Tender For Supply Of Air-Conditioning Machine For The University Of Burdwan
Tender Overview
Project Description
Tender for Supply Of Air-Conditioning Machine For The University Of Burdwan , Supply & Installation Of Air-Conditioner , Supply & Delivery Of High-Wall 1.5/1.6 Ton Split-Type Air-Conditioner Having Following Specification: Cooling Capacity - 5.3 Kw (Minimum) , Minimum Iseer - 3.8, Bee Star Level - 3-Star(Min)[1St July22 To 31St December 2024] , Is Compliance - Is-1391(Part-I & Part-Ii) With All Amendment Refrigerant - R410a/R32 , Compressor - Rotary/Scroll , Evaporator & Condenser Coil - Copper Operating Outdoor Temperature - 50ºc And Above , Power Supply -230V, 50Hz (±Tolerance Asper Applicable Standard),As Directed By Eic. , The Scope Of Work Is Also Includes Supply Of Following (I) Necessary Refrigeration Copper Line With Nitrile Rubber Insulation And Wrapping Tape - 3 Mtr (Ii) Necessary S& L Soft Drawn Pvc Drain Pipe 19 Mm Dia With Proper Supports & Brackets As Per Direction Of Eic.(Make-Suprime/Oriplast) (Iii) Necessary 3/4 Core Copper Cable (Frls Type - Make : Finolex/Rr Kable/Polycab/Havells/Gloster) - 3Mtr And Suitable Plug Top(Anchor/North West/Legrand/Havells) With Supply And Fixing Of Strong Grade Angle Bracket For Outdoor Mounting. , If Require Extra Copper Refrigeration Pipe Line For Liquid Line (1/4 Od With .06 Mm Thick) With Proper Supports & Brackets For 1.5 / 2 Tr Hi-Wall Split Ac As Directed By Eic.(Make-Ryoku/Uniflow) , If Require Extra Copper Refrigeration Pipe Line For Suction Line (5/8 Od With .06 Mm Thick) With Proper Supports & Brackets For 1.5 / 2 Tr Hi-Wall Split Ac As Directed By Eic.(Make-Ryoku/Uniflow) , If Require Extra Supply/Fixing Pipe Insulation For Liquid Line (1/4 Od With 9 Mm Thick)With Proper Insulating For 1.5 / 2 Tr Hi-Wall Split Ac As Directed By Eic.(Make-Accroflex/Suprime) , If Require Extra Supply/Fixing Pipe Insulation For Suction Line (5/8 Od With 9 Mm Thick)With Proper Insulating For 2 Tr Hi-Wall Split Ac As Directed By Eic.(Make-Accroflex/Suprime) , If Require Extra Control Cabling From Condensing Unit To Control Panel 3 Core 2.5 Sq.Mm Communication Cable 1.5 / 2 Tr Hi-Wall Split Ac As Directed By Eic.(Make-Polycab/Kei/Finolex) , If Require Extra S& L Soft Drawn Pvc Drain Pipe 19 Mm Dia With Proper Supports & Brackets As Per Direction Of Eic.(Make-Suprime/Oriplast) , Supply & Delivery Of Window Type Air-Conditioner Having Following Specification: Cooling Capacity - 1.8 / 2 Ton Minimum Iseer - 3.8, Compliance - Is-1391(Part-I & Part-Ii) With All Amendment Refrigerant - R410a/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating Outdoor Temperature - 50ºc And Above Power Supply -230V, 50Hz (±Tolerance As Per Applicable Standard),As Directed By Eic. The Scope Of Work Is Also Includes Supply Of Following (I) Necessary 3/4 Core Copper Cable (Frls Type - Make : Finolex /Rr Kable/Polycab/Havells/Gloster) - 3Mtr And Suitable Plug Top(Anchor/North West/Legrand/Havells)
BOQ
| Sl. No. | Item Description |
| 1 | Supply & Installation of Air-Conditioner |
| 2 | Supply & Delivery of High-wall 1.5/1.6 ton Split-type Air-Conditioner having following specification:Cooling Capacity - 5.3 KW (Minimum) , Minimum ISEER - 3.8, BEE Star level - 3-Star(min)[1stJuly22 to 31st December 2024] , IS Compliance - IS-1391(Part-I & Part-II) with all amendmentRefrigerant - R410A/R32 , Compressor - Rotary/Scroll , Evaporator & Condenser Coil - CopperOperating outdoor temperature - 50ºC and above , Power supply -230V, 50Hz (±tolerance asper applicablestandard),as directed by EIC. , The scope of work is also includes supply of following(i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3 mtr(ii) Necessary S& L Soft Drawn PVC Drain pipe 19 mm dia with proper supports & brackets as per direction of EIC.(Make-Suprime/Oriplast) (iii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RRKable/Polycab/Havells/Gloster) - 3mtr and suitable plug top(Anchor/North West/Legrand/Havells) with supply and fixing of strong grade angle bracket for outdoor mounting. |
| 3 | IF REQUIRE EXTRA Copper Refrigeration pipe line for Liquid Line (1/4\\" OD with .06 mm thick) with proper supports & brackets for 1.5 / 2 TR HI-wall Split AC as directed by EIC.(Make-Ryoku/Uniflow) |
| 4 | IF REQUIRE EXTRA Copper Refrigeration pipe line for Suction Line (5/8\\" OD with .06 mm thick) with proper supports & brackets for 1.5 / 2 TR HI-wall Split AC as directed by EIC.(Make-Ryoku/Uniflow) |
| 5 | IF REQUIRE EXTRA S/F Pipe Insulation for Liquid Line (1/4\\" OD with 9 mm thick)with proper Insulating for 1.5 / 2 TR Hi-wall Split AC as directed by EIC.(Make-Accroflex/Suprime) |
| 6 | IF REQUIRE EXTRA S/F Pipe Insulation for Suction Line (5/8\\" OD with 9 mm thick)with proper Insulating for 2 TR Hi-wall Split AC as directed by EIC.(Make-Accroflex/Suprime) |
| 7 | IF REQUIRE EXTRA Control cabling from Condensing Unit to Control Panel 3 core 2.5 sq.mm communication cable 1.5 / 2 TR Hi-wall Split AC as directed by EIC.(Make-Polycab/KEI/Finolex) |
| 8 | IF REQUIRE EXTRA S& L Soft Drawn PVC Drain pipe 19 mm dia with proper supports & brackets as per direction of EIC.(Make-Suprime/Oriplast) |
| 9 | Supply & Delivery of window type Air-Conditioner having following specification:Cooling Capacity - 1.8 / 2 tonMinimum ISEER - 3.8, Compliance - IS-1391(Part-I & Part-II) with all amendmentRefrigerant - R410A/R32Compressor - Rotary/ScrollEvaporator & Condenser Coil - CopperOperating outdoor temperature - 50ºC and abovePower supply -230V, 50Hz (±tolerance as per applicable standard),as directed by EIC.The scope of work is also includes supply of following (i) Necessary 3/4 core copper cable (FRLS type - make : Finolex /RR Kable/Polycab/Havells/Gloster) - 3mtr and suitable plug top(Anchor/North West/Legrand/Havells) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender