Tender For Repairing Of 16 Mtr High Mast 02 Nos, Led Street Light 29 Nos, Supply/Fixing Of 110 To 130W Led Street Light, Supply/Fixing Of Pannel For High Mast Light & Replacement Of Damage Cable At Nmy Ballia.
Tender Value
5.92 Lakhs
Estimated cost
Bid Submission
03 Aug 2026
22 days left
EMD
59200
Bank guarantee accepted
Document Fee
1400
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing Of 16 Mtr High Mast 02 Nos, Led Street Light 29 Nos, Supply/Fixing Of 110 To 130W Led Street Light, Supply/Fixing Of Pannel For High Mast Light & Replacement Of Damage Cable At Nmy Ballia.
BOQ
| Sl. No. | Item Description |
| 1 | To down 110 to 130 W LED street light from pole. 1424LR |
| 2 | To down of 170 to 200W LED flood light for repairing. 1455LR |
| 3 | Supply and fixing of 110 to 130W driver set. GEM |
| 4 | Supply and fixing SPD. Appd. |
| 5 | Refixing of 170 to 200W LED flood light after repairing. 1455LR |
| 6 | Refixing of LED street light on pole after repairing. 1424LR |
| 7 | Supply and Wiring of submains with 04 nos. of 4 sq. mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in charge. 289(C) |
| 8 | Supply and fixing of LED street light fitting with mandatory driver set having die cost aluminium houghing with toughend glass UV steplized PC cover and lenses Volte with mandatory driver set suitable for 110 watt to 130 Watt. Confirming to IP 66 and IK 07 and above protection complete in all respect. including lobour. CAT- AAA13200-15600 system lumens high power LED with lenses, (120Lm/W, PF>0.95, THD<10% at full load, CRI>70, potted driver set in metal housing (non circuilory) phase to phase protection at 440 V > 300V Over voltage auto cut and restart fealure, 4 KV internal surge protection, with 5 years warrantee. 8.14.16 |
| 9 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core 20c.1.9 |
| 10 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.50 sq. mm 3-1/2 core 20a.1.12 |
| 11 | Supply and layig of 100mm GI pipe medium B class. 15.13.3 DSR 2025 |
| 12 | S&F of 100 A. 415 V Metal clad TPN CFS complete with HRC fuse etc. on angle iron frame complete in all respect. 353 |
| 13 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve 1020(A) 2.13.2 |
| 14 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 25A TPN 807e(ii) |
| 15 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Incoming200Amp MCCB-01 Nos.Outgoing(i) 63amp MCCB- 03Nos.(ii) 80 to 100 Amp 4 pole MCCB (16 KA). 20.1.2(b)(ii)+1021 |
| 16 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting offluorescent / HPMV / HPSV street light fitting on poleincluding bending the pipe to the required shape, 2nos 40 mm X 3 mm flat iron clamps with nuts, boltsand washer, painting the flat iron with primer and finishpaint etc. as required. 13.34 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender