Tender For Construction And Installation Of Waste-To-Art Entrance Gateways At Various Locations In Jaipur With 5 Years Operation And Maintenance
Tender Value
5.36 Crore
Estimated cost
Bid Submission
30 Jul 2026
18 days left
EMD
10.73 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction And Installation Of Waste-To-Art Entrance Gateways At Various Locations In Jaipur With 5 Years Operation And Maintenance
BOQ
| Sl. No. | Item Description |
| 1 | Installation and Febrication of the Ghat Ki Ghuni Toll Plaza Gateway Armature structure to be made using the scrap/waste materials, CnD Waste and Ceramic tiles and glass product waste etc. Of Size not less then -125 feet X 12 feet X 20 feet. (The size of Structure may vary +- 2 feet in size as per design) Over the Prepared Foundation ISI marked Tubular Frame Structure of 100 mm and 150 mm dia structure members shall be installed. For Joining the Outer skin, purlins (Structure members of pipes and RHS, SHS pipes of not more then 75mm dia or size) shall be step-by-step assembled as per structure drawings. The material selection shall be procedded for selection and metal preperation, cutting, flattering, dismantelling and assembling of scrap material. further washing stages hot and cold chemical washing to remove greece, rust and dust. grinding rust removal. Artist shall create segments of design stage wise structuring and , Moulding work. the fabrication of all moulded and crafted sections and segments shall be casted and fabricated to join togather through welding works as per industry standard welding embalishment. Mounting structure with use of Machinery such as crane, JCB, Hydra for weight appropriate installation. Fabricating and finishing sculpture details Using selected segrigated scrap, ceramics and glass waste structure balancing and inspections as per the instructions of the structure engineer and artist in charge and the consultant. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing. The item including all material, Labour, Scaffolding and anything else which required to complete as per direction of Engineer-in-charge. For details reffer enclosed drawings. Cost of the complete Item includes cost of Repairs, Maintenance and operation of the property for the period of five years after actual date of completion |
| 2 | Installation and Febrication of the Dher Ki Dhani (Ganga Marg) New Jaipur Gateway Armature structure to be made using the scrap/waste materials, CnD Waste and Ceramic tiles and glass product waste etc. Of Size not less then -12 feet X 12 feet X 24 feet. (The size of Structure may vary +- 2 feet in size as per design) Over the Prepared Foundation ISI marked Tubular Frame Structure of 100 mm and 150 mm dia structure members shall be installed. For Joining the Outer skin, purlins (Structure members of pipes and RHS, SHS pipes of not more then 75mm dia or size) shall be step-by-step assembled as per structure drawings. The material selection shall be procedded for selection and metal preperation, cutting, flattering, dismantelling and assembling of scrap material. further washing stages hot and cold chemical washing to remove greece, rust and dust. grinding rust removal. Artist shall create segments of design stage wise structuring and , Moulding work. the fabrication of all moulded and crafted sections and segments shall be casted and fabricated to join togather through welding works as per industry standard welding embalishment. Mounting structure with use of Machinery such as crane, JCB, Hydra for weight appropriate installation. Fabricating and finishing sculpture details Using selected segrigated scrap, ceramics and glass waste structure balancing and inspections as per the instructions of the structure engineer and artist in charge and the consultant. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing. The item including all material, Labour, Scaffolding and anything else which required to complete as per direction of Engineer-in-charge. For details reffer enclosed drawings. Cost of the complete Item includes cost of Repairs, Maintenance and operation of the property for the period of five years after actual date of completion |
| 3 | Installation and Febrication of the Amer Kunda Mor Gateway Armature structure to be made using the scrap/waste materials, CnD Waste and Ceramic tiles and glass product waste etc. Of Size not less then -180 feet X 12 feet X 36 feet. (The size of Structure may vary +- 2 feet in size as per design) Over the Prepared Foundation ISI marked Tubular Frame Structure of 100 mm and 150 mm dia structure members shall be installed. For Joining the Outer skin, purlins (Structure members of pipes and RHS, SHS pipes of not more then 75mm dia or size) shall be step-by-step assembled as per structure drawings. The material selection shall be procedded for selection and metal preperation, cutting, flattering, dismantelling and assembling of scrap material. further washing stages hot and cold chemical washing to remove greece, rust and dust. grinding rust removal. Artist shall create segments of design stage wise structuring and , Moulding work. the fabrication of all moulded and crafted sections and segments shall be casted and fabricated to join togather through welding works as per industry standard welding embalishment. Mounting structure with use of Machinery such as crane, JCB, Hydra for weight appropriate installation. Fabricating and finishing sculpture details Using selected segrigated scrap, ceramics and glass waste structure balancing and inspections as per the instructions of the structure engineer and artist in charge and the consultant. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing. The item including all material, Labour, Scaffolding and anything else which required to complete as per direction of Engineer-in-charge. For details reffer enclosed drawings. Cost of the complete Item includes cost of Repairs, Maintenance and operation of the property for the period of five years after actual date of completion |
| 4 | Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr and lift up to 1.5 Mtr disposed soil to be levelled and neatly dressed : All kinds of soil |
| 5 | Granular Sub-Base with Close Graded Material (Table:- 400-1) Plant Mix Method Providing laying spreading and compacting specified graded sand, gravel (crushed stone) as per Table 400-1,400-2 or any other course material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversion complete.[MoRTH specification : Clause 401]. By mechanical means.For grading I material. |
| 6 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 7 | Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement) M-30, 60 mm thick to be used in non traffic areas like building premises, monument premises, land scapes, public gardens/ park, domestic drives, paths and patios, Embankment slopes, sand stabilization Area etc.( As per table 1 of IS 15658:2006 Category A Denated units to key into each other on four faces zigzag shape as per IRC SP 63:2004 |
| 8 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 9 | Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size. 50mmx50mmx3.15mm |
| 10 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 11 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 12 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786). Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 13 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 14 | Extra if square,rectangular hollow tubelar sections are used or grill made by flats only |
| 15 | Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks. Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 16 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 20mm thick |
| 17 | Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. |
| 18 | Supply of dry manure including loading unloading,transportation & stacking at site.Vermi compost |
| 19 | Supply of different varieties of palms in poly bags/earthen pot according to height growth and age of plant at site including loading unloading and transportation etc. complete. |
| 20 | Raffish palm 2 to 2.2 feet |
| 21 | Arica palm many branches 6 feet |
| 22 | Fox tale palm 8 feet |
| 23 | Fish tale palm 8 feet |
| 24 | Supply of different varieties of bougainvillea in ply bags/earthen pot according to height growth and age of plant at site including loading unloading and transportation etc. complete. Different varieties of bougainvillea 900mm |
| 25 | Ground Cover of various varieties Supply & plantation of Ground Covers including mortility replacement loading - unloading transportation and maintenance for 30 days after planting the plants |
| 26 | Pendanus in P.B(9”X11”) - 1’ |
| 27 | Ophiphogon japonicas 'variegata' |
| 28 | Rhoea spathacea |
| 29 | Russelia equiseliformis |
| 30 | Wedelia trilobata |
| 31 | Hedges of various varieties. Golden durantain P.B(5”X6”) - 6”-1’ |
| 32 | Diffrant varieties of Scented Plants.Madhukamini(Round Shaped dwarf variety)in P.B(9”X11”) -1’ |
| 33 | Ornamental Plants of different varieties |
| 34 | Ixora Chinesisin Pot (8” Pot’s) - 6”-1’ |
| 35 | Silver Eucain P.B(9”X11”) - 1’-2’ |
| 36 | Euphorbia Milii D.varietiesin P.B(12”X2”) - 1’-1½’ |
| 37 | Pulmeria Rubra 8'-10' height, Girth 20 to 25 cm at collar ht. multibranching in 25 x 25 poly bag Including loading unloading transportation. |
| 38 | Supply & Plantation of plants.Supply & Plantation of selected specimen plants including mortality replacement, loading - unloading transportation and maintenance for 30 days after planting the plants. |
| 39 | Phoenix roebilinii 3'-4' ht dia 4'-5' |
| 40 | Roystonea venezuelana 12'-15' |
| 41 | Washintonia filifera 5'-6' |
| 42 | Supply and plantation of Ornamental trees including mortility replacement loading - unloading transportation and maintenance for 30 days after planting the plants |
| 43 | Curesea spaciosa 8'-10' |
| 44 | Ficus king bush 4'-5' |
| 45 | Maintenance of parks Supply & laying of carpet grass (Selection No. 1) including levelling, cleaning, mixing of manure and one month maintenance up to first lawn mowing. |
| 46 | P & F 1.2 mm thick G. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1.2 mm thick M. S. Sheet boxes,300mm x 375mm x 75mm |
| 47 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.25 mm |
| 48 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 Mtr below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 49 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR 8 SWG tinned copper Wire |
| 50 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35Sqmm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.Single pole MCB (With B/C curve tripping Characteristics)6 A to 32 A rating |
| 51 | Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating |
| 52 | Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating |
| 53 | Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 35 Sqmm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.Four pole 30 mA sensitivity |
| 54 | 40A Rating |
| 55 | 63A Rating |
| 56 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.4 pole MCCB With Thermal Magnetic release.125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 57 | Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Spreaders upto 125A, 3 Pole MCCB |
| 58 | 4 pole MCCB With Microprocessor based release with adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection. |
| 59 | Upto 160 Amp , 50 kA |
| 60 | 400 Amp, 50kA |
| 61 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 62 | 1 x 1.5 Sqmm |
| 63 | 3 x 1.5 Sqmm |
| 64 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. |
| 65 | 25.0sqmm 3.5core |
| 66 | 16.0Sqmm 4 Core |
| 67 | 10.0Sqmm 4 Core |
| 68 | 6Sqmm 4 Core |
| 69 | 70.0Sqmm 3.5 Core |
| 70 | 4.0 Sqmm 4 Core |
| 71 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Metal door (Three phase) IK-09 and IP-43 with Metal end box, 12 Way |
| 72 | Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 73 | 10-12 Module |
| 74 | 16/18 module |
| 75 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 76 | High Power LED Flood Light Minimum lumen output 8700 lm |
| 77 | High Power LED Flood Light Minimum lumen output 12400 lm |
| 78 | Providing & Fixing of IP20, 1100-1200 mm x 50-60 mm x 70-85 mm size Suspended mounting Mid power SMD type LED linear Light fixture made from Extruded Aluminium housing, PMMI diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of = 100 lm/Watt ,THD < 10 % , p.f.=0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 79 | Minimum lumen output 2000 lm |
| 80 | Minimum lumen output 3000 lm |
| 81 | P & Fixing Powder coated CRCA sheet enclosures on existing angle iron frame by means of nuts and bolts and making holes , Din rail etc. as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 2.0mm thick |
| 82 | Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 83 | Three phase Ammeter with Inbuilt Selector Switch |
| 84 | Three phase Voltmeter with Inbuilt Selector Switch |
| 85 | Three phase KWH Meter |
| 86 | Providing & Fixing of din rail mounting LED Indicating Lights with following description and configuration in existing distribution board / sheet including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Red-Yellow -Blue Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender