Power Government Departments Closing in 4 days TDR #56414257

Tender For Annual Electrical maintenance and repair Work Of New & Old M.D. Office, Inspection House, Customer Care Center, C.Z.E. Office, E.T.I, Badminton Hall And Officers/Employee Residences, At Vidyut Nagar, Bhikharipur, Varanasi.

Issued by Government Departments · Varanasi, Uttar Pradesh
Tender Value
21.44 Lakhs
Estimated cost
Bid Submission
16 Jul 2026
4 days left
EMD
43000
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Electrical maintenance and repair Work Of New & Old M.D. Office, Inspection House, Customer Care Center, C.Z.E. Office, E.T.I, Badminton Hall And Officers/Employee Residences, At Vidyut Nagar, Bhikharipur, Varanasi.

BOQ

Name of Work:- ANNUAL ELECTRICAL M&R WORK OF NEW & OLD M.D. OFFICE, INSPECTION HOUSE, CUSTOMER CARE CENTER, C.Z.E. OFFICE, E.T.I, BADMINTON HALL AND OFFICERS/EMPLOYEE RESIDENCES, AT VIDYUT NAGAR, BHIKHARIPUR, VARANASI.
Sl. No. Item Description
1Supply of 6Amp 1 way Piano type switch make Havells,Anchor etc. or its equivalent as directed by E/I.
2Supply of 16Amp 1 way Piano type switch make Havells,Anchor etc. or its equivalent as directed by E/I.
3Supply of 6Amp 2 way piano type switch make Havells,Anchor etc. or its equivalent as directed by E/I.
4Supply of 6Amp Bell Push switch make Havells,Anchor etc. or its equivalent as directed by E/I.
5Supply of 6Amp 2-in-1 piano type socket make Havells,Anchor etc. or its equivalent as directed by E/I
6Supply of 16Amp 2-in-1 piano type socket make Havells,Anchor etc. or its equivalent as directed by E/I
7Supply of 100w Fan Regulator(240V-50Hz)Rotary step make Havells,Anchor etc. or its equivalent as directed by E/I
8Supply of 6Amp 2-in-1 switch socket combined with box make Havells,Anchor etc. or its equivalent as directed by E/I
9Supply of 6Amp 1 way bed switch make Havells,Anchor etc. or its equivalent as directed by E/I
10Supply of Hanging Bell push switch make Havells,Anchor etc. or its equivalent as directed by E/I
11Supply of 6Amp surface Bell Push switch make Havells,Anchor etc. or its equivalent as directed by E/I
12Supply of 6Amp pilot 3 plate ceiling rose make Havells,Anchor etc. or its equivalent as directed by E/I
13Supply of 6Amp Batten holder make Havells,Anchor etc. or its equivalent as directed by E/I
14Supply of 2 pole change over switch pilot make Havells,Anchor etc. or its equivalent as directed by E/I
1516Amp 415V
1632Amp 415V
17Supply of 3 pole change over switch pilot make Havells,Anchor etc. or its equivalent as directed by E/I
1816Amp 415V
1932Amp 415V
2063Amp 415V
21Supply of 4 pole change over switch pilot make Havells,Anchor etc. or its equivalent as directed by E/I
2232Amp 415V
2363Amp 415V
24100Amp 415V T.P
25Supply of Porcelain Fuse unit (240V-50Hz)pilot make Havells,Anchor etc. or its equivalent as directed by E/I
2616Amp 415V
2732Amp 415V
2863Amp 415V
29100Amp 415V
30200Amp 415V
31Supply of Surface mounting box for switches make Havells,Anchor etc. or its equivalent as directed by E/I
321 Gang Box
332 Gang Box
343 Gang Box
354 Gang Box
365 Gang Box
376 Gang Box
387 Gang Box
39Supply of Domestic Surface mounting box for switches make Havells,Anchor etc. or its equivalent as directed by E/I
40Surface Box-4x4
41Surface Box-4x7
42Surface Box-6x8
43Surface Box-8x10
44Surface Box-10x12
45Supply of 20Amp 1 way piano type switch make Anchor,Havells etc. or its equivalent as directed by E/I.
46Supply of 20Amp 2 way piano type switch make Anchor,Havells etc. or its equivalent as directed by E/I.
47Supply of 20Amp piano type Socket make Anchor,Havells etc. or its equivalent as directed by E/I.
48Supply of 20Amp 1 way piano type switch with box make Anchor,Havells etc. or its equivalent as directed by E/I.
49Supply of 20Amp piano type Socket with box make Anchor,Havells etc. or its equivalent as directed by E/I
50Supply of 16Amp 3 pin piano type Socket make Anchor,Havells etc. or its equivalent as directed by E/I.
51Supply of 10Amp 1way modular switch make Anchor,Havells etc. or its equivalent as directed by E/I.
52Supply of 10Amp 2way modular switch make Anchor,Havells etc. or its equivalent as directed by E/I.
53Supply of 10Amp Bell push modular switch make Anchor,Havells etc. or its equivalent as directed by E/I
54Supply of 20Amp 1way modular switch make Anchor,Havells etc. or its equivalent as directed by E/I.
55Supply of 20Amp 2way modular switch make Anchor,Havells etc. or its equivalent as directed by E/I.
56Supply of 20Amp multi socket (modular)make Anchor,Havells etc. or its equivalent as directed by E/I.
57Supply of 6/10/13Amp combined modular socket for all pins make Anchor,Havells etc. or its equivalent as directed by E/I.
58Supply of 100w step high speed modular fan regulator(240v-50Hz) make Anchor,Havells etc. or its equivalent as directed by E/I.
59Supply of 6 to 32Amp SP MCB Coral make Ancho,Havells etc or its equivalent as directed by E/I.
60Supply of Call Bell make Anchor,Havells etc. or its equivalent as directed by E/I.
61Supply of wireless call Bell make Anchor,Havells etc. or its equivalent as directed by E/I.
62Supply of 4 way extension board make Anchor,Havells etc. or its equivalent as directed by E/I.
63Supply of 6Amp 3pin supar top make Anchor,Havells etc. or its equivalent as directed by E/I.
64Supply of 16Amp 3pin supar top make Anchor,Havells etc. or its equivalent as directed by E/I.
65S/Replacing of broken bearing of ceiling fan including all labour materials and T&P etc. required for proper completion of the work.
66Supply of casing patti including bend, Tee, Socket with Pench and Gully etc. with required for proper completion of work as directed by E/I.
67Supply of 0.75 Sqm gauge copper wire make havells, Anchors etc its equivalent make of approved quality as directed by E/I.
68Supply of 1.00 Sqm gauge copper wire make havells, Anchors etc its equivalent make of approved quality as directed by E/I.
69Supply of 1.5 Sqm gauge copper wire make havells, Anchors etc its equivalent make of approved quality as directed by E/I.
70Supply of 2.5 Sqm gauge copper wire make havells, Anchors etc its equivalent make of approved quality as directed by E/I.
71Supply of 4 Sqm gauge copper wire make havells, Anchors etc its equivalent make of approved quality as directed by E/I.
72Supply of 6 Sqm gauge copper wire make havells, Anchors etc its equivalent make of approved quality as directed by E/I.
73Supply of 10 Sqm gauge copper wire make havells, Anchors etc its equivalent make of approved quality as directed by E/I.
74Rewinding of burnt ceiling fan with approved copper wire including cost of all materials, labour and T&P etc. complete (Burnt wire will not be taken back.)
75Greasing of ceiling fan after cleaning the bearing and shaft with oil / petrol and its testing.
76Supply of 40Amp S.P. Isolator make Anchor,Havells etc. or its equivalent as directed by E/I.
77Supply and replacing of burnt and damaged condenser of ceiling fan of approved quality including cost of all materials, labour and T&P etc. complete.
78Supply of 40Amp D.P. Isolator make Anchor,Havells etc. or its equivalent as directed by E/I.
79Supply of 40Amp T.P. Isolator make Anchor,Havells etc. or its equivalent as directed by E/I.
80Supply of 63Amp S.P. Isolator make Anchor,Havells etc. or its equivalent as directed by E/I.
81Supply of 63Amp D.P. Isolator make Anchor,Havells etc. or its equivalent as directed by E/I.
82Supply of 63Amp T.P. Isolator make Anchor,Havells etc. or its equivalent as directed by E/I.
83Supply of 40Amp 4 pole Isolator make Anchor,Havells etc. or its equivalent as directed by E/I.
84Supply of 63Amp 4 pole Isolator make Anchor,Havells etc. or its equivalent as directed by E/I.
85Supply of 100Amp 4 pole Isolator make Anchor,Havells etc. or its equivalent as directed by E/I.
86Supply of 4 way MCB Box with metal door make Anchor,Havells etc. or its equivalent as directed by E/I.
87Supply of 8 way MCB Box with metal door make Anchor,Havells etc. or its equivalent as directed by E/I.
88Supply of 12 way MCB Box with metal door make Anchor,Havells etc. or its equivalent as directed by E/I.
89Supply of 18 watt LED Tube Light make Philips, Syska, Bajaj etc or its equivalent as directed by E/I.
90Supply of 7 watt LED Bulb make Philips, Syska, Bajaj etc or its equivalent as directed by E/I.
91Supply of 9 watt LED Bulb make Philips, Syska, Bajaj etc or its equivalent as directed by E/I.
92Supply of 12 watt LED Bulb make Philips, Syska, Bajaj etc or its equivalent as directed by E/I.
93Supply of 15 watt LED Bulb make Philips, Syska, Bajaj etc or its equivalent as directed by E/I.
94Supply of High Speed Ceiling Fan (1200mm Sweep) Make Usha, Havells etc or its equivalent as directed by E/I.
95Supply of 9 inch Exhaust Fan Make Usha, Havells etc or its equivalent as directed by E/I.
96Supply of 12 inch Exhaust Fan Make Usha, Havells etc or its equivalent as directed by E/I.
97Supply of 15inch Exhaust Fan Make Usha, Havells etc or its equivalent as directed by E/I.
98Supply of 18 inch Exhaust Fan Make Usha, Havells etc or its equivalent as directed by E/I.
99Supply of wall Fan Make Usha, Havells etc or its equivalent as directed by E/I.
100Supply of 40 watt electronics copper choke make havells, Anchors etc its equivalent as directed by E/I.
101Supply T.V. setup box stand of superior quality as directed by E/I.
102Supply of 6 sqmm Aluminium cable make make havells, Anchors etc or its equivalent as directed by E/I.
103Supply of 4 sqmm Aluminium cable make make havells, Anchors etc or its equivalent as directed by E/I.
104Supply of 36 watt LED (2'x2') square Light make philips, Syska, Bajaj etc or its equivalent as directed by E/I.
105Supply of 15 watt LED square / Circular Light make philips, Syska, Bajaj etc or its equivalent as directed by E/I.
106Supply of 12 watt LED square / Circular Light make philips, Syska, Bajaj etc or its equivalent as directed by E/I.
107Supply of 18 watt LED square / Circular Light make philips, Syska, Bajaj etc or its equivalent as directed by E/I.
108Supply of 6 watt LED square / Circular Light make philips, Syska, Bajaj etc or its equivalent as directed by E/I.
109Supply of 18 watt PL rod make Philips, Syska, Bajaj etc or its equivalent as directed by E/I.
110Supply of 40 watt tube rod make Philips, Syska, Bajaj etc or its equivalent as directed by E/I.
111Add for light/fan points with modular type switch in place of piano type switch.
112Add for 2 way light point with modular switches in place of piano type switches.
113Add for plug point with modular switch & socket in place on piano type switch & socket.
114Add for HPMV/Exhaust fan point with modular type switch in place of piano type switch.
115Add for call bell point with modular type bell push in place of piano type bell push.
116Add for Invertor Wiring in wiring point for light /Fan/Plug with 1.5 mm Wire.
117Supply and Wiring of submains with two nos. of 2.5 sq.mm. PVC insulated 1100v grade single core aluminium conductor cable in existing steel conduit complete with supply of all materials, labour & T&P required for proper completion of the work as directed by E/I.
118Same as in intm no 92 but with 2 nos. 4 sq.mm. PVC insulated cable.
119Same as in intm no.92 but with 2 nos. 6 sq.mm. PVC insulated cable.
120Same as in intm no.92 but with 2 nos. 10 sq.mm. PVC insulated cable.
121Same as in intm no.92 but with 2 nos. 16 sq.mm. PVC insulated cable.
122S&F of 32 Amp. Double pole change over switch on 25mmx25mmx3mm angle iron frame, including the cost of labour T&P, painting and other material required for proper completion of the work as per direction and satisfaction of E/I.
123S&F of 32 Amp for four pole change over switch on 25mmx25mmx3mm angle iron frame, including the cost of labour T&P, painting and other material required for proper completion of the work as per direction and satisfaction of E/I.
124S&F of 16 Amp. Four pole change over switch on 25mmx25mmx3mm angle iron frame, including the cost of labour T&P, painting and other material required for proper completion of the work as per direction and satisfaction of E/I.
125S&F of 63 Amp for four pole change over switch on 40mmx40mmx6mm angle iron frame, including the cost of labour T&P, painting and other material required for proper completion of the work as per direction and satisfaction of E/I.
126S&F of 100 Amp for four pole change over switch on 40mmx40mmx6mm angle iron frame, including the cost of labour T&P, painting and other material required for proper completion of the work as per direction and satisfaction of E/I.
127S&F of 200 Amp for four pole change over switch on 50mmx50mmx6mm angle iron frame, including the cost of labour T&P, painting and other material required for proper completion of the work as per direction and satisfaction of E/I.
128Supply and fixing of water tight oblong bulkhead fitting of approved make complete with prismatic glass holder, rubber gasket, G.I. Guard etc. complete in all respect.
129S&F of 6Amp to 32 Amp MCB make Anchor,Havells etc. or its equivalent including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
130S&F of 40 Amp. S.P. Isolator make Anchor,Havells etc. or its equivalent including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
131S&F of 63 Amp. S.P. Isolator make Anchor,Havells etc. or its equivalent including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
132S&F of 40 Amp. D.P. Isolator make Anchor,Havells etc. or its equivalent including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
133S&F of 63 Amp. D.P. Isolator make Anchor,Havells etc. or its equivalent including all labour,material,T&P etc. required for proper completion of work as directed by E/I.as directed by E/I.
134S&F of 40 Amp. T.P. Isolator make Anchor,Havells etc. or its equivalent including all labour,material,T&P etc. required for proper completion of work as directed by E/I.as directed by E/I.
135S&F of 63 Amp. T.P. Isolator make Anchor,Havells etc. or its equivalent including all labour,material,T&P etc. required for proper completion of work as directed by E/I.as directed by E/I.
136S&F of 40 Amp. 4 pole. Isolator make Anchor,Havells etc. or its equivalent including all labour,material,T&P etc. required for proper completion of work as directed by E/I.as directed by E/I.
137S&F of 63 Amp. 4 pole. Isolator make Anchor,Havells etc. or its equivalent including all labour,material,T&P etc. required for proper completion of work as directed by E/I.as directed by E/I.
138S&F of 100 Amp. 4 pole. Isolator make Anchor,Havells etc. or its equivalent including all labour,material,T&P etc. required for proper completion of work as directed by E/I.as directed by E/I.
139S&F of 100 Amp. 3 pole. Isolator make Anchor,Havells etc. or its equivalent including all labour,material,T&P etc. required for proper completion of work as directed by E/I.as directed by E/I.
140S&F surface /flush mounting 4 ways SPN distribution boared with additional metal door without MCB complete in all respect, as directed by E/I.
141S&F surface /flush mounting 8ways SPN distribution boared with additional metal door without MCB complete in all respect, as directed by E/I.
142S&F surface /flush mounting 12ways SPN distribution boared with additional metal door without MCB complete in all respect, as directed by E/I.
143Supply and fixing of call bell of approved make on polished MDFEG /Teak ply board including making connections etc. Complete in all respect.
144Supply and fixing of buzzer on polished on MDFEG /Teak ply board including making connections etc. Complete in all respect.
145Supply and fixing of 2 ways bell indicator on MDFEG /Teak ply board including making connections etc. Complete in all respect.
146Supply and fixing danger boared fabricated from 10 gauge M.S. sheet as per I.E. Rulers.
147Making hole in the wall for exhaust fan and finishing properly complete in all respect.
148Supply and fixing of 16 gauge M.S. drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect.
149Supply and fixing of 16 SWG M.S. drum with luvers duly painted inclduding making hole in the wall for exhaust fran and finishing properly complete in all respcet.
150Supply and fixing of fan hook fabricated from M.S. rod for ceiling fan each.
151Supply and fixing cross clamp of required size fabricated from 50mmx12mm M.S. falt complete with fan hook including painting etc. complete in all respect.
152Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A /250v flush type universal socket in suitable M.S. box of 175mmx110mmx50mm thick fixed with brass machine screw and cup waher.
153S&F of power plug with 20 Amp/250 V flush type modular switch and 5 pin 20A/250 volt flush type universal modular socket switch on concealed M.S. box including supply of all materials, labour and T&P etc. required for proper completion of work.
154S&F of electronic fan regulator 120-280V ISI marked on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of E/I of work.
155Supply and fixing of electronic fan regulator ( Modular) 120-280V, ISI marked, on the existing switch board including making connection required material, labour T&P etc. for proper completion of work to the satisfaction of E/I. of work.
156Supply and fixing of AC Box make Havells, Anchors etc. or its equivalent including all labour, material, T&P etc. required for proper completion of work as directed by E/I.
157Providing two no. of electrician with Licence & Kit for electrical maintenance work at M.D. office/ Inspection House/Call centre/CZE Office/M.D. residence etc.required for proper completion of work as directed by E/I.
158Providing one no. of Helper for electrical maintenance work at M.D. office/ Inspection House/Call centre/CZE Office/M.D. residence etc.required for proper completion of work as directed by E/I.
159Proper servicing and overhauling of 1.50/2.0 Ton capacity old and used Voltas or its equivalent Split Air conditioner including disassembling reassembling alter replacement or repair of defective parts, oiling and greasing, trail testing etc. including all labour,material,T&P etc. required for proper completion of work as directed by E/I.(but excluding cost of repair and replacement of defective parts, which shall be paid separatly).
160Proper servicing and overhauling of 1.50/2.0 Ton capacity old and used Voltas or its equivalent Window Air conditioner including disassembling reassembling alter replacement or repair of defective parts, oiling and greasing, trail testing etc. including all labour,material,T&P etc. required for proper completion of work as directed by E/I.(but excluding cost of repair and replacement of defective parts, which shall be paid separatly).
161Proper Gas charging in 1.5 Ton Window Air conditioner including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
162Proper Gas charging in 1.5 Ton split Air conditioner including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
163Supply and Replacing of ruunning capacity or condensing lade of 1.50/2.0T capacity Window/Split A.C. including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
164Supply and Replacing of running capacity or condensing blade of 1.50/2.0T capacity Window/Split A.C.including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
165Supply and Replacing of fan capacitor or air filter for 1.50/2.0T capacity Window/Split A.C.including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
166Supply and Replacing of starting capacity of 1.50/2.0T capacity Window/Split A.C.including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
167Supply and Replacing of thermostate of 1.50/2.0T capacity Window/Split A.C.including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
168Supply and Replacing of selector switch for 1.50/2.0T capacity Window/Split A.C.including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
169Supply and Replacing of strainer filter of 1.50/2.0T capacity Window/Split A.C.including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
170Rewinding of starter of 1.50/2.0T capacity Window/Split A.C. including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
171Replacement of damaged compressor of old used 1.50 tonne A.C. make Hitachi or its equivalent including gas charging, testing etc. all complete.including all labour,material,T&P etc. required for proper completion of work as directed by E/I.( Old and unserviceable and damaged compressor shall be contractor's property).
172S/R of Window A.C. Grill for 1.5/2.0T Window of approved make including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
173Proper Gas charging in 2.0Ton Window A.C. including all labour, materials & T&P etc. required for proper completion of work as directed by E/I.
174Proper Gas charging in 2.0Ton split A.C. including all labour, materials & T&P etc. required for proper completion of work as directed by E/I.
175Replacement of damaged compressor of old used 2.0 Ton A.C. make Hitachi or its equivalent including gas charging, testing etc. all complete.including all labour,material,T&P etc. required for proper completion of work as directed by E/I.( Old and unserviceable and damaged compressor shall be contractor's property).
176Rewinding and repair of burnt old and used 4 K.V.A. Voltas or equivalent make stabilizer for A.C. including cost of replacement of burnt wire and other minor parts including cost of all labour, ,materials,T&P etc.required for proper completion of work as directed by E/I.
177Rewinding and repair of burnt old and used 5 K.V.A. Voltas or equivalent make stabilizer for A.C. including cost of replacement of burnt wire and other minor parts including cost of all labour, materials,T&P etc.required for proper completion of work as directed by E/I.
178Supply and installation of 4KVA(90V-300V) Stabilizer of approved make suitable of 1.5 T A.C.make voltas or its equivalent including cost of all labour, materials,T&P etc.required for proper completion of work as directed by E/I.
179Supply and installation of 4KVA(130V-300V) Stabilizer of approved make suitable of 1.5T A.C. .make voltas or its equivalent including cost of all labour, materials,T&P etc.required for proper completion of work as directed by E/I.
180Supply and installation of 4KVA(150V-290V) Stabilizer of approved make suitable of 1.5T A.C.make voltas or its equivalent including cost of all labour, materials,T&P etc.required for proper completion of work as directed by E/I.
181Supply and installation of 4KVA(170V-285V) Stabilizer of approved make suitable of 1.5T A.C.make voltas or its equivalent including cost of all labour, materials,T&P etc.required for proper completion of work as directed by E/I.
182Supply and installation of 5KVA(90V-300V) Stabilizer of vgarud or equivalent make suitable of 2 Ton A.C.make voltas or its equivalent including cost of all labour, materials,T&P etc.required for proper completion of work as directed by E/I.
183Supply and installation of 5KVA(130V-300V) Stabilizer of vgarud or equivalent make suitable of 2 Ton A.C.make voltas or its equivalent including cost of all labour, materials,T&P etc.required for proper completion of work as directed by E/I.
184Supply and installation of 5KVA(150 V-290V) Stabilizer of vgarud or equivalent make suitable of 2 Ton A.C.make voltas or its equivalent including cost of all labour, materials,T&P etc.required for proper completion of work as directed by E/I.
185Supply and installation of 5KVA(170 V-285V) Stabilizer of vgarud or equivalent make suitable of 2 Ton A.C.make voltas or its equivalent including cost of all labour, materials,T&P etc.required for proper completion of work as directed by E/I.
186S/F of Relay for 1.50/2.0 Tone Window/Split A.C. Including all labour,material,T&P etc.required for proper completion of work as directed by E/I.
187Supply and fixing of Timer for 1.5T/2.0T split/window A.C. including all labour,material,T&P etc.required for proper completion of work as directed by E/I.
188S/F 10cm. Internal dia A.C. down pipe complet with rose, read, head, shoe, band and grating including supply of necessary M.S. clamps2.5cm x3cm (1\\"x1/8'') fixed to walls with and including supply of 15cm (6\\") long 6mm (1/4\\") dia nails etc.Including all labour,material,T&P etc.required for proper completion of work as directed by E/I.
189Supply & Fixing copper pipe for 1.5 Tonne/2 Tonne A.C.including all labour,material,T&P etc. required for proper completion of work as directed by E/I.( it is used to connect AC Indoor unit to outdoor unit)
190Repair of P.C.B.including changing of minor/burnt parts of window/split AC including all labour,material,T&P etc.required for proper completion of work as directed by E/I.
191Proper servicing of Kelvinator or equivalent make 165 liters capacity refrigerator including all labour, T&P etc. complete required for proper completion of work as directed by E/I. ( payment for replacement of parts of repair of parts shall be paid extra.)
192Proper Gas charging for 165 Litres refrigerator including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
193Rewinding of Motor of 165 litres refrigerator including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
194Replacement of damaged compressor of old used refrigerator make Hitachi or its equivalent upto 200lit. including gas charging, testing etc. all complete including all labour,material,T&P etc. required for proper completion of work as directed by E/I. ( Old and unserviceable and damaged compressor shall be contractor's property)
195Replacement of damaged compressor of old used refrigerator make Hitachi or its equivalent between 200lit to 500lit including gas charging, testing etc. all complete including all labour,material,T&P etc. required for proper completion of work as directed by E/I. ( Old and unserviceable and damaged compressor shall be contractor's property)
196Proper servicing of water cooler make Voltas,Blue Star or its equivalent including all labour, T&P etc. complete required for proper completion of work as directed by E/I. ( payment for replacement of parts of repair of parts shall be paid extra.)
197Proper Gas charging of water cooler including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
198Rewinding of Motor of water cooler including all labour,material,T&P etc. required for proper completion of work as directed by E/I.
199Replacement of damaged compressor of old used water cooler upto 80lit make Hitachi or its equivalent including gas charging, testing etc. all complete including all labour,material,T&P etc. required for proper completion of work as directed by E/I. ( Old and unserviceable and damaged compressor shall be contractor's property)
200Replacement of damaged compressor of old used water cooler between 80lit to 150lit make Hitachi or its equivalent including gas charging, testing etc. all complete including all labour,material,T&P etc. required for proper completion of work as directed by E/I. ( Old and unserviceable and damaged compressor shall be contractor's property)
201Repair and rewinding of burnt cooler/exhaust fan, motor coil with suitable copper wire including all labour,material,T&P etc.required for proper completion of work as directed by E/I. ( Burnt copper wire shall not be taken back from the contractor)
202Proper servicing of Bajaj make or equivalent 15 lit. to 25 lit capacity geysor with Disassembling, reassembling and greplacement of damaged parts and testing etc.required for proper completion of work as directed by E/I.
203S/Replacement of thermostate or heating element for 15 lit. 25 liter capacity Geysor. Including all labour,material,T&P etc.required for proper completion of work as directed by E/I.
204Supply and fixing of LED out door Bollard light for Lawn/Gaurden make approved quality required for proper completion of work as directed by E/I (NSI)
205Supply of fan room heater (Iron body) make USHA or its equivalent required for proper completion of work as directed by E/I.
206Supply of fan room heater (Plastic body) make ORPAT or its equivalent required for proper completion of work as directed by E/I.
207Supply of 1000watt room heater make USHA or its equivalent required for proper completion of work as directed by E/I.
208Supply of 2000watt room heater make USHA or its equivalent required for proper completion of work as directed by E/I.
209Supply and Fixing of 100watt LED flood light make Philips,Syska,Bajaj etc including all labours,materials & T&P etc.required for proper completion of work as directed by E/I.
210Supply and fixing of tray for window A.C. make approved quality required for proper completion of work as directed by E/I (NSI)
211Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C
212Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
213Supplying and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including junction box, cutting the wall and making good the same in case of recessed conduit as required.
214Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including junction box,cutting the wall and making good the same in case of recessed conduit as required.
215Wiring for circuit/ submain wiring with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
216Wiring for circuit/ submain wiring with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
217Wiring for circuit/ submain wiring with2 X 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
218Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required .
219Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
220Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
221Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
222Supplying and fixing 40 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
223Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
224Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
225Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
226Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
227Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)
228Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)
229Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)
230Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)
231Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)
232Supplying and drawing following 3 x 2.5 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
233Supplying and drawing following 3 x 4 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(DSR E&M 2022 1.17.21) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56414257
AUTHORITY Government Departments
TENDER VALUE 21.44 Lakhs
LAST DATE 16-07-2026
Authority
Authority Name Purvanchal Vidyut Vitaran Nigam Limited
Work Description Tender for Annual Electrical maintenance and repair Work Of New & Old M.D. Office, Inspection House, Customer Care Center, C.Z.E. Office, E.T.I, Badminton Hall And Officers/Employee Residences, At Vidyut Nagar, Bhikharipur, Varanasi.
Basic Detail
Tender No 55/ECDD(V)/2025-26
Bidding Type Tender
Location
City Varanasi
State Uttar Pradesh
Key Dates
Publish Date 11 Jul 2026
Submission Date 16 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 21.44 Lakhs
Tender Fee 2360
EMD 43000
Exemption Not Available
Document List
b8f15481-62a8-4f96-948c-4791725d2dab.html
BOQ_2191774.xls
specificationmdoffice.pdf
TENDERDOCUMENTSVARANASI.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

b8f15481-62a8-4f96-948c-4791725d2dab.html

xls

BOQ_2191774.xls

pdf

specificationmdoffice.pdf

pdf

TENDERDOCUMENTSVARANASI.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders