Tender for Revival & Restoration Of Saint Johns Church At Pahalgam. Advt.Cost=₹71.32.00 Lacs, Amount Without Gst= ₹ 60.44 Lacs, Gst Amount= ₹ 10.88 Lacs
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of G.S. Sheet |
| 2 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead of sectional area 40 sqcm. and above. |
| 3 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 meters lead Thickness above 25 mm upto 40 mm. |
| 4 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge In cement mortar |
| 5 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 1 meter from cutting edge. in all kinds of Soil |
| 6 | Providing and laying of stone soling, hand packed, including carriage of same from approved source upto site of work complete. |
| 7 | Providing and laying in position cement concrete in 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded crushed stone aggregate, 40mm nominal size) excluding the cost of centering and shuttering |
| 8 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Providing and laying in position cement concrete in 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate, 20mm nominal size) excluding the cost of centering and shuttering. |
| 11 | Centering & shuttering including strutting, propping etc including removal of form work for for foudations , footing and basis of columns. |
| 12 | Centering and shuttering incl. strutting, propping etc and removal of form work )Lintels , beams , plinth beams , girders , centilevers etc. |
| 13 | Brick work with common burnt clay bricks F P S bricks of class designation 75 in exposed brick work including making of horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 mix incl extra for brick work in sp structure above plinth level upto floor five level |
| 14 | Reinforcement for R C C work including straightening , cutting, bending, placing in position and binding all complete |
| 15 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class kail wood |
| 16 | Providing and fixing glazed shutters for doors, windows and clerestory windows Rate for thickness of using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 35MM Second class Kail wood |
| 17 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Second class Kail wood |
| 18 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt 35mm 30mm hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class Kail wood |
| 19 | Providing 40 X 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts , nuts and wooden plugs and embeddings in cement concrete block 30 10 15 cm of 1:3:6 mix with 20 mm nominal dia aggregates. |
| 20 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 21 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 22 | P/F of 12mm thick imported wood paneling of approved pattern over and including base of 10mm thick plywood with frame work of Budloo finishing exposed surface with two of more coats of touch wood and polish including cost of nails, adhesive material etc. and all carriages |
| 23 | Providing hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. complete First class Budloo |
| 24 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 25 | Providing and fixing bolts including nuts and washers complete. 16mm |
| 26 | Providing High Rib Colour coated G. I. sheet roofing including vertical/curved surfacfixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled withwhite lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch inhorizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 27 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 0.50 mm |
| 28 | Providing valleys of 90cm wide overall in plain G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 1.00 mm thick with zinc coating not less than 275 gram/m2 |
| 29 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood on 12 mm thick plyboard including the cost of Framework and including providing and apllying wood polish over prepared surface after sandpapering, applying sealer etc complete job Chaar Gul |
| 30 | Providing and fixing plained eaves boarding. 2nd class Deodar wood 300x40 mm (nominal size) heritage type |
| 31 | Ruled/flush pointing on white sand stone masonry surface with lime, surkhi and marble dust mortar in the ratio 1:1.5:1/2 one lime : 1.5 surkhi ( 50% red and 50% light yellowsurkhi):1/2 marble dust ( the rate is inclusive of all materials and labours involved I/C SCAFFOLDING, ALL CARRIAGES |
| 32 | Providing and fixing of Dajji Deewari in deodar wooden cladding (6\\"x 1\\")on outer side of building including scaffolding, Painting etc all costs complete |
| 33 | Applying priming coat with ready mixed Pink or grey primer of approved brand and manufacture on WOOD work (hard or soft wood) |
| 34 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade . Two or more coats on new wood work |
| 35 | P/F PVC conduits 25mm dia (Finolex or equivalent brand) |
| 36 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 37 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 38 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete Job 125x85x5.5 mm (heavy type) |
| 39 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x85x5.5 mm (heavy type) |
| 40 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. : 250x10 mm |
| 41 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. : 100x10 mm |
| 42 | Providing and fixing bright finished brass door latch with necessary screws etc. complete job 300x165x 5 mm |
| 43 | Providing and fixing bright finished brass handles with screws etc. complete : 100 mm |
| 44 | P/F of ornamental (Brass) main door handles 125mm with screws complete |
| 45 | Carriage of materials for an avg lead of 50 Kms by using MT |
| 46 | Carriage ofBricks for an avg lead of 50 Kms by using MT |
| 47 | Electrical Part: Wiring for lighting points/fan points/exhaust fan points/coll boll points with 2x1.5 sq mm FRLS/HEER PVC insulated floxible stranded copper conductor wires in racessed or surface 1 medium class PVC condult, with 240V GA modular switch,modular plato, suitable Gl box and 2 earthing the point with 1,5 sq mm FRLS/HFFR PVC insulated copper conductor singla core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK) including the cost of conduit. |
| 48 | Supply, Installation, Testing and Commissioning of 18W/ LED recessed mounted (round or square) Down lighters having aluminum body, minimum 100 lm/w, average life 50000 hours. Operating Temperature -10°C to +45°C. Certification-LM79 & LM80 test report should be from govt approved In-house NABL/ lab Government of India. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning handing over of siTe to the intending department. (Havells/ Philips/ Crompton/Jaguar/Wipro) |
| 49 | Supply, installation, lesting and commissioning of 1200 mm (48\\") BEE Star rated energy-efficient ceiling fan, complete with 3 Nos. aluminum blades, downrod, canopy, capacitor, safety pin, nuts, bolts and washers, suitable for 230 V, 50 Hz AC supply. The fan shall have air delivery not less than 220 m³/min, rated speed (RPM) between 340-380 (as per 3 manufacturer's specification), power consumption not exceeding 50 watts, service valuo z 6.0, noise level ≤ 60 dB, insulation class 'B' and Insulation resistance > 2 ΜΩ. Fan shall bo of approved make such as Usha / Havells / Crompton/Orient or equivalent, including installation, online RPM verification, testing, commissioning and handing over to the Engineer in-Charge, with minimum 2-year manufacturer warrant |
| 50 | Supplying and fixing ISI-marked 6 A, 250 V modular step-type electronic fan regulator (2 Module), conforming to IS:3854 or latest IS standards, mounted on suitable modular plate with Gl flush box, Including wiring connections, testing and commissioning, of approved make such as Anchor Roma/Legrand/Schneider / Havells, complete as per direction of the Engineer-in-Charge. |
| 51 | Supply, Installation, Testing and Comm. Of 200/250mm sweep exhaust fan Shutter type of havell /Bajaj/ Crompton/equivalent make as directed by engineer incharge, Air Flow capacity >850cmph, 35-50Watts, Noise level 44db, 1200 rpm, water resistant, including making of space in wall/ window as per site requirement and necessary connections. The job includes replacement warranty of fixture if damaged/burn out what so ever reason for a period of two years reckoned from the date of sucessful commissioning / handing over of site to the intending department. (To be got approved before installation from EIC) |
| 52 | Supply, Installation, Testing and Commissioning of 100W (Havells/ Phillips/Wipro skyline) new generation energy saving and environmental friendly long life L.E.D Flood Light made up of pressure die cast Aluminum housing with high efficiency LEDs as lighting source with efficacy >110lm/w, CRI>80,CCT>5000, Avg Life L70 50000 hours, No haremful UV and IR radiators, Operating Temp -10°C to +45°C, Surge Voltage Protection, IP66 Protection and impact resistance of IK07. The Job Includes replacement warranty of fixture if damaged/burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/handing over of site to the intending department |
| 53 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required. (Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo/Crabtree athena make). |
| 54 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc. as required. (Anchor roma plus/Legrand Mylino /SSK/Schneider Zencelo /Crabtree athena make). |
| 55 | Wiring for AC/Power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, elc, as required. (Havells/ Polycab/Anchor/ SSK) including the cost of conduit. |
| 56 | Wiring for 5-10A socket out lets for computer with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havelis/ Polycab/ Anchor/ SSK) as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required including the cost of conduit. |
| 57 | Supplying and fixing of indicators on existing modular plate and switch box, Incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent). |
| 58 | Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired. |
| 59 | Supply and fixing of 8 way (4+24), Double door surface/ recess mounting, Horizontal type, three pole and neutral, sheet steel, MCB distribution board,415V, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. |
| 60 | Supply, Installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA \\"C\\" curve MCB of Legrand/Havells/ L&T/ABB suitable for Inductive load in the MCB distribution board complete with necessary connections. |
| 61 | upply, Installation, testing and commissioning of 40A-32A DP rating 240/415V, 10 КА \\"С\\" Curve MCB of Legrand/ Havells/L&T/ABB suitable for inductive load in the MCB distribution board |
| 62 | Supply, Installation, testing and commissioning of G.JA DIP rating 240/415V, 10 KA \\"C\\" curve 16 MCD of Legrand/Havells/L&T/ADD suitable for inductive load in the MCB distribution board complete with necessary connections, |
| 63 | MAIN PANEL: Design, fabrication, supply, Installation, losling, and commissioning of Main Distribution Doard (MDD), duly manufactured from CPRI-approved manufacturor, made out of 12 SWG CRCA (15 375) mild steel sheet, 2 mm thick, powder-conted with RAL 7035, floor/wall-mounted, vermin and dust-proof, indoor type. The panel shall bo provided with suitable sizo angle Iron legs for grouting In the ground, lockable hinged doors, and painted finish. The 18 enclosure shall have provisions for fixing switchgears, Aluminium bus bars of various ratings (considering darating factor), and other allied accessorios as required. The panel shall be fabricated as per approved design; sizo may vary according to sito requirements. The panel shall fully comply with IS 8623/IEC 61439 standards for low voltage switchgear assemblies. The work includes all internal wiring, thimbles, ferrulos, nuts, bolts, washers, gland plates, earthing lugs, Insulation sleeves and all other accessories necessary |
| 64 | Providing and fixing of following protection equipments and other allied accessories including connections, Inter connections, with sultable size of PVC Insulated copper conductor cable including earthing etc, as required. Normal Incoming ) a) 125A DP MCB 10 KA Havells/Legrand/ Schinlder/ABB/L&T sample to be approved before installation.. |
| 65 | b) 4 No. of Aluminium Bus Bar of 300 Amp. |
| 66 | c) Digital meters and phase Indicators |
| 67 | Inverter a) 32A DP MCB 10KA |
| 68 | b) 2. No of Aluminium Bur Bar of 63 Amp |
| 69 | c) Digital meter and phase Indicators |
| 70 | Wiring for Circuit/Sub mains along with earth wire In FRLS PVC Insulated 660/1100 volt 28 grade flexible stranded copper conductor wires in recessed or surface conduiting system, including the cost of conduit. (Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent). a) 2X 10Sq Mm+1x 1 x Sq MM Heating Sub Main |
| 71 | b) 2x 6 sq mm + 1x 6 sq mm Lighting submain |
| 72 | c) 2x 4 sq mm + 1x 4 sq mm Inverter submain |
| 73 | d) 2x 2.5 sq mm + 1x 2.5 sq mm inverter & normal Circuit |
| 74 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and 33 providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Complete Job. |
| 75 | Providing and laying earth connection from earth electrode with 8 mm dia copper wire in 15 34 mm dia G.l. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 76 | Supplying, Laying and fixing of Suitable Fan Junction Box in Slab.sample to be approved |
| 77 | Providing and fixing of Deep boxes for lights in Slab, sample to be approved by EIC |
| 78 | Supply, laying, connecting and commissioning of 16 sq mm 2 core XLPE/PVC 37 Insulated and steel armored 1.1 KV grade Aluminum LT cable for Service line, incl. cost of required al. thimbles duly crimped. (Over head/ under ground). |
| 79 | Supply, Installation, testing and commissioning of 1625-2000 VA (2 kVA), 12 V, single-phase pure sine wave Inverter with inbuilt charger and automatic changeover, conforming to IS 16242/IEC standards, Including supply of 2 Nos. 12 V, 180 Ah tall tubular lead-acid batteries (IS 13369/IS 1651) mounted on PVC/FRP battery trolley, complete with interconnecting cables, terminals, DC fuse/isolator, AC wiring, initial charging, commissioning, and all accessories, duly approved by Engineer-in-Charge. |
| 80 | Supply and erection of Mild Steel Swaged Tubular Pole confirming to IS: 2713-1980 (Part I-II) with base plate. The pole shall be made from steel tube and pipe (IS: 1141, Fe 410)including excavation of the pit and filling up the same with cement concrete of M15 Grade (1: 2: 4 mix) from base plate to 50 cm above ground level, earthing terminal, cable entry with 32mm dia B-class GI cable sleeves. The pole shall be painted with 2 coats of red oxide primer and 2 coats of enamel paint of silver. The job also includes the cost of form work and carriage of all required materials. (9 mtr. 410 SP-28). |
| 81 | Providing and fixing of detachable type round or square bracket (suitable for 6 lights) of 32/35 mm dia. Gl pipe as per requirement. 40 |
| 82 | Providing & Fixing of IKO8 IP-66 120W protected high power LED flood light system with single piece Pressure diecast aluminum housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to S watt each. Integrated potted driver as a unique BIS R number having more than 85% and in compliance to BIS certified and Trade mark certificate. (he Systern level Luminary efficacy >=1 wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff V AC an uto resetting Safety Power Factor >0.95, THD(1) <10%, driver current) <=750mA. driver should be Phase ophase protection of 440 V for 4 Hrs Electrical Connector, Surge Protection Min >24KV Internal and 10KV external but inside driver compartment, Systern life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700k $355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/ authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABI lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from. OEM shall be submitted |
| 83 | S/L, tosting and commissioning of, 10 sq mm 2 core XLPE Insulated, PVC aluminum annored cablo 650 V/1100 V Grado as per IS 7098 (Part 1) 1988 with upto Date 12 Amandments. Havolls or Eq. standard mako as directed by anginoor Incharge and making end termination with brass compression gland and aluminum lugs of reqd size. |
| 84 | Supply, Installation, tosting and commissioning of floor mounted compartmentalized, out door typo main distribution panels (each with 4 angle Iron leg), fabricated out of 16 gauge sheet steel, water proof, dust protected, painted, Incl. earth terminal with all necessary accossorios with Internal wiring as required. Tho panol is to bo provided with the following adjustable type controlling/ protection switch gear devices:1.NORMAL INCOMING100A DP MСВ 10КА 01 по.200A SP&N bus bar AL. Strips 01 setDigital meter and phase Indicators 01 set.Space for 08 way MCBs The panel should have a compartmental space for housing a 2 KVA voltage stabilizer. The job also includes the cost of providing and laying of cement concrete block of M15 grade. (2-0\\" x 3'-0\\" x 1\\"-6\\") The job also includes the cost of form work and carriages of all required materials. |
| 85 | Supplying and drawing FRLS PVC Insulated copper conductor single core cable through pole up to light Inside Conduit 3 x 2.5 sq. mm (P+N+Loop Earth) |
| 86 | Providing and fixing/ laying of earthing station by way of placing Gi electrode rod/ pipe in a pit connected through Gl strip. (complete job) |
| 87 | Providing and fixing of IP 65 proct impact resistant polycarbonate enclosure box with knock out for cable entry fout including fixing with nut bolt fastner etc required complete in all respect of following size along with 63 A connector and 3 no. 6A MCB for controlling the High Mast Lights. 250 x 200 x 115 mm |
| 88 | Supply, Installation, testing and commissioning of 2 KVA relay type voltage stabilizer operating froar input voltage 90-260Volt thereby producing output voltage of 230volts + 3%. |
| 89 | Providing chemical earthing as per IS standards by way of digging 8 feet pit then embedding 3 mtr. Long Gl earthing electrode, 80 mm dia. Connecting the plate with main centrol board by 10 SWG Copper wire with 1/2\\" dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound |
| 90 | Construction of path Inside Church: Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 91 | P/L Stone soling/RBM i/c leveling , conslidation including cost andcarriage of all materials involved (complete job). |
| 92 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 93 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 94 | P/L Chisel Dressed/ Machine cut Devri tiles of size 300x200mm and 50mm thick,fine chiseled front face and rough bottom for bonding in cement mortar 1:4 in required design pattern incl spacer for uniform spacing as directed by EIC |
| 95 | Providing and laying rough chisel dressed Devri Stone in kerbs, of size 200x200 mm face with chamfer in cement mortar 1: 6 (1 cement : 6 coarse sand) including curing. |
| 96 | Providing and laying chisel dressed Devri Stone of size 300x200 mm face with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing. One face dressed Rough chisel dressed |
| 97 | carriage of material by using mech tpt for an average lead of 50 kms Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysJul 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents