Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #56411185

Tender For Providing Of Swimming Pool At Abhor

Issued by Statutory Bodies & Commissions/Committees · Fazilka, Punjab
Tender Value
13.94 Crore
Estimated cost
Bid Submission
31 Jul 2026
20 days left
EMD
10.22 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Fazilka → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Providing Of Swimming Pool At Abhor

BOQ

Name of Work:- PROVN OF SWIMMING POOL AT ABHOR
Sl. No. Item Description
1Lump sum price worked out by the tenderer for “BUILDING WORK\\" as listed in Schedule ‘A’ Part - I
2Subtotal
3Lump sum price worked out by the tenderer for “ EARTH WORKS AND SITE CLEARANCE\\" as listed in Schedule ‘A’ Part -II
4Subtotal
5Lump sum price worked out by the tenderer for “ROAD, PATH & CULVERTS\\" as listed in Schedule ‘A’ Part - III
6Subtotal
7Lump sum price worked out by the tenderer for “AREA DRAINAGE WORKS\\" as listed in Schedule ‘A’ Part - IV
8Subtotal
9Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS\\" as listed in Schedule ‘A’ Part -V
10Subtotal
11Lump sum price worked out by the tenderer for “COMPOUND WALL, SECURITY WALL & GATE WORKS\\" as listed in Schedule ‘A’ Part -VI
12Subtotal
13Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS\\" as listed in Schedule ‘A’ Part -VII
14Subtotal
15Lump sum price worked out by the tenderer for “SUMMER APPLIANCES WORKS\\" as listed in Schedule ‘A’ Part -VIII
16Subtotal
17Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIC SUPPLY\\" as listed in Schedule ‘A’ Part -IX
18Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION SUPPLY WORKS\\" as listed in Schedule ‘A’ Part -X
19Subtotal
20Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS\\" as listed in Schedule ‘A’ Part -XI
21Subtotal
22Schedule ‘A’ Part -XII MISCELLANEOUS WORKS
23Supply of vertical fibre glass filter of 2.00M dia made of polyester shell with a liner employing special version with polypropylene arm collector, and PVC distribution network with a net filtering area of 3.14Sq.m capable of filtering @123000Ltr / hr / at 40000Ltrs / Sq.mt/ hr of filter bed area with inlet & outlet opening of 160mm dia flange. as per standard design for the efficient working of the system complete with first charge of the filter media. ( out let size cannot be lesser than 125mm dia)
24Supply of Grade 1 sand Media 50kg in bags
25Supply of Valve batteries made in Zinc plated steel, consisting of 5 Nos, 160mm dia PVC butterfly Valve, suitable mounting supports, pressure gauge with required size inlet. outlet, flanges & 2 support brackets with suitable clamps & fixing screws. ( valve size cannot be lesser than 125mm dia & respeCtive piping)
26Supply of Centrifugal self-priming pump with high hydraulic efficiency, chemical resistant and ultra-quiet operation. Integrated along with IP-55 protection- class F continuous rating high efficiency IE3 motors. Pump shall be of two-piece body made in polypropylene 30%+ GF, integrated polypropylene 30% + GF pre-filter with strainer basket, fast opening translucent transparent polycarbonate lid, easy opening metal knob lid system, 316 SS Shaft and mechanical seal. Bronze impeller, flanged end connections 125mm suction & 100mm return union connections, Horse power: 10 HP,7.5 Kw, Phase: III phase 400V, FLOW CONDITIONS =125m³/hr @ 13 m water head. with 5 year warranty ( MAXIMUM POWER CANNOT BE MORE THAN 10HP & IT MUST BE IE3 MOTORS)
27Supplying of manual chlorine dosing system 20LPH @ 5 BAR with pH controller and necessary pumps, along with 500 LTR mixing tanks and 900MM manual agitators
28Supply of Commercial VGE UV system Model VGE pro 600-219 is designed to work at Medium pressure capable to dose UV at a rate of 400J/m2. The unit shall be made of SS316L body with U shape irradiation reactor chamber with 6 BAR maximum pressure rating. The unit shall be capable to work around 140 cumtr/ hr flow with a 125mm connection. The unit shall used AOP , Advanced oxidation processes . The UV comes with control panel and monitor with sensors to check UV & temperature. The units UV Lamp shall be placed to perpendicular to the direction of flow. The Lamp base shall be equipped with SMART PIN TECHNOLOGY where the lamp shall be removed when the system is pressurised. The UV lamp expected life time shall be 16000 hrs. The end connections shall be of 125mm dia SS flanges. .( Multiple qty of residential not allowed)
29PIPES , VALVES & CABLE QUANTITY\\"Supply of UPVC 10 kg/sqcm Piping including necessary fitting such as Elbows, Bends, Sockets, Tees, Collars, Nipples, Reducers, Stub Ends, diminishing pieces, Solvent Cement, etc. for Swimming Pool Inlet & Drain & Suction piping, Swimming Pool filtration plant piping, drain pipe along the pipe periphery including all fittings, fixtures and Ceiling/ Wall Support System suitable for following uPVC pipe as specified and directed. \\"
30a) 315mm dia - 10Kg pipe
31b) 250mm dia - 10Kg pipe
32c) 200mm dia - 10Kg pipe
33d) 160mm dia - 10Kg pipe
34e) 63 mm dia - 10Kg pipe
35Supply only evaporative air coolers (desert coolers) as per IS 3315:2019 sump tank capacity not less than 80 liters, single phase having air flow capacity 4000 cum per hrs, cooling efficiency not less than 65 %, maximum power consumption 300 watts, plastic body, noise level not more than 65dBA at 1 m distance, honeycomb pads complete all as specified and directed.
36Supply, install, commissioning of refrigerator electric driven single phase capacity up to 330 litres direct cool, single door, BEE 5 star rated with AI auto defrost rapid freeze technology, stablizer free operation, inverter compressor, on door digital control panel, copper condenser and evaporator latest technology complete all as specified and directed by Engineer-in-Charge. Make: Lloyd, LG, Godrej.
37Supply of Air cooled Heat Pump delivering actual capacity as per the following parameters. Heat pump shall be rated at Nominal Input Power -2000 Watt with Output Heating capacity - 6 KW,Electrical Backup - 2.2 KW having Inbuilt Tank capacity - 450 litres having glass lining. Water Temp in efficiency mode using compressor should be 65 degree C. Heat pump should have all the safety protections like high/low voltage , high temperature, refrigeratnt leak, compressor overheting protection with operational noise level not more than 60 dbA. Heat pump should have a user freindly control panel to set the desired temperature showcasing the actual temp
38Supply install test and commisioning of Pool under water integral LED model 14.4 Watt, wall mounted type working on 12 V DC, IP68 complete with built-in driver, including push in connector in 4 pole, flexible conduit and all fixing arrangement in swimming pool wall including and flexible conduit accommodate pool light .
39Supply install test and commisioning ofJunction box of suitable size round/square type with water proof covering made of ABS plastic material.
40Supply, and lay in conduit, under floor, on wall, of 2 core 2.5 sq.mm. PVC insulated FRLSH copper conductor 1100 Grade unarmoured cable Wiring from under water lights to distribution panel all as directed and specified by Engineer-in-Charge.
41Supply, installation, testing and commissioning of heavy duty PVC conduit 20 mm PVC, ISI marked conduits complete with accessories such as bends, junction boxes, pull boxes etc.
42Supply, installation, testing and commissioning of water proof Distribution box for under water lights drivers and MCB all as directed and specified by Engineer-in-Charge.
43Supply and fix galvanised stay strand wire 7/4mm suitable for staying of poles including Stay assembly complete withaccessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete etc are including in this items ) complete all as specified and directed .
44Supply and laying double wall corrugated pipe (DWCP), Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating, conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable complete all as specified and directed by Engr - in charge
45DWC Pipe dia 77/63
46DWC Pipe dia 120/103
47Supply, installation, testing and commissioning outdoor type Compact Sub – Station (CSS) comprising 11KV, 630 Amp VCB, 100KVA Copper Wound Oil Cooled Off Circuit Transformer & LT Panel with base and trenches for cable with cover by use suitable material PCC, plaster and bricks Complete all as specified and as directed including the following:-(a) HT Section:- (i) 11 kV, 630 Amp, Indoor Type, VCB Horizontal Draw out Horizontal isolation floor mounting motorized panel with 230v motor mechanism & 24v DC Shunt/Close coil with CT, PT, IDMT Relay, 8 Window Enunciator Model No. SI-801, Battery Power Pack with 7AH Battery & in built charger for 24V Circuit and other fittings & accessories. Nos 01.(ii) Potential Transformer – 3 Phase cast resin of ratio 11kV/110V, Class-0.5, 100VA with HT Primary Fuses. (Nos 03).(iii) Current Transformer –Cast resin Ratio: 60-30/5+5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10, 15VA (Nos 01)(iv) Protection :- Numerical 2OC + 1EF Relay and Auxiliary Relay. (Set one)(v) Micro Processed based Non-Directional IDMT. (Nos 01)(vi) Indication Lamps:- VCB off / on / auto trip/ Trip circuit healthy/spring charge indication (set one)(vii) Metering:- Digital Ammeter & Digital Volt Meter (Set one)(b) Transformer Section:- Transformer 100 KVA, 11/0.433 KV, 3 Phase, 50HZ, ONAN Cooled Oil immersed Copper Wound Step Down “BIS Marked” Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI & Marshalling Box. Transformer as per IS-1180:2014 EEL- 2 with amendment no.- 1,2,3 & 4 Formerly EEL- 3 (till 30.3.2022) Losses @50% Load - 955W Losses @100% Load - 2750W (c) LT Section:- LT Panel comprising of LV Side Incomer – 01 no. -300 Amp 4 Pole 415V 25 KA MCCB with thermal magnetic based release with O/L & S/C protection. - RYB Indication
48(d) Enclosure Section(i) Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control(ii) MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel.(iii) Provision for receiving Incoming cables thro Bottom entry and out going(iv) through Bus bar to Trf panel, Excluding Termination Kit & Glands(v) Provision for receiving Incoming through bus duct by bus bar and Outgoing thro cable box bottom entry Excluding Termination Kit & Glands(vi) Bus Bar – Aluminum(vii) Earth Bus – Aluminum(viii) Paint shade: Siemens Grey ( RAL 7032)(ix) provn of platform for mounting CSS as per given size rate to be deemed in BOQ rate of this item.
49Supply and install galvanized steel High Mast of 16Mtrs height lighting system in two section, 3 mm section thickness, top dia not less than 150mm & bottom dia not less than 340mm with its accessories including foundation bolts manufactured from special steel and Hopt Dip galvanised along with nuts, washers, anchor plates and templates, feeder pillar panel control and raising 7lowering mechanism for integralpower tool, Twin aviation lamp etc. mast shaft shall be in two sections, hot dip galvanized and suitable for wind velocity as per IS 875 part 3 minimum 18 per hour. It shall also include accessories for high mast including mast including head frame, steel wir rope (7/19 construction) double frum is operated by motor gear mechanism with inbuilt starter, timer and feeder piller panel, galvanized lantern carriage arrangement suitable for 08 Nos, liminaires Symmertrically & its control gear boxes and with 03 point suspension system. the mast shall have an integral power tool installed inside the base compartment for its operation. (material construction of high mast sheet will be BESEN 10025/ IS 5986 or eqivalent) with wiring cable for luminaire connection including suitable size of foundation for 16.0 mtr high mast considering the soil bearing capacity 10 T/sq mtr at 2 meter depth and using RCC M-25 grade (design mix) concrete with reinforcement, from work, earthwork complete all as per manufacturers instructions and as directed by Eng-in-charge.Note:(a) making of civil foundation for erection of high mast and feeder pillar panel as per manufacturer recommendation demeed to be including in the unit rate. (b) Cable of required size and lenght from top to bottom for connection og LED flood light an related switchgears including quoated rate.
50Supply, Install, testing & commissioning factory made Out door type dust and vermin proof Feeder pillar LT panel board cubical double door hinged type compartmentalized of suitable size 415 volts, AC 50 Hz fabricated of CRCA sheet 3 mm thick machine pressed and angle iron frame 50mm x 50mmx 6mm grouted in PCC 1:2:4 type B1 (20mm grade stone aggregated) powder coated inside and outside complete including 4 poles aluminium bus bar of suitable size mouned on porcelain insulators and enclosed in chamber made out od 2mm thick CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles / lugs cable gland with open able shutters on both side and comprising of the following :-
51(i) in comming MCCB 200 Amp, 50 KA, 4 Pole 415 Volt - 01 Nos
52(ii) Out going MCCB 120 Amp, 36 KA 4 Pole 415 Volt, - 01 Nos
53(iii) Out going MCCB 63 Amp, 36 KA 4 Pole 415 Volt, - 01 Nos
54(iv) out going MCCB 32 Amp 4 pole 415 volt 10 KA - 03 Nos
55(v) Timer
56(vi) Aluminium bus bar for 3 Ph & Neutral 300 Amp- 01 Set
57(vii) Volt meter 0-500V
58(viii) Ammeter with CTs 50 A rang and selector switch
59(ix) Phase indicator lamps for 3 Ph -01 Set
60Supplying, fixing,testing,& commissioning intergal decorative Water proof 9 Watt LED bollard light with opal acrylic with IP-65 protection with inbuilt driver, colour temperature of 5700 K of graphite grey powder coated finish type including PCC base with specified size complete all as specified and directed by Engr-in-Charge.
61S&F Post top lantern Light of not less than 20 Watt capacity made of housing epoxy powder coated pressure die cast aluminium spigot and lid cover with graphite grey finish and clear acrylic cover, IP65 protction, including suitable mounting GI pipe to be fitted into the column / piller with all fitting and wiring and PCC grouting complete all as specified and directed
62M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
63M&L for making coonection from existing water pipe line 200 mm bore and inserting of flanged Tee 200x200x150 mm with flanged socket 200 mm and jointing with rubber gasket, nut bolt etc. and making leak proof joint complete and making new connection with 200 mm HDPE water pipe line.Note:- Rate encludes the cost of cuttings of pipe, jointing of pipe and jointing material i.e. rubber gaskets, nut bolts, washer etc, and HDPE special fittings as required complete.
64M&L for Construction of brick masonry valve pit of internal size 120cm x 120cm x 120 cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock, complete all as specified and directed by Engineer - in - Charge Note :-(i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds.(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B-1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Two coats of white wash to internal surfaces of valve pit.(vi) Depth of wall pit shall be reckoned from the top of PCC in foundation.
65Providing laying Granular Base (GSB) 150mm thick of Grade V of table 400-2 of MORTH, IRC specification of layer not exe 150mm thick obtained from outside MD land by using mechanical Paver and roller necessary form work, finishing, spreading , grading levelling and rolling etc complete all as directed and as specified (Physical properities, procedure for spreading and compaction shall be considered and excuted as mentioned in section 400 sub clause 401.7 of MORTH, IRC specification /TI 09/2018.
66Provinding laying 150mm thick (Compacted thickness) Wet Mix macadam (WMM) in two layers 150 and 100mm thick compacted seperately with crushed stone agg of specified grading spread using mechanical paver as specified rolled and consolidated as specifed to reqd gradient and camber complete all as spd and as directed. Please Enable Macros to View BoQ information
67Provinding laying 150mm thick (Compacted thickness) Wet Mix macadam (WMM) in two layers 150 and 100mm thick compacted seperately with crushed stone agg of specified grading spread using mechanical paver as specified rolled and consolidated as specifed to reqd gradient and camber complete all as spd and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56411185
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 13.94 Crore
LAST DATE 31-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Swimming Pool At Abhor
Basic Detail
Tender No 84590
Bidding Type Tender
Location
City Fazilka
State Punjab
Key Dates
Publish Date 10 Jul 2026
Submission Date 31 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value 13.94 Crore
Tender Fee 3000
EMD 10.22 Lakhs
Exemption Available
Document List
51aa71ce-459f-4ee6-891c-4449ff7c7a72.html
BOQ_870952.xls
Tendernotice_1 (5).pdf
Finaltender.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

51aa71ce-459f-4ee6-891c-4449ff7c7a72.html

xls

BOQ_870952.xls

pdf

Tendernotice_1 (5).pdf

pdf

Finaltender.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders