Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56415418

Tender For Day To Day Maintenace Of Internal Electrification, Light Fittings/Fixtures And Repair/Replacement Of Heating & Cooling Appliances At Af Stn Mandore Under Age E/M, Ge (Af) No 2 Jodhpur

Issued by Statutory Bodies & Commissions/Committees · Jodhpur, Rajasthan
Tender Value
25 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
19 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Day To Day Maintenace Of Internal Electrification, Light Fittings/Fixtures And Repair/Replacement Of Heating & Cooling Appliances At Af Stn Mandore Under Age E/M, Ge (Af) No 2 Jodhpur

BOQ

Name of Work:- DAY TO DAY MAINTENACE OF INTERNAL ELECTRIFICATION, LIGHT FITTINGS/FIXTURES AND REPAIR/REPLACEMENT OF HEATING & COOLING APPLIANCES AT AF STN MANDORE UNDER AGE E/M, GE (AF) NO 2 JODHPUR
Sl. No. Item Description
1Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor (rotary type) of 1.5 TR capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge
2Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor (reciprocating type) of 1.5 capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge
3Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor ( rotary type) of 2 TR capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge
4M&L for servicing of window type/split type AC of 1.5/2.0 tone capacity by taking out the same from existing location, cleaning of condenser, cooling coil, and other components with cooling coil rinse solution and clean water, greasing of fan, motor, blower etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge.Note-Spare parts shall be measured and paid sapertaly.(Note: The contractor shall at his own cost arrange water for servicing purpose.)
5S&F in replacement of starting relay assembly including clips and terminal cover suitable for window type/split type 1.5 TR/2 TR capacity AC complete all as specified and directed by Engr-in-charge.
6S&F in replacement of starting capacitor 80/100/120 MFD including thimble for connection suitable for window type/split type 1.5 TR/2 TR AC complete all as specified and directed by Engr-in-charge
7S&F in replacement of running capacitor 45/50 MFD including thimble for connection suitable for window type/split type 1.5 TR/2 TR AC complete all as specified and directed by Engr-in-charge.
8S&F in repairs blower DC fan motor suitable for 1.5/2.0 Ton split AC of capacity Single Phase for indoor unit complete all as specifed and directed.
9S&F in repairs blower fan motor suitable for 1.5/2.0 Ton split AC of capacity Single Phase for indoor unit complete all as specifed and directed.
10M&L for finding out the leakage with the pressure test of the condenser or cooling coil of window type/split type AC of 1.5/2.0 ton and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging the gas R-22 and testing the AC to the entire satisfaction of Engineer-in-Charge.
11S&F in replacement condenser for window type AC 1.5 ton capacity of any make including charging of gas R-22 all as directed by Engineer-in-Charge.
12S&F in replacement cooling coil for window type AC 1.5 ton capacity of any make including charging of gas R-22 all as directed by Engineer-in-Charge.
13S&F in repairs condensing fan motor 1/5 HP single phase, 230 volts, 50 cycle per second suitable for Carrier window type AC complete all as specifed and directed. Make- as per existing site.
14M&L for replacement of PCB control card suitable for 1.5/2.0 TR capacity split type AC, single phase complete all as specifed and directed.
15Reparing of PCB control card suitable for 1.5/2.0 TR capacity split type AC, single phase complete all as specifed and directed.
16M&L for fan blade of suitable size for 1.5/2 TR capacity of window/Split type AC complete all as specifed and directed.
17S&F in repair copper tube of size ⅝” dia for any capacity of split type AC all as specified.
18M&L for insulating foam pipe of size ⅝\\", ¼\\", and ⅜\\" dia of split type AC any capacity for both indoor and outdoor unit all as specified.
19S&F single pole contactor suitable for split type AC capacity 1.5/2.0 Ton all as per specified and directed.
20S&F in repair of flair nut size 5/8\\" and 1/2\\"dia for any capacity of split type AC all as specified.
21S&F in repair of dead nut size 1/4 '' dia for any capacity of split type AC all as specified.
22M&L for repairs of caplliary tube of split /window type AC capacity 1.5/2.0 Ton and all as per specified and directed.
23Material & labour for WATER JET servicing of CASSET TYPE AC's of 2.5/4/5.5 Tonne capacity (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top cover outdoor top cover from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge. (Note: The contractor shall at his own cost arrange water for servicing purpose.)
24Supply and filling refrigerant gas R-22 for charging in AC complete all as specified and directed by Engr-in-charge.
25Supply and filling refrigerant gas R-410 for charging in AC complete all as specified and directed by Engr-in-charge.
26Supply and filling refrigerant gas R-32 for charging in AC complete all as specified and directed by Engr-in-charge.
27Supply and filling refrigerant gas R-134A for charging water coolers/refrigerators complete all as specified and directed by Engr-in-charge.
28M&L for servicing of water cooler any capacity by taking out the same from existing location, cleaning of condenser, cooling tank, and other components with cooling tank rinse solution and clean water, greasing of fan, motor, etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge.Note -Spare parts shall be measured and paid separtely.
29S&F in replacement of starting relay open type suitable for compressor of water cooler with clips, relay cover and screws complete all as specified and directed by Engr-in-charge.
30S&F in replacement of thermostat switch including knob, plate, screws and necessary wiring of water cooler complete all as specified.
31S&F in replacement of starting capacitor 40/60 /80/100MFD of water cooler complete all as specified and directed by Engr-in-charge.
32S&F in replacement of running capacitor 36/45 MFD of water cooler complete all as specified and directed by Engr-in-charge
33Taking down and dismantling condencing fan motor of water cooler and material and labour for rewinding with supper enamelled copper winding wire as per existing pattern including replacement of gun metal bushes, shaft, clamps including testing and commissioning complete all as specified and directed by Engr-in-charge.
34M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 150/150 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair of the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler to the entire satisfaction of the Engineer-in- Charge.
35M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 60/120 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair of the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler to the entire satisfaction of the Engineer-in- Charge.
36Opening and disconnecting the defective unserviceable sealed compressor unit of refrigerator of any make and type AC 230 volts single phase of capacity 180-220 ltr and supply and fixing new compressor of existing make and model and including gas charging 134A complete all as specified and directed by Engr-in-charge.
37M&L for servicing of refrigerator any capacity by taking out the same from existing location, cleaning of condenser, freezer, and other components with freezer rinse solution and clean water, greasing of fan, motor, etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge.
38S&F in replacement of relay assembly suitable for 180-320 litre capacity refrigerator including relay cover, clips and screws complete all as specified and directed by Engr-in-charge.
39Dismantling and taking out of burnt fan motor of desert coolers for upto 4000 CFM and material and labour for rewinding with supper enamelled copper winding wire of existing pattern, repair of shaft including replacement of insulation material, bushes, nuts, bolts, testing and commissioning etc complete all as specified and directed by Engr-in-charge.
40S&F in replacement of fan motor of desert cooler suitable for upto 4000 CFM single phase, cu winding 230 volts, 3 speed with capacitor and bracket including connection to switch and testing complete all as specified and directed by Engr-in-charge.
41S&F in replacement of submersible type water pump of desert cooler AC single phase 230 volt including necessary wiring connection and testing complete all as specified and directed by Engr-in-charge.
42S&F in replacement of selector switch 3 speed 15 Amps for desert cooler complete all as specified and directed by Engr-in-charge.
43S&F in replacement of shutters of desert cooler of existing size made out of GI sheet handles duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
44S&F in replacement of body parts of desert cooler bottom tank as per sample made out of 1.25 mm thick complete all as specified and directed by Engr-in-charge.
45S&F in replacement of capacitor of capacity 4 MFD for motor of desert cooler complete all as specified and directed by Engr-in-charge.
46S&F in replacement of switch piano flush type 5 Amp one way for water pump of desert cooler complete all as specified and directed by Engr-in-charge.
47S&F in replacement of front grill of desert cooler as per sample made out of 1.25 mm thick GI sheet of size 520mmx550mm (approximate) complete with air control fins, mild steel CP screws, duly spray painted with synthetic enamel paint complete all as specified and directed by Engr-in-charge.
48S&F in replacement of fan blade of fan motor of desert cooler as per sample made out of mild steel duly spray painted with synthetic enamel paint and fixed with mild steel CP screws complete all as specified and directed by Engr-in-charge.
49S&F in replacement of PVC sheathed cable 3 core copper conductor of size 70/.0076mm, flexible for making connection of window type AC complete all as specified and directed by Engr-in-charge.
50S&F in replacement of plug top 3 pin 5 Amps heavy duty for refrigerator /desert cooler complete all as specified and directed by Engr-in-charge.
51S&F in replacement of plug top 3 pin 15 amps heavy duty for water cooler, Voltage Stablizer & Air Conditioner complete all as specified and directed by Engr-in-charge.
52M&L for scraping and removing of old paint of desert cooler body (steel surface) and preparation of steel surfaces including necessary denting/welding/cutting etc and spray painting two coats with smoke grey synthetic enamel paint (Ist quality) over a coat of red oxide primer on outer surface and inner surface i.e. water tank and body, fan mounting blades shall be painted with a coat of anticorrosive black paint over a coat of red oxide primer complete for desert cooler of any size and capacity complete all as specified and directed.
53S&F wood wool pad set suitable for desert cooler for existing size complete all as specified and directed by Engr-in-charge.
54S&F in replacement sub main wiring with 2 run of 6 Sq mm single core copper conductor cable drawn through in rigid PVC conduit ISI marked with fitting and 6.0 Sq mm single core copper conductor cable for continues earth wire of 6 sqmm complete all as specified and directed by eng-in -charge.
55S&F in replacement of desert cooler body of size approx 660 x 660 x 900 mm with and including front grill and three side louver fabricated out of 22 gauge mild steel plain GI sheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge mild steel plain GI sheet including taking out and reinstallation complete with standard fittings such as PVC pipe for water, electric controls and switch, fan speed regulator, rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan, electric pump with new 3 core PVC insulated & PVC sheathed cables (min. 3 metre in length). External surfaces shall be spray painted with two coats of approvedsynthetic enamel paint over a coat of red oxide primer and internal surface of body, cooler pump and motor shall be painted with two coats of bituminous paint over a coat of red oxide primer complete all as specified and directed by the Engineer-in-Charge.
56Supply & Fix in replacement sheet metal enclosure with a two pin and earth plug socket complete including with 32 Amps MCB Single pole 240 Volt AC complete all as specified and a directed.
57M&L in replacement for MCB single pole 6-32 Amps, 240 V .
58M&L in replacement for MCB single pole & neutral 32 to 63 Amps, 240 V .
59M&L in replacement for MCB triple pole & neutral 63 Amps, 240 V
60Supply & fixing in replacement Complete Indoor unit with remote of Split AC capacity 1.5 Tonne any make complete all as specified & directed by the Engineer-in-Charge.
61Supply and fixing in replacement of outdoor unit capacity 1.5 ton with fan motor ,fan blade and suction and discharge L key valve and capillary for split type 1.5 TR AC of existing make and model complete all as specified and directed by Engr-in-charge.
62S&F in replacement PVC drain pipe of 15mm,ISI marked complete all as specified and direcetd by eng in charge.
63Supply and fixing in replacement of MS Stand as per OEM Recommendation and Placing of Outdour Unit on MS Stand of C Channel.
64Supply and fixing of automatic voltage stabilizer suitable for 1.5 Ton Air Conditioner, capacity not less than 4 kVA, operating on single phase 230V AC, 50 Hz supply, having input voltage range 130V–290V (or better) and output voltage regulation ±8% or better, complete with high voltage cut-off, low voltage cut-off, overload protection, time delay system, thermal overload protection, digital display indication and housed in powder coated metal enclosure, including all accessories and connections, complete as specified and directed by Engineer-in-Charge.
65Labour only for attending complaints of air force station Mandore area carrying out necessary repairs at site by replacing unserviceable spares or taking down carefully unserviceable Spare parts by disconnecting electrical connections, unsecrewing from position, to workshop for carry out necessary repairs or deposit unrepairable parts to E/M Store yard for safe coustody all as directed and specified.
66Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc.
67M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core,FRLSH PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly,PVC, casing caping , GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed for following : -
68One light point/exhaust fan point controlled by one switch or one ceiling fan point controlled by one switch & electronic type fan regulator.
69One light point controlled by two Nos 5 Amps switch two way
70One 3 pin 5 Amp switch & socket outlet on same board with other switches.
71One 3 pin 5 Amp switch & socket outlet on Independant board.
72One bell point controlled by one switch 5 Amps bell push.
73All same as per item ser No 67.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core,FRLSH, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board.
74All same as per item ser No 67.00 here-in-above but wiring using 4.0 sqmm multi-stranded copper conductor, FRLSH,single core, PVC insulated and unsheathed cable, including 4.0 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/Geysers.
75S&F Switch piano, flush type, single pole, one way,5/6 Amp.
76S&F Switch piano, flush type, single pole, one way, 16 Amp.
77S&F Socket outlet 2/3 pin, 2-in-1, 5/6 Amp, flush type.
78S&F Switch Socket combination outlet 6 pin, 6 Amp, flush type
79S&F Switch Socket combination outlet 6 pin,16 Amp, flush type
80S&F in repairs Ceiling rose surface bakelite 65x50mm three terminal.
81S&F in repairs Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or squre box using necessay screw & gutti complete all as specified.
82S&F Stepped type electronic fan regulator, switch size, flush type 230V AC.
83S&F electronic Bell Bul-Bul music, 230 volt, single phase.
84S&F bell push, type, 6 Amps, 2 Module
85Taking out existing unserviceable switch board plates any type, dismantling switches cafully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 6/8 inch x 10 inch MS box and brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper mulitstranded cable all as directed at site by Engineer-in-charge Note : New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items
86All as per item ser No 78.00 here-in-before but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 6/8 inch 4 inch MS box.
87All as per item ser No 78.00 here-in-before but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 4 inch x 4 inch MS box.
88S&F Wall Mounted decorative luminaire fitting suitable for LED lamp B-22 Base 9 watt light fitting including inbuild LED light driver connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
89Supply and fixing of flexible LED Strip Light, 12 Watt per metre, operating on 230V AC supply through suitable driver/adaptor, having minimum luminous efficacy of 100 lm/W, colour temperature Warm White/Cool White as specified, IP20/IP65 protection as required, complete with mounting accessories, connectors, driver, fixing arrangement and all necessary connections, complete as specified and directed by Engineer-in-Charge.
90S&F in replacement LED Recessed full it luminaire with glare free uniform illumination with longer life and less maintance wattages in 2 ft x 2 ft not less then 100 lumen /watt complete all as specified and as directed. temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete..
91S&F in replacement LED Stud Bulk Head 10 watt fixture perfect interior and exterier application within car parks, walkway, stairwells, carridoors, local authorities and housing accosiation as well as commercial building including connectioncomplete all as specified and directed by Engineer in Charge.
92Supply and fixing in repair of LED surface round shape lights fitting 1x 10 W, 220V,AC aluminium body decorative box type with driver, with three core flexible copper conductor cable of suitable size from ceiling rose complete.
93Supply and fixing in repair of LED lights fitting 1x 20W, 220V,AC aluminium body decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
94Supply and fixing in repair of LED lights fitting 1x 10 W, 220V,AC aluminium body decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
95S&F in repair Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr - in Charge complete all as per Havells Cat No: ENDURAPEARLSL25W or equivalent model approved makes.
96M&L for Sub main wiring as per IS, single core FRLSH PVC insulated flexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 4.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 4.0 Sq.mm for continuous earth wire in green color.
97M&L for Sub main wiring as per IS, single core FRLSH PVC insulated flexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 6.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green color.
98M&L for Sub main wiring as per IS, single core FRLSH PVC insulated flexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for four runs of 10.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 10.0 Sq.mm for continuous earth wire in green color.
99Supply and replace sheet metal enclosure distribution board for 415volts, 4 way horizontal type, single door, triple pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
100Supply and replace sheet metal enclosure distribution board for 415volts, 8 way horizontal type, single door, triple pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
101Supply and replace sheet metal enclosure distribution board for 230 volts, 12 way horizontal type, single door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
102M&L for MCB TPN/FP, 40 to 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
103Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
104Supply and fixing MCB SPN/DP (single pole and neutral) 40 to 63 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. Please Enable Macros to View BoQ information
105Supply and fixing MCB SPN/DP (single pole and neutral) 40 to 63 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56415418
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 01-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Day To Day Maintenace Of Internal Electrification, Light Fittings/Fixtures And Repair/Replacement Of Heating & Cooling Appliances At Af Stn Mandore Under Age E/M, Ge (Af) No 2 Jodhpur
Basic Detail
Tender No 8612/E8
Bidding Type Tender
Location
City Jodhpur
State Rajasthan
Key Dates
Publish Date 10 Jul 2026
Submission Date 01 Aug 2026
Open Date 03 Aug 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
008a4f88-a913-4158-9824-52fbbac85d97.html
BOQ_870946.xls
tenderdocument.pdf
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

008a4f88-a913-4158-9824-52fbbac85d97.html

xls

BOQ_870946.xls

pdf

tenderdocument.pdf

pdf

Tendernotice_1 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders