Tender For Construction Of Section Office Bulding For Rwss Section Koida Under Rourkela Division.
Tender Value
29.14 Lakhs
Estimated cost
Bid Submission
24 Jul 2026
12 days left
EMD
30000
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
rourkela → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Construction Of Section Office Bulding For Rwss Section Koida Under Rourkela Division.
BOQ
| Sl. No. | Item Description |
| 1 | Civil Work:- Earthwork in excavation of foundation in all kinds of soil within initial lead of 50m. and initial lift of 1.50m. etc. all complete as per the direction of Engineer-in-charge. |
| 2 | Supplying all labour, T&P and material for providing and filling sand in F&P including watering and ramming and conveyance of materials to work site as per the dirction of Engineer-in-charge. |
| 3 | Supplying all labour, T&P and material for Providing C.C. (1:3:6) using 4cm. size CBHG metal including watering, curing and conveyance of all materials to work site etc. complete as per the dirction of Engineer-in-charge. |
| 4 | Supplying all labour, T&P and material for Providing C.C. (1:1.5:3) using 12mm size CBHG chips for RCC works including watering, curing, hoisting, laying and conveyance of all materials to work site etc. complete as per the dirction of Engineer-in-charge. |
| 5 | Supplying all labour, T&P and material for Providing Fly ash Brick msonry work in cm (1:6) using 25x12x8 cm. size FA bricks inclduing watering, curing and conveyance of all materials to work site etc. complete as per the dirction of Engineer-in-charge.(a) Foundation & Plinth |
| 6 | 5. (b) Super Structure |
| 7 | Supplying all labour, T&P and material for Providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting etc. complete as per the dirction of Engineer-in-charge.(a) Base of Column |
| 8 | 7. (a) Lintel |
| 9 | 7. (b) Roof Slab & Chajja |
| 10 | 7.(c )Beam & Column |
| 11 | 7. (d) Stair Case |
| 12 | Supplying all labour, T&P and material for cutting, bending, binding, straighting and laying in position M.S. rods including cost of binding wire and cost of MS rods as per the dirction of Engineer-in-charge. |
| 13 | Supplying all labour, T&P and material for Providing 12mm thick cement plaster (1:6) over brick work including rackingant joints, watering, curing and conveyance of all materials to work site etc. complete as per the dirction of Engineer-in-charge. |
| 14 | Supplying all labour, T&P and material for Providing 12 CP with Bitumen Painting in cement plaster (1:4) over wall including watering, curing etc. all complete as per the dirction of Engineer-in-charge. |
| 15 | Supplying all labour, T&P and material for Providing Vetrified Tile in floor with CM(1;1) including watering, curing and conveyance of all materials to work site etc. complete as per the dirction of Engineer-in-charge. |
| 16 | Supplying all labour, T&P and material for Providing Vetrified Tile in Wall & Dado with CM (1;3) including watering, curing and conveyance of all materials to work site etc. complete as per the dirction of Engineer-in-charge. |
| 17 | Supplying all labour, T&P and material for Providing and fixing 5cm. thick RCC jalley in position as per the dirction of Engineer-in-charge. |
| 18 | Supplying all labour, T&P and material for Providing M.S. Grills as per specification as per the dirction of Engineer-in-charge. |
| 19 | Iron work wrought and put in window grating including drilling holes in chowkathas including all cost of materials and labours etc. all complete. |
| 20 | Supplying all labour, T&P and material for Providing Wall Putty with good quality putty on new plaster surface as per the dirction of Engineer-in-charge. |
| 21 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade. |
| 22 | Finishing wall with water proofing Weather coat over one caot primer two coats including cost of cemnt paint out side etc.complete as per direction of the Engineer-in-charge. |
| 23 | Supplying all labour, T&P and material for Painting two coats to MS Grills with any approved paint over one coat of primer as per the dirction of Engineer-in-charge. |
| 24 | Supplying , fitting,fixing up window (sliding type) made up aluminium section 151-154, 151-155, as windows frame section No.151-155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of all materials all taxes labour, T&P etc. complete as per direction of the Engineer-in-charge. |
| 25 | Supplying all labour, T&P and fitting and fixing of 32 mm thick flush door made out of 32mm thick BWR Block Board covered with 4mm thick veneer to both side wth melamine polish including cost of all materials all complete as per direction of Engineer in Charge. |
| 26 | Providing, fitting, fixing of Stainless Steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90mtr C/C and staineless square pipe bracing of size 32mmx32mmx 2mm in 3 rows in stair case asper approved design and specification,buffling polishing etc including all cost of labour, T&P, hire charges of of drilling machine, labour charges etc. complete as per direction of Engineer-in-charge. |
| 27 | Providing and fixing Ceramic tiles in floors, treads or steps and landing on 25 mm thick bed of cement mortar (1:1) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles as directed by the Engineer-in-charge. |
| 28 | Providing and laying of 60 mm thick factory made cement concrete interlocking paver block of M35 grade and approved make variety colour and size made by block making machine with strong vibratory compaction of approved design and shape laid in required colour and pattern over 50mm thick compacted bed of coarse sand filling the joints with lime sand etc all complete including cost conveyance, royalty taxes of all materials labour T&P etc complete as directed by the Engineer-in-charge. |
| 29 | PH Work : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes confirming to Is : 15778 having thermal stability for hot & cold water supply, including all CPVC plain & brass threades fitting including fixing the pipe with clamps at 1:00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of EIC.(a) 25 mm dia CPVC pipe |
| 30 | Providing & laying in trenches unplastisized PVC pipes confirming to IS:4985 - 2000 and specials of the following out side diametre for all classes including jointing with supply of approved solvent cement by non heat application method including testing as per specification complete.30.(a)110 mm dia D/S SWR Pipe |
| 31 | 30. (b) 75 mm dia D/S SWR Pipe |
| 32 | Providing and fixing of Brass Ball Valve (Hirizontal plunger type) confirming to IS : 1703-1977 as per specification complete.(a) 25 mm dia |
| 33 | Fixing of brass screw-down bib cocks (tapes) polished bright confirming to IS : 781 - 1995 of following nominal size as per specification complete.33.(a) 15 mm dia CP brass long body bib cock |
| 34 | 33. (b) 15 mm dia CP brass short body bib cock |
| 35 | Providing Rotational moulded polyethylene cylindrical vertical water storage tanks confirming to IS : 12701 - 1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra socket and jam nut, fixing ball valve etc. including hosting upto a height of 5 mtrs above ground level and placing the tank to the required position etc. all complete as per specification and direction of EIC. (a) 1000 litre capacity 3-layer cylindrical vertical water storage tank. |
| 36 | Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc all complete as per specification. (a) 250 mm thick wall |
| 37 | Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete.(a) Ground floor cutting |
| 38 | Supplying & fixing wash basin with hole for pillar taps confirming to IS 2556 : part 4-2004 with cast iron or MS bracket painted white including cutting holes in walls and making good the damages etc all complete as per specification.(a) Vitreous china flat back wash basin 550 x 400 mm |
| 39 | Fixing padestal for wash basin complete recessed at the back for the reception of pipes and fittings all complete as per the direction of EIC.(a) Vitreous china padestal for wash basin |
| 40 | Fixing Pillar Taps capstan head screw down high pressure lettered 'hot' and 'cold' with long screws, shank and back nurs of the following nominal bore as per specification.(a) Add contractor profit & OHC |
| 41 | Fixing wash down water closet (European type W.C. pan) with integral 'S' or 'P' trap confirming to IS : 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc. all complete as per the specification. (seat and cover to be measured and paid separately.(a)Porcelain EWC with P Trap |
| 42 | Providing and fixing PVC low level flushing cistern with manually controlled delivery (handle lever) confirming to IS : 7231, with all fitting and fixures complete.(a)10 litre capacity- white low level cistern |
| 43 | Fixing bowl pattern urinal confirming to IS : 2556 : Part 6-1996 including connecting the urina of 430 x 260 x 350 mm or 340 x 410 x 265 mm size respectively with waste pipe by means of white lead mixed with chopped hemp etc all complete as per the specification.(a) Vitreuos China Flat Back Urinal of 430 mm x 260 mm 350 mm size. |
| 44 | Supplying & fixing chromium plated brass shower rose with 15 mm or 20 mm inlet including polishing all complete as per specification.(a) 15 mm dia CP revolving shower |
| 45 | Supplying & fixing standard size chromium plated brass towel ring fixed to wooden plug with chromium plated brass screws complete as per specification.(a)Chromium plated brass towel ring |
| 46 | Sixing standard sized chromium plated towel rail complete with chromium plated brass bracket fixed to wooden plugs with chromium plated brass screws, complete as per specification.(a) Chromium plated brass towel rail |
| 47 | Supplyng & fixing (a) liquid soap container - glass container or plastic container with chromium plated brass lid and bracket fixed to wooden plugs with chromium plated brass screws or (b) chromium plated brass soap dish complete with chromium plated brass brackets fixed to wooden plug with chromium plated brass screws as per specification.(a) Liquid soap container |
| 48 | 47.(b)CP soap holder |
| 49 | Fixing 600 mm x 450 mm bevelled edge mirror of superior glass mounted on 6 mm thick A.C. sheet or plywood sheet and fixed to wooden plugs with cromium plated brass screws and washers complete as per specification.(a) 600 mm x 450 mm bevelled edge mirror |
| 50 | Supplying all materials, labour, T & P for lowering and testing of 1.00 HP vertical submerssible pump set with 25 mm dia PVC column pipe and covering the top of tube well with CI bore cap, connected with delivery pipe line including making all required lectrical connection with control panel and main swithch etc. all complete,as per the necessity and as per the direction of EIC. (a) 1.00 HP vertical submerssible pump set |
| 51 | 50.(b) 1.00 HP control panel |
| 52 | 50.( c )32 mm dia column pipe (HDPE) |
| 53 | 50. ( d)1.50 sqmm submerssible cable |
| 54 | 50.(e ) Plastic rope |
| 55 | 50.(f) 32 mm dia GI adoptor |
| 56 | 50.(e) Labour Charges for lowering & testing |
| 57 | Constructio of brick masonary septic tank as per the approved design, drawing & specification of size (L) 3.66 x (B) 1.66 x (H) 2.00 mtr including all cost, conveyance, royalty & taxes of materials & labour and as per the direction of EIC. |
| 58 | Construction of RCC ring soak pit as per approved design, drawing & specification of size 1.50 mtr dia x 50 mm thick x 1.00 mtr height with RCC cover slab including all cost, conveyance, royalty & taxes of materials & labour and as per the direction of EIC. |
| 59 | Construction of brick masonary manhole chamber as per approved design, drawing & specification of inner size 0.40 x 0.40 x (H) 1.00 mtr with RCC cover slab including all cost, conveyance, royalty & taxes of materials & labour and as per the direction of EIC. |
| 60 | Internal Electrification : Supply, Installation, Testing, and Commissioning of 100 Amp TPN Main switches of following capacity (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, interconnections, earthing, etc. as required as per direction of Engineer in Charge.Make- SEIMENS/HPL/ANCHOR/L&T/HAVELS/C & S/ RK |
| 61 | Supply and fixing of following rating four pole (three phase and neutral) 240 V residual current break (RCCB) having a sensitivity current up to 300 milli ampere in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. |
| 62 | Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR). (a ) 12 WAY, SPN, Double Door, MCB DB |
| 63 | Supply and fixing of 5 amp to 32 amp rating 240 V \\"B\\" series miniature circuit breaker suitable for lighting and other loads of the following poles in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required. (a) 32 amp rating SPN MCB \\"B\\" series |
| 64 | 63.(b) 63 amp 2 pole isolator |
| 65 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/ L&T/ Anchor/ Havels/ V Guard) |
| 66 | Recessed wiring to sub-main in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confiriming to IS 694/1990 in 20mm dia non-metalic heavy duty flexible conduit 1 x 1.5 sqm.mm FR PVC insulated single core multistrand copper conductor as earth wire. as required (Make of wire Finolex / L&T / Anchor / Havels / V.Guard) |
| 67 | Supply and drawing of following sizes FR PVC insulated single core multistrand copper conductor in existing surface / recessed STEEL/PVC conduit as required.(a) 1.5 sqmm. single core copper conductor for invertor |
| 68 | Recessed wiring to light point / fan point / exhust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metalic PVC flexible conduit with 5 amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bake lite cover of suitable size MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earthing wire including all accessories and as per direction of EIC (Make of wire Finolex / L&T / Anchor / Havels / V.Guard). (a) Short point |
| 69 | 68.(b ) Medium point |
| 70 | 68. ( c )Long point |
| 71 | Supplying and fixing of Modular base & cover of following sizes (nominal size) on surface / recess including cutting the wall and making good the same in case of recessed conduit as required. (a) Modular base & cover for 12 module |
| 72 | 71.(b) Modular base & cover for 8 module |
| 73 | 71.( c )Modular base & cover for 4 module |
| 74 | 71.(d ) Modular base & cover for 1 module |
| 75 | Supply and fixing of following piana type modular switch/ socket on the existing switch bos/ cover including connection etc as required.( a) 6 pin 15/ 16 amp modular socket outlet |
| 76 | 75.( b ) 15/ 16 amp modular switch |
| 77 | 75.( c ) 3 pin 5/ 6 amp modular socket outlet |
| 78 | 75.( d ) 5/ 6 amp modular switch |
| 79 | Supplying and fixing of 3 pin, 5 amp ceiling rose ISI marked on the existing junction box / wooden block including connection etc. as required |
| 80 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required |
| 81 | Installation, Testing and Commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required. |
| 82 | Installation, testing and commissioning of exhaust fan up to 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required. |
| 83 | Installation, Testing and Commissioning of pre-wired compact fluorescent fitting of all sizes complete with all accessories and tube etc. directly on ceiling wall, including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. (a) 18 watt batten fluorescent tube |
| 84 | ( b ) 50 watt LED street light |
| 85 | Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required |
| 86 | Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required |
| 87 | Cost for power supply connection to ofice bulding Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender