Bids Are invited for Custom Bid For Services - Structural Repairs And Rehabilitation Works Of Residential Structure Of New Airport Colony, Mumbai, Phase-Ii (2026-27) - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.
Tender Overview
Project Description
Bids Are invited for Custom Bid For Services - Structural Repairs And Rehabilitation Works Of Residential Structure Of New Airport Colony, Mumbai, Phase-Ii (2026-27) - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Gruoup A , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Medium Class Pvc Conduit As Required. 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Medium Class Pvc Conduit As Required.2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Medium Class Pvc Conduit As Required.2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Fixing Following Modular Switchon The Existing Modular Plate & Switch Box Includingconnections But Excluding Modular Plate Etc. Asrequired.5/6 A Switch , Supplying And Fixing Following Modular Switchon The Existing Modular Plate & Switch Box Includingconnections But Excluding Modular Plate Etc. Asrequired.15/16 A Switch , Supplying And Fixing Following Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required.3 Pin 5/6 A Socket Outlet , Supplying And Fixing Following Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required. 6 Pin 15/16 A Socket Outlet , Supplying And Fixing Following On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Following Size/ Modules, Gi Boxalong With Modular Base & Cover Plate For Modularswitches In Recess Etc. As Required.1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modularswitches In Recess Etc. As Required.3 Module (100Mm X 75Mm) , Supply & Installation Of Ding Dong Bell Suitable For 230A , 1 Phase Power Supply. , Supply & Installtion Of Meter Box With Viewing Glass Suitable For 1 / 3 Phase Electrical Energy Meter Installation On Wall With Accessories Etc. As Required. , Supplying And Fixing Pvc Batten/ Angle Holderincluding Connections Etc. As Required. , Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) Upto 12 Way, Double Door(Upto 12 Way, Double Door Mcb Distribution Board To Be Provided By Aai) , Fixing Following Rating, Double Pole, 240 Volts, Mcb In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Upto 40 A Double Pole( Upto 40 A Double Pole Mcb To Be Provided By Aai) , Fixing 6 S To 32 Rmps Rating, 240 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Follcwing Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole(Single Pole, 6 S To 32 S Rating Mcb To Be Provided By Aai) , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supply Of 1 X 20W Led Tube Light Fixture With Suitable L Suitable To Operate On Single Phase, 230 V, 50 Hz A.C Supply Etc Complete As Required. , Supply Of 1 X 9W Led L Suitable To Operate On Single Phase, 230 V, 50 Hz A.C Supply Etc Complete As Required. , Installation, Testing And Commissioning Of Pre-Wired,Fluorescent Fitting / Compact Fluorescent/ Led Fitting Of All Types, Complete With All Accessories And Tube/L Etc. Directly On Ceiling/ Wall, Including Connections With 1.5 Sq. Mm Frls/Hffr Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. Asrequired. , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mmdia Including Accessories And Providing Masonryenclosure With Cover Plate Having Lockingarrangement And Watering Pipe Etc. With Charcoal/Coke And Salt As Required. , Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50Metre Below Ground As Strip Earth Electrode, Ncluding Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm)
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Gruoup A | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Gruoup A |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 5 | Supplying and fixing following modular switchon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired.5/6 A switch | Supplying and fixing following modular switchon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired.5/6 A switch |
| 6 | Supplying and fixing following modular switchon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired.15/16 A switch | Supplying and fixing following modular switchon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired.15/16 A switch |
| 7 | Supplying and fixing following socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outlet | Supplying and fixing following socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outlet |
| 8 | Supplying and fixing following socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet | Supplying and fixing following socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet |
| 9 | Supplying and fixing following on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push | Supplying and fixing following on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push |
| 10 | Supplying and fixing following size/ modules, GI boxalong with modular base & cover plate for modularswitches in recess etc. as required.1 or 2 Module (75mmX75mm) | Supplying and fixing following size/ modules, GI boxalong with modular base & cover plate for modularswitches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 11 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modularswitches in recess etc. as required.3 Module (100mm X 75mm) | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modularswitches in recess etc. as required.3 Module (100mm X 75mm) |
| 12 | Supply & Installation of Ding Dong Bell suitable for 230A , 1 phase power supply. | Supply & Installation of Ding Dong Bell suitable for 230A , 1 phase power supply. |
| 13 | Supply & Installtion of Meter Box with viewing glass suitable for 1 / 3 phase electrical energy meter installation on wall with accessories etc. as required. | Supply & Installtion of Meter Box with viewing glass suitable for 1 / 3 phase electrical energy meter installation on wall with accessories etc. as required. |
| 14 | Supplying and fixing PVC batten/ angle holderincluding connections etc. as required. | Supplying and fixing PVC batten/ angle holderincluding connections etc. as required. |
| 15 | Fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) upto 12 way, Double door(upto 12 way, Double door MCB distribution board to be provided by AAI) | Fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) upto 12 way, Double door(upto 12 way, Double door MCB distribution board to be provided by AAI) |
| 16 | Fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Upto 40 A Double Pole( upto 40 A Double Pole MCB to be provided by AAI) | Fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Upto 40 A Double Pole( upto 40 A Double Pole MCB to be provided by AAI) |
| 17 | Fixing 6 amps to 32 rmps rating, 240 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of follcwing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single Pole(Single Pole, 6 amps to 32 amps rating MCB to be provided by AAI) | Fixing 6 amps to 32 rmps rating, 240 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of follcwing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single Pole(Single Pole, 6 amps to 32 amps rating MCB to be provided by AAI) |
| 18 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 19 | Supply of 1 X 20W LED tube light fixture with suitable lamp suitable to operate on single phase, 230 V, 50 Hz A.C supply etc complete as required. | Supply of 1 X 20W LED tube light fixture with suitable lamp suitable to operate on single phase, 230 V, 50 Hz A.C supply etc complete as required. |
| 20 | Supply of 1 X 9W LED lamp suitable to operate on single phase, 230 V, 50 Hz A.C supply etc complete as required. | Supply of 1 X 9W LED lamp suitable to operate on single phase, 230 V, 50 Hz A.C supply etc complete as required. |
| 21 | Installation, Testing and Commissioning of pre-wired,fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. asrequired. | Installation, Testing and Commissioning of pre-wired,fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. asrequired. |
| 22 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mmdia including accessories and providing masonryenclosure with cover plate having lockingarrangement and watering pipe etc. with charcoal/coke and salt as required. | Earthing with G.I. earth pipe 4.5 Meter long, 40 mmdia including accessories and providing masonryenclosure with cover plate having lockingarrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 23 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50metre below ground as strip earth electrode, ncluding connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | Supplying and laying 25 mm X 5 mm G.I strip at 0.50metre below ground as strip earth electrode, ncluding connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender