Tender For Repair And Replacement Of Sewage Line, Cleaning Of Septic Tank, Man Hole, Soakage Well, Approch Path, Misc Works For Zone I A Under Age (I) Nyoma.
Tender Value
9.99 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
17 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
nyoma → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repair And Replacement Of Sewage Line, Cleaning Of Septic Tank, Man Hole, Soakage Well, Approch Path, Misc Works For Zone I A Under Age (I) Nyoma.
BOQ
| Sl. No. | Item Description |
| 1 | Cleaning/clearing of manhole of any description and any size and removing sludge and accumulated solid/semi solids with proper equipment and washing down with water for smooth functioning of sewage line and manhole all as specified and directed. Waste obtained shall be removed to a distance exceeding 250 M away from unit lines and burried in ground including necessary excavation, earth work and spreading of bleaching powder, Complete all as specified and as directed by Engr-in-charge. |
| 2 | Cleaning / clearing of blocked WC / EWC of any type and description including removal of soil, waste and vent pipes by using rubber cup 125mm dia with wooden handle, rodding or with gunny bags and clearing the blockage upto 1st manhole with cleaning rod including removal of all materials from traps of WC, Complete all as specified and as directed by Engr-in-charge. |
| 3 | Cleaning / Clearing of Nahani traps, floor traps and gully traps of any description, any size any depth and removing sludge and accumaulated solid / semi solis with proper equipment and washing down with water for smooth functioning of sewage line, nahani traps and floor traps all as specified and directed. Waste obtained shall be removed to a distance exceeding 250m away from unit lines and burried in ground including necessary excavation, earth work and spreading of bleaching powder, Complete all as specified and as directed by Engr-in-charge. |
| 4 | Cleaning / desludging of existing septic tank of 10 to 50 users and any depth including taking out and removing sludge and accumulated solids / semi solid contents in closed container at a place 250 m away from defence land and burried in ground including necessary excavation, earth work and spreading of spreading of bleaching powder complete all as specified and as directed.Note :- (i) The cleaning of septic tank shall be carried out mechanically using apropriate technological appliances. Complete all as specified and as directed by Engr-in-charge. |
| 5 | Cleaning of existing sewer lines of dia 100 to 200 mm, any depth not exceeding 2.50 m deep by rodding manually or mechanically as required at site including manholes, inspection chamber, testinig after cleaning and getting out sludge and accumulated solids / semi solids from connecting manholes / lines, removing the sludge / spoil minimum 250 mtrs away from MOD land and refixing the manhole cover etc, Complete all as specified and as directed by Engr-in-charge. |
| 6 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, manholes etc not exceeding 10 sqm on plan and getting out in hard/dense soil, Complete all as specified and as directed by Engr-in-charge. |
| 7 | Demolition and breaking up drain pipes , 100/110 mm dia (PVC / Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar or fixed with wall, Complete all as specified and as directed by Engr-in-charge. |
| 8 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil of any description, complete all as specified and as directed by Engr-in-charge. |
| 9 | Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed by Engr-in-charge. |
| 10 | M&L for PCC 1:4:8 type D-2, (Using 20 mm graded stone aggregate) as in bed of drain for 150mm bore pipe incl packing under and haunching against the sides of pipes after they are laid in and tested, complete all as specified and as directed by Engr-in-charge. |
| 11 | S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in floor, or in trenches, complete all as specified and as directed by Engr-in-charge. |
| 12 | S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, fixed on walls or floors and spout pipe of retaining wall including taking down old pipes, complete all as specified and as directed by Engr-in-charge. |
| 13 | S&F PVC (SWR) pipes75mm dia single socketed, in any length with rubber ring joints, laid in floors including taking down old pipes, complete all as specified and as directed by Engr-in-charge. |
| 14 | S&F PVC (SWR) pipes75mm dia single socketed, in any length with rubber ring joints, fixed to wall including taking down old pipes, complete all as specified and as directed by Engr-in-charge. |
| 15 | S&F in repair PVC (SWR) vent cowl 75mm dia pipe, complete all as specified and as directed by Engr-in-charge. |
| 16 | Demolition of reinforced cement concrete cover slab for manhole /spetic tank and removing the debris to a distance not exc 500 M, complete all as specified and as directed by Engr-in-charge. |
| 17 | M & L Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate for cover slab for Man holes/Septic tank set in CM 1:4, complete all as specified and as directed by Engr-in-charge. |
| 18 | M&L for mild steel deformed bars or TMT bars10mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and as directed by Engr-in-charge. |
| 19 | Demolition of PCC block masonary, stone /boulder masonry, built in any type of cement mortar including all quoins, arches, pillars, etc., but including ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engr-in-charge. |
| 20 | M & L for Precast cement concrete 1:3:6 type C-1, (20mm graded crushed stone aggregate) block masonary with solid blocks built in cement mortar 1:6, complete all as specified and as directed by Engr-in-charge. |
| 21 | M&L PCC 1:2:4 type B-1 using 20mm graded stone agg as in coping to retaining wall / drains / manholes, complete all as specified and as directed by Engr-in-charge. |
| 22 | M & L rendering 15mm thick on fair faces of stone/concrete work in CM 1:4 incl finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-charge. |
| 23 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced), complete all as specified and as directed by Engr-in-charge. |
| 24 | M&L for providing cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundations, mass concrete and filling, complete all as specified and as directed by Engr-in-charge. |
| 25 | M&L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair, complete all as specified and as directed by Engr-in-charge. |
| 26 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engr-in-charge. |
| 27 | M&L for chequered cement concrete tiles 25 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors, complete all as specified and as directed by Engr-in-charge. |
| 28 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar,complete all as specified and as directed by Engr-in-charge. |
| 29 | M&L for Sand filling under floors or in foundations including watering and consolidation, complete all as specified and as directed by Engr-in-charge. |
| 30 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with gray cement and pigment, complete all as specified and as directed by Engr-in-charge. |
| 31 | M & L for providing, cement concrete Type B-1, 1:2:4 (20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender