M&L for followings :-(i) Removing plaster & finishes from all exposed / damaged portion of columns, slabs & beams.(ii) After cleaning, gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible).(iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed & full length of bar where directed).(iv) Cleaning exposed concrete substrate by using water jet.(v) Removing visible rust along the length of reinforcement exposed concrete substrate by approved method.(The Engr-in-charge may order sand blasting of the length of reinforcement using hand tools as directed by Engr-in-charge to present clean surface if rust is approved).(vi) Any other work as complete all as specified and directed by Engr-in-charge. |
| 57 | M&L for providing rust proof / anti corrosive treatment to bars :-(i) Cleaning of all exposed bars (new & old) around.(ii) Apply a single coat of Alkaline rust converting primer on around bars new & old as recommended by the manufacturer.(iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars around new & old as recommended by the manufacturer.Note : Anti corrosive treatment shall be continuous especially in the regions where pitting, imperfections, etc. were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating.Make: Sika/Fosroc/BASF MasterEmaco |
| 58 | M& L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as spd and directed. |
| 59 | M&L for Drilling & chemical anchoring of new rebars/stirrups :-(i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :-8 mm dia bar - drilling length 80 to 100 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item).Make: Sika/Fosroc/BASF MasterFlow |
| 60 | M&L for providing PMM (Polymer modified cementitious mortar) :-(i) Dry sub strate surface and free of debris and dust(ii) Applying Epoxy bond coat on the sound substrate using approved apray machine & ensuring that no pin holes are visible (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitoius mortar) of 25-50mm thickness.Note : Application of PMM sghall of preferably be in coats of approx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed within 30mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufacturer cmplete all as specified and directed.Make: Sika/Fosroc/BASF MasterEmaco |
| 61 | Use and waste for Formwork to repaired chajja, beam, concrete chajjas, troughs and similar items including edges and fair finished all as spd and directed |
| 62 | M&L for comprehensive repair, servicing maintenance to steel rolling shutters including the following operations complete all as directed by Engineer-In-Charge: (i) Opening/closing the top hood/cover for access.(ii) Complete cleaning of gear box, axle, coil springs, guide channels, chain sprocket, pulleys and all moving/revolving parts by removing old/dried grease, dust, dirt and rust.(iii) Oiling and greasing of all gears, ball bearings/bush bearings, chain pulley, sprocket, hook lock and other revolving/moving parts with high quality multipurpose grease (Lithium base or equivalent, IOC/HP make) and lubricating oil where required.(iv) Repair/replacement of worn-out/defective ball bearings (including supply & fixing new bearings of size 6204/6205 or equivalent, SKF/FAG/NBC make), bush bearings/sleeves if needed.(v) Minor repair/replacement of gear wheel/pinion (supply & fixing new MS/CI gear if teeth damaged/worn).(vi) Checking & adjusting coil spring tension for smooth manual operation.(vii) Tightening all loose nuts/bolts, straightening minor bends in guide channels/bottom rail if required, minor welding/fabrication on brackets/parts if necessary.(viii) Lubricating chain, locking arrangement (hasp staple, inside-outside lock) and all accessories.(ix) Testing full up-down operation for smoothness, making necessary adjustments and ensuring no jamming/noise.(x) Closing hood/cover, touch-up painting on repaired parts with red oxide + enamel paint (if minor welding done), and leaving the shutter in fully functional condition. |
| 63 | S&F for fixing in repairs to 1 mm thick steel rolling shutters, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; errected in position gear operated type with bevel gear box and crank complete all as specified and as directed. |
| 64 | Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan/plug/bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof/ wall/ floor by applying putty and applying colour/ white wash finish complete all as specified and directed. Please Enable Macros to View BoQ information |
| 65 | Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan/plug/bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof/ wall/ floor by applying putty and applying colour/ white wash finish complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender