Civil Aviation Boards / Undertakings / PSU Closing in 8 days TDR #56409361

Bids Are invited for Custom Bid For Services - Structural Repairs And Rehabilitation Works Of Residential Structure Of New Airport Colony, Mumbai, Phase-Ii (2026-27) - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.

Issued by Boards / Undertakings / PSU · Mumbai Suburban, Maharashtra
Tender Value
38.31 Lakhs
Estimated cost
Bid Submission
31 Jul 2026
8 days left
EMD
1.14 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Bids Are invited for Custom Bid For Services - Structural Repairs And Rehabilitation Works Of Residential Structure Of New Airport Colony, Mumbai, Phase-Ii (2026-27) - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Gruoup A , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Medium Class Pvc Conduit As Required. 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Medium Class Pvc Conduit As Required.2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Medium Class Pvc Conduit As Required.2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Fixing Following Modular Switchon The Existing Modular Plate & Switch Box Includingconnections But Excluding Modular Plate Etc. Asrequired.5/6 A Switch , Supplying And Fixing Following Modular Switchon The Existing Modular Plate & Switch Box Includingconnections But Excluding Modular Plate Etc. Asrequired.15/16 A Switch , Supplying And Fixing Following Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required.3 Pin 5/6 A Socket Outlet , Supplying And Fixing Following Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required. 6 Pin 15/16 A Socket Outlet , Supplying And Fixing Following On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Following Size/ Modules, Gi Boxalong With Modular Base & Cover Plate For Modularswitches In Recess Etc. As Required.1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modularswitches In Recess Etc. As Required.3 Module (100Mm X 75Mm) , Supply & Installation Of Ding Dong Bell Suitable For 230A , 1 Phase Power Supply. , Supply & Installtion Of Meter Box With Viewing Glass Suitable For 1 / 3 Phase Electrical Energy Meter Installation On Wall With Accessories Etc. As Required. , Supplying And Fixing Pvc Batten/ Angle Holderincluding Connections Etc. As Required. , Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) Upto 12 Way, Double Door(Upto 12 Way, Double Door Mcb Distribution Board To Be Provided By Aai) , Fixing Following Rating, Double Pole, 240 Volts, Mcb In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Upto 40 A Double Pole( Upto 40 A Double Pole Mcb To Be Provided By Aai) , Fixing 6 S To 32 Rmps Rating, 240 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Follcwing Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole(Single Pole, 6 S To 32 S Rating Mcb To Be Provided By Aai) , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supply Of 1 X 20W Led Tube Light Fixture With Suitable L Suitable To Operate On Single Phase, 230 V, 50 Hz A.C Supply Etc Complete As Required. , Supply Of 1 X 9W Led L Suitable To Operate On Single Phase, 230 V, 50 Hz A.C Supply Etc Complete As Required. , Installation, Testing And Commissioning Of Pre-Wired,Fluorescent Fitting / Compact Fluorescent/ Led Fitting Of All Types, Complete With All Accessories And Tube/L Etc. Directly On Ceiling/ Wall, Including Connections With 1.5 Sq. Mm Frls/Hffr Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. Asrequired. , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mmdia Including Accessories And Providing Masonryenclosure With Cover Plate Having Lockingarrangement And Watering Pipe Etc. With Charcoal/Coke And Salt As Required. , Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50Metre Below Ground As Strip Earth Electrode, Ncluding Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm)

BOQ

Sl. No. Item TitleItem Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Gruoup AWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Gruoup A
2Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireWiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wireWiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wireWiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
5Supplying and fixing following modular switchon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired.5/6 A switchSupplying and fixing following modular switchon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired.5/6 A switch
6Supplying and fixing following modular switchon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired.15/16 A switchSupplying and fixing following modular switchon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired.15/16 A switch
7Supplying and fixing following socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outletSupplying and fixing following socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outlet
8Supplying and fixing following socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outletSupplying and fixing following socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet
9Supplying and fixing following on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell pushSupplying and fixing following on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
10Supplying and fixing following size/ modules, GI boxalong with modular base & cover plate for modularswitches in recess etc. as required.1 or 2 Module (75mmX75mm)Supplying and fixing following size/ modules, GI boxalong with modular base & cover plate for modularswitches in recess etc. as required.1 or 2 Module (75mmX75mm)
11Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modularswitches in recess etc. as required.3 Module (100mm X 75mm)Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modularswitches in recess etc. as required.3 Module (100mm X 75mm)
12Supply & Installation of Ding Dong Bell suitable for 230A , 1 phase power supply.Supply & Installation of Ding Dong Bell suitable for 230A , 1 phase power supply.
13Supply & Installtion of Meter Box with viewing glass suitable for 1 / 3 phase electrical energy meter installation on wall with accessories etc. as required.Supply & Installtion of Meter Box with viewing glass suitable for 1 / 3 phase electrical energy meter installation on wall with accessories etc. as required.
14Supplying and fixing PVC batten/ angle holderincluding connections etc. as required.Supplying and fixing PVC batten/ angle holderincluding connections etc. as required.
15Fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) upto 12 way, Double door(upto 12 way, Double door MCB distribution board to be provided by AAI)Fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) upto 12 way, Double door(upto 12 way, Double door MCB distribution board to be provided by AAI)
16Fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Upto 40 A Double Pole( upto 40 A Double Pole MCB to be provided by AAI)Fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Upto 40 A Double Pole( upto 40 A Double Pole MCB to be provided by AAI)
17Fixing 6 amps to 32 rmps rating, 240 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of follcwing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single Pole(Single Pole, 6 amps to 32 amps rating MCB to be provided by AAI)Fixing 6 amps to 32 rmps rating, 240 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of follcwing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single Pole(Single Pole, 6 amps to 32 amps rating MCB to be provided by AAI)
18Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
19Supply of 1 X 20W LED tube light fixture with suitable lamp suitable to operate on single phase, 230 V, 50 Hz A.C supply etc complete as required.Supply of 1 X 20W LED tube light fixture with suitable lamp suitable to operate on single phase, 230 V, 50 Hz A.C supply etc complete as required.
20Supply of 1 X 9W LED lamp suitable to operate on single phase, 230 V, 50 Hz A.C supply etc complete as required.Supply of 1 X 9W LED lamp suitable to operate on single phase, 230 V, 50 Hz A.C supply etc complete as required.
21Installation, Testing and Commissioning of pre-wired,fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. asrequired.Installation, Testing and Commissioning of pre-wired,fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. asrequired.
22Earthing with G.I. earth pipe 4.5 Meter long, 40 mmdia including accessories and providing masonryenclosure with cover plate having lockingarrangement and watering pipe etc. with charcoal/coke and salt as required.Earthing with G.I. earth pipe 4.5 Meter long, 40 mmdia including accessories and providing masonryenclosure with cover plate having lockingarrangement and watering pipe etc. with charcoal/coke and salt as required.
23Supplying and laying 25 mm X 5 mm G.I strip at 0.50metre below ground as strip earth electrode, ncluding connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)Supplying and laying 25 mm X 5 mm G.I strip at 0.50metre below ground as strip earth electrode, ncluding connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

AI Tender Summary

OUR REF NO 56409361
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 38.31 Lakhs
LAST DATE 31-07-2026
Authority
Authority Name Airports Authority Of India
Work Description Bids Are invited for Custom Bid For Services - Structural Repairs And Rehabilitation Works Of Residential Structure Of New Airport Colony, Mumbai, Phase-Ii (2026-27) - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Gruoup A , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Medium Class Pvc Conduit As Required. 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Medium Class Pvc Conduit As Required.2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Medium Class Pvc Conduit As Required.2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Fixing Following Modular Switchon The Existing Modular Plate & Switch Box Includingconnections But Excluding Modular Plate Etc. Asrequired.5/6 A Switch , Supplying And Fixing Following Modular Switchon The Existing Modular Plate & Switch Box Includingconnections But Excluding Modular Plate Etc. Asrequired.15/16 A Switch , Supplying And Fixing Following Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required.3 Pin 5/6 A Socket Outlet , Supplying And Fixing Following Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required. 6 Pin 15/16 A Socket Outlet , Supplying And Fixing Following On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Following Size/ Modules, Gi Boxalong With Modular Base & Cover Plate For Modularswitches In Recess Etc. As Required.1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modularswitches In Recess Etc. As Required.3 Module (100Mm X 75Mm) , Supply & Installation Of Ding Dong Bell Suitable For 230A , 1 Phase Power Supply. , Supply & Installtion Of Meter Box With Viewing Glass Suitable For 1 / 3 Phase Electrical Energy Meter Installation On Wall With Accessories Etc. As Required. , Supplying And Fixing Pvc Batten/ Angle Holderincluding Connections Etc. As Required. , Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) Upto 12 Way, Double Door(Upto 12 Way, Double Door Mcb Distribution Board To Be Provided By Aai) , Fixing Following Rating, Double Pole, 240 Volts, Mcb In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Upto 40 A Double Pole( Upto 40 A Double Pole Mcb To Be Provided By Aai) , Fixing 6 S To 32 Rmps Rating, 240 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Follcwing Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole(Single Pole, 6 S To 32 S Rating Mcb To Be Provided By Aai) , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supply Of 1 X 20W Led Tube Light Fixture With Suitable L Suitable To Operate On Single Phase, 230 V, 50 Hz A.C Supply Etc Complete As Required. , Supply Of 1 X 9W Led L Suitable To Operate On Single Phase, 230 V, 50 Hz A.C Supply Etc Complete As Required. , Installation, Testing And Commissioning Of Pre-Wired,Fluorescent Fitting / Compact Fluorescent/ Led Fitting Of All Types, Complete With All Accessories And Tube/L Etc. Directly On Ceiling/ Wall, Including Connections With 1.5 Sq. Mm Frls/Hffr Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. Asrequired. , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mmdia Including Accessories And Providing Masonryenclosure With Cover Plate Having Lockingarrangement And Watering Pipe Etc. With Charcoal/Coke And Salt As Required. , Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50Metre Below Ground As Strip Earth Electrode, Ncluding Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm)
Basic Detail
Tender No GEM/2026/B/7773537
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 10 Jul 2026
Submission Date 31 Jul 2026
Open Date 31 Jul 2026
Finance
Tender Value 38.31 Lakhs
Tender Fee Ref. Documents
EMD 1.14 Lakhs
Exemption Not Available
Document List
dc39b68c-a7bd-49e1-b6ac-01814f4a721c.pdf
1783687471.xlsx
1783687487.pdf
1783687499.pdf
1783687504.pdf
1783687509.pdf
1783687512.pdf
1783687514.pdf
1783687519.pdf
1783687528.pdf
1783687532.pdf
tendoc_64e07da6-ce24-45e8-acd41783687821166_engg-e-wr-3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Jul 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

dc39b68c-a7bd-49e1-b6ac-01814f4a721c.pdf

xlsx

1783687471.xlsx

pdf

1783687487.pdf

pdf

1783687499.pdf

pdf

1783687504.pdf

pdf

1783687509.pdf

pdf

1783687512.pdf

pdf

1783687514.pdf

pdf

1783687519.pdf

pdf

1783687528.pdf

pdf

1783687532.pdf

pdf

tendoc_64e07da6-ce24-45e8-acd41783687821166_engg-e-wr-3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders