Housing Urban and Rular Development Government Departments Closing in 13 days TDR #56412431

Tender For B.O.Q For Off Beat Destination Upgradation Of Aharbal B.W.O Upgradation Of Departmental Hut, Construction Of 4 Units Toilet Complex With Tuck Shop, Providing And Installation Of Signages, Solid Waste Management Alongwith Providing Of Dust

Issued by Government Departments · Kulgam, Jammu and Kashmir
Tender Value
11.23 Lakhs
Estimated cost
Bid Submission
24 Jul 2026
13 days left
EMD
22475
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kulgam → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for B.O.Q For Off Beat Destination Upgradation Of Aharbal B.W.O Upgradation Of Departmental Hut, Construction Of 4 Units Toilet Complex With Tuck Shop, Providing And Installation Of Signages, Solid Waste Management Alongwith Providing Of Dust Bins, Construction Of Selfie Points, Lighting/ Illumination, Development Of Hiking Trails B.W.O Signages, Benches, Installation Of Zipline, Installation Of Children Recreation Zone [ Part A: Electrification Of Toilet Complex Dh Pora, Part B: Repairment Of Lighting And Heating Points Of Dak Bungalow Aharbal, Part C: Lighting/ Illumination Works { Supply, Installation And Commissioning Of Led Flood Lights At Tourist Office Aharbal} ]

BOQ

Name of Work:- B.O.Q for Off beat destination Upgradation of Aharbal B.W.O Upgradation of Departmental Hut, Construction of 4 units Toilet Complex with Tuck shop, Providing and installation of Signages, solid waste management alongwith providing of dust bins, construction of selfie points, lighting/ illumination, development of hiking trails B.W.O signages, benches, installation of zipline, installation of children recreation zone [ Part A: Electrification of Toilet Complex DH Pora, Part B: Repairment of lighting and heating points of Dak Bungalow Aharbal, Part C: Lighting/ Illumination works { Supply, Installation and Commissioning of LED Flood Lights at Tourist Office Aharbal} ]
Sl. No. Item Description
1Part A: Electrification of Toilet Complex DH Pora
2Wiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ Apar/ SSK/KEI/RR or equivalent make ) including the cost of conduit.
3Supply, Installation, Testing and Commissioning of 15W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro).
4Supply, Installation, Testing and Commissioning of 50W warm type (Havells/ PhillIps/Wipro skyline ) new generation energy saving and environmental friendly long life L.E.D Flood Light made up of pressure die cast Aluminum housing with high efficiency LEDs as lighting source with efficacy >110lm/w ,CRI>80 ,CCT>5000 ,Avg Life L70 50000 hours ,No haremful UV and IR radiators, Operating Temp -10 to 45C ,Surge Voltage Protection, IP66 Protection and impact resistance of IK07.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department.
5Supply, Installation, Testing and Comm. Of 200/250mm sweep exhaust fan Shutter type of havell /Bajaj/ Crompton/equivalent make as directed by engineer incharge,Air Flow capacity >850cmph, 35-50Watts,Noise level 44db, 1200 rpm,water resistant, including making of space in wall/ window as per site requirement and necessary connections.The job includes replacement warranty of fixture if damaged/burn out what so ever reason for a period of two years reckoned from the date of sucessful commissioning / handing over of site to the intending department.(To be got approved before installation from EIC)
6Supply, Installation, Testing and Commissioning of 1200 mm sweep ceiling fan single star with 3 No. Aluminium blades, reqd. long down rod, 2nos. canopies, safety cable, shackle kit, Power Factor not less than 0.9, 45-54W, Air flow 7200-7500cfm, RPM>340, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete job.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the indenting department (USHA/ Havells/ Crompton/Phillips/bajaj) as directed by engineer incharge.
7Supply and fixing of 6A/250 V AC fan dimmer step type 2 module with coverplate Anchor Roma plus/SSK NV/ equivalent make as directed by engineer incharge.
8Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make).
9Supplying and fixing of GI box along with modular base and cover plate for modular sockets, switches in recess etc as required 6 module (200mm x 75mm)
10Supplying and fixing of 5pin 5-10A socket and 5-10A switch on existing modular plate, incl connections etc as required. (Havells/SSK/Anchor/ABB/Schneider)
11Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, etc. as required.(Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) including the cost of conduit.
12Wiring for 5- 10A socket out lets for computer (inverter) with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required. including the cost of conduit.
13Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent).
14Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired.
15Supply and fixing of 6 way (4+18), Double door surface/ recess mounting, Horizontal type, 240 V, SP&N MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK/Schnider/ABB)
16Supply, installation, testing and commissloning of 5-32A single pole rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable forinductive load in the MCB distribution board complete with necessary connections.
17Supply, installation, testing and commissioning of 32A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections.
18Supply, installation, testing and commissioning of 40A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections.
19Supply, installation, testing and commissioning of 63A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections.
20Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required. (As per approved design,size may vary as per site requirement)
21Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
221. Normal INCOMING:
23a)100 A DP MCB 10 KA Havells/Legrand/ Schinider/ABB/L&T sample to be approved before installation..
24b) 2 No. of Aluminium Bus Bar of 200 Amp.
25c)Digital meters and phase indicators -1 set.
26Outgoing :
27a) 32A DP MCB 10KA
28b) 2 No. of Aluminium Bus Bar of 63 Amp.
29c) Digital meter and phase indicators 01 set.
30Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, including the cost of conduit. (Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent).
312x10 sq mm +1x6 sq mm Heating submain
322x 6 sq mm + 1x 6 sq mm Inverter Lighting submain
332x 4 sq mm + 1x 4 sq mm Lighting submain
342x 2.5 sq mm + 1x 2.5 sq mm Lighting circuit
35Supply, laying, connecting and commissioning of 35 sq mm 2 core XLPE/ PVC Insulated and steel armored 1.1 KV grade Aluminum LT cable for Service line, incl. cost of required al. thimbles duly crimped. (Over head/ under ground).
36Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting the concrete path wherever required,jointing etc.direct in ground including excavation and refilling the trench with soft excavated earth making the surface level but excluding sand cushioning and protective covering etc., complete as required.
3763 mm dia (OD-63 mm & ID-51 mm nominal)
38Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.Complete Job.
39Providing and laying earth connection from earth electrode with 8 mm dia GI wire in 15 mm dia G.l. pipe from earth electrode including connection , excavation and re-filling as required.
40Supply, installation, testing and commissioning of minimum 2 kVA, 12 V, single-phase pure sine wave inverter with inbuilt charger and automatic changeover, conforming to IS 16242/IEC standards, including supply of 2 Nos. 12 V, 200 Ah tall tubular lead-acid batteries (IS 13369/IS 1651) mounted on PVC/FRP battery trolley, complete with interconnecting cables, terminals, DC fuse/isolator, AC wiring, initial charging, commissioning, and all accessories, duly approved by Engineer-in-Charge.
41Part B: Repairment of lighting and heating points of Dak Bungalow Aharbal
42Wiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) excluding the cost of conduit.
43Supply, Installation, Testing and Commissioning of 12 W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro).
44Supply, Installation, Testing and Commissioning of 50W (Havells/ PhillIps/Wipro skyline ) new generation energy saving and environmental friendly long life L.E.D Flood Light made up of pressure die cast Aluminum housing with high efficiency LEDs as lighting source with efficacy >110lm/w ,CRI>80 ,CCT>5000 ,Avg Life L70 50000 hours ,No haremful UV and IR radiators, Operating Temp -10 to 45C ,Surge Voltage Protection, IP66 Protection and impact resistance of IK07.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department.
45Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make).
46Supplying and fixing of GI box along with modular base and cover plate for modular sockets, switches in recess etc as required 6 module (200mm x 75mm)
47Supplying and fixing of 5pin 5-10A socket and 5-10A switch on existing modular plate, incl connections etc as required. (Havells/SSK/Anchor/ABB/Schneider)
48Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent).
49Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired.
50Supply, installation, testing and commissloning of 5-32A single pole rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessaryconnections.
51Supply, installation, testing and commissioning of 40A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessaryconnections.
52Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, excluding the cost of conduit. (Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent).
533x4 sq mm
543x2.5 sq mm
55Supply, laying, and fixing of 25mm dia PVC Conduit (FRLS type), medium class, confirming to IS: 9537 standards, including all necessary accessories such as bends, couplers, tees, saddles, and junction boxes, complete as per site requirements and specifications.
56Part C: Lighting/ Illumination works { Supply, Installation and Commissioning of LED Flood Lights at Tourist Office Aharbal}
57Supply, installation, testing and commissioning of 100Watt LED Flood lighting luminaries having aluminum body, minimum 100lm/w, the luminary housing should be aluminum and the luminary optics shall have a high efficiency with transmittance, average life 50000 hours, Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the indenting department
58Wiring for lighting points points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch , modular plate and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent make ) incl. cost of conduit.
59Supply and erection of Mild Steel Swaged Tubular Pole confirming to IS: 2713-1980 ( Part I-II) with base plate. The pole shall be made from steel tube and pipe (IS : 1141, Fe 410)including excavation of the pit and filling up the same with cement concrete of M15 Grade (1: 2: 4 mix)from base plate to 50 cm above ground level, earthing terminal, cable entry with 32mm dia B- class GI cable sleeves. The pole shall be painted with 2 coats of red oxide primer and 2 coats of enamel paint of silver. The job also includes the cost of form work and carriage of all required materials. (9 mtr. 410 SP-28).
60Providing and fixing of detachable type round or square bracket (suitable for 4 lights) of 32/35 mm dia. GI pipe as per requirement.
61Providing & Fixing of IKO8 IP-66 120W protected high power LED flood light system with single piece Pressure diecast aluminum housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to S watt each. Integrated potted driver as a unique BIS R number having more than 85 % and in compliance to BIS certified and Trade mark certificate. [he System level Luminary efficacy >=1 wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff V AC an uto resetting Safety Power Factor >0.95, THD(I) <10%, driver current) <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs Electrical Connector, Surge Protection Min >24KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700k $355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/ authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABI lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from. OEM shall be submitted.
62Providing and fixing of IP 65 proct impact resistant polycarbonate enclosure box with knock out for cable entry /out including fixing with nut bolt fastner etc required complete in all respect of following size along with 63 A connector and 2 no. 6A MCB for controlling the High Mast Lights. 250 x 200x 115 mm
63Supply, installation , testing and commissioning of 4 KVA relay type voltage stabilizer operating from input voltage 90-260Volt thereby producing output voltage of 230volts +_ 3%.
64Supplying and drawing FRLS PVC insulated copper conductor single core cable through pole up to light. 3x2.5 sq mm for high mast lights, circuit wire for the flood light installed to be their on the tourist office.
65Supply, Installation, Testing and Commissioning of Heritage architectural ornamental decorative cast iron pole as per specification/ drawing (enclosed) Mayfair/Bright Solar with the following specifications:- The pole shall look like as shown in the drawing. It shall have all similar features as shown in the enclosed drawing/picture. The Cast Iron Pole of 4000mm including bracket and 3000mm without bracket with ornamental base, bottom dia 375mm and shall have a provision of 4 No. bolts and inbuilt junction box for fixing MCB’s/Connector or cutouts with detachable window cover including their costs. The part above ornamental base design consists of decorative sections of circular shapes & collar in different dimension, is made of cast iron in fine finish. The design of the cast-iron parts is clearly shown in the drawing. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%) Further the pole shall be got approved by the concerned engineering wing after providing a sample before execution of work and the test certificate to be provided by the manufacturer.
66Supply and fixing of ornamental Cast iron and mild steel 2 way bracket painted with anti-corrisive enemal paint as per design, of Mayfair/Dwarka or of equivalent make/design (as per enclosed drawing) The bracket should have a provision of fixing LED luminaries (warm) on both sides as shown in the drawing ,including the cost of light fixture with 45W led light including globe i.e complete job. Further the bracket shall be got approved by the concerned engineering wing after providing a sample before execution of work and the test certificate to be provided by the manufacturer.
67Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:
68Providing and laying in position cement concrete including curing but excluding the cost of shuttering and centring with 1:1.5:3 (1 cement, 1.5 Coarse sand, 3 Graded stone aggregate 20 mm nominal size). The dimensions of the block should be 4'x2'x2'.
69Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete.Thermo-Mechanically Treated bars of grade Fe-500D or more with 60 kg/cum.
70Supply, Installation , testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
71a) 25 sq.mm 2 core from LT pole to Panel
72a) 10 sq.mm 2 core for ornamental poles and high mast lights
73Providing of service connection and earthings to luminaire from the junction box in 1.5 mm PVC insulated, multicolour copper wire (FRLSH) .Havells/Polycab/SSK/KEI.
74Supply and installation of Spiral Earthing through 10 swg GI wire after driving in ground up to a depth of 3' in the ground from the base of the pole.
75Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting the concrete path wherever required,jointing etc.direct in ground including excavation and refilling the trench with soft excavated earth making the surface level but excluding sand cushioning and protective covering etc., complete as required.
7635-40 mm dia
77Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel made out of 2mm thick M.S. sheet, , vermin and dust proof, Outdoor type with suitable size of angle iron legs grouted in the cement concrete., with lockable type hinged doors, duly painted with provision for fixing of incomer MCCB, outgoing DP MCBS, sets of Aluminium Bus Bar of different rating. after taking Derating factor into account, and other allied accessories etc. as required. the panel to be fabricated from reputed firm duly approved by CPRI.as per approved design, size may vary as per site requirement)
78Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
79INCOMING:
80a)63A DP MCB (Legrand/ Shinider/L&T/ABB make).
81b) 2 No. of Aluminium Bus Bar of 100 Amp.
82OUTGOING:
83b)5-32 SPMCB Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56412431
AUTHORITY Government Departments
TENDER VALUE 11.23 Lakhs
LAST DATE 24-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for B.O.Q For Off Beat Destination Upgradation Of Aharbal B.W.O Upgradation Of Departmental Hut, Construction Of 4 Units Toilet Complex With Tuck Shop, Providing And Installation Of Signages, Solid Waste Management Alongwith Providing Of Dust Bins, Construction Of Selfie Points, Lighting/ Illumination, Development Of Hiking Trails B.W.O Signages, Benches, Installation Of Zipline, Installation Of Children Recreation Zone [ Part A: Electrification Of Toilet Complex Dh Pora, Part B: Repairment Of Lighting And Heating Points Of Dak Bungalow Aharbal, Part C: Lighting/ Illumination Works { Supply, Installation And Commissioning Of Led Flood Lights At Tourist Office Aharbal} ]
Basic Detail
Tender No NIT No.74//2026-27 Dt/10/07/2026
Bidding Type Tender
Location
City Kulgam
State Jammu and Kashmir
Key Dates
Publish Date 10 Jul 2026
Submission Date 24 Jul 2026
Open Date 25 Jul 2026
Finance
Tender Value 11.23 Lakhs
Tender Fee 600
EMD 22475
Exemption Not Available
Document List
0681eb0e-0766-4291-b70f-a7027ab88497.html
BOQ_1022955.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Jul 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

0681eb0e-0766-4291-b70f-a7027ab88497.html

xls

BOQ_1022955.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders