Tender For Provn Of Medicinal Gas Store And 02 X Toilet Block I Opd Complex Of Mh , Toilet Block In Bldg No P-154 At 263 Fd Wksp Coy At Inf Lines In Jamnagar Mil Stn Under Ge Jamnagar.
Tender Value
38.50 Lakhs
Estimated cost
Bid Submission
03 Aug 2026
22 days left
EMD
77000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Medicinal Gas Store And 02 X Toilet Block I Opd Complex Of Mh , Toilet Block In Bldg No P-154 At 263 Fd Wksp Coy At Inf Lines In Jamnagar Mil Stn Under Ge Jamnagar.
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation n .exc 30cm deep and average 7.5 cm deep in hard / dence soil and getting out to excavated soil complete all as specified and directed by Engr-in-Charge. |
| 2 | Surface excavation exc 30cm deep and avg 30 cm deep in hard / dence soil and getting out to excavated soil complete all as specified and directed by Engr-in-Charge. |
| 3 | Earth work in excavationby mechanical means(Hydraulic excavator)/ infoundation trenches ordrains (not exceeding 1.5 min width or 10 sqm onplan), including dressingof sides and ramming ofbottoms, lift upto 1.5 mincluding getting out theexcavated soil and disposalof surplus excavated soil asdirected, within a lead of50 m of any kind of soil complete all as specified and directed by Engr-in-Charge. |
| 4 | Returning & filling including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-Charge. |
| 5 | Removal of excavated material n.exc 50 mtr and depositing where directed at level not exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 8 | M & L for RCC M-30 design mix as in foundation, including rafts , footings , foundation beams, plinth beams; bases for columns, etc ; basement slabs, under- reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 9 | M & L for RCC M-30 design mix as in columns, pillars, piers, posts and struts etc complete all as specified and directed by Engr-in-Charge. |
| 10 | M & L for RCC M-30 design mix as in Beams , cantilevers, bressummers, lintels over 1.5 m span etc complete all as specified and directed by Engr-in-Charge. |
| 11 | M & L for RCC M-30 design mix as in slabs supported on walls, beams and columns in floors , roofs, landings , balconies, canopies, deck slabs and shelves etc complete all as specified and directed by Engr-in-Charge. |
| 12 | M & L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips etc complete all as specified and directed by Engr-in-Charge. |
| 13 | Ditto all as per item No 12 above but 6mm to 8mm dia complete all as specified and as directed by Engineer -in-Charge. |
| 14 | M&L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia in strirrups, spaces and binder and including mild steel wire (annealed) not less than 0.9mm dia etc complete all as specified and directed by Engr-in-Charge. |
| 15 | M & L for form work to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams: and similar works; vertical or to batter for flat rough finished surfaces complete all as specified and directed by Engr-in-Charge. |
| 16 | M & L for form work to sides and soffits of suspended slabs such as roof slabs , landings and similar work not exc 200 mm thick (horizontal or sloopping) for flat rough finished surfaces complete all as specified and directed by Engr -in Charge. |
| 17 | M & L for form work to sides and soffits of floor or roof beam, beam hauchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc for flat rough finished surfaces complete all as specified and directed by Engr -in Charge. |
| 18 | M & L for form work to sides of pillars, posts, struts, piers, columns and stanchions size of square, rectangular or polygonal for flat rough finished surfaces complete all as specified and directed by Engr-in-Charge. |
| 19 | M & L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide of rough finished surfaces complete all as specified and directed by Engr-in-Charge. |
| 20 | Ditto all as per item No 19 above exc 5 cm but not exc.10cm wide complete all as specified and as directed by Engineer -in-Charge. |
| 21 | M&L for brickwork with old size flyash bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 22 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 23 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 24 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 with 3% of WPC and finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 25 | M & L Rendering 5 mm thick on fair faces of concrete or concrete surface in ceiling in CM 1:3, finished even and smooth without using extra cement complete all as specified and directed by Engr -in Charge. |
| 26 | M & L for on site LLDPE septic tank conventional 10 user designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 as in foundation, vent shaft, connection etc complete all as specified and directed by Engr -in Charge. |
| 27 | M&L75 mm thick cement concrete type B-2 1:2:4 (40mm graded aggregate) as floor and finishing cement concrete complete all as specified and directed by Engr-in-Charge. |
| 28 | M&L75 mm thick cement concrete type D-2 1:4:8(40mm graded aggregate) as sub base of Floor complete all as specified and directed by Engr-in-Charge. |
| 29 | M & L for applying roof treatment on top of roof with APP modified membrane (minimum 3mm thick) weight not less than 3.00 kg /sqm and reinforced with non-woven polyster reinforcement with thermal insulation with polythene finish on upper side of membrane ,laid by torch application method with overlaps 150mm on length side and100mm on the width side as per manufactures instructions over a coat of approved cold applied bituminous oil based primer @300gm/sqm and applying two coats of aluminium paint 0.20lit/sqm complete all as specified and as directed by Engineer -in-Charge.. |
| 30 | M&L 75 mm thick Cement concrete type C-2, 1:3:6 (40 mm graded aggregate) as in plinth protection complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L for Forming V grooves in plaster n exc 10mm deep and n exc 10mm on face complete all as specified and directed by Engr-in-Charge. |
| 32 | M & L Non skid coloured ceramic tiles 7-8mm thick area of each tiles exceeding .06 Sqm but not exceeding .11 Sqm, in floors etc. set and jointed in neat cement slurry mixed with water proofing liquid compound and pointed in white or coloured grouting chemical to match , over 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 33 | M&L Glazed ceramic coloured designer tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match 0ver 10mm thick plaster in cement mortar (1:3).(Make: Somany/Johnson/Orient Bell or equivalent) complete all as specified and directed by Engr-in-Charge. |
| 34 | S & F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed 150mm complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F in Aluminium handles, cast type, anodised 150mm long complete all as specified and directed by Engr-in-Charge. |
| 37 | S&F fancy type CP bib taps, 15 mm bore with crutch or , screwed down, fixed as in repairs complete all as specified and directed by Engr-in-Charge. |
| 38 | S&F in repairs Fancy type Pillar taps 15 mm dia, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure ,with long screwed shanks and fly-nuts , screwed for iron pipe/cpvc pipe and fixed complete all as specified and directed by Engr-in-Charge. |
| 39 | S&F in repairs 600 mm x 450 mm bevelled edge mirror of selected quality glass,mounted on 6mm thick. AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cap washers complete all as specified and directed by Engr-in-Charge. |
| 40 | S&F in repair Brass chromium plated tubular towel rail 20mm dia D type 60 cm long between flanges complete all as specified and directed by Engr-in-Charge. |
| 41 | S&F CPVC connections 15mm dia with PTMT nuts of length 600mm complete all as specified and directed by Engr-in-Charge. |
| 42 | Supply and fixing in repair PVC flushing cistern, white,10 ltr capacity with 32mm dia flush pipe any length with inlet ,ball valve ,float handle fixed to water closet complete all as specified and directed by Engr-in-Charge. |
| 43 | S & F in repair vitreous China wash basin, white, flat back, size 550mm x 400 mm with a pair of CI brackets, embedded in PCC 1:3: 6 type C-1 using 20mm graded stone aggregate ,block of size 10x7.5x15cm,anf 32 mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts ,flange end bedded in red lead cement and other end fixed including PVC waste coupling of PTMT 32mm dia (half or full thread) minimum wt 45 grms , washers and brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connection including necessary packing, union and cap and fixed complete all as specified and directed by Engr-in-Charge. |
| 44 | S&F in repair Heath faucet (ABCBody) mild steel chromium plated suitable for 15mm dia pipes with 1.25 mtr long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engr-in-Charge. |
| 45 | S&F in repair soap dish of any type (SS) approximate size 160x160 fixed to plugs with chromium plated brass screws including taking down old complete all as specified and directed by Engr-in-Charge. |
| 46 | S & F in repairs 500 litres rotational moulded polyethylene water storage tank, double layered (cylindrical vertical with closed top cover) as per IS-12701-1996 and PTMT 20mm ball valves, float valve, air vent, overflow and high low level switches, ball stop cock 20 mm dia with plastic ball and float valve complete with inlet, outlet and overflow connections including necessary arrangements for fixing inlet, outlet and overflow complete all as specified in SSR Part-I complete all as specified and directed by Engr-in-Charge. |
| 47 | S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type B, single socketed in any length with rubber ring joints, including solvent to join joints complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type B, single socketed in any length with rubber ring joints, laid in floors complete all as specified and directed by Engr-in-Charge. |
| 49 | S&F in repair PVC (SWR) 110 mm bend bore bends with access door any radius complete all as specified and directed by Engr-in-Charge. |
| 50 | S&F in repairs PVC(SWR) bend and junctions, 75 mm dia complete all as specified and directed by Engr-in-Charge. |
| 51 | M&L 75mm outlet dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engr-in-Charge. |
| 52 | Supplying & laying 25mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joints with CPVC adhesive taflon tape in requirement complete to walls and ceilings or laid in floors including all connected brass cpvc fitting sand cutting grooves ,filled with CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 53 | Supplying & laying 20mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joints with CPVC adhesive taflon tape in requirement complete to walls and ceilings or laid in floors including all connected brass cpvc fitting sand cutting grooves ,filled with CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 54 | Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engr-in-Charge. |
| 55 | S & F Vitreous China Squatting Pan ‘ORISSA’ Pattern, size 580X440 mm White, with , Integral Foot Rest, providing Joints between Flush Pipe and Socket of WC Pan (excluding Flushing Cistern and Flush Pipe), and connected Items, complete all as specified and directed by Engr-in-Charge. |
| 56 | S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed by Engr-in-Charge. |
| 57 | Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified and directed by Engr-in-Charge. |
| 58 | M&L for preparation of new plastered surface of wall and applying two coat of white washing complete all as specified and directed by Engr-in-Charge. |
| 59 | M&L for preparation of new plastered surface of wall and applying two coat of cement base paint complete all as specified and directed by Engr-in-Charge. |
| 60 | M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed by Engr-in-Charge. |
| 61 | S&F in powder coated aluminium fixed louvered ventilator, frame of section 63.5mm X 38.1mm X 1.01 mm or appropriate equivalent section with 4 mm thick figured/frosted sheet glass with rubber gasket,Aluminium wire mesh, handles, locking arrangement etc incl making good jambs, cills etc and including taking down old iron ventilator complete all as specified and directed by the Engr-in-Charge. (make: Hindalco/Indal/Jindal or equvalent) |
| 62 | S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed by Engr-in-Charge.(Make: Sintex/Rajshree/ Accucell or equvalent) |
| 63 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engr-in-Charge. |
| 64 | Excavating in trenches not exceeding 1.5 meters wide and not exceeding 1.5 meters deep and getting out in hard / dense complete all as specified and directed by Engr-in-Charge. |
| 65 | Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 150mm bore of pipe plain cement concrete 1:3:6 type C-2 (Using 40mm graded stone aggregates) complete all as specified and directed by Engr-in-Charge. |
| 66 | M&L for salt glazed stone ware(SGSW) drain pipe of grade \\"A\\" of 150mm bore laid in trenches and jointed on concrete bed complete all as specified and directed by Engr-in-Charge. |
| 67 | M&L for RCC NP-2 drain pipe 150 mm internal dia, grade ‘A’ laid in trenches and Collar/push joint all as specified and directed as in repairs complete all as specified and directed by Engr-in-Charge. |
| 68 | M&L for Plain Cement concrete 1:2:4 type B-0 using (12.50mm graded stone aggregate) as in coping, benching channel to manholes etc complete all as specified and directed by Engr-in-Charge. |
| 69 | Precast cement concrete 1:2:4 type B-1 (Using 20mm graded stone aggregates as in manholes cover slabs and set in cement mortar 1:4 complete, complete all as specified and directed by Engr-in-Charge. |
| 70 | Removing excavated materials (soil) to a distance exceeding 250 metres but not exceeding 500 meters and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engr-in-Charge. |
| 71 | Surface dressing n.exc. 15 cm deep and getting out in hard /dense of soil complete all as specified and directed by Engr-in-Charge. |
| 72 | M & L for hardcore of broken stone or boulder of gauge n exc,63mm, deposited,spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed by Engr-in-Charge. |
| 73 | M&L 75mm thick PCC , 1:3:6 type C-2 (40mm graded stone aggt) as in path, hard standing, parking floors, etc., complete all as specified and directed by Engr-in-Charge. |
| 74 | Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engr-in-Charge. |
| 75 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand),including making joints with or without grooves(thickness of joints except at sharp curve shall not to more than 5 mm ), including making drainage opening wherever required complete all as specified and directed by Engr-in-Charge. |
| 76 | M &L cement concrete 1:2:4 type B1 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic, pcc coving of chajja and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stonesed plates, kerbs not provided complete all as specified and as directed by Engineer -in-Charge. |
| 77 | M & L for RCC M-30 design mix as in Chajjas complete all as specified and directed by Engr-in-Charge. |
| 78 | M&L for form work to chajjas and similar item cluding edges for flat rough finished surfaces of concrete complete all as specified . |
| 79 | M & L Pre-cast cement concrete block type C 1 ,1:3:6 (20 mm graded aggregate ) with solid blocks exc 10 cm in width and setting in mortar (1:6) complete all as specified and as directed by Engineer -in-Charge. |
| 80 | M&L 38 mm width plastic dividing strips 1.5mm thick and inserted in position of bases of floor complete all as specified and as directed by Engineer -in-Charge. |
| 81 | M & L for applying roof treatment on top of roof with APP modified membrane (minimum 3mm thick) weight not less than 3.00 kg /sqm and reinforced with non-woven polyster reinforcement with thermal insulation with polythene finish on upper side of membrane ,laid by torch application method with overlaps 150mm on length side and100mm on the width side as per manufactures instructions over a coat of approved cold applied bituminous oil based primer @300gm/sqm and applying two coats of aluminium paint 0.20lit/sqm complete all as specified and as directed by Engineer -in-Charge. |
| 82 | S & F Steel rolling shutters of laths 1.25mm, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type complete all as specified and as directed by Engineer -in-Charge. |
| 83 | S &F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed by Engineer -in-Charge. |
| 84 | S& F 4mm Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer -in-Charge. |
| 85 | S& F MS 3.2mm thick Hollow square 25x25 mm section for the frame work including welding in position complete all as specified and as directed by Engineer -in-Charge. |
| 86 | S &F Mild steel 12mm dia screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long complete all as specified and as directed by Engineer -in-Charge. |
| 87 | S&F MS Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work or of any other section including ornmental CI items for Portions framed and hung as gates, including pintle hinges,stops ,hand-made sliding bolts etc posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire etc,flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer -in-Charge. |
| 88 | S& F of 16mm Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer -in-Charge. |
| 89 | M&L preparation of new untreated Steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and as directed by Engineer -in-Charge. |
| 90 | M&L for preparation of steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat primer surface complete all as specified and as directed by Engineer -in-Charge. |
| 91 | M&L brickwork with old size flyash bricks straight or curved on plan to any radius half brick thick built in CM 1:4 complete all as specified and as directed by Engineer -in-Charge. |
| 92 | Applying evenly a tack coat of industial bitumen primer 85/25 as approved by Engr-in-Charge @ 1.2Kg/sqm over for use in damp proofing treatment on dried surface of concrete including cleaning surface complete all as specified and as directed by Engineer -in-Charge. |
| 93 | Supply and laying , APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150gm/Sqm laid on primed surface by forced application, complete all as specified and as directed by Engineer -in-Charge. |
| 94 | M&L for Rendering 10mm thick in CM(1:3) with using water proofing compound on fair faces of brick work/ Fasia and roof surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer -in-Charge. |
| 95 | M&L 40mm thick PCC 1:2:4, type B0 (using 12.5mm size stone aggregate) using integral WPC as per manufacturer instuctions will compacted with V shaped groove of 10mm deep filled with mastic bitumen size of PCC panel with groove shall not exceeding 0.4 sqm complete all as specified and as directed by Engineer -in-Charge. |
| 96 | Rendering 10mm thick on fair faces on brick masonary or concrete surfaces in cm 1:6 finished complete all as specified and as directed by Engineer -in-Charge. |
| 97 | M&L for Prepration by hand held sander / long handle sander including cornices, pilasters etc of newly plastered on wall complete all as specified directed and applying three coat of white wash, complete all as specified and as directed by Engineer -in-Charge. |
| 98 | M&L 15 mm thick rendering on other than fair faces of external wall of brick masonary or concret surfaces in two layers Ist layer shall be 10mm in cm 1:6, secound and final layer shall be 5mm thick in CM 1:4 finished fair and even without using extra cement mixed with integral water proofing compound complete all as specified and as directed by Engineer -in-Charge. |
| 99 | M&L Prepration of newly plastered surface of wall by hand held sander / long handle sander including cornices, pilasters etc and appliying two or more coats of 100 % premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 litre/10Sqm over and including priming coat of exterior primer applied @ 0.9 ltr/10sqm complete all as specified and as directed by Engineer -in-Charge. |
| 100 | M&L 5 mm thick rendering on ceiling or concret surfaces in cm 1:3 finished even and smooth complete all as specified and as directed by Engineer -in-Charge. |
| 101 | Supply only of liquid water proofing compound as per manufactures instruction complete all as specified and as directed by Engineer -in-Charge. |
| 102 | S&F powder coated anodised aluminium fixed louvered ventilator frame of size 63.5 x 38.1 x 1.01 mm thick or equivalent section fixed in vertical position with aluminium vertical members and half portion to be provided with 4 mm thick pinhead glass and remaining portion to be louvered using 4 mm thick pinhead glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm incl necessary channel frame work, including rubber gasket and aluminium beading including taking down old ventilator in any size and make complete all as specifiedNote : rates shall include all glazing/SS wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading etc complete all as specified and as directed by Engineer -in-Charge. |
| 103 | S & F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer -in-Charge. |
| 104 | M&L preparation of new untreated Steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and as directed by Engineer -in-Charge. |
| 105 | S&F mild steel medium weight cold rolled butt hinges 100 mm long complete all as specified and as directed by Engineer -in-Charge. |
| 106 | S&F aluminium anodised, barrel tower bolt of extruded section 150mm long, complete all as specified and as directed by Engineer -in-Charge. |
| 107 | S&F 125 mm long aluminium handle, cast type, anodised complete all as specified and as directed by Engineer -in-Charge. |
| 108 | S&F aluminium alloy anodised sliding door bolt with hasp staple(bolt type) ,250 mm long,and fixing clip of sheet cast or extruded section or fixing bolt cast aluminium alloy and fixed complete all as specified and as directed by Engineer -in-Charge. |
| 109 | M&L 100 mm thick PCC 1:3:6 type C2 using 40 mm graded stone aggregate in sub base to flooring complete all as specified and as directed by Engineer -in-Charge. |
| 110 | Surface excavation n exc 30cm deep andaveraging 15cm deep and getting out complete all as specified and as directed by Engineer -in-Charge. |
| 111 | M&L for bringing approved moorum/red bajri filling in floors or pavings laid in layers n exc 15cm thick spread levelled and rammed including watering complete all as specified and as directed by Engineer -in-Charge. |
| 112 | M&L for screed bed or bedding 15mm thick in CM 1:4 on floor to receive tile complete all as specified and as directed by Engineer -in-Charge. |
| 113 | S & F Non Skid Ceramic Colour Tiles 7 to 8 mm thick area of each tiles exc 0.06 Sqm but n. exc 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer -in-Charge. |
| 114 | M&L rendering 10 mm thick in CM 1:3 on wall to receive tile complete all as specified and as directed by Engineer -in-Charge. |
| 115 | M& L glazed cermic coloured tile in vertical surfaces 300x450x7 mm thick set and joited in neat cement slurry and poited in white or coloured cement to match complete all as specified and as directed by Engineer -in-Charge. |
| 116 | M & L 75mm for PCC 1:2:4 type C2 (using 40mm graded stone aggregates) as in flooring, finished surface even & smooth without using extra cement laid to slope 1:12 in alternate bays each bay not exceeding 2.5m length, 10mm groove at junction of wall and plinth protection complete all as specified and as directed by Engineer -in-Charge. |
| 117 | Forming construciton joints 30mm deep x 10mm wide filled with sealing compound grade 'B'. complete all as specified and as directed by Engineer -in-Charge. |
| 118 | Supplying and laying of 15 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape in any requirement complete to walls and ceilings or laid in floors iincluding all connected brass cpvc fitting sand cutting grooves, filled with CM1:6 complete all as specified and as directed by Engineer -in-Charge. |
| 119 | Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass cpvc fittings and cutting grooves, filled with CM1:6 complete all as specified and as directed by Engineer -in-Charge. |
| 120 | Supplying and laying of 25 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape in any requirement complete to walls and ceilings or laid in floors iincluding all connected brass cpvc fittingsand cutting grooves, filled with CM1:6 complete all as specified and as directed by Engineer -in-Charge. |
| 121 | S&F Rotational moulded polyethylenewater storage tanks 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed by Engineer -in-Charge. |
| 122 | S & F Ball 25mm brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed incl female brass threaded adaptor on CPVC pipes complete all as specified and as directed by Engineer -in-Charge. |
| 123 | S & F PP-R ball valves (brass insert) as per requirement of the site 25mm dia of pipe incl male brass threaded adaptor on both end of CPVC pipes complete all as specified and as directed by Engineer -in-Charge. |
| 124 | S&F fancy type Bib taps, cast copper alloy 15mm dia with long handle, screwed down, screwed for iron pipe incl female brass threaded adaptor on CPVC pipes complete all as specified and as directed by Engineer -in-Charge. |
| 125 | S&F Fancy type Stop valves angle /concealed 15mm bore, cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed incl female brass threaded adaptor on CPVC pipes complete all as specified and as directed by Engineer -in-Charge. |
| 126 | S&F 110mm PVC (SWR) branch piece double (double Y)equal or unequal with access door complete all as specified and as directed by Engineer -in-Charge. |
| 127 | S&F PVC (SWR)110 mm bend bore bends with access door any radius complete all as specified and as directed by Engineer -in-Charge. |
| 128 | S&F PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer -in-Charge. |
| 129 | S&F 75mm PVC (SWR) branch piece double (double T)equal or unequal with access door complete all as specified and as directed by Engineer -in-Charge. |
| 130 | S & F vitreous china wash down water closet pan (pedestral pattern) white including fixing to flushing cistern and flush pipe and plastic water closet seat cover black closed pattern with flat bottom and cover and mild steel hinging device complete all as specified and as directed by Engineer -in-Charge. |
| 131 | S & F vitreous china squatting pan `Orissa` pattern size 580x440mm white with P or S trap front or back inlet and with intergal foot rests complete all as specified and as directed by Engineer -in-Charge. |
| 132 | Supply and fixing PVC flushing cistern, white, 10ltr capacity with 32mm dia flush pipe any lenth fixed to water closed complete all as specified and as directed by Engineer -in-Charge. |
| 133 | S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm including brackets including cutting for and pinning in ends of brackets or erecting stand including 32 mm waste coupling brass, chromium plated with PVC waste pipe for glazed ware basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer -in-Charge. |
| 134 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed by Engineer -in-Charge. |
| 135 | S&F glass corner shelf 300 mm (with ABS Bracket 300x 600) as selected, complete all as specified and as directed by Engineer -in-Charge..(Make: Prayag,Jaquar,Cera or equivalent) |
| 136 | S&F Soap dish of any type (SS) approximate size 160x160 fixed to plugs with chromium plated brass screws complete all as specified and as directed by Engineer -in-Charge. |
| 137 | S&F Brass chromium plated Tublar towel rail 20mm dia D type 60 cm long between flanges complete all as specified and as directed by Engineer -in-Charge. |
| 138 | S&F 600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed by Engineer -in-Charge. |
| 139 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by Engineer -in-Charge. |
| 140 | S&F 125mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and as directed by Engineer -in-Charge. |
| 141 | S&F PVC (SWR) vent cowl,110 mm dia complete all as specified and as directed by Engineer -in-Charge. |
| 142 | Surface dressing n.exc. 15 cm deep and getting out in hard /dense of soil complete all as specified and as directed by Engineer -in-Charge. |
| 143 | M&L 75mm thick PCC type C-2, 1:3:6 (40mm graded stone aggt) as in path, hard standing, parking floors, etc., complete all as specified and as directed by Engineer -in-Charge. |
| 144 | M&L sand cushing/filling under paver block complete all as specified and as directed by Engineer -in-Charge. |
| 145 | S&F Machine pressed precast Concrete interlocking paver block any shape and size with grey/colour cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 grade complete all as specified and as directed by Engineer -in-Charge. |
| 146 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand),including making joints with or without grooves(thickness of joints except at sharp curve shall not to more than 5 mm ), including making drainage opening wherever required complete all as specified and as directed by Engineer -in-Charge. |
| 147 | M & L for one light point controlled by one, one way switch 5 Amps Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-Charge. |
| 148 | Description all as per item No 147 above but for one exhaust fan point controlled by one, one way switch 5Amps complete all as specified and directed by Engr-in-Charge. |
| 149 | Description all as per item No 147 above but for one 3pin 5Amp switch socket outlet point controlled by one switch on same board complete all as specified and directed by Engr-in-Charge. |
| 150 | Description all as per item No 147 above but for one 3pin 5Amp switch socket outlet point controlled by one switch on independent board complete all as specified and directed by Engr-in-Charge. |
| 151 | Description all as per item No 147 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and directed by Engr-in-Charge |
| 152 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and,cutting chases for concealed water,tubing or concealed conduit wiring,,etc., and making good, cutting not,exc 10 cm girth ®(stone massonary) complete all as specified and as directed by Engineer -in-Charge. |
| 153 | S & F for modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and as directed by Engineer -in-Charge. |
| 154 | S & F for modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and as directed by Engineer -in-Charge. |
| 155 | S & F for ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and as directed by Engineer -in-Charge. |
| 156 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed by Engineer -in-Charge. |
| 157 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed by Engineer -in-Charge. |
| 158 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer -in-Charge. |
| 159 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer -in-Charge. |
| 160 | S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed. Make :- Bajaj Cat No BIBWP 10W LED or its equvalent in Philips, Wipro complete all as specified and as directed by Engineer -in-Charge. |
| 161 | S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed by Engineer -in-Charge. |
| 162 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make :- Make Bajaj Cat part No BCLAB 20W WH LED P, Wipro Cat part No LL20-281-XXX065-ALI or its equvalent in Philips, Havells. complete all as specified and as directed by Engineer -in-Charge. |
| 163 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as specified and as directed by Engineer -in-Charge. |
| 164 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed by Engineer -in-Charge. |
| 165 | Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exc. 1.5 mtr deep for laying of cables and getting out soft/loose soil complete complete all as specified and directed by Engr in Charge |
| 166 | M & L filling dry and clean sand in trenches for cable 8 cm deep below and 15 cm above for cable cushioning complete all as specified and directed by Engr in Charge |
| 167 | Supplying and laying un-reinforced precast concrete cable cover, LV low voltage type -I flat size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-In-charge. |
| 168 | M & L for XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area of 10 sqmm 3 core size laid in trenches under floor/roads/hard standing along poles etc complete all as specified and directed by Engr in Charge. |
| 169 | Supply and fixing GI pipe light grade 40 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah including taking down old unserviceable GI pipe complete all as specified and directed by Engr-in-Charge . |
| 170 | S&F tube GI medium grade 25mm dia with all fittings laid in trenches complete all as specified and directed by Engr-in-Charge . |
| 171 | S&F gun metal valvs with iron wheel head ,screwed both ends for iron pipe and fixed of size 25 mm complete all as specified and directed by Engr-in-Charge . |
| 172 | M & L for point wiring for one light point controlled by one flame switch for point wiring complete with 1100 Volts grade PVC insulated unsheathed copper conductor cable (FRLSH) multistranded of size 1.5 Sqm single core in an including ERW steel conduit, ISI marked surface mounted of suitable size with all accessories and continuous earth wire of size 1.5 sqmm PVC copper conductor cable connected to common earth dully complete all as specified and directed by Engr-in-Charge. |
| 173 | S & F for Switch flame proof rotary type with termination box in LM6, 16A, single pole 250 V complete all as specified and directed by Engr-in-Charge. |
| 174 | Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge. |
| 175 | S&F testing, commissioning of approved make flame proof/ cladded group single phase 4 way distribution board suitable for harardous gas area, febricated from heavy duty CRCA sheet steel/ cast aluminium alloy enclosure with weather proof and dustproof construction complete with hinged door, neoprene gasket, gland plate, earth stud copper bus bar , neutral link with incoming and outgoing mcb, all are specified and directed by eng-in-charge. |
| 176 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion complete all as specified and directed by Engr-in-Charge. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. |
| 177 | M & L for XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area of 16 sqmm 2 core size laid in trenches under floor/roads/hard standing along poles etc complete all as specified and directed by Engr in Charge. |
| 178 | S & F for modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and directed by Engr-in-Charge. |
| 179 | S & F for modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed by Engr-in-Charge. |
| 180 | S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 181 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and directed by Engr-in-Charge. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 182 | S&F for electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed by Engr-in-Charge. |
| 183 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 184 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed by Engr-in-Charge. |
| 185 | S & F for energy efficient exhaust fan of 230 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as specified and directed by Engr-in-Charge. |
| 186 | M & L for XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area of 16 sqmm 3 core size laid in trenches under floor/roads/hard standing along poles etc complete all as specified and directed by Engr in Charge. |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysAug 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender