Educational and Research Institute Boards / Undertakings / PSU Closing in 20 days TDR #56414902

Tender For Electification Work In Sub Store Hall (Surface Pvc Conduit Wiring With Modular Accessories)

Issued by Boards / Undertakings / PSU · Udaipur, Rajasthan
Tender Value
5.80 Lakhs
Estimated cost
Bid Submission
31 Jul 2026
20 days left
EMD
11600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Electification Work In Sub Store Hall (Surface Pvc Conduit Wiring With Modular Accessories) , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Class 2 Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Class 2 Copper Earth Conductor 1.1 Kv Grade (Is:694) On Surface Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal/Surface Mounted Upvc Molded Modular Box, 6 A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr.) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Class 2 Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Class 2 Copper Earth Conductor 1.1 Kv Grade(Is:694) On Surface Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal/Surface Mounted Upvc Molded Modular Box, 6 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. , On Board , S&F Following Sizes (Dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit Along With Isi Marked (Is:3419-1988) Accessories As Required On Surface Including Heavy Duty Saddles With Base At Spacing Of 0.60 Mtr. Etc As Required. , 20 Mm , 25 Mm , Supplying And Laying Fr Pvc Insulated & Unsheathed Flexible Copper Conductor Of Following Nominal Sizes With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. , 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanism , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 25 Sq.Mm., Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating, 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. , Single Pole Mcb (With B / C Curve Tripping Characteristics) 6 A To 32 A Rating , Double Pole Mcb (With B / C Curve Tripping Characteristics) 6 A To 32 A Rating , Four Pole Mcb (With B / C Curve Tripping Characteristics) 50/63 A Rating , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Enclosure Made Out From Galvanized Steel / Crca Sheet, Powder Coated Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Complete With Din Rail Making Internal Db Terminations With Copper Lugs, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. , Suitable For Two / Three / Four Module For Mcb , Providing & Fixing Of Modular Type 100W Step Fan Regulator Duly Isi Marked (Is 11037) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Virgin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including Making Connections, Testing Etc As Required. , 5 Step Fan Regulator 2 Module , Supplying And Fixing Of Power Plug Point With Modular Accessories On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :38) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door (Metal / Glazed / Acrylic) Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet, Powder Coated Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Complete With 100 Amp. Insulated Copper Bus Bar/Shorting Link , Brass Neutral Link With Shrouds, Brass Earth Link , Door Earthing Arrangement, Color Coded Interconnecting Wire Set Of Minimum 10.0 Sqmm Size And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. , Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box 6 Way (8 Incomer + 18 Outgoing) , Providing & Laying Xlpe Insulated & P.V.C. Sheathed Armoured Aluminium Cable Confirming To Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Commissioning Etc. As Required Of Following Size. , 25.0 Sq. Mm 3.5 Core , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, Heavy Duty Weather Proof Poly-Propylene Earth Inspection Chamber As Per Requirement Of Is/Iec 62305 And Tested As Per Iec 62561-5 With Lockable Jam Free Lid Suitable For Safe Working Load 60 Kn Of Round / Square Size 250 Mm, And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required. , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity 95% Thimble Etc. As Required. , 8 Swg G.I. ( Hot Dipped ) Wire , Supply , Installation, Testing And Commissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Of Both Compressor And Printed Circuit Board (Pcb). , Cooling Capacity 6200-6350 Watt, Iseer Not Less Then 3.8 , Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Ensure That The Cable Is Tested For Complaince, Either Through Their In House Laboratory Accrediated By Nabl Or By Any Govt. Laboratory Accrediated By Nabl And The Laboratorys Scope Of Accrediation Should Cover The Requirements And Testing Procedure As Per Is:10810. , Un Armoured 4 Core X 2.5 Sq.Mm , Supply, Installation, Testing And Commissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 With 7 Mil Glass Cloth And 3 Coats Of Anti Uv Paint (On Area Which Is Exposed To Weather) Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. , 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation - 13 Mm Thick) , 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation - 13 Mm Thick) , Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. , 20 Mm , Supply, Fixing And Testing Of Following Capacity Is:8448 Marked Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. , 5 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. , Supply Installation Testing and Commissioning of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminium Housing With In Built Driver , System Lumen Efficacy ≥ 110 Lm/Watt Output Only At Cw (5700K To 6500K) , Internal Surge Protection Of 4.0 Kv With Short & Open Circuit Protection ,Thd 10% , P. F.≥0.95, Cri 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) As Required. , 1170Mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm , Supply Installation Testing and Commissioning of Ip-20 Led Recessed / Surface Mounted, Round / Square Backlit & Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Compliance 4.0 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection Input 320Vac-48 Hr Protection, Input 350Vac-2 Hr Protection), Having Efficiency 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt,At Cw (5700K To 6500K) , Thd 10 % , Pf.≥0.95, Cri 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) As Required. , Surface Mounting (With Extruded Alumn. Housing ) Minimum Lumen Output 1950 Lm , Providing & Fixing Of Bee Star Rated Copper Wounded With Class Of Insulation F, Double Ball Bearing Capacitor Start, Aluminium Body & Aluminium Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 With Down Rod Up To 30 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin, Shackle Kit With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor And Making Connection Testing Etc. As Required. , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core 1.5 Sq.Mm Copper Conductor ,Making Connections, Testing Etc. As Required. , 300 Mm Sweep Minimum Air Delivery 1600 Cum / Hour

BOQ

Name of Work:- Electification work in sub store hall (Surface PVC Conduit Wiring with Modular accessories)
Sl. No. Item Description
1Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal/Surface mounted UPVC molded modular box, 6 A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required.
2Short point (up to 3 mtr.)
3Medium point (up to 6 mtr.)
4Long point (up to 10 mtr.)
5Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.
6On board
7S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc as required.
820 mm
925 mm
10Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.
112 x 2.5 sq. mm. + 1x1.5sqmm
122 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
13Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required.
14Single pole MCB (With B / C curve tripping characteristics) 6 A to 32 A rating
15Double pole MCB (With B / C curve tripping characteristics) 6 A to 32 A rating
16Four pole MCB (With B / C curve tripping characteristics) 50/63 A rating
17Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required.
18Suitable for Two / Three / Four module for MCB
19Providing & Fixing of modular type 100W Step Fan regulator duly ISI marked (IS 11037) with CM/L no. printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including making connections, testing etc as required.
205 step fan regulator 2 Module
21Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required.
22Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required.
23Metal door (Three phase) IK-09 and IP-43 with Metal end box6 Way (8 incomer + 18 Outgoing)
24Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.
2525.0 Sq. mm3.5 core
26Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
27Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required.
288 SWG G.I. ( Hot Dipped ) Wire
29Supply , Installation, Testing and Commissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year Original Equipment Manufacturer (OEM) warranty of both compressor and Printed Circuit Board (PCB).
30Cooling capacity 6200-6350 Watt, ISEER not less then 3.8
31Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM must ensure that the cable is tested for complaince, either through their in house laboratory accrediated by NABL or by any Govt. laboratory accrediated by NABL and the laboratory's scope of accrediation should cover the requirements and testing procedure as per IS:10810.
32Un Armoured4 core x 2.5 Sq.mm
33Supply, installation, testing and commissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 with 7 mil Glass Cloth and 3 coats of anti UV paint (on area which is exposed to weather) including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes.
3412.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
356.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
36Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes.
3720 mm
38Supply, Fixing and testing of following capacity IS:8448 marked wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect.
395 kVA
40Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia
4150 mm dia per running inch length
42Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge.
43SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
441170mm(+/-10%) LED batten with min. lumen output 2200 lm
45SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
46Surface Mounting (with extruded alumn. Housing )Minimum lumen output 1950 lm
47Providing & Fixing of BEE Star rated copper wounded with class of Insulation 'F', double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required.
481200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 )
49Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core 1.5 Sq.mm copper conductor ,making connections, testing etc. as required.
50300 mm sweep Minimum air delivery 1600 Cum / hour Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56414902
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 5.80 Lakhs
LAST DATE 31-07-2026
Authority
Authority Name Rabindranath Tagore Medical College
Work Description Tender for Electification Work In Sub Store Hall (Surface Pvc Conduit Wiring With Modular Accessories) , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Class 2 Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Class 2 Copper Earth Conductor 1.1 Kv Grade (Is:694) On Surface Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal/Surface Mounted Upvc Molded Modular Box, 6 A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr.) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Class 2 Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Class 2 Copper Earth Conductor 1.1 Kv Grade(Is:694) On Surface Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal/Surface Mounted Upvc Molded Modular Box, 6 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. , On Board , S&F Following Sizes (Dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit Along With Isi Marked (Is:3419-1988) Accessories As Required On Surface Including Heavy Duty Saddles With Base At Spacing Of 0.60 Mtr. Etc As Required. , 20 Mm , 25 Mm , Supplying And Laying Fr Pvc Insulated & Unsheathed Flexible Copper Conductor Of Following Nominal Sizes With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. , 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanism , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 25 Sq.Mm., Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating, 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. , Single Pole Mcb (With B / C Curve Tripping Characteristics) 6 A To 32 A Rating , Double Pole Mcb (With B / C Curve Tripping Characteristics) 6 A To 32 A Rating , Four Pole Mcb (With B / C Curve Tripping Characteristics) 50/63 A Rating , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Enclosure Made Out From Galvanized Steel / Crca Sheet, Powder Coated Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Complete With Din Rail Making Internal Db Terminations With Copper Lugs, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. , Suitable For Two / Three / Four Module For Mcb , Providing & Fixing Of Modular Type 100W Step Fan Regulator Duly Isi Marked (Is 11037) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Virgin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including Making Connections, Testing Etc As Required. , 5 Step Fan Regulator 2 Module , Supplying And Fixing Of Power Plug Point With Modular Accessories On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :38) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door (Metal / Glazed / Acrylic) Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet, Powder Coated Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Complete With 100 Amp. Insulated Copper Bus Bar/Shorting Link , Brass Neutral Link With Shrouds, Brass Earth Link , Door Earthing Arrangement, Color Coded Interconnecting Wire Set Of Minimum 10.0 Sqmm Size And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. , Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box 6 Way (8 Incomer + 18 Outgoing) , Providing & Laying Xlpe Insulated & P.V.C. Sheathed Armoured Aluminium Cable Confirming To Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Commissioning Etc. As Required Of Following Size. , 25.0 Sq. Mm 3.5 Core , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, Heavy Duty Weather Proof Poly-Propylene Earth Inspection Chamber As Per Requirement Of Is/Iec 62305 And Tested As Per Iec 62561-5 With Lockable Jam Free Lid Suitable For Safe Working Load 60 Kn Of Round / Square Size 250 Mm, And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required. , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity 95% Thimble Etc. As Required. , 8 Swg G.I. ( Hot Dipped ) Wire , Supply , Installation, Testing And Commissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Of Both Compressor And Printed Circuit Board (Pcb). , Cooling Capacity 6200-6350 Watt, Iseer Not Less Then 3.8 , Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Ensure That The Cable Is Tested For Complaince, Either Through Their In House Laboratory Accrediated By Nabl Or By Any Govt. Laboratory Accrediated By Nabl And The Laboratorys Scope Of Accrediation Should Cover The Requirements And Testing Procedure As Per Is:10810. , Un Armoured 4 Core X 2.5 Sq.Mm , Supply, Installation, Testing And Commissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 With 7 Mil Glass Cloth And 3 Coats Of Anti Uv Paint (On Area Which Is Exposed To Weather) Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. , 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation - 13 Mm Thick) , 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation - 13 Mm Thick) , Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. , 20 Mm , Supply, Fixing And Testing Of Following Capacity Is:8448 Marked Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. , 5 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. , Supply Installation Testing and Commissioning of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminium Housing With In Built Driver , System Lumen Efficacy ≥ 110 Lm/Watt Output Only At Cw (5700K To 6500K) , Internal Surge Protection Of 4.0 Kv With Short & Open Circuit Protection ,Thd 10% , P. F.≥0.95, Cri 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) As Required. , 1170Mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm , Supply Installation Testing and Commissioning of Ip-20 Led Recessed / Surface Mounted, Round / Square Backlit & Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Compliance 4.0 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection Input 320Vac-48 Hr Protection, Input 350Vac-2 Hr Protection), Having Efficiency 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt,At Cw (5700K To 6500K) , Thd 10 % , Pf.≥0.95, Cri 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) As Required. , Surface Mounting (With Extruded Alumn. Housing ) Minimum Lumen Output 1950 Lm , Providing & Fixing Of Bee Star Rated Copper Wounded With Class Of Insulation F, Double Ball Bearing Capacitor Start, Aluminium Body & Aluminium Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 With Down Rod Up To 30 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin, Shackle Kit With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor And Making Connection Testing Etc. As Required. , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core 1.5 Sq.Mm Copper Conductor ,Making Connections, Testing Etc. As Required. , 300 Mm Sweep Minimum Air Delivery 1600 Cum / Hour
Basic Detail
Tender No 54
Bidding Type Tender
Location
City Udaipur
State Rajasthan
Key Dates
Publish Date 10 Jul 2026
Submission Date 31 Jul 2026
Open Date 01 Aug 2026
Finance
Tender Value 5.80 Lakhs
Tender Fee 500
EMD 11600
Exemption Available
Document List
55213acf-8858-4529-ad1b-7cee58414c63.html
BOQ_1021708.xls
substore.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

55213acf-8858-4529-ad1b-7cee58414c63.html

xls

BOQ_1021708.xls

pdf

substore.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders