Bids Are invited for Day To Day Breakdown Maintenance At Diff Sites Of Bed Muzaffarpur
Tender Overview
Project Description
Bids Are invited for Day To Day Breakdown Maintenance At Diff Sites Of Bed Muzaffarpur Attending To Break Down Calls For Power Supply Intrruption Of Exchange - Pdg Physical Inspection And Taking Corrective Measures For Restoration The Fault Etc , Replacement Of Faulty Lightening Arrestors - Suitable For 3 Wire 11 Kv Overhead Lines With Rated Voltage Etc As Reqd , Replacement Of Unserviceable Gang Operated Air Break Switch By New One - With Earthing Wire And Operating Handle Etc Complete As Reqd , Replacement Of Faulty 11Kv Outdoor Type Cable End Terminations - By New One Of Heat Shrinkable Type Complete With All Accessories , Supplying And Laying Of 30 Sqmm Acsr Weasel Conductor - With Interconnection Of All Insulators Gang Operator Air Break Switch Etc As Reqd , Replacement Of Faulty 63A Switch Fuse Unit - With 3 Nos Porcelain Fuse Links And Neutral Link Etc As Reqd , Replacement Of 63 Capacity Faulty Rewireable Prcelin Fuse Set - With Base By New One Etc Complete As Reqd , Replacement Of 100 Capacity Faulty Rewireable Prcelin Fuse Set - Complete With Base By New One Etc As Reqd , Replacement Of Faulty Damaged Pin Insulators By New One - With11 Kv Grade Pin Type Insulator Large Steel Head Etc Complete As Reqd , Replacement Of Faulty Damaged 11 Kv Disc Insulators - By New One For 11 Kv Overhead Lines With Galvanized Insulator Fittings Etc , Dismantling Different Ratings Faulty Transformer - From The Existing Dp Structure For Necessary Repairing , Refurbishmentburnt Burnt Out 16 Kva And 25Kva Al Wound Transformer - With Suitable Size Of Primary And Secondary Winding Wire Etc Complete As Reqd , Refurbishmentburnt Burnt Out 63 Kva Al Wound Transformer - With Suitable Capacity Of Primary And Secondary Winding Wire Etc Complete As Reqd , Refurbishmentburnt Burnt Out 63Kva Cu Wound Transformer - With Suitable Capacity Of Winding Wire Etc Complete As Reqd , To And Fro Transportation Charges For Spare Transformer - Suitable Capacity From Bsnl Office To Respective Sites Etc As Reqd , Supplying And Laying Of 3 Core 50 Sqmm Ab Cable Of 11 Kv - Capacity Along With Acsr Etc Complete As Reqd , Replacement Of Faulty Cables By New One Of 4 Core Lt - Aerial Bunched Aluminium Cable Of Size 25 Sq.Mm Etc Coplete As Reqd , Supplying Making Of End Termination For 4 Core Lt Ab - Aluminium Cable Of Size 25 Sq.Mm Of 1100 V Grade Etc Complete As Reqd Total Quantity : 1415
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Attending to break down calls for power supply intrruption of exchange | Pdg physical inspection and taking corrective measures for restoration the fault etc |
| 2 | Replacement of faulty lightening arrestors | Suitable for 3 wire 11 kV overhead lines with rated voltage etc as reqd |
| 3 | Replacement of unserviceable gang operated air break switch by new one | With earthing wire and operating handle etc complete as reqd |
| 4 | Replacement of faulty 11kv outdoor type cable end terminations | By new one of heat shrinkable type complete with all accessories |
| 5 | Supplying and laying of 30 sqmm acsr weasel conductor | With interconnection of all insulators gang operator air break switch etc as reqd |
| 6 | Replacement of faulty 63a Switch fuse Unit | With 3 nos porcelain fuse links and neutral link etc as reqd |
| 7 | Replacement of 63 amp capacity faulty rewireable prcelin fuse set | With base by new one etc complete as reqd |
| 8 | Replacement of 100 amp capacity faulty rewireable prcelin fuse set | Complete with base by new one etc as reqd |
| 9 | Replacement of faulty damaged pin insulators by new one | With11 kv grade pin type insulator large steel head etc complete as reqd |
| 10 | Replacement of faulty damaged 11 KV disc insulators | By new one for 11 kv overhead lines with galvanized insulator fittings etc |
| 11 | Dismantling different ratings faulty transformer | From the existing dp structure for necessary repairing |
| 12 | Refurbishmentburnt burnt out 16 kva and 25kva al wound transformer | With suitable size of primary and secondary winding wire etc complete as reqd |
| 13 | Refurbishmentburnt burnt out 63 kva al wound transformer | With suitable capacity of primary and secondary winding wire etc complete as reqd |
| 14 | Refurbishmentburnt burnt out 63kva cu wound transformer | With suitable capacity of winding wire etc complete as reqd |
| 15 | To and fro transportation charges for spare transformer | Suitable capacity from bsnl office to respective sites etc as reqd |
| 16 | Supplying and laying of 3 core 50 sqmm ab cable of 11 kv | Capacity along with acsr etc complete as reqd |
| 17 | Replacement of faulty cables by new one of 4 core lt | Aerial bunched aluminium Cable of size 25 sq.mm etc coplete as reqd |
| 18 | Supplying making of end termination for 4 core lt ab | Aluminium cable of size 25 sq.mm of 1100 V grade etc complete as reqd |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 23 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender